WoodGroup ESP, Inc.

- Oman
Vortex Setup Sheet

Field :_________________________ Well :___________________________

# Parameter Default Set # Parameter Default Set # Parameter Default Set


1 Current A 41 Overload Delay 2 1.5 1.5 81 Undervolt 7 Setpt 0.67 0.67
2 Current B 42 Overload Delay 3 2.0 2.0 82 Volt Demo Mode No No
3 Current C 43 Overload Delay 4 3.0 3.0 83 Prog Restart Time 0 0
4 Voltage AB 44 Overload Delay 5 4.0 4.0 84 Reserved 0 0
5 Voltage BC 45 Overload Delay 6 6.0 6.0 85 Wait for Restart No No
6 Voltage CA 46 Overload Delay 7 8.0 8.0 86 Power Fail Volt 140 140
7 Power Factor 47 Norm U/L Delay 8.0 8.0 87 P-Word Clr L/O No,No No,No
8 Minutes til Start 48 Norm Undervolt 4.0 4.0 88 Central Control 0 0
9 Restart Delay 30 30 49 Undervolt Delay 2 1.5 1.5 89 Volts Compense 1.03 1.03
10 CT Ratio 100 100 50 Undervolt Delay 3 2.0 2.0 90 Kratos Light Mode No No
11 Overload Setpnt 100 100 51 Undervolt Delay 4 3.0 3.0 91 Master Password 0 0
12 Underload Setpnt 50 50 52 Undervolt Delay 5 4.0 4.0 92 RTU Address 0 1
13 Overvolt Setpoint 530 530 53 Undervolt Delay 6 6.0 6.0 93 Transmit Delay 0 0
14 Undervolt Setpoint 430 430 54 Undervolt Delay 7 8.0 8.0 94 Last Shutdown Ann 1 Ann 1
15 Rotation Setpoint Abc Abc 55 Norm Overvlt Dly 4.0 4.0 95 2nd-last Shutdwn Ann 2 Ann 2
16 Analog In #1 0 0 56 Norm V Unbal Dly 1.0 1.0 96 3rd-last Shutdwn Ann 3 Ann 3
17 Password 0 0 57 Norm I Unbal Dly 2.0 2.0 97 4th-last Shutdwn Ann 4 Ann 4
18 Resetlbe Run Hrs 0 0 58 Norm Pressure Dly 4.0 4.0 98 5th-last Shutdwn Ann 5 Ann 5
19 Total Run Hours 0 0 59 Norm Spare Dly 0.5 0.5 99 Lower Overload 0 0
20 Total Starts 0 0 60 Analog #1 Delay 5 5 A0 1 Restart on ovld No No
21 Analog 1 F.Scale 5000 3500 61 Start Ovload Dly 0.0 0.0 A1 Progran Rev.No. 4.3 4.3
22 Analog #1 Lo Trip 0 0 62 Start Undrload Dly 1 min 1 min A2 Erase Setpoints No No
23 Volt Unbalance 99.1 99.1 63 Start Undrvolt Dly 4.0 4.0 A3 Erase Code 0 0
24 Volts Unbal Setpt 4.0% 4.0% 64 Start Overvolt Dly 4.0 4.0 A4 Rotation EN/LO?
25 Amps Unbalances 0 0 65 Start V Unbal Dly 4.0 4.0 A5 Rotation Run Dly 8.0 8.0
26 Amps Unbal Setpt 25.0% 25.0% 66 Start I Unbal Dly 0.0 0.0 A6 Strt Rotation Dly 8.0 8.0
27 Runtime frm Start 0 0 67 Start Pressure Dly 0.0 0.0 A7 Analog #2 Read 0 0
28 Max Allow Starts 3 3 68 Start Spare Delay 0.0 0.0 A8 Analog #2 Scale 5000 5000
29 Starts Counter 0 0 69 Start Analog #1 Dly 0 sec 0 sec A9 Analog #1 Hi Trip 5000 5000
30 Counter 60 60 70 Ovload 2 Setpoint 1.17 1.17 B0 Comm Protocal 0 0
31 Overld Enable/LO Ys,Ys Ys,Ys 71 Ovload 3 Setpoint 1.33 1.33 B1 Underload Bypass 0 0
32 Underld Enable/LO Ys,No Ys,No 72 Ovload 4 Setpoint 1.5 1.5 B2 Kilowatts 0.0 0.0
33 Undervolt En/LO Ys,No Ys,No 73 Ovload 5 Setpoint 1.67 1.67 B3 Gigawatt-Hours 0 0
34 Overvolt En/LO Ys,No Ys,No 74 Ovload 6 Setpoint 1.84 1.84 B4 Megawatt-Hours 0 0
35 VoltUnbal En/LO Ys,No Ys,No 75 Ovload 7 Setpoint 2.00 2.00 B5 Kilowatt-Hours 0 0
36 Amp Unbal En/LO Ys,Ys Ys,Ys 76 Undervolt 2 Setpt 0.91 0.91 B6 U/L Delay Ext 0 0
37 Pressure En/LO Ys,No Ys,No 77 Undervolt 3 Setpt 0.87 0.87 B7 Baud Rate 1200 1200
38 Spare En/LO No,No Ys,No 78 Undervolt 4 Setpt 0.83 0.83 B8 CPU Utilization % Varies Varies
39 Analog #1 En/LO No,No Ys,No 79 Undervolt 5 Setpt 0.80 0.80 B9 Timers In Minutes No No
40 Norm O/L Delay 8.00 8.00 80 Undervolt 6 Setpt 0.77 0.77 C0
A-Phase B-Phase C-Phase PHD Start
D.H. Volts PHD Stable
Start Amps
Stable Amps
Cable Length V-Drop K/Ft Motor VT Drop

Technician:__________________________________ Date:_______________
WoodGroup ESP, Inc. - Oman
Actual Tap Cable Size Xfmr Prmry VT

Technician:__________________________________ Date:_______________