B&C Lintel Details-Block-B&c

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

MATERIALS

DESCRIPTION CONCRETE STEEL CLEAR COVER

8 9 10 11 BEAMS
SLABS
M40
M40
Fe 500
Fe 500
25mm
20mm

NOTES
1. ALL DIMENSIONS ARE IN `mm'. UNLESS OTHERWISE SPECIFIED.

4750 5400 5400 2. DO NOT SCALE THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE TO BE
FOLLOWED.

600MAX 750MAX 3. MINIMUM LAP LENGTH OF REINFORCEMENT SHALL BE 50 TIMES OF DIA. OF


BAR FOR FOOTINGS , COLUMNS, SLABS & BEAMS.

CHAJJA PROJ. CHAJJA PROJ. 4. LAPS SHALL BE STAGGERED & NOT MORE THAN 50% OF BARS SHALL BE

1
-
LAPPED AT ANY LOCATION FOR BEAM & 33% FOR COLUMNS.
5. THIS STRUCTURE IS DESIGNED FOR GROUND + 7 FLOOR ONLY.
6. READ THIS DRAWING ALONG WITH RELEVANT ARCHITECTURAL DRAWING.
7. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF CONSULTANT
BEFORE EXECUTION.
8. LIGHT WEIGHT AEROCON BLOCKS & CC BLOCKS HAS BEING USED IN DESIGN.
(CC BLOCKS ARE CONSIDERED IN TOILET PORTION ONLY)
9. M/S MURTY & MANYAM IS RESPONSIBLE FOR RCC ELEMENTS LIKE FOOTINGS,
LB1(200x300) LB1(200x300) LB1(200x300) LB1(200x300) PLINTH BEAMS, CONVENTIONAL BEAMS AND CONVENTIONAL SLABS ONLY.
PT BEAMS AND PT SLABS ARE DESIGNED BY
M/S UTRACON STRUCTURAL SYSTEMS PVT. LIMITED.

REFERENCE DRAWINGS

LB1(200x300) LB1(200x300)
LB1(200x300) LB1(200x300)
DRAWINGS OF PROPOSED PEARL RESEARCH PARK- PHASE 2
- VELLORE INSTITUTE OF TECHNOLOGY ,
SITUATED IN THE SITE OF LAND SURVEY NO.354/1,354/2 &355
BRAMMAPURAM VILLAGE, KATPADI TALUK, VELLORE DISTRICT

1
-
600MAX 750MAX
CHAJJA PROJ. CHAJJA PROJ.

GOOD FOR CONSTRUCTION


A
D
TYPICAL LAYOUT OF LINTEL BEAMS FOR BLOCK-B&C
TYPICAL SCHEDULE OF LINTEL BEAMS FOR BLOCK-B&C
FFL FFL 200 200 200
150 mm THICK SLAB LB-1 200x300 3-12 (st) 3-12 (st) 3-12 (st)
RB RB C B

300

300

300
8 @150c/c 8 @150c/c 8 @150c/c

FIXED GLASS FIXED GLASS 3-12 (st) 3-12 (st) 3-12 (st) CLIENT:

LINTEL LVL LINTEL LVL


BEAM BEAM B VELLORE INSTITUTE OF TECHNOLOGY,
University in Vellore, Tamilnadu
LB1
600MAX
CHAJJA PROJ.
600MAX
CHAJJA PROJ. 8 @150 c/c(MAIN)
Ld As per ARCH. Plan
D

SUBJECT: PEARL RESEARCH BLOCK PHASE-2


100

(BLOCK-B&C)

75
DRAWING: TYPICAL LAYOUT OF LINTEL BEAM DETAILS FOR B&C
BLOCK CONNECTING CORRIDER.
FFL
8 @200 c/c(DIST) Drawing No MM/PRP/PH2/B&C/
S-02
DRAWN HEMANTH

TYPICAL CHAJJA DETAILS(750MM MAX) Scale

Proof CHKD
PROF.
1:50

MURALI KRISHNA
DESIGNED

Chkd
KRV

GSR

Date 10/10/2023 Qlty Chkd Shivaprasad


SECTION - 1-1(TYPICAL) NOTE: 1.MAXIMUM HEIGHT OF SUPER STRUCTURE
REV. NO DATE REVISION APPROVED
ON LINTELS SHOULD NOT EXCEED 1.5 M
2.LOCATION OF LINTELS AND SUNSHADES
REFER ARCHITECTURAL PLANS.