Civil Aviation Authority of Nepal

Monthly check-up Sheet


NEC DVOR

Site/Location: Date:
Check by: Lic. No.:
Room-> Temperature: City Supply (V):
Humidity: Gen Supply (V):

Standard/ Observation/Measurement References on


SN Parameter Description
Tolerances Tx 1 Tx2 System Manual

System LEDs on the CSP


1 Refer 4.3.2
Status Lamp Test
Station
Carrier
freq±0.002%
RF (Station
2 Refer 4.3.3
Frequency freq+1KHz)±1%
Sideband
(Station freq-
1KHz)±1%
30 Hz AM 30±2 %

3 Modulation 1000 Hz AM 30±2 % Refer 4.3.15

FMI 16±1
Carrier
Clean 30 Hz sine
4 Modulation 30Hz ± 1% Refer 4.3.4
wave
Waveform
Sideband
720 Hz rectified
5 Blending 720Hz Refer 4.3.5
sinewave
Waveform
Remarks:
Civil Aviation Authority of Nepal
Quarterly check-up Sheet
NEC DVOR

Site/Location: Date:
Check by: Lic. No.:
Room-> Temperature: City Supply (V):
Humidity: Gen Supply (V):

Standard/ Observation/Measurement References on


SN Parameter Description
Tolerances Tx 1 Tx2 System Manual
As per the
Site Site
1 ICAO --
environment environment
standard
cooling fan
2 FAN --
(blowers)
Carrier FC
Refer 4.3.6
Output Power value±10%
3 Power
Sideband FC
Refer 4.3.7
Output Power value±10%
IDENT speed 7 WPM
IDENT
4 IDENT 2 TPM Refer 4.3.8
Repetition
IDENT Freq 1020±50Hz
Carrier
Antenna <1.5
VSWR
5 VSWR Refer 4.3.9
Sideband
Antenna <1.5
VSWR (Avg.)
Check
6 Battery Backup 30 min Refer 4.3.10
Battery
Check
Automatic
7 Changeover within 20 sec Refer 4.3.11
Transmitter
Changeover
Switch
8 Transfer Main/Standby Immediately Refer 4.3.12
Transmitter
Remarks:
Civil Aviation Authority of Nepal
Annual and Preflight check-up Sheet
NEC DVOR

Site/Location: Date:

Check by: Lic. No.:

Room-> Temperature: City Supply (V):

Humidity: Gen Supply (V):

References on
Standard/ Observation/
SN Parameter Description System
Tolerances Action done
Manual
Each Antenna
Antenna element and Radome
1 Refer 4.3.13
Radome
Each Antenna
Element

Monitor Antenna
2 Monitor Antenna Refer 4.3.14
and its feeder cables

30 Hz AM 30 ± 2 %
Monitor Parameters 9960 AM 30 ± 2%
(Verify all monitor 9960 FM 16 ± 1
3 Refer 4.3.15
parameters with the 1020Hz Mod. ≤ 20 %
PIR) Azimuth ± 10
RF Level Fc Value ± 1 dB
Remarks:
Civil Aviation Authority of Nepal
Monthly check-up Sheet
NEC DME

Site/Location: Date:
Check by: Lic No.:
Room-> Temperature: City Supply (V):
Humidity: Generator Supply (V):

Standard/ Observation/Measurement References on


SN Parameter Description
Tolerances Tx 1 Tx2 System Manual

LEDs on CSP
System
1 4.4.1
Status Lamp Test

2 Reply Delay System Time Delay 50±0.5µs 4.4.2

Normal operation Strongly recommended to use Vacuum not


Equipment of AC, FAN
3 Blower. Cleaning should be done on system 4.4.3
Cleaning
Clean Cabinet shutdown condition only.
Remarks:
Civil Aviation Authority of Nepal
Quarterly check-up Sheet
NEC DME

Site/Location: Date:
Check by: Lic No.:
Room-> Temperature: City Supply (V):
Humidity: Generator Supply (V):

Observation/Measurement References
Standard/
SN Parameter Description on System
Tolerances Tx 1 Tx2 Manual
FC value ± 1
1 RF Power Power on Antenna 4.4.4
dB
Pulse Width 3.5 ± 0.5 µs
Reply Pulse Rise Time ≤ 3 µs
2 4.4.5
Characteristics Decay Time ≤ 3.5 µs
Pulse Spacing 12 ± 0.25 µs
Output Pulse
3 Min. PRF 700 PPS 4.4.6
Count
Receiver
4 < -81 dBm 4.4.7
Sensitivity
Peak Power Output
verify each
Output Pulse Count parameter
5 Monitor Alarm Reply Efficiency generates 4.4.8
Reply Delay alarm on alarm
limits
Pulse Pair Spacing
+5±0.25 V
DC Voltage (DC/DC-
+15±0.75 V
A)
-15±0.75 V
+5±0.25 V
+15±0.75 V
6 Power Supply DC Voltage 4.4.9
-15±0.75 V
(DC/DC-1; DC/DC-2)
+8±0.4 V
+50±2.5 V
DC Voltage (AC-DC) +28±1.4 V
Battery Backup 30 Minute
Remarks:
Civil Aviation Authority of Nepal
Annual and Preflight check-up Sheet
NEC DME

Site/Location: Date:
Check by: Lic No.:
Room-> Temperature: City Supply (V):
Humidity: Generator Supply (V):

Standard/ Observation/ References on


SN Parameter Description
Tolerances Action done System Manual
1 Transmitter Frequency Station Frequency ±0.001% 4.4.10
2 Monitor Alarm Delay 4±0.4 sec 4.4.11
3 Bite Certification Monitor status indicated correctly 4.4.12
Antenna
4 Ground Resistance 4.4.13
Equipment
RF Cables
Antenna distributions, connectors
and supporting pedestals
OB light
5 Damage 4.4.14
cracks and breakage of Coaxial
cable, antenna unit
Tightness of all mechanical parts
Dust, corrosion and foreign dirt
Remarks: