DVOR Blank Checkup Sheet
DVOR Blank Checkup Sheet
Site/Location: Date:
Check by: Lic. No.:
Room-> Temperature: City Supply (V):
Humidity: Gen Supply (V):
FMI 16±1
Carrier
Clean 30 Hz sine
4 Modulation 30Hz ± 1% Refer 4.3.4
wave
Waveform
Sideband
720 Hz rectified
5 Blending 720Hz Refer 4.3.5
sinewave
Waveform
Remarks:
Civil Aviation Authority of Nepal
Quarterly check-up Sheet
NEC DVOR
Site/Location: Date:
Check by: Lic. No.:
Room-> Temperature: City Supply (V):
Humidity: Gen Supply (V):
Site/Location: Date:
References on
Standard/ Observation/
SN Parameter Description System
Tolerances Action done
Manual
Each Antenna
Antenna element and Radome
1 Refer 4.3.13
Radome
Each Antenna
Element
Monitor Antenna
2 Monitor Antenna Refer 4.3.14
and its feeder cables
30 Hz AM 30 ± 2 %
Monitor Parameters 9960 AM 30 ± 2%
(Verify all monitor 9960 FM 16 ± 1
3 Refer 4.3.15
parameters with the 1020Hz Mod. ≤ 20 %
PIR) Azimuth ± 10
RF Level Fc Value ± 1 dB
Remarks:
Civil Aviation Authority of Nepal
Monthly check-up Sheet
NEC DME
Site/Location: Date:
Check by: Lic No.:
Room-> Temperature: City Supply (V):
Humidity: Generator Supply (V):
LEDs on CSP
System
1 4.4.1
Status Lamp Test
Site/Location: Date:
Check by: Lic No.:
Room-> Temperature: City Supply (V):
Humidity: Generator Supply (V):
Observation/Measurement References
Standard/
SN Parameter Description on System
Tolerances Tx 1 Tx2 Manual
FC value ± 1
1 RF Power Power on Antenna 4.4.4
dB
Pulse Width 3.5 ± 0.5 µs
Reply Pulse Rise Time ≤ 3 µs
2 4.4.5
Characteristics Decay Time ≤ 3.5 µs
Pulse Spacing 12 ± 0.25 µs
Output Pulse
3 Min. PRF 700 PPS 4.4.6
Count
Receiver
4 < -81 dBm 4.4.7
Sensitivity
Peak Power Output
verify each
Output Pulse Count parameter
5 Monitor Alarm Reply Efficiency generates 4.4.8
Reply Delay alarm on alarm
limits
Pulse Pair Spacing
+5±0.25 V
DC Voltage (DC/DC-
+15±0.75 V
A)
-15±0.75 V
+5±0.25 V
+15±0.75 V
6 Power Supply DC Voltage 4.4.9
-15±0.75 V
(DC/DC-1; DC/DC-2)
+8±0.4 V
+50±2.5 V
DC Voltage (AC-DC) +28±1.4 V
Battery Backup 30 Minute
Remarks:
Civil Aviation Authority of Nepal
Annual and Preflight check-up Sheet
NEC DME
Site/Location: Date:
Check by: Lic No.:
Room-> Temperature: City Supply (V):
Humidity: Generator Supply (V):