SCOPE OF APPLICATION

DZ47-63 miniature circuit breaker is mainly used in the AC 50 / 60Hz, rated operating voltage of 230V / 400V and below, rated
current of 63A circuit, the circuit breaker is mainly used in electrical wiring of modern buildings and overload, short circuit
protection of equipment, also applies to infrequent operation and isolation of the line. Structural features of DZ47-63 MCB is
composed of the plastic casing, operating mechanism, contact arc system, trip mechanism and other components. The casing
uses a special plastic with high flame retardant and high strength, it has high impact resistance and light-weight. The parts of
the operating mechanism of MCB are made of high-strength plastic, which ensures the sensitivity and reliability while obtaining
the lowest moment of inertia so that the time from the short circuit fault to the trip mechanism operation is short. The tripping
mechanism is composed of a bimetal over-load reverse-time trip mechanism and a short-circuit instantaneous electromagnetic
mechanism. Contact arc system uses a special guide arc angle and aisle off room, and has significant current limiting
characteristics.
The product complies with IEC60898 and GB10963.1 Standard requirements. DZ47-63miniature circuit breakers produced by
DIHOOL have been certified by the national CCC and CE
NORMAL OPERATING CONDITIONS AND INSTALLATION CONDITIONS

The upper limit of ambient temperature does not exceed +40 °C, the lower limit does not less than -5°C, and the average
temperature of 24h does not exceed +35 °C.
Altitude of the installation site should not exceed 2000m.
Atmospheric relative humidity at ambient air temperature +40°C is not more than 50%, it allowed to have a higher relative
humidity at lower temperature
temperatures; for example at + 20°C up to 90%. Special precautions should be taken for condensation that
may occasionally occur on the product due to temperature changes.
Pollution Degree: Grade 2.
Installation conditions: Installed in a place without significant impact, vibration, non-hazardous (explosive) medium.
Installation: TH35-7.5 installation rail.
Installation category: Class II, III.

Electrical Features

Rated Current Rated Current

Poles 1P 2P 3P 4P

Rated Voltage Ue 90V-125V 200-400V

Insulation Volage Ui 500V

Rated Frequency 50/60Hz

Rated Breaking Capacity 4000A

Rated Impulse Withstand Voltage Uimp 6kV

Dielectric Test Voltage At And Ind. Freq.For 1min 2kV

Thermo-Magnetic Release Characteristic B (3In ~ 6In); C (5In ~ 10In); D (10In ~ 20In).

Electrical Life 4000

Mechanical Life 20000

Installation

Contact Position Indicator YES

Protection Class IP20

Reference Temperature For Setting Of Thermal lement 30°C

Ambient Temperature(With
Temperature Daily Average (35°C) -5°C~40°C

Storage Temperature -25°C~+70°C

Terminal Connection Type Phillips Screws

Suitable For Cable Cross-Section 6-63A 1.5-25MM²;80-125A 4-35MM²

Tightening Torque 2.5-3.0N.m

Mounting 35MM DIN Rail or M4 Side Mounted

Combination With Accessories


Auxillary Contact DZ47-OF

Alarm Contact DZ47-SD

Shunt Release DZ47-MX(DC24V / AC230V)

UnderVoltage And UnderVoltage Release DZ47-MV+MN(AC230V / AC380V)

LossVoltage Release DZ47-MNs

Shunt Release + Auxiliary Contact DZ47-MX+OF(DC24V / AC230V)

TECHNICAL PARAMETERS

Rated short-circuit
Trip Type Rated Current COSΦ
breaking capacity A

C 1≤In≤40 6000 0.65~0.70

C 40<In≤63 4000 0.75~0.80

D 1≤In≤63 4000 0.75~0.80

7.3 Over-current protection characteristics under the ambient temperature of 30 D~35

No. Trip type Rated Current In Test current A Appointed time Expected result Initial state

1 C、 D All values 1.13In t≤1h Non tripping Cold

Immidiately after
2 C、 D All values 1.45In t<1h Tripping
the last test

≤32 s<t<60s
3 C、 D 2.55In Tripping Cold
>32 1s<t<120s

C 5In
4 All values t≤0.1s Non tripping Cold
D 10In

C 10In
5 All values t≤0.1s Tripping Cold
D 20In

Circuit breaker temperature compensation coefficient

Rated The temperature compensation coefficient corresponding to different temperature


current
In(A) -10℃ 0℃ 10℃ 20℃ 30℃ 40℃ 50℃ 55℃ 60℃

1~6 1.20 1.14 1.09 1.05 1.00 0.96 0.80 0.75 0.70

10~32 1.18 1.12 1.08 1.04 1.00 0.96 0.92 0.88 0.84
40~63 1.16 1.12 1.07 1.03 1.00 0.97 0.87 0.83 0.80

The correction factor of the current used by the circuit breaker at different altitudes

Trip type Rated curren ≤2000m 2000~3000m ≥3000m

C、D 1~125A 1 0.9 0.8

Wiring: 25mm² and below for wire connection, wiring method is screws to tighten the wiring, the torque is 2.0N · m.

Rated current In(A) Copper conductor nominal cross-sectional area (mm²)

1~6 1

10 1.5

16~20 2.5

25 4

25 4

40~50 10

63 16

TRIPPING CHARACTERISTIC CURVE

Rated Voltage
Product Model Drop away voltage Application
Un

To make the circuit


breaker tripping and achieve
Overvoltage value of overvoltage
MV 230V over-voltage protection of the line
Release Uwo=270V±5%
when the power supply
voltage rises to 270V±5%

Undervoltage MN 230V value of undervoltage To make the circuit breaker


Release Uoe=170V±5% tripping and achieve
under-voltage protection of the line
when the power supply voltage
falls between (0.35~0.75) Ue

value of overvoltage To make the circuit breaker


Uw0=270V±5% tripping and protect the line
overvoltage-undervoltage
MV+MN 230V value of undervoltage when the 230V rated supply voltage rises
Release
Uoe=170V±5% to 270±5% or falls at 170V±5%
U08=170V±5% to 270±5% or falls at 170V±5%

When the 230V rated voltage at 75% to 10


value of undervoltage the no-voltage release will pull in
Loss of pressure U0e=170V±5% to make circuit breaker switch on;
Mns 230V
release loss of pressure value When the rated voltage at 40%.
Uoe=0 Release the no-voltage will release to
make circuit breaker trip off.

value of overvoltage To make the circuit breaker


Three-phase overvoltage- Uwo=460V±15 tripping and protect the line
MV+MN 380V
undervoltage +default phase value of undervoltage when the 380V rated supply voltage rises
Uo8=300V±15 to 460±15 V or falls at 300±15V

value of overvoltage To make the circuit breaker


Three-phase four-wire Uo=270V±5% tripping and protect the line
GQ(MV+MN) 230V
overvoltage-undervoltage value of undervoltage when the 230V rated supply voltage rises
U0e=170V±5% to 270±5%or falls at 170±5%V

To make the circuit breaker


AC230V
tripping and protect the line
Shunt release MX
when the control voltage exceeds
DC24V
the rated voltage of 70% to 110%

Long-distance breaks circuit.


AC230V and to control the auxiliary
Shunt release circuit by auxiliary contacts
MX+OF
+Auxiliary contact Long-distance breaks circuit.
DC24V and to control the auxiliary
circuit b the micro-switch.

To provide alarm signal when


Alarm contact SD 115/230/400V 1.3A the circuit breaker breaking due
to protective circuits'fault

To provide auxiliary
Auxiliary contact OF 115/230/400V 1.3A signal and control
auxiliary circuit

MODEL MEANING AND MAIN TECHNICAL PARAMETERS

Rated insulation Rated control Release power


Circuit Breaker Accessory Pull-in voltage
voltage Ui supply voltageUs wastage(W or VA)

AC/DC:220~380V:110-220V 240
MX+OF Shunt release+
415V (0.7-1.1)Us
Auxiliary contact
AC/DC:24-48V 120
AC/DC:220~380V:110-220V 240
active 415V (0.7-1.1)Us
MX+OF AC/DC:24-48V 120
Shunt release+
Auxiliary contact AC/DC:220~380V:110-220V 240
passive 415V (0.7-1.1)Us
AC/DC:24-48V 120

AC/DC:220~380V:110-220V 240
MX Shunt release 415V (0.7-1.1)Us
AC/DC:24-48V 120

PRODUCT DIMENSIONS

Links
Circuit Breaker About TAIXI
non woven bag making machine
Distribution Electrical Download

Control Electrical FAQ Follow us

Energy Electrical Sitemap

Plug&Socket

Others
Copyright © 2002-2018 TAIXI Electric Co.,LTD All Rights Reserved Privacy policy, cookies & data protection

You might also like