Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PRODUCT

METSENS500
Compact Weather Sensor for Temperature, RH, Barometric
Pressure, and Wind with Compass

Measures 5
Common
Meteorological
Parameters
IEC 61724-1 Compliant

Overview
The MetSENS500 compact weather sensor measures wind making installation easier. WMO average wind speed and
speed and direction via an ultrasonic sensor, as well as air direction and gust, temperature, relative humidity, barometric
temperature, relative humidity, and barometric pressure, in a pressure, absolute humidity, air density, and wet bulb
single, combined instrument mounted inside three double- temperature data are provided. The MetSENS500 is compatible
louvered, naturally aspirated radiation shields with no moving and easily integrated with the MeteoPV Solar Resource
parts. An integrated electronic compass allows the Platform and any Campbell Scientific data logger using SDI-12,
MetSENS500 to provide accurate, relative wind direction RS-485, ModbusRS-485, or NMEA RS-232.
measurements without being oriented in a particular way,

Benefits and Features


Quality measurements Compact, integrated design
Fast and simple to install Lightweight and robust

Specifications
Measurements Made Air temperature, barometric Where applicable, all individual
pressure, relative humidity, wind parameters meet or exceed
direction, and wind speed. specifications of IEC 61724-1
(2017, 2021).
Sampling Rate 1 Hz
Operating Temperature -40° to +70°C
Digital Communication Serial RS-232, RS-485, SDI-12,
Range
Modes NMEA, Modbus, ASCII
Operating Voltage 5 to 30 Vdc
IP Rating 66
Typical Current Drain @ 12 25 mA (continuous high mode)
Compliance CE, RoHS
Vdc 0.7 mA (eco-power mode; 1 hour
polled)
Weight 0.7 kg (1.5 lb)

For comprehensive details, visit: www.campbellsci.com/metsens500


Air Temperature Measurement Accuracy ±5% (up to 60 m s-1)
Measurement Range -40° to +70°C ±3% (up to 40 m s-1)
Resolution 0.1°C Resolution 0.01 m s-1
Accuracy ±0.3°C (@ 20°C) Starting Threshold 0.01 m s-1

Relative Humidity Measurement Wind Direction Measurement


Measurement Range 0 to 100% Measurement Range 0° to 359°
Resolution 0.1 Accuracy ±3° (up to 60 m s-1)
Accuracy ±2% @ 20°C (10 to 90% RH) Resolution 1°
Barometric Pressure Measurement Compass
Measurement Range 300 to 1100 hPa Measurement Range 0 to 359°
Resolution 0.1 hPa Resolution 1°
Accuracy ±0.5 hPa (@ 25°C) Units of Measure Degrees
Wind Speed Measurement Accuracy ±3°
Measurement Range 0.01 to 60 m s-1

For comprehensive details, visit: www.campbellsci.com/metsens500

© 2023 Campbell Scientific, Inc. | 07/26/2023