Esco Medical Products
CelCulture®
CO2 Incubator
CelCulture® is equipped with a 90ºC Moist Heat Decontamination
System evaluated by HPA-UK. This incubator utilizes its ULPA filter
to keep the chamber at ISO Class 5 cleanliness. It offers rapid parameter
recovery and has ISOCIDETM antimicrobial coating. It can be fitted with
an optional Inner Door Kit (which reduces contamination risk) and other
accessories for specialized applications. In addition, it can be set up on
a floor stand with casters, a roller base, or a floor stand with adjustable feet.
Stereomicroscope
MIRI® GA Gas & Temperature Validation Unit
The MIRI® GA is a table-top device designed to make
external incubator validation easier and safer.
•Capable of monitoring the temperature
(PT1000 connector) as well as gas concentration,
flow, and pressure.
•Can validate up to 6 chambers simultaneously 24 hours a day.
•Has an adjustable flow rate which gives it the ability to properly
sample small-volume incubation chambers.
•Comes with a full data logger software which is helpful in monitoring each parameter.
The optional integration of SAFE Sens technology into any Esco MIRI®
incubator allows for the highly reliable pH monitoring of media.
Each single-use sensor can be utilized for up to 7 days so you can get real-time,
continuous pH monitoring for your embryo culture at your fingertips.
Andrology Equipments
Sperm Preparation Media
IVF Equipments
ICSI & Cryolab Equipment
Quality Control
Consumables
Turnkey Projects
-Androstation is designed to
provide clean air devoid
of SPMs in the Andrology Lab
environment.
-The HEPA filters assembled
in the cabinets are fully
validated to ensure optimal
performance.
-Microprocessor control with bright green LCD
display & Feather touch keypad.
Low Noise & Low Vibration.
SPERM COUNTING
CHAMBER
species (ROS).
-Eliminates suboptimal sperm.
-The Profert Sperm Screen Kit is a three in one kit for sperm
preparation through the density gradient centrifugation method.
along with additional HEPES media for washing off the gradient.
-Available in a kit of ready to use vials
-g-Force indication
-Intelligent Control System
Jacket Warmer
JW 260
-Filters 1set
Oocyte Aspirator
OA 500
Foot Pedal
-Multiple profiles
available with distinct temperature control & gas supply for each chamber.
-With the Japanese precision the Digital PID temperature controls to the accuracy
IVF CUBE
Drawer Incubator
-Cube is a unique incubator that allows you to
slide out of the Cube & you can port them directly
-Easy grip knob on the drawer, latch & hinges of the lid.
-Fluid trap prevents accidental aspiration of fluids into the vacuum unit.
CCM-iBIS
Embryo Viewer Incubator
-CE certified
SZX10
Olympus Stereozoom
Trinocular Microscope
bult in aperture stop in the zoom body objectve mounting by screw mount type,
incrorporated.
SZX61
Trinocular Microscope
Optical Performance.
INVOTEC WORKSTATION
180 Series
30 LTR INCUBATOR
-Full HD resolution
-Easy installation
On Screen Control
Colour Weakness Mode
you want to view the video on monitor using the camera. However,
you will need the desktop computer if you would like to record the video.
Usually, the IVF clinics will not record the video so this external frame
grabber card is enough to work under the microscope with the help
operation at high magnification all under the strictly controlled fan circulated environment.
-Various hinged doors and Iris arm ports allow comfortable access
to all equipment and controls in the cell with sterile filtered water.
Labcell-s
microscope brands.
-They provide safe stable work areas & are level with the microscope stage.
-Racks & supports on the work areas accommodate sterile pipettes & utensils.
-A water tray located at the end of the work area provides humidification
-196 deg.C.
-It should have gauge to measure the built-in pressure.
IX 73 ON4 Olympus Dp22 Camera , Monitor with Spindle Check & IMSI
CRYO CANES
CRYO CANES
65 mm dia
Can hold visiotubes/ Cane/ Cassettes
Goblets comes standard white color
Ref: 57100 - Pack of 10's
CRYO PEN
Manufactured Nunc-NordicCell, Denmark
Set of 4 colored pens
Cryosafe
Used for marking on to plastics and paper products
preserved under ultra-low temperatures
CRYO CANES
For holding Cryovials under LN2
in a Dewer Canisters will hold the
canes with Cryo vials Pack of 50s
VISIOTUBES
Manufactured by NordicCell, Denmark ( assorted colors)
Round Visiotubes of 13 mm dia
Available in assorted colours
Visiotubes are used for holding cassettes/ vials/ straws in LN2
Visiotubes are placed in Goblets which are inturn, placed in canisters.
Standard Pack Size is 60pcs per bag
MULTI PURPOSE CASSETTES
Length of 280 mm
Secure, Cryo proof, transparent cassettes
storage of various types of straws.
Avialable in assorted colours
Standard pack size is 50 pcs
Cassettes can be placed either in visiotubes/ goblets/
canisters while storing under LN2
PASS BOX
Specifications:
·Type of gas CO2
·Model Ketan
·Max. inlet pressure: 200 bar
·Max. flow rate 35 ltrs/min
Outlet pressure up to 5 bar
N2 REGULATOR
Features:
-Sturdy flow of gas at the outlet irrespective of cylinder gas volume
-Pressure reduction from manifold or cylinder is achieved in 2 stages
-Dual gauge displaying cylinder pressure and output working pressure
-Suitable to all types and standards of N2 cylinders
Specifications:
·Type of gas N2
·Model Ketan
·Max. inlet pressure: 200 bar
·Max. flow rate 35 ltrs/min
Outlet pressure up to 5 bar
INLINE FILTERS FOR
INCUBATOR WITH CONNECTORS
Features:
Contain a HEPA filter to remove particulate matter
Studies have proven that Shivani® Inline® Filters are effective
at removing the majority of common air
contaminants (CACs) and volatile organic compounds (VOCs)
FDA 510(k) Cleared
CE Certified & Manufactured in a Clean Room
Patented technology, ISO 13485-2003 Medical Certified
Air Filtration Unit
DAFU 1000
Air Filtration Unit
Daikin's air filtration unit is equipped with 3-stage filtration including 99.99% efficient HEPA filters. It is a portable, with nominal 1000 CFM,
air filtration unit designed to serve small to medium-sized facilities like health care facilities to quickly and inexpensively convert standard
patient rooms to negative pressure isolation rooms. It also helps any conditioned space as a recirculating device that provides equivalent
outdoor air changes (ACH) to eliminate air borne infections.
› Compact Vertical Design with Footprint 0.35 m2 › Casing insulated with Acoustic insulation
› Nominal Airflow 1000 CFM, able to provide 12 ACH in Rooms up to › 3 Stages Filtration with UV lamp
5000 Cubic Feet › HEPA filter auto scan tested as per EN 1822
› Casing 1.0 mm thick prepainted Galvanized steel in RAL 9002 smooth › Indication Lights for unit running and HEPA Filter dirty warning
finish
› Other RAL color options available for the casing
HEPA Filter
High Efficiency
EC Fan
UV Lamp
Carbon Filter
MERV 8 Filter
Castor Wheels
Safety Guards
Provided on unit inlet and discharge in compliance with
OSHA regulations (Occupational Safety and Health Administration)
Unit Construction
Vertical design with unit casing made of 1.0 mm thick prepainted galvanized steel in smooth white finish (RAL9002).
Unit should be insulated with 25mm thick acoustic insula- tion. Insulation should have excellent resistance to bacte- ria and fungi
with low VOC levels.
Safety guards should be provided on the unit Inlet and outlet complying with OSHA regulations. Unit should beportable with
heavy-duty casters for easy movement.
Filtration Stages
Unit should be equipped with 3-stage filtration along with UV lamps.
Prefilter
Prefilters should be available with minimum MERV 8 ef- ficiency classification. Filter efficiency should be docu- mented with
test results from an independent, third-party test laboratory.
Prefilters should have the highest dust-holding capacity (DHC) to ensure longer life for the filter. Filters should be UL-
classified.
Carbon Filter
Carbon filters should be pleated panel type made of ac- tivated carbon media and effective against odors. Filters should be
UL-classified.
HEPA Filter
HEPA filters should be H14 with 99.99% efficiency. Filter media should have a chemical-resistant anodized alu- minum
frame. Filters should be UL-classified. HEPA Filter should be mounted as the last component of the unit up- stream of the
fan.
UV Lamp
High efficiency and high output UV lamp (254 nm) should be provided to inactivate viruses, bacteria and fungi.
Fan
Fan should be EC fans with high-efficiency backward curved impeller made of aluminium blades. Motors should have
minimum IP44 protection.