Professional Documents
Culture Documents
Veichi Solar Catalog
Veichi Solar Catalog
Comprehensive Catalog
-01- -02-
Core Functions of IOT Products and System
Core Function
SI30 Series Solar Pump Inverter
IP65 High Protection | One Key Start/Stop | Smart IOT
Remote control start/stop Big data empowers
Remote parameter modification smart agriculture
-03- -04-
OneKeyToCleanThePump
Product Features
When the pump impeller is blocked due to sediment,
the inverter has built-in water pump cleaning function,
which can clean foreign matter and impurities in the
Block Clean
● Integral aluminum shell, up to 25 years of service life .
ning
Wa t e
● Dry-running : When the inverter detects the output current to low,
protection
-run
r - f u ll
the pump is prevented from running, automatically
Dry
Smart IOT Platform enters the dry protection and alerts A.LuT .
● Over-current : When the running current is greater than the set Over-current
● Real time monitoring .
threshold, the controller will automatically enter the
● Remote control . overcurrent protection and alert the A.oLd .
● On/off-line storage . ● Water-full : Through the terminal control and the liquid level sensor,
● Simultaneous login on web and mobile apps . the inverter can control the start and stop of the water pump
● Support 2G networking , WLAN . according to the liquid level of the water tank .
● EN 61800/EN 61000/EN IEC 61000. ● Single Phase: Single-phase/three-phase quick setting, simple operation .
Hige-efficient MPPT
Unattended, Automatic Operation, Remote Monitoring
P(W)
● MPPT efficiency up to 99.8% .
● Unattended 50 1000W/m²
● The software can quickly detect changes in bus
After the system is installed, there is no need for personnel to be on duty. voltage and then ensure the maximum output 40 800W/m²
-05- -06-
Naming Rules of SI30 Series Model Technical Specification
D1 series: 90~400V DC
D5 series: 300~850V DC
SN Naming Rules Description Boost function D1~D3 series model support extended boost module
1 Product Category “SI” stands for the solar pump inverter Model : SI30-D5-5R5G-R/SI30-D5-7R5G-R/SI30-D5-011G-R
2 Product Series Different series are represented by different two-digit numbers TUV certification Test specification: IEC 62109-1/62109-2
IEC 61683: 1999
3 Voltage Class “D3”: 311Vdc, suitable for the 220~230VAc pumps 3PH/single phase 2. Dormancy function
“D5”: 540Vdc, suitable for the 380~460VAc pumps 3PH Solar pump inverter protection 3. Undervoltage/Overvoltage protection
Build-in relay control Control relay opening and closing according to inverter status
-07- -08-
Dimension Of Solar Pump Inverter Solar Pump Inverter Standard Wiring Diagram
-09- -10-
Product Features
SI23 Series Solar Pump Inverter New Appearance, Narrow Body Structure
380V 2.2kW demonstration
*0 *1 *2 *3
5
PV Specific Functions
4
Smart IOT
1 Product category “SI” stands for the solar pump inverter
● Support GPS positioning, wifi data connection, 2 Product series Different series are represented by different two-digit numbers
offline data storage .
“D1”: 155Vdc, suitable for the 110VAc pumps 3PH/Single phase
● Unattended, real-time, remote control .
“D3”: 311Vdc, suitable for the 220~230VAc pumps 3PH/Single phase
power generation and flow . “D5”: 540Vdc, suitable for the 380~460VAc pumps 3PH
R75G=0.75KW
1R5G=1.5KW
OneKeyToCleanThePump 4 Rated output power
004G=4KW
011G=11KW
When the pump impeller is blocked due to sediment,
the inverter has built-in water pump cleaning function, “ A ” stands for Standard Model without “ A ” stands for Neutral Brand Model
Build-in function
which can clean foreign matter and impurities in the 5
module “ I ” stands for IOT module(Optional)
water pump with one button.
Block Clean
-13- -14-
Technical Specification Dimension Of Solar Pump Inverter
Plastic model
D1 series: 60~400V DC Installation dimension
Overall dimension(mm) ( mm ) Installation
Model aperture
D3 series: 150~450V DC Mounting
aperture W H H1 D D1 W1 W2 H2 A B
Total solar panels Voc input range
SI23-D3-R75G-A
D5 series: 250~780V DC 76 200 192 155 149 65 65 193 5.5 4 3-M4
SI23-D3-1R5G-A
w D1 W1
D5 series: 230~460V AC 0~600Hz 0.75~30KW
H1
SI23-D5-015G-A
Overload capacity 2. 180% rated current 10s
H2
SI23-D5-018G-A 142 383 372 225 219 125 100 372 6 4-M5
SI23-D5-030G-A
172 430 / 225 219 150 150 416.5 7.5 4-M5
MPPT efficiency Up to 99.8%
SI23-T3-037G-A
2. Dormancy function
Installation
Overall dimension(mm) dimension(mm)
Solar pump inverter protection 3. Undervoltage/Overvoltage protection Steel model Model
Installation
aperture
Mounting
aperture
W H H1 D W1 H2
D w1
4. Input/output phase lose protection w
SI23-T3-045G-A
5. Phase-Phase/ Phase to ground short circuit protection SI23-T3-055G-A 240 560 535 310 176 544 4-M6
SI23-T3-075G-A
H2
H
H1
SI23-T3-132G-A
350 738 680 405 220 715 4-M8
SI23-T3-160-A
Build-in relay control Control relay opening and closing according to inverter status
SI23-T3-185-A
Warranty period 18 months SI23-T3-200-A 360 940 850 480 200 914 4-M16
SI23-T3-220-A
SI23-T3-250-A
370 1140 1050 545 200 1110 4-M16
SI23-T3-280-A
-15- -16-
Standard Wiring Diagram
Note: When connect solar panel, both AC input (R, T) and DC input (+, -) is okay, AC input is prefer.
-17- -18-
Product Features
MinimumSize,RemainAlltheFunction Powerful Software Functions Brings Multiple Protection For The Pump
20
● Wide voltage range , support 60V~400V , pumping time
is longer . 10
T
6 8 10 12 14 16
SI23 series inverter with same power The SI22 inverter with the same power can
save about two-thirds of the volume
Auto-Track at any daytime
Concise Style , Tech & Art Drive Forever And Perfect Compatibility With Various Motors
● Shell shape correspond with fan , good for ventilation . ● AM Pump : One-key operation at default setting .
-19- -20-
Naming Rules of SI22 Series Model Technical Specification
1 Product category “SI” stands for the solar pump inverter Solar Pump Inverter Protection 3. Undervoltage/Overvoltage protection
2 Product series Different series are represented by different two-digit numbers 4. Output phase lose protection
1.87
-21- -22-
Product Features
Mini | Economic
Side by side installation, Rail mounting, plug into it Side mounting, sideways
no need to reserve clearance then use it installation if vertical space
is not compatible
Advanced Technology
S.R.M. P.M.S.M.
MPPT Technology
IncidentIrrad.=1000W/㎡
● Efficiency up to 99.8% . 2500
IncidentIrrad.=800W/㎡
IncidentIrrad.=600W/㎡
IncidentIrrad.=400W/㎡
2000 IncidentIrrad.=200W/㎡
Power[W]
1500
1000
500
0
0 70 140 210 280 350
Voltage[V]
-23- -24-
Functional PC Monitor Software
Naming Rules of SI21 Series Model
● Virtual oscilloscope .
SI21 - D1 - 1R5G - A
4
Various Specific Functions
3
PQ
● One-key operation . Minimum Curve
Power
2
● Dormancy、dry run、low speed、minimum
Pump Over
power、pump over current .
Current Pump
1
Clear
● Water fulfilled、output power limit、PQ curve、 Constant
“D1”: 155V DC, Suitable for the 110~220VAc pumps 3PH/Single phase
3 Voltage class
Intelligent IOT
“D3”: 311V DC, Suitable for the 150~230VAc pumps 3PH/Single phase
R75G=0.75KW
4 Rated output power 1R5G=1.5KW
004G=4KW
Build-in function
5 “A” stands for Standard Model without “A” stands for Neutral Brand Model
module
W D D1 series: 60~400V DC
W2 D1 H3
W1 Dimensions (mm) Installation size (mm)
Mounting
安装孔径
Mounting aperture VFD model aperture
W H H1 D D1 W1 W2 H2 W3 H3 H4 D3 series: 150~450V DC
Total solar panels Voc input range
SI21-D1-1R5G-A
75 202 180 163 157 55 10 193 19 6.5 192 3-M4 D5 series: 250~780V DC
SI21-D3-2R2G-A
Solar Pump Inverter Standard Wiring Diagram 1. 150% rated current 60s
2. Dormancy function
Build-in relay control Control relay opening and closing according to inverter status
-27- -28-
Domestic Marketing Services Network
Exclusive Solutions For Water Pump Applications
Dry running protection(No sensor) Dry running protection(One sensor) Water fulfil protection(Dual level sensor)
When the well is empty, the output current will When the downhole liquid level sensor detects When the water level is higher than the high level sensor, it
decrease, when the output current is lower than water shortage, the frequency converter will enters the water full protection. When the water level drops
threshold value, dry running protection will be enter into dry protection to the low level sensor, the inverter starts running
triggered X3 COM
X3/DI X4/DO COM
OFF
1
No water
ON
OFF OFF
(Low Current)
The float switch controls the start and stop according to the Built-in PID algorithm, according to the pressure gauge feedback data to adjust the running frequency,
liquid level to achieve constant pressure water supply
X3 X4 COM
Russia
Denmark
AI GNDCOM 24V Poland Ukraine
Germany
Austria
Italy
Setting Pressure Turkey
Actual Pressure Portugal Spain UnitedStates
OFF Tunisia Jordan Afghanistan
Morocco Egypt
Libya
3.0 Stop 2.6 Algeria
Saudi Arabia
Pakistan
India Bangladesh
Oman Myanmar
Mauritani Mexico
Laos
Sudan Yemen Thailand Dominica
Bar 60Hz Bar Cambodia Philippines
Nigeria Vietnam
SriLanka
Pressure Sensor Uganda Kenya Malaysia
Indonesia
Angola Peru
Namibia
Chile Brazil
Spray irrigation
SouthAfrica Australia
Argentina
Dripping irrigation
-29- -30-