Professional Documents
Culture Documents
S 9062 18
S 9062 18
7400
7200
(kJ/kWh-1.415 x BTU/bhp-hr)
BSFC - BTU/bhp-hr
7000
1000 RPM
6800 900 RPM
800 RPM
6600
750 RPM
6400
6200
1000 1500 2000 2500 3000 3500 4000
BHP
Page 1 of 2
Altitude (ft)
0 2000 3000 3500 4000 5000 6000
40 100 100 100 100 100 100 99.1
60 100.0 100.0 100.0 100.0 100.0 100.0 99.1
80 100.0 100.0 100.0 100.0 100.0 99.1 94.7
100 100.0 100.0 100.0 100.0 98.7 94.3 90.4
110 100.0 100.0 100.0 98.7 96.5 92.1 88.6
120 100.0 100.0 98.7 96.1 93.9 89.9 86.8
131 100.0 100.0 96.1 93.9 91.7 88.2 85.1
NOTES:
Applies to engines with 9.0:1 compression ratio with either ESM or ESM2 control system.
Page 2 of 2