Waukesha gas engines Ratings & Standards

Engine Ratings and Fuel Consumption


ISO Standard (Continuous) Ratings for Model 12V275GL+
130° F (54° C) Auxiliary Water Temperature
180° F (82° C) Jacket Water Temperature

7400

7200
(kJ/kWh-1.415 x BTU/bhp-hr)
BSFC - BTU/bhp-hr

7000
1000 RPM
6800 900 RPM
800 RPM
6600
750 RPM
6400

6200
1000 1500 2000 2500 3000 3500 4000
BHP

RPM 750 800 900 1000


CONTINUOUS BHP 2812 3000 3375 3750

Barometer Ambient Temperature


STANDARD CONDITIONS
29.54 in. Hg. (100 kPa) 77° F (25° C)
DEDUCTIONS Refer to Page 2 for High Altitude and High Ambient Derates.
Dry Natural Gas – 900 Btu/ft3 (35.38 MJ/m3) SLHV; 95 WKI*
FUEL
Refer to S-7884-8 for Full Fuel Specification
EQUIPMENT Engine Equipped with Lube Oil and Cooling Water Pumps
Turbocharged & Intercooled with 130° F (54° C) Intercooler Water
ENGINE DATA
9.0:1 Compression Ratio

Page 1 of 2

Engine Ratings & Fuel Consumption Ref.


Model 12V275GL+ EN: 158887
S
130° F (54° C) Auxiliary Water Temperature DATE: 11/16
180° F (82° C) Jacket Water Temperature 9062-18
Waukesha gas engines Ratings & Standards

12V275GL+ Altitude and Temperature Derates

Altitude (ft)
0 2000 3000 3500 4000 5000 6000
40 100 100 100 100 100 100 99.1
60 100.0 100.0 100.0 100.0 100.0 100.0 99.1
80 100.0 100.0 100.0 100.0 100.0 99.1 94.7
100 100.0 100.0 100.0 100.0 98.7 94.3 90.4
110 100.0 100.0 100.0 98.7 96.5 92.1 88.6
120 100.0 100.0 98.7 96.1 93.9 89.9 86.8
131 100.0 100.0 96.1 93.9 91.7 88.2 85.1

NOTES:
Applies to engines with 9.0:1 compression ratio with either ESM or ESM2 control system.

1. Engine controlled to an exhaust NOx output of 0.5 g/bhp-hr at ESM timing.


2. ISO Standard (continuous) power ratings conform to ISO 3046/1, latest version, with a mechanical efficiency of 90% and
auxiliary water temperature, Tcra, of 130° F (54° C) limited to ± 10° F (± 5.5° C).
*Trademark of INNIO. All other trademarks are the property of their respective owners.

Page 2 of 2

Engine Ratings & Fuel Consumption Ref.


Model 12V275GL+ EN: 158887
S
130° F (54° C) Auxiliary Water Temperature DATE: 11/16
180° F (82° C) Jacket Water Temperature 9062-18