DRAWING LIST:

COYOTE ELEMENTARY GENERAL ARRANGEMENT


G0.00 DRAWINGS LIST
G0.01 GENERAL NOTES
8131 156 St, Surrey, BC V3S 3R4 G0.02 ASSEMBLIES AND LEGEND
G0.03 WINDOW & DOOR SCHEDULE
2001383 G0.04 WINDOW SCHEDULE

A1.00 SITE PLAN


A1.01 FLOOR PLAN
A2.00 ELEVATIONS

DETAILS
A5.101 EXTERIOR INSULATION WALL SYSTEM
ISOMETRIC
A5.102 CORNER DETAILS
A5.103 BASE OF WALL AT GRADE
A5.105 LIGHT FIXTURE DETAILS
A5.106 HOSE BIB DETAILS
A5.107 STUCCO TO BRICK TRANSITION
A5.201 WINDOW INSTALLATION ISOMETRIC
A5.202 WINDOW HEAD AND SILL
A5.203 TYPICAL WINDOW JAMB
A5.204 WINDOW JAMB AT CORNER
A5.208 HOLLOW METAL DOOR HEAD
A5.209 HOLLOW METAL DOOR THRESHOLD
A5.210 HOLLOW METAL DOOR JAMB
A5.401 SLOPED ROOF TO ADJACENT WALL GUTTER
DETAIL
A5.402 WALL TO SLOPED ROOF GUTTER DETAIL
A5.403 SKYLIGHT DETAIL
A5.404 SKYLIGHT DETAIL
A5.405 SKYLIGHT DETAIL
A5.406 METAL CLADDING TO METAL ROOF DETAIL
A5.407 SLOPED METAL CANOPY DETAIL
A5.408 SCUPPER DETAIL
A5.409 MISCELLANEOUS DETAILS
A5.410 UNINSULATED WALL DETAILS
A5.411 DOWNSPOUT DETAIL
A5.412 LOUVER DETAIL
A5.413 GUTTER DETAIL ISOMETRIC

ISSUED FOR 100%


FEBRUARY 03, 2022

SUITE 310 - 4321 STILL CREEK DR.


BURNABY BC, V5C 6S7
604-454-0402 (tel.) 604-454-0403 (fax)
www.morrisonhershfield.com
1.1. DRAWINGS ARE TO BE READ IN CONJUNCTION WITH WRITTEN SPECIFICATIONS. RELATED WORK.
1.19. NOTIFY THE CONSULTANT IMMEDIATELY AND REQUEST A REVIEW IF ANY
1.2. DO NOT SCALE DRAWINGS. CONTRACTOR IS TO VERIFY DIMENSIONS ON SITE. ADDITIONAL DAMAGE OF EXISTING AREAS OUTSIDE THE CONTRACT IS
DISCOVERED. DO NOT COMMENCE ANY RELATED OR NEARBY WORK WITHOUT
1.3. IF ANY DISCREPANCIES IN THE DOCUMENTS ARE FOUND, REQUEST THE CONSULTANTS APPROVAL.
CONSULTANT TO CLARIFY THE DISCREPANCIES PRIOR TO COMMENCING ANY
RELATED WORK. 1.20. CONTRACTOR IS RESPONSIBLE TO PATCH ALL DAMAGE CAUSED BY SCOPE OF
WORK AT ALL EXISTING INTERIOR AREAS TO MATCH EXISTING. (PAINT READY).
1.4. DRAWINGS AND PLANS PREPARED ARE BASED ON INFORMATION TAKEN FROM
ARCHITECTURAL DRAWINGS BY YONEDA & ASSOCIATES DATED 1990. 1.21. REPLACE ALL EXTERIOR LIGHT FIXTURES WITHIN AREA OF WORK. ADJUST THE
CONDUIT TO THE NEW WALL THICKNESS.
1.5. BASED ON THE REVIEW OF EXISTING DRAWINGS, THE BUILDINGS ARE NOT
SPRINKLERED. 1.22. CONTRACTOR TO ENSURE THAT EXISTING STRUCTURE AND SERVICES ARE NOT
DAMAGED THROUGH DEMOLITION AND OTHER CONSTRUCTION ACTIVITIES.
1.6. FORMED FLASHING TO MAINTAIN MINUMUM 10% SLOPE UNLESS OTHERWISE CONTRACTOR NOT TO OVERLOAD STRUCTURE AND ENSURE ADEQUATE
NOTED. PRECAUTIONS ARE TAKEN NOT TO DAMAGE EXISTING STRUCTURE STAT IS TO
REMAIN IN PLACE.
1.7. ALL TERMINATIONS IN METAL FLASHING TO HAVE FOLDED END DAMS.
FLASHING DOWNTURN LEG TO COVER CLADDING MINIMUM 2" UNLESS 1.23. COLOUR, TEXTURE & SHAPE FOR NEW WINDOWS, METAL FLASHING AND
OTHERWISE NOTED. ALL JOINTS TO BE S-LOCK OR STANDING SEAM. GUARDRAILS ARE TO MATCH WITH NEW CONSTRUCTION ADDITION.

1.8. TYPICAL SEALANT JOINT TO BE MINIMUM 3/8" WIDE UNLESS NOTED OTHERWISE 1.24. NOTIFY THE CONSULTANT IMMEDIATELY AND REQUEST A REVIEW IF ANY
ADDITIONAL DAMAGE OF EXISTING AREAS OUTSIDE THE CONTRACT IS
1.9. INSTALL INSECT SCREEN AT TOP AND BOTTOM OF CLADDING CAVITY SPACE. DISCOVERED. DO NOT COMMENCE ANY RELATED OR NEARBY WORK WITHOUT
CONSULTANT'S APPROVAL. 3 Issued for 100% 2022-02-03
1.10. INSTALL METAL PERFORATED SCREEN AT THE BOTTOM OF CAVITY WALL AT THE 2 Issued for 90% Review 2021-3-05

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\G0.00.dwg


VISIBLE LOCATIONS. 1.25. CLEAN ALL AREAS AFFECTED BY THE WORK TO THE SATISFACTION OF THE 1 Issued for 50% Review 2020-12-10
OWNER UPON PROJECT COMPLETION.
Version Description YYYY-MM-DD
1.11. SEALANT TO BE INSTALLED AROUND INTERIOR PERIMETERS OF
WINDOWS/DOORS FOR AIR BARRIER CONTINUITY. SEALANT TO BE INSTALLED Stamp
1.26. ALL MECHANICAL, ELECTRICAL AND OTHER ITEMS AFFECTED BY THE
AROUND EXTERIOR PERIMETER OF ALL CLADDING PENETRATIONS FOR RESTORATION OF WALLS, MUST BE REPLACED IN ACCORDANCE WITH
CONTINUITY OF THE MOISTURE SHEDDING SURFACE. CURRENT APPLICABLE CODES AND USING GOOD PRACTICE.

1.12. OPERABLE VENTS ARE TO BE LOCATED IN SAME POSITION AS THEY OCCUR 1.27. CLEAN ALL AREAS AFFECTED BY THE WORK TO THE SATISFACTION OF THE
NOW EXCEPT WHERE INDICATED OTHERWISE. OWNER UPON PROJECT COMPLETION.

1.13. CONFIRM NUMBER AND LOCATION OF EXISTING DRAINS AND OVERFLOW 1.28. ALL MECHANICAL, ELECTRICAL AND OTHER ITEMS AFFECTED BY THE
SCUPPERS, RWL, DOWNSPOUTS, ETC. CONFIRM SLOPE OF LOW SLOPE RESTORATION OF WALLS, MUST BE REPLACED IN ACCORDANCE WITH
ROOFS. ADVISE CONSULTANT BEFORE PROCEEDING WITH MEMBRANE CURRENT APPLICABLE CODES AND USING GOOD PRACTICE.
INSTALLATION.
1.29. EXISTING LOCKING AND FOB SYSTEM TO BE REINSTALL ON THE NEW DOORS.
1.14. CONTRACTOR IS RESPONSIBLE FOR SAFETY ON THE JOB SITE DURING GENERAL CONTRACTOR TO CONTACT THE SAME SUPPLIER TO COORDINATE
CONSTRUCTION. THE WORK REQUIRED TO REINSTALL BACK THE FOB SYSTEM ON THE NEW COYOTE CREEK
DOOR. AUTOMATED DOOR OPENING TO BE REMOVE AND REINSTALLED. ELEMENTARY SCHOOL
1.15. CONNECT ALL DRAINS, GUTTERS AND SCUPPERS TO THE RWL.
1.30. REMOVE AND REPLACE ALL EXISTING SCHOOL SIGNS.
1.16. CONTRACTOR TO ALLOW FOR DETAILING ALL OF EXISTING VENTS, HOSE BIBS, MH No. 2001383.00
LIGHTS, EXTERIOR OUTLETS AND OTHER PENETRATIONS THAT MAY NOT BE
INCLUDED ON ELEVATION DRAWINGS.
GENERAL NOTES
1.17. CONTRACTOR HAS TO REPORT TO ARCHITECT/ENGINEER ALL NEW AND
EXISTING PENETRATIONS THROUGH SLABS, FIRE WALLS, AND BEARING Scale
WALLS. CONTRACTOR TO OBTAIN APPROVAL FOR ALL FIRE-RATED SYSTEM NTS
FOR PENETRATIONS.
Designed Drawn Checked
1.18. IF ANY DISCREPANCIES IN THE DOCUMENTS ARE FOUND, REQUEST THE B2M / AC AS / B2M AC
CONSULTANT TO CLARIFY THE DISCREPANCIES PRIOR TO COMMENCING ANY DWG No. Version Date
G0.01 3 2020-12-04
DETAIL HATCHING LEGEND ASSEMBLIES

RIGID & SEMI-RIGID INSULATION W1 NEW WALL ASSEMBLY ER1 EXISTING FLAT ROOF ASSEMBLY
1. NEW CORRUGATED METAL PANEL 1. EXISTING SBS MEMBRANE
2. NEW 2" INSULATION WITH 2-1/2" 2. EXISTING 2" RIGID INSULATION/Z-GIRT
THERMAL CLIPS 3. EXISTING VAPOUR RETARDER
3. NEW VAPOUR PERMEABLE 4. EXISTING GYPSUM SHEATHING
BATT INSULATION
SELF-ADHESIVE MEMBRANE 5. EXISTING METAL DECKING
4. NEW EXTERIOR GYPSUM 6. EXISTING STEEL FRAMING
SHEATHING 7. EXISTING DROP CEILING PANEL
INTERIOR GYPSUM WALLBOARD 5. EXISTING STEEL STUD
THICKNESS AS SPECIFIED 6. EXISTING BATT INSULATION
7. EXISTING VAPOUR BARRIER
8. EXISTING GYPSUM BOARD

SYMBOLS LEGEND
ASSEMBLY TYPE ER2 EXISTING METAL ROOF ASSEMBLY
1
REFERENCE 1. EXISTING METAL ROOFING
2. EXISTING 2" INSULATION
W1 WINDOW / DOOR REF 3. EXISTING VAPOUR RETARDED
4. EXISTING GYPSUM SHEATHING
- 5. EXISTING STEEL DECKING 3 Issued for 100% 2022-02-03
REVISION TAG 6. EXISTING OPEN WEB STEEL JOIST 2 Issued for 90% Review 2021-3-05

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\G0.00.dwg


1 Issued for 50% Review 2020-12-10

REVISIONS CLOUD Version Description YYYY-MM-DD


Stamp

ABBREVIATIONS LIST LINETYPE LEGEND TO DETAILS EW1 EXISTING STUCCO ASSEMBLY


1. EXISTING STUCCO
A/M AIR/MOISTURE BARRIER
2. EXISTING SHEATHING PAPER
C/W COMPLETE WITH SELF ADHESIVE MEMBRANE
3. EXISTING GYPSUM SHEATHING
DWG. DRAWING
4. EXISTING STEEL STUD
EXIST. EXISTING FILTER FABRIC 5. EXISTING BATT INSULATION
GWB GYPSUM WALL BOARD
6. EXISTING VAPOUR BARRIER
MIN. MINIMUM SHEATHING MEMBRANE 7. EXISTING GYPSUM BOARD
N.I.C. NOT IN CONTRACT
O.C. ON CENTRE DRAINAGE MATT
PT PRESSURE TREATED
COYOTE CREEK
REV. REVERSED
RE&RE REMOVE & REINSTALL
BREATHER BOARD EW2 EXISTING BRICK ASSEMBLY (NOT IN SCOPE) ELEMENTARY SCHOOL
R.O. ROUGH OPENING 1. EXISTING BRICK
R.W.L. RAINWATER LEADER WATERPROOFING MEMBRANE
2. EXISTING AIR SPACE
MH No. 2001383.00
S.A.M. SELF ADHESIVE MEMBRANE 3. EXISTING SHEATHING PAPER
S.M. SHEATHING MEMBRANE SBS MEMBRANE 4. EXISTING STEEL STUD
SIM. SIMILAR 5. EXISTING BATT INSULATION ASSEMBLIES AND LEGENDS
S.O.G. SLAB-ON-GRADE WEATHER RESISTIVE BARRIER 6. EXISTING VAPOUR BARRIER
T&G TONGUE & GROOVE 7. EXISTING GYPSUM
EXISTING MEMBRANE Scale
T.B.C. TO BE CONFIRMED
T.O.W. TOP OF WALL EXISTING COMPONENT NTS
TYP. TYPICAL Designed Drawn Checked
U.N.O. UNLESS NOTED OTHERWISE METAL FLASHING
B2M / AC AS / B2M AC
ADD. ADDENDUM
DWG No. Version Date
G0.02 3 2020-12-04
5'-11" 5'-11" 4'-1"
7'-11"

2'-6"
2'-5"

2'-5"

2'-0"

4'-0"
4'-0"

4'-0"

5'-812"
SECURITY SHUTTER (TYP.)

5'-9"
W1 W2 W3 W4 W5
THERMALLY BROKEN

4'-0"
4'-0"

4'-0"
ALUMINUM FRAMED (TYP.)

QUANTITY: 18 QUANTITY: 16 QUANTITY: 2 QUANTITY: 2 QUANTITY: 10

1'-0"
FLR (TYP.)
11'-112"

8'-3"
5'-6"

2'-7" 5'-10"

4'-1"
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\G0.00.dwg


1 Issued for 50% Review 2020-12-10
4'-2"

4'-0"
Version Description YYYY-MM-DD

4'-1"
Stamp
5'-11"

5'-9"
4'-0"

4'-0"

2'-9"
W6 W7 W8 W9 W10
1'-0"

QUANTITY: 2 QUANTITY: 1 QUANTITY: 10 QUANTITY: 2 QUANTITY: 2


5'-10" 5'-10"
6'-37 8" 3'-0" 3'-37 8"

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00
6'-0"

6'-0"

6'-83 4"

6'-83 4"
6'-718"

WINDOW SCHEDULE

Scale
1/4" = 1'-0"
1'-0"

1'-0"

W11 W12 D1 D2 D3 Designed Drawn Checked


B2M / AC AS / B2M AC

QUANTITY: 2 QUANTITY: 2 QUANTITY: 5 QUANTITY: 4 QUANTITY: 18 DWG No.


G0.03
Version
3
Date
2020-12-04
12'-0" 12'-0"

1'-6"

1'-6"
4'-6" 6'-0" 6'-0"

4'-6"
4'-0" 4'-0"

2'-0" 2'-0"
W13 W14

QUANTITY: 2 QUANTITY: 3
12'-11 4"

12'-11 4"
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\G0.00.dwg


1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

WINDOW SCHEDULE

Scale
1/4" = 1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
G0.04 3 2020-12-04
A B C D E F G H I

NOTES
Do not scale drawings. Contractor is to verify dimensions on site.

1 1

NORTH

2 2

3 3

CB CB

Plotted 2022-02-02 2:45 PM by Anastasiia Sergeyenko


3 2022-02-03 ISSUED FOR 100% CLIENT REVIEW

2 2021-03-05 ISSUED FOR 90% CLIENT REVIEW

1 2020-08-18 ISSUED FOR 50% CLIENT REVIEW

YYYY-MM-DD SUBMISSION INFORMATION

DISCLAIMER:
THIS DRAWING IS PROTECTED BY COPYRIGHT LAW, AND SHOULD NOT BE
REPRODUCED IN ANY MANNER, OR FOR ANY PURPOSE, EXCEPT BY WRITTEN
PERMISSION OF MORRISON HERSHFIELD. CONTRACTOR SHALL VERIFY AND
BE RESPONSIBLE FOR ALL DIMENSIONS AND REPORT ANY ERRORS AND/OR
OMISSIONS TO MORRISON HERSHFIELD.

PROFESSIONAL SEALS

Last Saved: 2022-02-01 2:28 PM by ASergeyenko


X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\A1.00 cpypte.dwg
5

1 SITE PLAN
-
SCALE: NTS

Suite 310, 4321 Still Creek Drive


Burnaby, BC V5C 6S7
Tel: 604 454 0402
PROJECT

COYOTE CREEK
ELEMENTARY SCHOOL
DRAWING

SITE PLAN

DESIGN DATE SCALE


WR 2022-02-02 NTS
DRAWN PROJECT NO.
SW 200138300
CHECKED DRAWING NO VERSION
- A1.00
APPROVED 3

A B C D E F G H I
A B C D E F G H I

NOTES
Do not scale drawings. Contractor is to verify dimensions on site.

NORTH

1 1

WALLS NOT NOT IN SCOPE


IN SCOPE

WALL IN SCOPE
BASE SCOPE

west
wing
WALLS IN
2 SCOPE 2

NORTH

WALLS NOT
IN SCOPE

north NORTH
3

wing 3

south

Plotted 2022-02-02 2:45 PM by Anastasiia Sergeyenko


3 2022-02-03 ISSUED FOR 100% CLIENT REVIEW

2 2021-03-05 ISSUED FOR 90% CLIENT REVIEW

wing 2
1 2020-08-18

YYYY-MM-DD
ISSUED FOR 50% CLIENT REVIEW

SUBMISSION INFORMATION

DISCLAIMER:
THIS DRAWING IS PROTECTED BY COPYRIGHT LAW, AND SHOULD NOT BE
REPRODUCED IN ANY MANNER, OR FOR ANY PURPOSE, EXCEPT BY WRITTEN
PERMISSION OF MORRISON HERSHFIELD. CONTRACTOR SHALL VERIFY AND
BE RESPONSIBLE FOR ALL DIMENSIONS AND REPORT ANY ERRORS AND/OR
OMISSIONS TO MORRISON HERSHFIELD.

PROFESSIONAL SEALS

Last Saved: 2022-02-01 2:28 PM by ASergeyenko


1

NORTH
SOUTH EAST

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\A1.00 cpypte.dwg
5
WING

Suite 310, 4321 Still Creek Drive


Burnaby, BC V5C 6S7
Tel: 604 454 0402
PROJECT

COYOTE CREEK
ELEMENTARY SCHOOL
DRAWING

GROUND FLOOR PLAN


1
-
GROUND FLOOR PLAN
SCALE: 1/16"=1'-0"
EAST
6

DESIGN DATE SCALE


WR 2022-02-02 1/16" = 1'-0"
DRAWN PROJECT NO.
SW 200138300
CHECKED DRAWING NO VERSION
- A1.01
APPROVED 3

A B C D E F G H I
A B C D E F G H I

NOTES
Do not scale drawings. Contractor is to verify dimensions on site.
The original building drawings were prepared by Downs/Archambault & Partners/
Planenrs dated September 7, 1993.

1 1

NOT IN SCOPE
NEW
SKYLIGHTS

WALL IN SCOPE
BASE SCOPE

2 2

1 WEST ELEVATION
-
SCALE: 3/32"=1'-0"

NEW
NEW
SKYLIGHTS
SKYLIGHTS

3 3

Plotted 2022-02-02 2:45 PM by Anastasiia Sergeyenko


3 2022-02-03 ISSUED FOR 100% CLIENT REVIEW

1 SOUTH ELEVATION 2 2021-03-05 ISSUED FOR 90% CLIENT REVIEW


-
SCALE: 3/32"=1'-0"
1 2020-08-18 ISSUED FOR 50% CLIENT REVIEW

YYYY-MM-DD SUBMISSION INFORMATION

DISCLAIMER:
THIS DRAWING IS PROTECTED BY COPYRIGHT LAW, AND SHOULD NOT BE
REPRODUCED IN ANY MANNER, OR FOR ANY PURPOSE, EXCEPT BY WRITTEN
PERMISSION OF MORRISON HERSHFIELD. CONTRACTOR SHALL VERIFY AND
BE RESPONSIBLE FOR ALL DIMENSIONS AND REPORT ANY ERRORS AND/OR
OMISSIONS TO MORRISON HERSHFIELD.

PROFESSIONAL SEALS

Last Saved: 2022-02-01 2:28 PM by ASergeyenko


X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\A1.00 cpypte.dwg
5

Suite 310, 4321 Still Creek Drive


Burnaby, BC V5C 6S7
Tel: 604 454 0402
PROJECT

COYOTE CREEK
ELEMENTARY SCHOOL
DRAWING

ELEVATIONS

DESIGN DATE SCALE


WR 2022-02-02 3/32" = 1'-0"
DRAWN PROJECT NO.
SW 200138300
CHECKED DRAWING NO VERSION
- A.200
APPROVED 3

A B C D E F G H I
NOTE:
1. RELOCATE EXISTING CABLE AND
ELECTRICAL CONDUITS TO BE
EXISTING POLYETHYLENE SHEET
CONCEALED IN WALL ASSEMBLY.
(VB) TO REMAIN
2. FASTENERS ARE TO BE POWDER
COATED TO MATCH THE CLADDING,
BE INSTALLED PER
EXISTING STEEL STUD FRAMING C/W
MANUFACTURER'S REQUIREMENTS
BATT INSULATION TO REMAIN
AND ALIGN VERTICALLY AND
HORIZONTALLY
1
NEW 2" GYPSUM SHEATHING TO
REMAIN

2" OF SEMI-RIGID INSULATION (ROXUL


CAVITY ROCK OR APPROVED ALTERNATE)

VERTICALLY ORIENTED CORRUGATED


METAL CLADDING

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
VAPOUR PERMEABLE SELF-ADHERED 3 Issued for 100% 2022-02-03
SHEATHING MEMBRANE (WRB/AB) 2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10

HORIZONTALLY ORIENTED 2" HAT 1 Version Description YYYY-MM-DD


TRACKS - ATTACHED TO VERTICAL Stamp
RAIL

VERTICAL RAIL - ENGINEERED BY


CLIP SYSTEM ENGINEER

COYOTE CREEK
ELEMENTARY SCHOOL
INTERMITTENT CLIPS LOCATED OVER
STUDS MH No. 2001383.00

EXTERIOR INSULATION WALL


SYSTEM ISOMETRIC
Scale
NOT TO SCALE
Designed Drawn Checked
1 CORRUGATED CLADDING WALL ASSEMBLY ISOMETRIC B2M / AC AS / B2M AC
A5.101 SCALE: N.T.S.
DWG No. Version Date
A5.101 3 2020-12-04
PRE-FINISHED METAL J-TRIM
INSTALLED VERTICALLY AND
HORIZONTALLY AT ALL TERMINATIONS
IN THE CORRUGATED METAL PANEL
WHEN INSTALLED HORIZONTALLY THE
TRIM IS TO BE PROVIDED WITH
DRILLED WEEPS INSTALLED @ 24" O/C
OUTSIDE CORNER TRIM WITH A MINIMUM OF 2 WEEPS PER
TRIM PIECE.
DO NOT BUTT FURRING AT
CORNER TO ALLOW FOR
DRAINAGE

BUTT METAL J-TRIM AT


CORNER

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
PRE-FINISHED METAL
FLASHING

3 Issued for 100% 2022-02-03


2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

COYOTE CREEK
ELEMENTARY SCHOOL

1 INSIDE CORNER DETAIL 2 OUTSIDE CORNER DETAIL


MH No. 2001383.00
A5.102 SCALE: 3"=1'-0" A5.102 SCALE: 3"=1'-0"

CORNER DETAILS

Scale

Designed Drawn Checked


B2M / AC AS / B2M AC
DWG No. Version Date
A5.102 3 2020-12-04
NOTE:
1. REMOVE NATIVE BACKFILL TO
ACCOMMODATE NEW 12"x6" RIVER
WASHED STONE BORDER.
2. FILTER FABRIC TO BE INSTALLED
BETWEEN STONE BORDER AND
NATIVE BACKFILL.
3. DISCONNECT AND
RECONNECT/RELOCATE EXISTING
SPRINKLER LINES, AS REQUIRED, TO
ACCOMMODATE REHABILITATION.

SHEATHING MEMBRANE (WRB/AB)


LAPPED OVER SAM STRIPPING AND
METAL FLASHING
SAM (AB) TERMINATED ON FACE OF
FOUNDATION WALL

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
PRE-FINISHED METAL FLASHING C/W
HEMMED EDGE AND 3 4" END DAMS
TO FULLY CONCEAL SAM STRIPPING
3 Issued for 100% 2022-02-03
INSECT SCREEN 2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
PRE-FINISHED METAL J-TRIM C/W
Version Description YYYY-MM-DD
DRILLED WEEPS @ 24" O/C
Stamp

OVERLAP SAM ONTO CUT LANDSCAPING OR PAVEMENT BACK 1'


WATERPROOFING BACK AND 3' DEEP. THEN BACKFILL WITH
MINIMUM 4" DRAINAGE ROCK. COVER WITH PAVERS.

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

BASE OF WALL AT GRADE

1 BASE OF WALL AT GRADE - SECTION WATERPROOF CONCRETE CURB AND Scale


A5.103 EXTEND 8" PAST COLD JOINT. COVER WITH 3"=1'-0"
SCALE: 3"=1'-0"
DRAIN MAT. Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.103 3 2020-12-04
NOTE:
1. EXISTING LIGHT FIXTURES ARE TO
" BE REMOVED AND REPLACED WITH
12 3" NEW.
STEP 1 STEP 2
2. DETAIL 2 IS CONCEPTUAL AND
DESCRIBES DESIGN INTENT IT DOES
3"
" NOT PURPORT TO SHOW ALL
12
CONDITIONS.
3. EXTERIOR OUTLETS ARE TO BE GFI,

3"
MEET THE CURRENT REQUIREMENTS
1 OF THE ELECTRICAL CODE AND TO
4 BE PROVIDED WITH A CODE
COMPLIANT EXTERIOR COVER.
4. THE REQUIRED LABOUR TO INSTALL

12"
THE EXTERIOR LIGHT FIXTURES TO
BE PART OF THE BASE CONTRACT.
5. A CASH ALLOWANCE HAS BEEN
PROVIDED FOR THE PURCHASE OF
110 EXTERIOR FIXTURES.
5

12"
2 3
SAM TERMINATED WITH A
BEAD OF MASTIC (TYP.)

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
1. INSTALL WRB PRE-STRIP. SIZE TO BE MIN 12" EACH 4. APPLY SAM AT TOP AND SIDES OF
PRE-FINISHED METAL J-TRIM ELECTRICAL BOX AND EXTEND ONTO
DIRECTION. CUT HOLE FOR WIRE.
C/W MIN. 2 WEEPS WRB IN SHINGLE-LIKE FASHION. SEAL
2. INSTALL SAM PATCH OVER WRB PRE-STRIP. EXTEND
EDGES MIN 3" BEYOND WIDTH AND HEIGHT OF ALL PINHOLES WITH SAM PATCHES.
PRE-FINISHED METAL 3 Issued for 100% 2022-02-03
ELECTRICAL BOX. CUT HOLE FOR WIRE. 5. SEAL ALL SAM EDGES, TYP.
FLASHING 2 Issued for 90% Review 2021-3-05
3. SEAL WIRE PENETRATION WITH SEALING COMPOUND
4. INSTALL ELECTRICAL BOX OR EXTENSION. SHIM BACK OF 1 Issued for 50% Review 2020-12-10
GASKET BEHIND FACE PLATE
BOX TO SUIT DRAINED CAVITY ASSEMBLY. Version Description YYYY-MM-DD
STRIP OF SAM (WRB/AB) AT STEP 4 Stamp
TOP AND SIDES STEP 3 9

REMOVE AND REPLACE


EXISTING EXTERIOR LIGHT
FIXTURES
SEAL WIRE PENETRATION
WITH MASTIC 7

ELECTRICAL BOX - COLOUR


TO MATCH CLADDING
SAM (AB) BEHIND ELECTRICAL
BOX
COYOTE CREEK
P.T. 2x BLOCKING - SIZE TO BE
DETERMINED IN MOCK-UP 6 ELEMENTARY SCHOOL
ADD ADDITIONAL HAT TRACKS 8
AS REQUIRED 9. LAP FIELD WRB OVER PRE-STRIP AT MH No. 2001383.00
6. TUCK FIELD WRB UNDER WRB PRE-STRIP AT SILL HEAD. SEALANT BETWEEN FIELD WRB
7. TUCK FIELD WRB UNDER PRE-STRIP AT JAMBS AND SAM AT HEAD, TAPE SEAMS.
8. TAPE WRB PRE-STRIP TO FIELD WRB AT SILL & LIGHT FIXTURE DETAILS
JAMBS
Scale
AS NOTED
1 EXTERIOR LIGHT FIXTURE - SECTION DETAIL 2 LIGHT FIXTURE MEMBRANE INSTALLATION SEQUENCE Designed Drawn Checked
A5.105 SCALE: 3"=1'-0" A5.105 SCALE: N.T.S. B2M / AC AS / B2M AC
DWG No. Version Date
A5.105 3 2020-12-04
NOTE:
STEP 2 PIPE PERIMETER + 2" 1. SIZE OF TRIM TO BE CONFIRMED
2" 2" 2" 2" 2" 2" DURING MOCK-UP
2. EXISTING HOSE BIBS ARE TO BE
REPLACED WITH NEW FROST-FREE
"
12 HOSE BIBS.
STEP 1 3. UNIT RATE FOR INSTALLATION OF
POTABLE PIPING IN EXTERIOR

12"
" WALLS.
12

5"
1"
PIECE 1
CUT LINE

12"
FOLD LINE

4"

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
PIECE 2

2"
CUT HOLE FOR PIPE
2. CUT TWO PIECES OF SAM AS 3 Issued for 100% 2022-02-03
PRE-FINISHED METAL FLASHING 1. WRB IF PRE-STRIPPED, SHOWN.
2 Issued for 90% Review 2021-3-05
SIZE TO BE MIN. 12" EACH
SAM TERMINATED WITH A BEAD DIRECTION. 1 Issued for 50% Review 2020-12-10
OF MASTIC (TYP.) OUTLINE OF WRB
Version Description YYYY-MM-DD
STEP 4 PRE-STRIP (IF
APPLICABLE) Stamp
HOSE BIB TO BE AFFIXED TO STEP 3 3. INSTALL SAM PIECE 1
SHEATHING ONTO WRB AND PIPE
STRIP OF SAM (WRB/AB) OVER PENETRATION.
PIPE - ALL AROUND POSITION SAM SUCH
INSTALL GEAR CLAMP AROUND THAT LAP JOINT IS AT
SAM TO ENSURE ADEQUATE THE BOTTOM
ADHESION TO PIPE
EXISTING HOSE BIB TO BE REPLACED
WITH NEW FROST-FREE HOSE BIB -
EXTEND EXISTING COPPER PIPE TO 4. INSTALL SAM PIECE 2
ACCOMMODATE AND OFFSET FROM
PIECE 1 5. CONTINUOUS
GASKET BEHIND FACE PLATE COYOTE CREEK
SEALANT BEAD -
P.T. 2x BLOCKING - SIZE TO BE
5. APPLY SEALING
INSTALL PRIOR TO
ELEMENTARY SCHOOL
COMPOUND AROUND
DETERMINED IN MOCK-UP EDGE OF SAM WRB INSTALLATION
MH No. 2001383.00
ADD ADDITIONAL HAT TRACKS 6. LAP FIELD WRB OVER SAM
AS REQUIRED AND LOWER SHEATHING
MEMBRANE (LOWER SHEATHING HOSE BIB DETAILS
MEMBRANE NOT SHOWN)

Scale
AS NOTED
Designed Drawn Checked
1 HOSE BIB - SECTION DETAIL 2 PIPE PENETRATION SAM INSTALLATION ISOMETRIC B2M / AC AS / B2M AC
A5.106 SCALE: 3"=1'-0" A5.106 SCALE: N.T.S.
DWG No. Version Date
A5.106 3 2020-12-04
NEW SAM TO LAP OVER
EXISTING A MIN OF 3"
NEW SHEATHING INSECT SCREEN

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
NEW FLASHING

3 Issued for 100% 2022-02-03


LEAVE EXISTING WATERPROOFING 3" min 2 Issued for 90% Review 2021-3-05
MEMBRANE EXTENDED A MIN OF 3" 1 Issued for 50% Review 2020-12-10
ABOVE THE BRICK CLADDING
Version Description YYYY-MM-DD
EXISTING SHEATHING Stamp

COYOTE CREEK
ELEMENTARY SCHOOL
STUCCO TO
1 BRICK TRANSITION MH No. 2001383.00
-
SCALE: 3"=1'-0"

STUCCO TO BRICK
TRANSITION
Scale
AS NOTED
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.107 3 2020-12-04
NOTE:
1. EXISTING INTERIOR TRIMS TO BE
REMOVED AND REPLACED WITH
NEW - NEW TRIM TO BE PRIMED AND
PAINTED WHITE.
2. REFER TO DETAILS FOR TRIM
FOLD BOOT AT

6"
CONFIGURATION.
INSIDE CORNER,
2 3" DO NOT CUT
1a

3 4

3"
5
SHEATHING MEMBRANE
STARTER STRIP APPLY SEALANT AT ALL SEAMS
CUTBACK EXISTING TRIM TO
ACCOMMODATE WINDOW
1b INSTALLATION

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
1a) REMOVE INTERIOR FINISHES FROM
LAP JAMB SELF-ADHESIVE MEMBRANE
WINDOW/DOOR OPENINGS TO FACE OF WALL APPLY SELF-ADHESIVE INSTALL GUSSETS TO
1 2 INSTALL METAL 3 4 5 BOOT OVER SILL MEMBRANE AND
1b) INSTALL SHEATHING MEMBRANE STARTER ANGLE AT SILL MEMBRANE SILL. PREVENT PIN HOLES.
GUSSET AT CORNER
STRIP AT SILL. 3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
SEALANT ALONG TOP EDGE ABOVE
INSTALL SHEATHING MEMBRANE 1 Issued for 50% Review 2020-12-10
FLASHING, AND DOWN TERMINATIONS
LAPPED OVER HEAD STARTER STRIP
Version Description YYYY-MM-DD
AND FLASHING
Stamp
TAPE ALL JOINTS IN 7b
SHEATHING MEMBRANE INSTALL HEAD FLASHING
(TYP.) TAPE TERMINATIONS

2'
END DAM
INSTALL FIELD SHEATHING MEMBRANE
AT JAMBS AND SILL, LAPPING UNDER
STARTER STRIPS. TAPE ALL SEAMS.
6
INSTALL SHEATHING
MEMBRANE STRIP AT
COYOTE CREEK
STARTER INTERIOR PERIMETER ELEMENTARY SCHOOL
HEAD AND JAMBS. 8
STRIP SEALANT, FOR AIR
SHEATHING MEMBRANE
SUB-SILL TO LAP OVER BARRIER CONTINUITY
MEMBRANE SELF-ADHESIVE
MH No. 2001383.00
FLASHING MEMBRANE AT SILL AND
WRAP INTO ROUGH WINDOW INSTALLATION
OPENING. ISOMETRIC
Scale
NOT TO SCALE
INTERMITTENT 7a INSTALL NEW WINDOW
WINDOW SHIMS Designed Drawn Checked

COMPLETE PER SPECIFIED WALL B2M / AC AS / B2M AC


INSTALL SHEATHING MEMBRANE (a) INSTALL NEW WINDOW UNIT.
6 7 8 LAP SHEATHING MEMBRANE OVER METAL 9 ASSEMBLY AND APPLY ASSOCIATED
STARTER STRIPS AT JAMBS AND HEAD. (b) INSTALL HEAD FLASHING. DWG No. Version Date
FLASHING. SEALANT DETAILS. A5.201 3 2020-12-04
SHEATHING MEMBRANE (WRB/AB) LAPPED
OVER MEMBRANE STRIPPING. HT SAM
LAPPED ON HEAD FLASHING

PRE-FINISHED METAL J-TRIM C/W WEEPS @


24" O/C (MIN. 2 WEEPS)
2"
1

2"
1"

1 WINDOW HEAD - SECTION DETAIL


A5.202 SCALE: 6"=1'-0"

3
8" BACKER ROD AND CAULKING

INTERMITTENT SHIM TO PROVIDE 50%


LEVEL SUPPORT - PROVIDED BY WINDOW
MANUF.
2"

PRE-FINISHED METAL FLASHING WITH DRIP


EDGE AND END DAMS - USE HEMMED EDGE
@ LOWER FLOOR - FLASHING FASTENED
TO INTERMITTENT CLIP
IMPERMEABLE SAM (WRB/AB/ VB) FROM
SHEATHING OVER BLOCKING, INTO R.O.,
ONTO SUB-SILL AND SEALED TO WINDOW
FRAME - RUN MEMBRANE FLASHING 6" UP
JAMBS THEN LAP WINDOW JAMB
SHEATHING MEMBRANE OVER
REMOVE AND REPLACE EXISTING WOOD
2 WINDOW SILL - SECTION DETAIL TRIM WITH NEW - PRIMED AND PAINTED
A5.202 SCALE: 6"=1'-0" WHITE - SUB-SILL TO BE FULLY CONCEALED
BY TRIM
1
2
3

Scale
Stamp
Version

Designed

DWG No.
A5.202
6"=1'-0"

B2M / AC

3
Version
Drawn
Description
Issued for 100%

AS / B2M
Date
Issued for 50% Review
Issued for 90% Review

COYOTE CREEK

AC
Checked
ELEMENTARY SCHOOL

2020-12-04
WINDOW HEAD AND SILL
2021-3-05
2020-12-10
2022-02-03

YYYY-MM-DD

MH No. 2001383.00

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
REMOVE AND REPLACE EXISTING WOOD
TRIM WITH NEW - PRIMED AND FINISH
PAINTED ON EXPOSED SURFACES

SHEATHING MEMBRANE (WRB/AB) WRAPPED


INTO R.O. AND SEALED TO WINDOW FRAME

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
FINISH BEAD OF SEALANT

BACKER ROD AND CAULKING (AB)


2" 3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

3
8" BACKER ROD AND CAULKING

GUIDE RAIL FOR SHUTTER


COYOTE CREEK
ELEMENTARY SCHOOL
PRE-FINISHED METAL FLASHING WITH HEMMED
EDGE MH No. 2001383.00
1 WINDOW JAMB - PLAN PRE-FINISHED METAL J-TRIM
A5.203 SCALE: 6"=1'-0"
TYPICAL WINDOW JAMB

Scale
6"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.203 3 2020-12-04
GUIDE RAIL FOR SHUTTER
FINISH BEAD OF SEALANT
SHEATHING MEMBRANE (WRB/AB) WRAPPED
INTO R.O. AND SEALED TO WINDOW FRAME

3
8" BACKER ROD AND CAULKING
PRE-FINISHED METAL FLASHING WITH HEMMED
EDGE

PRE-FINISHED METAL J-TRIM

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

ADD ADDITIONAL CLIPS / VERTICAL RAILS AS


REQUIRED FOR SUPPORT

PRE-FINISHED METAL FLASHING

COYOTE CREEK
PRE-FINISHED METAL J-TRIMS BUTT AT ELEMENTARY SCHOOL
OUTSIDE CORNER

MH No. 2001383.00

WINDOW JAMB AT CORNER

Scale
1 WINDOW JAMB TRANSITION AT OUTSIDE CORNER - PLAN 6"=1'-0"
A5.204 SCALE: 6"=1'-0" Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.204 3 2020-12-04
SHEATHING MEMBRANE (WRB/AB) LAPPED
OVER MEMBRANE STRIPPING. HT SAM IS
LAPPED OVER HEAD FLASHING

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
2"
SHEATHING MEMBRANE STRIPPING (AB)
WRAPPED INTO R.O. AND SEALED TO DOOR 3 Issued for 100% 2022-02-03
FRAME
2 Issued for 90% Review 2021-3-05
2" FINISH BEAD OF SEALANT 1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
INSECT SCREEN
Stamp
PRE-FINISHED METAL J-TRIM C/W WEEPS @
24" O/C (MIN. 2 WEEPS)

HEAD FLASHING C/W END DAMS AND DRIP


EDGE - DOWN LEG BROUGHT OUT OVER
THE PLANE OF THE CLADDING TO
ACCOMMODATE JAMB FLASHING

1"
3
8" CAULKING JOINT

DOOR FRAME FILLED WITH CLOSED CELL


SPRAY APPLIED POLYURETHANE FOAM COYOTE CREEK
INSULATION (AB) ELEMENTARY SCHOOL

MH No. 2001383.00

REFURBISH EXISTING DOORS. REMOVE TO REPAINT


INTERIOR AND EXTERIOR, REPLACE WEATHER STRIPPING HOLLOW METAL DOOR
AND DOOR SWEEPS. EXISTING LOCKING AND FOB HEAD
SYSTEM TO BE REINSTALL ON THE DOORS. GENERAL
CONTRACTOR TO CONTACT THE SAME SUPPLIER TO Scale
COORDINATE THE WORK REQUIRED TO REINSTALL BACK 6"=1'-0"
1 HOLLOW METAL DOOR HEAD - SECTION DETAIL THE FOB SYSTEM ON THE DOOR. AUTOMATED DOOR Designed Drawn Checked
A5.208 SCALE: 6"=1'-0" OPENING TO BE REMOVE AND REINSTALLED. B2M / AC AS / B2M AC
DWG No. Version Date
A5.208 3 2020-12-04
X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
REPLACE DOOR SWEEPS
Version Description YYYY-MM-DD
Stamp

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

HOLLOW METAL DOOR


THRESHOLD
Scale
6"=1'-0"
1 HOLLOW METAL DOOR THRESHOLD - SECTION DETAIL Designed Drawn Checked
A5.209 SCALE: 6"=1'-0" B2M / AC AS / B2M AC
DWG No. Version Date
A5.209 3 2020-12-04
FINISH BEAD OF SEALANT

DOOR FRAME FILLED WITH CLOSED


CELL SPRAY APPLIED POLYURETHANE
FOAM INSULATION (AB)

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
3 Issued for 100% 2022-02-03
3"
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

3
8" BACKER ROD AND CAULKING

PRE-FINISHED METAL FLASHING WITH HEMMED


EDGE

PRE-FINISHED METAL J-TRIM


COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

HOLLOW METAL DOOR


JAMB
1 HOLLOW METAL DOOR JAMB - PLAN
A5.210 Scale
SCALE: 6"=1'-0"
6"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.210 3 2020-12-04
PRE-FINISHED METAL FLASHING WITH DRIP
EDGE AND END DAMS - USE HEMMED EDGE
@ LOWER FLOOR - FLASHING FASTENED

2"
TO INTERMITTENT CLIP

1 WINDOW HEAD - SECTION DETAIL


A5.212 SCALE: 6"=1'-0"

3
8" BACKER ROD AND CAULKING

INTERMITTENT SHIM TO PROVIDE 50%


LEVEL SUPPORT - PROVIDED BY WINDOW
MANUF.
2"

PRE-FINISHED METAL FLASHING WITH DRIP


EDGE AND END DAMS - USE HEMMED EDGE
@ LOWER FLOOR - FLASHING FASTENED
TO INTERMITTENT CLIP
IMPERMEABLE SAM (WRB/AB/ VB) FROM
SHEATHING OVER BLOCKING, INTO R.O.,
ONTO SUB-SILL AND SEALED TO WINDOW
FRAME - RUN MEMBRANE FLASHING 6" UP
JAMBS THEN LAP WINDOW JAMB
SHEATHING MEMBRANE OVER
REMOVE AND REPLACE EXISTING WOOD
2 WINDOW SILL - SECTION DETAIL TRIM WITH NEW - PRIMED AND PAINTED
A5.212 SCALE: 6"=1'-0" WHITE - SUB-SILL TO BE FULLY CONCEALED
BY TRIM
1
2
3

Scale
Stamp
Version

Designed

DWG No.
A5.212
6"=1'-0"

B2M / AC

W1a
Version
Drawn
Description
Issued for 100%

AS / B2M
Date
Issued for 50% Review
Issued for 90% Review

HEAD AND SILL


COYOTE CREEK

AC
Checked
ELEMENTARY SCHOOL

CLEARSTORY WINDOW

2020-12-04
2021-3-05
2020-12-10
2022-02-03

YYYY-MM-DD

MH No. 2001383.00

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
REMOVE AND REPLACE EXISTING WOOD
TRIM WITH NEW - PRIMED AND FINISH
PAINTED ON EXPOSED SURFACES

SHEATHING MEMBRANE (WRB/AB) WRAPPED


INTO R.O. AND SEALED TO WINDOW FRAME

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
FINISH BEAD OF SEALANT

BACKER ROD AND CAULKING (AB)


2"
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

3
8" BACKER ROD AND CAULKING

COYOTE CREEK
ELEMENTARY SCHOOL
PRE-FINISHED METAL FLASHING WITH HEMMED
EDGE
1 WINDOW JAMB - PLAN PRE-FINISHED METAL J-TRIM
MH No. 2001383.00
A5.213 SCALE: 6"=1'-0"
CLERESTORY WINDOW
JAMB
Scale
6"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.213 3 2020-12-04
CONCEAL CONDUIT IN
RAINSCREEN CAVITY
NEW CLOSURE FLASHING

NEW AVB TO LAP ONTO


EXISTING A MINIMUM 6 "

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
REMOVE AND REINSTALL
METAL PANEL AND
INSULATION
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

1 SLOPED ROOF TO ADJACENT WALL COYOTE CREEK


A5.401 SCALE: 3"=1'-0"
ELEMENTARY SCHOOL

MH No. 2001383.00

SLOPED ROOF TO
ADJACENT WALL GUTTER
DETAIL
Scale
1 1/2"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.401 3 2020-12-04
1
RIDGE CRICKET

1
CUT BACK 12"

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

CUT EXISTING
METAL ROOF 12"
FROM CURB

REMOVE AND
REINSTALL FOR
MEMBRANE TIE IN COYOTE CREEK
EXISTING METAL ELEMENTARY SCHOOL
ROOF

SHEATHING MH No. 2001383.00


SEE ASSEMBLY
SKYLIGHT DETAIL

Scale

1
SKYLIGHT ON
EXISTING METAL ROOF
1 1/2"=1'-0"
-
SCALE: 1-1/2"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.402 3 2020-12-04
1
RIDGE CRICKET

CUT BACK 12"


1

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
1

NEW SKYLIGHT 3 Issued for 100% 2022-02-03


2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
NEW BUILD CURB UP TO 8" Version Description YYYY-MM-DD
HEIGHT
Stamp

METAL ROOFING

NEW CRICKET
NEW WOOD BUILT-UP CURB
TYP. AROUND SKYLIGHTS

NEW INTERIOR FINISH

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

SKYLIGHT DETAIL
SKYLIGHT ON
1 EXISTING METAL ROOF
-
SCALE: 1-1/2"=1'-0" Scale
1 1/2"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.403 3 2020-12-04
1
RIDGE CRICKET

CUT BACK 12"


1

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
1
3 Issued for 100% 2022-02-03

NEW SKYLIGHT 2 Issued for 90% Review 2021-3-05


1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD

BUILD CURB UP TO 8" HEIGHT Stamp

METAL ROOFING

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

SKYLIGHT DETAIL

SKYLIGHT ON Scale
1 EXISTING METAL ROOF
-
SCALE: 1-1/2"=1'-0" 1 1/2"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.404 3 2020-12-04
SHEATHING MEMBRANE (WRB/AB)
LAPPED OVER SAM AND METAL
FLASHING
CONT. BEAD OF SEALANT (AB)

2"

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
INSECT SCREEN
3 Issued for 100% 2022-02-03

4"
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
PREFINISHED METAL FLASHING WITH

2"
Version Description YYYY-MM-DD
HEMMED EDGE TO FULLY CONCEAL
Stamp
SAM

COYOTE CREEK
ELEMENTARY SCHOOL

UPPER SLOPED ROOF TO WALL / CANOPY MH No. 2001383.00


1 TRANSITION - SECTION PARALLEL TO SLOPE
A5.405 SCALE: 3"=1'-0" METAL CLADDING TO
SLOPED METAL ROOF
Scale
1 1/2"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.405 3 2020-12-04
X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

SMALL METAL CANOPY


ROOF
Scale
3"=1'-0"
1 SECTION AT METAL CANOPY Designed Drawn Checked
-
SCALE: 3"=1'-0" B2M / AC AS / B2M AC
DWG No. Version Date
A5.406 3 2020-12-04
X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00
FLAT ROOF
1 SCUPPER DETAIL FLAT ROOF OVERFLOW
-
SCALE: 3"=1'-0"
SCUPPER
Scale
3"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.407 3 2020-12-04
GLASS CANOPY

BUTT METAL J-TRIM AT


CORNER

PRE-FINISHED METAL
FLASHING

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
METAL CLOSURE
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

2 INSIDE CORNER TOP NEW CLADDING DETAIL COYOTE CREEK


A5.408 SCALE: 3"=1'-0" ELEMENTARY SCHOOL

MH No. 2001383.00
1 CANOPY TO NEW CLADDING
A5.408 SCALE: 3"=1'-0"
MISCELLANEOUS DETAILS

Scale
3"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.408 3 2020-12-04
3
8"
BACKER ROD
AND CAULKING

METAL FLASHING
WALL TO BE LEFT
NON-EXTERIOR
INSULATED

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
1 METAL CLADDING CORNER 3 Issued for 100% 2022-02-03

A5.409 SCALE: 3"=1'-0" 2 Issued for 90% Review 2021-3-05

2 BRICK CLADDING TRANSITION 1 Issued for 50% Review 2020-12-10

A5.409 Version Description YYYY-MM-DD


SCALE: 3"=1'-0"
Stamp

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

UNINSULATED WALL
DETAILS
Scale
3"=1'-0"
3 METAL CLADDING CORNER Designed Drawn Checked
A5.409 SCALE: 3"=1'-0" B2M / AC AS / B2M AC
DWG No. Version Date
A5.409 3 2020-12-04
SEALANT

PRE-FINISHED METAL J-TRIM

EXISTING DOWNSPOUT
PRE-FINISHED METAL CLOSURE

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
3 Issued for 100% 2022-02-03
2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

1 DOWNSPOUT AT METAL CLADDING


A5.410 SCALE: 3"=1'-0"

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

DOWNSPOUT DETAIL

Scale
3"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.410 3 2020-12-04
HT SAM LAP ONTO FLASHING

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
INSTALL NEW LOUVER TO 3 Issued for 100% 2022-02-03

MATCH EXISTING 2 Issued for 90% Review 2021-3-05


1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp
PROVIDE BACK ANGLE WITH
SAM AROUND PERIMETER

COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

LOUVER DETAIL

1 LOUVER DETAIL Scale


A5.411 SCALE: 6"=1'-0" 6"=1'-0"
Designed Drawn Checked
B2M / AC AS / B2M AC
DWG No. Version Date
A5.411 3 2020-12-04
NEW
DIVERTER
FLASHING

X:\Proj\2020\200138300-BCH Frost Rd Coyote Creek Element\09. CAD\Coyote Creek Elementary School\coyote 5.100 LAST REV 2.dwg
REMOVE
PANELS
AS
REQUIRED
3 Issued for 100% 2022-02-03
FOR EPDM
INSTALLATION 2 Issued for 90% Review 2021-3-05
1 Issued for 50% Review 2020-12-10
Version Description YYYY-MM-DD
Stamp

NEW
CLADDING
ASSEMBLY

NEW
EPDM
MEMBRANE COYOTE CREEK
ELEMENTARY SCHOOL

MH No. 2001383.00

LOUVER DETAIL
1 EPDM GUTTER DETAIL - 3D Scale
A5.412 SCALE: 3"=1'-0" NTS
EXISTING Designed Drawn Checked
EPDM
B2M / AC AS / B2M AC
MEMBRANE
DWG No. Version Date
A5.412 3 2020-12-04