Professional Documents
Culture Documents
Electronic Sensors Mid II QP
Electronic Sensors Mid II QP
Blooms Course
S.NO. Questions Marks
Level Outcomes
1 Explain about Variable inductance transducer 5 Un CO2
OR
2
Discuss in-detail about Temperature fiber optic Un CO2
sensor 5
3
Explain about Reference Electrodes, Sensor Un CO2
Electrode 5
OR
4
Discuss about Amplification, Filters, Converters 5 Un CO3
of Primary sensor
Blooms Course
S.NO. Questions Marks
Level Outcomes
1 Discuss about sychro’s with neat diagram 5 Un CO2
OR
a) Explain about types of photo detectors? 2.5 Un CO2
2
b) What is radiation sensor? 2.5 Re CO2
Blooms Course
S.NO Questions Marks
Level Outcomes
1
Discuss about Angular and Rotary movement Un CO2
transducer 5
OR
2 Explain briefly about Standard Hydrogen Electrode 5 Un CO2
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
PART 1: CHOOSE THE CORRECT ANSWER.
BT
S.NO. QUESTION CO’S
LEVEL
Which of the following is not a type of radiation detectors? ( )
a) Geiger Muller counter
1 b) Proportional counter Re CO2
c) Semiconductor detector
d) Flame emission detector
Which of the following is not a characteristic feature of a salt bridge?( )
a) Salt bridge joins the two halves of an electrochemical cell
b) It completes the inner circuit
2 c) It is filled with a salt solution (or gel) Re CO2
d) It does not maintain electrical neutrality of the electrolytic solutions of the
half-cells
BT
S.NO. QUESTION LEVEL CO’S
A _________________ is a junction that connects the anodic and
1) cathodic compartments in a cell or electrolytic solution Re CO2
An ___________________can convert electrical energy to chemical
energy and can also convert electrical energy to chemical energy
2) Un CO2
Input data of smart sensor will be __________
3) Re CO3
Output of smart sensor will be __________
4) Un CO3
The equation for cell potential E cell=____________
5) Re CO2
Gas filled detectors are___________ ,__________________ and
_______________
6) Re CO2
SHE stands for___________
7) Re CO2
Ionizing radiations are of _______________, ______________ and
___________
8) Re CO2
Oxidation is the ____________________
9) Un CO2
The motion of Actuator produces can be either______________ or
______________
10) Re CO2
PRINCETON INSTITUTE OF ENGINEERING AND TECHNOLOGY FOR WOMEN
(Approved by AICTE & Affiliated to JNTUH)
Chowdharyguda, Korremula(V),Ghatkesar (M),Medchal-Malkajgiri(D),TS-500088
IV B.Tech I Semester (R18– Regulation) (2023 – 24)
II – Mid Term Examination, DEC – 2023
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
PART 1: CHOOSE THE CORRECT ANSWER.
BT
S.NO. QUESTION CO’S
LEVEL
Which of the following are considered to be the lowest form of
Electromagnetic radiation?
1 a) IR radiation b) Micro waves ( ) Re CO2
c) UV radiation d) Radio waves
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
PART 1: CHOOSE THE CORRECT ANSWER.
BT
S.NO. QUESTION CO’S
LEVEL
Which of the following is not a characteristic feature of a salt bridge?( )
a) Salt bridge joins the two halves of an electrochemical cell
b) It completes the inner circuit
1 c) It is filled with a salt solution (or gel) Re CO2
d) It does not maintain electrical neutrality of the electrolytic solutions of the
half-cells
BT
S.NO. QUESTION LEVEL CO’S
Ionizing radiations are of _______________, ______________ and
___________
1. Re CO2
Oxidation is the ____________________
2. Un CO2
The motion of Actuator produces can be either______________ or
______________
3. Re CO2
A _________________ is a junction that connects the anodic and cathodic
4. compartments in a cell or electrolytic solution Re CO2
An ___________________can convert electrical energy to chemical
energy and can also convert electrical energy to chemical energy
5. Un CO2
Input data of smart sensor will be __________
6. Re CO3
Output of smart sensor will be __________
7. Un CO3
The equation for cell potential E cell=____________
8. Re CO2
Gas filled detectors are___________ ,__________________ and
_______________
9. Re CO2
SHE stands for___________
10. Re CO2
PRINCETON INSTITUTE OF ENGINEERING AND TECHNOLOGY FOR WOMEN
(Approved by AICTE & Affiliated to JNTUH)
Chowdharyguda, Korremula(V),Ghatkesar (M),Medchal-Malkajgiri(D),TS-500088
IV B.Tech I Semester (R18– Regulation) (2023 – 24)
II – Mid Term Examination, DEC – 2023
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
PART 1: CHOOSE THE CORRECT ANSWER.
BT
S.NO. QUESTION CO’S
LEVEL
Which of the following is not a configuration of a smart sensor? ( )
a) processor b) transducer
1 Re CO3
c) network interface d) none of the above
Which of the following defines smartness of sensor ( )
c) Circuit components b) Quality of data
2 Un CO3
d) Circuit size d) all of the above
Which of the following is not a generally used electrolyte in the salt bridges
3 used to connect the two half-cells of an electrochemical cell? ( ) Un CO2
a) NaCl b) KNO3 c) KCl d) ZnSO4
BT
S.NO. QUESTION LEVEL CO’S
The motion of Actuator produces can be either______________ or
______________
1. Re CO2
A _________________ is a junction that connects the anodic and
2. cathodic compartments in a cell or electrolytic solution Re CO2
An ___________________can convert electrical energy to chemical
energy and can also convert electrical energy to chemical energy
3. Un CO2
Input data of smart sensor will be __________
4. Re CO3
Output of smart sensor will be __________
5. Un CO3
The equation for cell potential E cell=____________
6. Re CO2
Gas filled detectors are___________ ,__________________ and
_______________
7. Re CO2
SHE stands for___________
8. Re CO2
Ionizing radiations are of _______________, ______________ and
___________
9. Re CO2
Oxidation is the ____________________
10. Un CO2