A BANSAL CALIBRATION SERVICES
BCS
‘TEST REPORT
ULR No.: T0645523000006210F
Report No.—2509080006 Issue Date ~- 08-09-2023 |
Customer Name: Hal Offshore Limited. ‘Customer Ref. No. 1946
Bung 4th Floor,32 Corporate Avenue
Near Paper Box Industry Of.
‘Mahakali Caves Road Andheri East Mumbai 400093,
‘Sample Particulars: 5D BEND 90 DEG BW CS SMLS 250NB 9.3 mm PSL2 APISL X65,
Heat No./Batch No. 125667/A435, Sample Receipt Date
Test Requested _: Physical Test, Hardness Test, Sample Drawn By By CUSTOMER
Environmental Conditions ‘TEST RESULT
Temperature (°C) | Relative Humidity (%) Date of Testing = 08-09-2023
2385°C 30-70%
Mechanical Tes!
‘Test Method: - ASTM E8/E8M-21, ASTM £18:2020,
Parameter sult ]
“Tensile strength (N/mm?) 564
O.2H offset Yield strength (N/mm) 264
% Elongation(GL=50rm) 305
945 HREW
Tec By Conversion:- 208 HBW
Witness By:- DNV
Find of Report
Van INSPECTION
\. woos 59-155
09/4
NOTE:- 4. Semple wie cetsne for Tans Test only for thee months,
2 Sample wil be retained for Chemical Compestion only for one month
3. The resus ste refer only to the tested sample and applicable parsers
Endorsement of product nether inferred nor imped
4-Thisrepor cannot be ured a evidence in a court of ow without the writen approval ofthat
5 Censente sha not be reproduced expt i fl withou the writen aporova ofthe sero.
ait about the report should be nist within 7 dave
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA.
Mob. : 08920907896, 09313212192 Page 1 of 1
sting@bestestlab.com, sales@bestestiab.com, www.bostestiab.com
E-mail :
Format No. : BCS/QF/7.8-01BANSAL CALIBRATION SERVICES
BcSs
TEST REPORT
ULR No.: ¥¢645523000006209F
Report No.—2509080005 ab E Issue Date — 08-09-2028
Customer Name Hal Offshore Limited ‘Customer Ref. No. 7946
Bwingdth Floor 32 Corporate Avenue
Near Paper Box industry Off.
Mahakali Caves Road Andherl East Murnbai-400093,
Sample Particulars: 5D BEND 90 DEG CS SMS 8ONB 7.1 mm PSL2 APISLX65,
Heat No./Batch No. 216525/AM35. Sample Receipt Date _: 08-09-2023
Test Requested _: Physical Test, Hardness Test, Sample Drawn By + By CUSTOMER
Environmental Conditions TEST RESULT
[Temperature (°C) | Relative Humidity 0%) Date of Testing : 08-09-2028
23 30-70%
Mechanical Test:
st Method: - ASTM E8/EBM-21, ASTM E18:2020,
=e Parameter Result
Terai strength (N/imim") 576
‘OW offset Vield strength (N/mm) 454
% Elongation(GL=SOmm) 30.0
87.6 HRW
Heriot By Conversion:- 174 HOW.
Witness By:- DNV :
5 ind of Report
= erection |
INOTE:- 1. Sample wl be retained for Tene Tet onl forthrse months.
2 Sammie wil beretaned fr Chemical Compaction ony fr ene month
3 The resulted refer only othe tasted sample ad appeable par arsters
Endersement of product nether nfrrad nor imped
4. This report cannot be uzad a5 evidence na court oflow without the written approval ofthe
5. Certfcate shall not be reproduced excptin ful, without the writen approval ofthe abr story.
6 Any complaint about the report shouldbe ftoated within 7 dys.
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Mob. : 08920807896, 09313212192 Page 1of1
E-mail : testing@bestestlab.com, sales@bcstestlab.com, www.bestestlab.com
Format No. : BCS/QFI7.8-01BANSAL CALIBRATION SERVICES
BCS
TEST REPORT
ULR No.: T1¢645523000006208
Report No.—2509080004 5 Issue Date — 08-09-2023
Customer Name: Hal Offshore Limited. Customer Ref. No. +906)
wing 4th Floor,32 Corporate Avenue
Near Paper Box industry Off
‘Mahakali Caves Road Andheri East Mumbal -400093,
Sample Particulars: 5D BEND 90 DEG BW CS SMLS 300NB 7.1 mm PSL2 APISLX65,
Heat No./Batch Wo. 452469/A434. Sample Receipt Date: 08-09-2023
Test Requested _ : Physical Test, Hardness Test, Sample Drawn By : By CUSTOMER
Environmental Conditions] TEST RESULT
Temperature (°C) | Relative Humidity (8) Date of Testing: 03-09-2023
235°C 30-70%
Mechanical Test:
‘Test Method: - ASTM £8/E8M-21, ASTM E18:2020,
Parameter Result
Tensile strength (N/mm) 569
0.2% off set Vield strength (N/mm?) 452
% Elongation(GL=S0mm) 34.5
85.9 HRBW
Hardness Jes By Conversion:- 169 HBW
Witness By:- DNV
Find of Report
NOTE:- 1. Semple wil be retained for Tense Testenly for three months.
2 Sample wile retained for Chemical Compartin only for one mouth
23. The reuls listed refer only to the tested sample and apaicable parameters.
Endorsement of product snether erred nor nad
4. This report conot be usedas evidence na cour of ow without the wrten approval the lb
ete shall not be reproduced except nfl without the wnten approval ofthe laboratory,
8 Ay complaint about the report should Dentist within 7 day.
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA.
Mob. : 08920807896, 09313212192 Page 1 of 1
E-mail: testing@bestestlab.com, sales@bestestlab.com, www.bestestlab.com
Format No. : BCS/QF/7.8-01BANSAL CALIBRATION SERVICES
BCS
‘TEST REPORT
ULR No.: T645523000006114F
Report No.~2308080022 Issue Date — 08-052023 |
Customer Name _ : Hal Offshore Limited. Customer Ref. No. +986
Bing th loa 32 Corporate Avenue
Near Paper Bo indus Of.
Mahakal aves Road Andheri Cast Mumbsl 400003,
Sample Particulars: 5D BEND 90 DEG Cs SMLS 80NB 7.1 mm PSL2 APISL X65,
Heat No./Batch No. 216525/A435. Sample Receipt Date + 08-09-2023
Test Requested _: Charpy Impact Test. Sample Drawn By + By CUSTOMER:
vronmertal Conditions TEST RESULT
Temperature (c) | Relative Humidity) | Date of Testing 08-09-2028
7isc | 30.70%
Mechanical Test:-
‘Test Method: - ASTM E23: 2018
Parameter tesult
Charpy Impact Test (V-Notch At. ~48°C) 198 J, 118 J, 240).
Specimen Size: 5X 10X 55mm Avg.- 185.33 J.
Witness By: DNV
7 “***End of Report***
NNOTE:- _1.Somple wil be retained for Tense Test oly for thee months
2 Sample wil be retained fr Chemical Compeston ony for one month
3. The rests sted refer only tothe tested sample and applicable parameters
Endorsement of product nether inferred nar imped
4:Thisteport canna be used as evidence ina court of fw without the weRten appcoval ofthe la.
5. Certcate sal nat be reproduced except in full without the writen spprovat ofthe laboratory.
6-Any complaint about the report shouldbe intimated within 7 days,
49/39, Site IV, Indl, Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Mob. : 08920907896, 09313212192 Page 1 of 1
E-mail : testing@bcstestlab.com, sales@bestestlab.com, www.bcstestlab.com
Format No. : BCSIQF/7.8-01BANSAL CALIBRATION SERVICES
BCS
‘TEST REPORT
ULR No: Tc645523000006115F
Report No.—2309080023 Issue Date —- 08-09-2023 |
Customer Name: Hal Offshore Limited. Customer Ref. No. #946
wing 4th Floor,32 Corporate Avenue
Near Paper Box Industry Off.
Mahakali Caves Road Andheri East Mumbai -400093.
‘Sample Particulars: SD BEND 90 DEG BW CS SMLS 250NB 9.3 mm PSL2 APISL X65,
Heat No,/Batch No. 125867/A435. Sample Receipt Date: 08-09-2028
Test Requested _: Charpy impact Test. ‘Sample Drawn By : By CUSTOMER
Environmental Conditions TEST RESULT
Temperature(°C) | Relative Humidity (26) Date of Testing: 08-09-2023
2385°C 30-70%
Mechanical Tes
Test Method: - ASTM £23: 2018
Parameter Result
Charpy impact Test (V-Notch At 48°C) 1964, 202, 1561.
i Avg. 184.66.
"End of Report
NOTE:- 1. Sormple wil be retained for Tense Test only for tives month
2. Somipe wil be retained for Chemical Composition ony far ne month
‘3. The results sted refer ly tothe tested sample and applicable parameters,
Endorsement of product nether inferred nor implied,
4: This report cannot be used as evidence n a cour of lw without the writen approval ofthe a,
5. Cerificate sha nt be reproduced except full without the writen prove ofthe aberstory.
6 Any comptoine about the report should bentoated witha 7 days.
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Mob. : 08920907896, 09313212192 Page 1 of 1
E-mail: testing@bestestiab.com, sales@bcstestlab.com, www.bestestlab.com
Format No, : BCSIOFI7.8-01BANSAL CALIBRATION SERVICES
BCS
‘TEST REPORT
ULR No.: T0545523000006113F
[ Report No.—2305080021 Issue Date — 08-09-2023
Customer Name: Hal Offshore Limited. Customer Ref. No. 1946
wing 4th Floor, 32 Corporate Avenue
Near Peper Box industry Of.
Mahkali Caves Road Andheri East Mumbai 400093.
‘Sample Particulars: 5D BEND 90 DEG BW CS SMS 300NB 7.1 mm PSL2 APISLX65,
‘Heat No./Batch No. 452469/8434. Sample Receipt Date + 08-09-2023
Test Requested _ : charpy impact Test. Sample Drawn By :By CUSTOMER
Environmental Conditions TEST RESULT
Temperature("¢) | Relative Humidity (6) Date of Testing: 03-09-2023
2325°C 30-70%
‘Mechanical Tes
Test Method: - ASTM £23: 2018
Parameter Result
Charpy Impact Test (V-Notch At-48°C) 1641, 178, 1401.
‘Specimen Size:- 5 X 10x 55mm. ‘Avg.- 160.66 J.
Witness By: DNV
***End of Report
INSPECTION
1. Sample wil be retained for Tene Test onl for three months
2. Sample wl be retained for Chemical Conpostion only for one month
3. The resus sted refer only othe tested sample and apptcable parameters
Endorsement of product is nether inferred nor lnpsied
4. This report cannot be ured as evidence in cour of aw without the writen approval ofthe lb,
5. Certificate shal not be reproduced except nfl without the writen epproval ofthe aborst
6-Any complaint about the report should bentimated withln7 days.
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Mob. : 08920907896, 09313212192 Page Loft
E-mail : testing@bestestlab.com, sales@bcstestiab.com, www. bestestiab.com
Format No. : BCS/QF/7.8-01BANSAL CALIBRATION SERVICES
BCS
TEST REPORT
UiR No. 7e645523000006112F a
[Report Wo.—2308090070 Emp Soveraes)|
Customer Name: Hal Offshore Limited. Customer Ref. No, 2 946
Bwing 4th Floor,32 Corporate Avenue
Near Paper Box Industry Off.
‘Mahakali Caves Road Andheri East Mumbai -400093,
‘Sample Particulars: 50 BEND 90 DEG BW CS SMLS 250NB 9.3 mm PSL2 APISLX65,
Heat No./Batch No. 125667/0435. Sample Receipt Date: 08.09.2023
Test Requested : chemical Composition. ‘Sample Drawn By : By CUSTOMER
Environmental Conditions TEST RESULT
Temperature(°C) | Relative Humidity (36) Date of Testing : 08-09-2023
2385°C 30-70% Test Method: ASTM-£-415-21
‘CHEMICAL COMPOSITION: (Carbon & Alloy Steel)
Element
c
Si
Mn
Pe
5
cr
"Find of Report
NOTE:- _1.Same wit be retained for Tensile Test oly for thes months
2- Sample wil be retained for CherricalCompaston only for one month,
refer only tothe tested Sormple and appcable porsmatrs
of producti nether inferred or inpled
cannot be usedas evidence ina cour of aw without the writen approval ofthe lab
5. Cerfcate shall not be reproduced excep i fl without the writen appeal ofthe iaborsey.
6 Any complaint sbout the report shouldbe intimated within 7 days
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Mob, : 08920907896, 09313212192 Page 1 of 1
E-mail : testing@bestestlab.com, sales@bcstestlab.com, www.bestestlab.com
Format No. : BCSIQFI7.8.01BANSAL CALIBRATION SERVICES
Eee ESE)
BCS
TEST REPORT
ULR No.: 1€645523000006111F
Report Ne.—7309080019 issue Date — 08-082003 ]
Customer Name lal Offshore Limited. Customer Ref. No. 2946
wing 4th Floor,32 Corporate Avenue
Near Paper Box Industry Off.
‘Mahakali Caves Road Andheri East Mumbai -400093.
Sample Particulars: 5p BEND 90 DEG Cs SMS 80NB 7.1 mm PSL2 APISL X65,
Heat No./Batch No. 216525/A435. Sample Receipt Date ++ 08-09-2023
Test Requested —: Chemical Composition. Sample Drawn By 3 By CUSTOMER
Environmental Conditions TEST RESULT
‘Temperature (°C) Relative Humidity (2%) Date of Testing —: 08-09-2023
2345°C 30-70% Test Method :ASTM-£415-21
CHEMICAL COMPOSITION:- (Carbon &. Alloy Steel)
[7 Hement Results %
a c 032
ea 0.240
Mn 124
P 0.0203
TES ons 0.0036
cr 0.50
Mo. ‘O.00202
i 0430 7
al Doa7L
cu 0.0902 |
Nb 00152
Tr D015
v 0.0812
= 8 0.00020
ia N 0.0032
ind ot Report
NOTE:- 1. Sampe wil be retained for Tens Test only forthe mont
2. Sample wil be etaned for Chenical Composition only for one month,
3. The revs sted refer onl tothe tested sample and applicable parameters
Endorsement of product nether inferred noe impo,
4:Thi report cannot be used a5 eudence na cout of law without the wien approval f the sb
hal ot be reproduced exceptin fll without the witen approval ofthe lborstory
int about the report shouldbe lnteated within 7 ays,
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P, INDIA
Mob. : 08820907898, 09313212192
Page Loft
testing@bestestiab.com, sales@bestestiab.com, www.bestestlab.com
E-mei
Format No. : BCS/QF/7.8-01BANSAL CALIBRATION SERVICES
BCS
TEST REPORT
ULR No.: 10645523000006110F
[Report No.— 2308080018 fue Date 8002003
Customer Name: Hal Offshore Limited. ‘Customer Ref. No. 946
Bwing 4th Floor,32 Corporate Avenue
‘Near Paper Box Industry Off.
‘Mahakali Caves Road Andheri East Mumbai -400093,
Sample Particulars: SD BEND 90 DEG BW CS SMLS 300NB 7.1 mm PSL2 APISL 6S,
Heat No./Batch No. 452469/A434, Sample Receipt Date + 08-09-2023
Test Requested __: chemical Composition. Sample Drawn By By CUSTOMER
Environmental Conditions TEST RESULT
Temperature (°C) | Relative Humidity (%) ie Date of Testing
acre 30-70% Test Method
CHEMICAL COMPOSITION: (Carbon & Alloy Stee!)
Element
c
st
Ma
[== a eee
5
or
Mo
Al
cu
End of Repo
INOTE:- 1. Spe wil be retained for Tense Test ony for thee menths
2-Somple willbe relsined for Chemical Compostion only for one month,
‘3. The results tite refer only to the tested sample and applicable parameters.
Endorsement of product nether Inferred nor implied,
4: This report cannot be used as evidence na cout of tan without the wrtten pgroval ofthe lab,
5. Crtfiate shal nt be reproduced except in ful without the ween approval of tee
6. Any complaine abut the report shouldbe intimated within 7 Gays,
49/39, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Mob. : 08920907896, 09313212192 Page 1of1
E-mail : testing@bestestlab.com, sales@bestestlab.com, www.bestestlab.com
Format No, : BCSIQF/7.8-01BANSAL CALIBRATION SERVICES
Calibration Certificate
BCS
Reaiiaacaman Sacer
a Sane ane =
ei Haanei.cuaunmcemees [RES | Taman
anne
Ghaviabad-201010 (U.P), Inca ae Sees ate ad
_| Cartiicate issue Date 2240-2002
A) Identification ON UUC (Unit Under Calibration)
Gite ciined [= WRG Teagan aa
7 a ae =
ae oe a a
= ae na =
2 er pn Oa
fis [ | Sie ay Tames Sea | ae
| iets "oct | aaa | ee | Senet [wat
SeGuncs | omsrns_| — tment | ys, | Set na
ce
peel ee Humidity 4 1060%RH Calibration Procedure BCSIMICP.O1
cates
=| te ane | WR | cl Epa ——Tee
| 000. 6.00 000 O00
; 7 ff 8 7
: as 7 7 oa
7 = a a 7m
: aa = = =
é | 200.00 000 0.02 005.
j 7 a iz i
eiivtieen | oe [ag Se aa a eA
= Sakata teeemereneaca eS oe
2. Tis mor shekt robe reproduced except in fel wtbout out lr pemison reg. DNV | L
soiecoeiaeeniel
‘sect atone ~~
ae Rae a
Reviewed / Approved By
VS. BANSAL
AUTHORIZED SIGNATORY
49/99, Site IV, Indl, Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Tele. : 00-91-120-4556377 & 79 Mob, : 08920907896
E-mail: testing@bestestlab.com, sales@bcstestiab.com, wawzbestestiad,comBANSAL CALIBRATION SERVICES
Calibration Certificate
BCS
mi N= BOSORT TG Rev No Rev Dats OUTED TR hs SORE
cent BOSNENHO OTE Tata TOF
Caro SRF No we SNE
‘Acces eee Calibration Date 08-06-2023
ee. | siaiapaminaias ad
Cortese at casa
Aligentification ON UUC (Unit Under Calibration)
Calivalon Ceres of | ROCKWELL HARONESSTESTER | wamoment ScNORE owraacsEDs
Hakatode, Bats RASS) Toa ms
Range ae Viuaispeaion ox
Toa ount Rixtanet CalbraonPeromidat ae
Bj Mas Eat ve for Calls
Tne ake Serio, |GabronAgiey | Tacatiy Goo No | Conieaw ba [VaapiS
Tiss Tes oa BN) 156 fa FRUSRDISo | —catatoot | “ORS
Hace Tet BbGREN) [206 Fa Frusunoreas | —cuoanoet —| oedema
Hess Tesi BbaREW | iit | Fal | prvcantaer | ~tenaat Tee
Haroness Test Block|HRC) | 4642 FRI FRIOS2UHO1945, 08/05/2021 0805/2024
Hares Test ck) | TRG Fa ruanses | ees | ~oanaaa
crest Tel oaRC) | 67 Fa roscunorees | ons | aetna
| etpwete [areas refer dad Tee 8
Rinne non ae TE Caltraon Poser scshicea2
Mechanical Calibration
Calibration Results
Standard Value | Observed Value Mean Error Repeatability
sorrow | a | we | 5 | wo [mi] me 03 aE
2S HREM sa _|_oa1_| e7_| a1] ora | ena 03 08
1H wz [ee | a7 | 5] om | mma 02 4
neue | es | me | m2 | mi | zo] m2 26 0
[ware [0 [as | ao [ws] aa] as “ar i
634 HRC 628 62.4 634 | 635. | 626 629 as Ma
Maen MOMEtI TE PONs | [Nacat aeaatsh ontepeiaatio omen eee
End Cercle
Note 1 Te atatoreuts mpatein fis cote lb ne lane a con essere
2.Ths pet sho na be reproduced except f witt ou Fr pemEsinin ig
Carton ceicale wiht sna ce otal
4. Aur estiales are Metobgical Traceable
5. Tis Cota ales tien Calta,
Calibrated Bj
ss. etiam
49139, Site IV, Indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Tele, : 00-91-120-4556377 & 79 Mob. : 08920807896 “
sting@bestestlab.com, sales@bestestlab.com, www.bestesttab.com
E-maiBANSAL CALIBRATION SERVICES
Calibration Certificate
BCS
Format No. BCS/QF7.6-01 ~ET, Rev. No.-01, Rev, Date 03.11.2022, ULR No.- CC243823000000162F
cet: ecSWanaro an Neale oF!
‘Customer Name: SRF. No. & Date BOSINZ3020008/28-02-2023
bts wis sansa caueanonservees | exibaton due time
‘a Sen Bed, Dl Tie
Certificate Issue date 03-03-2023,
A) Identification ON UUC (Unit Under Calibration)
CtiraonCorteneot | Olga Tempers exo PN) — | werent Wa
sa Sal 81205 et ie
ange “moa
tanto ore cae ed
6) Masta Eguipmen efor Clbraon
Nunefnate | Range! Sei Ceaccen ] Eee | Cm | vac pte
i Pear 7 Trearsa | ance | ami | oa
Tope 030" Combai Poste | SoSeTCPa?
Enwcane Cowden | satay sow7sKret eterence Stand eae
Bc Teal Slaton
ce Cotten Raus
See | Serva sarn"e [Obra ave wey c_—[ Ero °C | Uren easements
1 2000 83, 7 os
2 #900 86 a 024
a 000 2 28 m3
‘ “00 a5 05 5
5 100 6 22 028
¢ a0 41 <1 Oat
r 2500 a a1 O28
Hi oa 25 a8 2
9 ‘000 187 43 ow
10 195.00 1938 A2 026
TEs aa a rn cam ay TER EN OTD
Seance
Sena
fo: Tact name ctaanlsthe eln aeasinel ester
2 Tiseprtshaudne be repticd cept nit pe pion wig.
‘3. Carafe aia widow arabe ve no a
wares
een ee
Calbrated By h ‘Approved By
Sabato — Ty hd srocets
crsescus | fro nee |
49/39, Sie I, indl. Area Sahibabad, Ghaziabad-201010, U.P. INDIA
Tele, : 00-01-120-4556377 & 79 Nob. : 08820907896
E-mail; testing @bostestiab.com, sales@bestestad.com, wiiN DHAVIK INDIA PVT. LTD.
C-23, Ishaan Tower, 2™ Floor Sector-13, Vasundhara, Ghaziabad-201012 (U.P)
0120-4154111
4
Mob.: 9989788038, 9818391131 Pt wy
E-mail: dhavikindla@gmail.com x
CALIBRATION CERTIFICATE — ccs
Date of Receip! 06.05.2023
ULRNo.: ¢c340823000000040F Cert. Issue Date: 08.05.2023
Format No. 7.8E-01 Date of Calibration : 06.05.2023
Certificate No. : DIPL/23/040 Next Date for Calibration : 05.05.2024
Pape ots (As agreed with the Customer)
‘CUSTOMER ADDRESS [EQUIPMENT DESCRIPTION & IDENTIFICATION
M/s BANSAL CALIBRATION SERVICES ‘Nomenclature: | Impact Testing Machit
449/39, SITE-V, INDUSTRIAL AREA, Make META TEST
SAHIBABAD, GHAZIABAD, (UP}-201010 SNo, 2017/83
Y/DNo.: Bes /H/76
Model: AAIT-300 ASTM.
‘CALIBRATION REQUEST DETAILS Capacity: | 300]
Service RequestNo: | DIPL/2023/027 Location: | Mechanical Testing Lab
Dated: 06.05.2023 Field: Mechanical
Conditionofthe tem: | Good Group: Impact
MASTER EQUIPMENT USED
£8] inst. Name Sr.No. Cort. No, Cal. By Cal Due Date
Toad celtwith | 20061460 ‘DRS Engg, & Calibration
a | edcelw dovszose | CC319321000000591F eh a 08.11.2023
02 | Bevel Protractor | 177939 | __cc282122000001905 “TMPL Ghaziabad 37.41.2023
03 | Stop Watch | DipL/Sw-07 | cczz1322000003991F NCL Private Limited 29.11.2023
OF | DialGauge | wywB06 | _ cc2eat22000001916F ‘TPL Ghaziabad 37.11.2023
05 | Radius Gauge | DIPL/RG-01 | ¢c282122000001910F "TMPL Ghaziabad 37.1,2023
06 [Radius Gauge | DIPL/RG-02 | cczaziz2000001911F "TMPL Ghaziabad 371.2023
07 | Digital Vernier | 21111146 | ¢C282122000001909F "TMPL Ghaziabad 37.14.2023
08 | ‘Measuring Tape | DipL/Mt-o1 | _cc282122000001912F "TMPL Ghaziabad 374.2023
09 | Feeler Gauge [0502218999 | c282122000001913F "TPL Ghaziabad 174.2008
10 [__Glinometer “| pipt/ci-o1 | ¢c247222000002866F | _ 5. V. Engineering Centre 28.41.2023
ENVIRONMENTAL CONDITIONS (ATSITE) | PROCEDURE FOLLOWED | _ REFERENCE STANDARD
Temperature + tectoasec | 276°C DIPL/cP/o2 monavie
Humidity + S0#10%RH | 449%RH | Medium of Verification : Direct Verification
General condition of the machine
General condition of instruments used
‘Tightening of foundation Bolts
i. External vibration free
a
3
4,
Calibrated By:
Fame nfl
Designation : Asst < Designation ; Quality Manager
Giro Nae oe ee aCe LOC Viaer eee
Sale, Service and Calibration of Material Testing MachinesBAGSON CALISAATION LAB. PVT, UD,
8-14, DSIDC Complex, Patpar Ganj Industrial Area,
Delhi-110082 + Email lab@bagson.com
Ph, : 011-22147876, 22157878, 22167878, 9899897878
CALIBRATION CERTIFICATE OF
Universal Testing Machine
ULR= CCISSS7300000STIEF
Certificate No. : BCL/UIM26%246 Calibration dane
‘on: 06/05/2025 Page 1 of?
Issue date: 06/05/2023
‘Next suggested due date: 06/05/2024
Date of receipt of tem : 06/05/2023
‘Condition ofthe item
: Ok
[ Called eM. ~"“Bansal Calibration Services
49/39, Site LV, Industrial Area
Sahibabad,
‘Ghaziabad,U.P
Pincode:201010
OF, Mlentification om UU (Unit Under Call
ation)
[ Size “Range 0-200 KN Ref. Standard Procedure | 1S:1828(Part-1):2022/0P-
MSI
st Count 002 EN ‘BCL Wentification mark | BCLA64246
‘Manafactured by Banbros Calibration performed at_| SITE
Manufacturer Sr. No. | AD-11831 ‘Model /Type WDW.3004
Party 1D mark BCSEIOI Location Mech, Testing Lab
Environmental conditions(s): Temperature: 25 +/- 10 Degree C.
02 Standard & major equipment(s):
Relative Humidity :3010 70%
Standsvd(s) & | Range /Serial No. | Calibrating Agensy | Traveabiliiy Cert. | Cartificate | Valid Up to
Equipinents No. Date
‘Load Cell SOKNTAOS024 | DVGNABL Lab | CC35252300000088 | 15/04/3003 | 13/4Ta0I
Digital 3F
Force Proving | 300 kN/ - NPL new Delhi *23021523/D1.08/C- | 02/03/2023 | 02/05/2025
Instrument | AWON200KN. 495
Dynamometer_| 46709
1 DARDS USED ARE TRACEABLE TO NATIONAL STANDARDS THROUGH UNBROKEN
03. Calibration Results:
Calibrated ia Compression Mode
Certified Range? SkN- TKN
‘Scale Range 0 £0 100 %
Fore | Si] Std ‘Observed aTangTe Mean | Relive Tadfention error —[Relaive [Relate
Ny | readiog | reading an intl OO) repeatability fresluon
tron at - 7 error |in{al (4)
catipraton | obseevea | ore ee
centicate | temp,
_| exe | esare |
3 | soos | so03 494 | 4994 [022/014 |01s| 018 | 008 | 0090
10] to009 [10009 996-9533, 09 [O13
INSPECT T
1. The Calibration resuls in this certicate are valid at the
lime of and under the sated conditions of messuremeris.
2 This report should note reproduced except nfl witout
0x prior permission in wing,
‘9, This catia reetes only 10 the lem Calbrate,
‘Authorized By :
QeeeCALIBRATION CERTIFICATE OF
BAGSON CALIBRATION LAB. PVT. LID.
B14, DSIDC Complex, Patpar Ganj Industial Area,
Delhi-110082 + Email : lab@bagson.com
Ph, :011-22147878, 22157878, 22167878, 0200907878
Universal Testing Machine
Cerifiats Na. + BCLIUIMIGENS | Calibaton dane an > OGUSTOEE Tapia
Tesnedate OSES Tent sugested due das 06052004
Date of receipt of item ; 06/05/2023. Condition of the item 7 Ok
Calbate a Compresan Wade ered Wangs A0IN- BOOT
Seale Range 010 100%
Force ‘Sd. TCS. Observed at angle Relative indication error ‘Relative | Relative
Sr | cote | noe ne bape [rete
atin | atchea |] FF TT AT ST ST] sien Pe
2102 | 2103 | 2087 | 206 | 2089 | 2001 [076/032] 066| 058 | 044 | 0.005
sasa_| 5256 | 5227 | 523.7 | 526i | 5234 |055|042|029| 042 | 027 | 0002
~sii2 | eats | e394 | e386 | e376 | 85 [025[035|047| 036) 022 | 0001
1os2.1_[ 1052.5 [10521 [ 10s01 | 10497 | 1049.7 [023027] 031 | 027 | 009 | 0.001
Classification of Machine Class-4
Uncertainty of measurement: 4/- 0.9%
‘The reported uncertainty is at eaverage factor k-Z which comesponds to a coverage probability of approximately
95% for a nouinal distribution,
#**End of Report
4 The Calibration resuts in this cerafcate are vale atthe : :
line of ana under the stated condibons of meaeuremenis. Caltbratad By: Authorized By :
2, This report should notbe reproduce exceptin full wtheut
arte pemsson nw, W®