ES Model W-M115-3

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

W-M115-EN-202212

Series W-M115
Ductile Iron Pressure Reducing Valve
Size : Thread DN32-DN50 Flange DN50-DN300
The Watts W-M115 Pressure Reducing Valve is designed to
adjust, set and maintain downstream pressure of the pipeline. It’s
generally used in city water supply, industrial and agricultural
water transmission pipeline, etc.

Features
• Stable performance, safe and reliable
• Simple operation, convenient adjusting Specification
• Precise pressure reducing
• Long service life • Design Standard:AWWA C530
• Working Medium: water • Connection Type: Thread & Flanged is available
W-M115-BSPT CL 300 BSPT to BS21
Pressure - Temperature W-M115-Flange to PN16 to BS EN 1092-2 &
CL150 to ANSI B16.42 & CL300 to ANSI B16.42
• Nominal Pressure: PN16/CL150/CL300 • Test Standard: ISO/DIS 5208:2007
• Temperature Range: 0°C ~ 80°C • Pressure Reducing Range:
• Float Valve Working Pressure: 116Psi (8Bar) Standard: LF26A--10Psi~125Psi
• Minimum Different Pressure: 5Psi(0.035MPa) (0.07MPa~0.9MPa)(Pilot valve)
Optional : LF263AP--20Psi~175Psi(0.137Mpa~1.2Mpa)
Test Pressures LFCP15--30Psi~300Psi(0.206Mpa~2.06Mpa)
• Pressure Gauge: 0-350Psi
Class Pneumatic Hydraulic • Standard Pressure Setting: 50Psi (0.35MPa)
Shell: 24 bar
PN16 Seat: 7 bar
Seat: 17.6 bar Approval
CL150 Seat: 7 bar Shell: 25.2 bar
CL300 Seat: 7 bar Shell: 40 bar

Material
NO. Component Material Mustang Series Main Valve
1 Cover Ductile Iron+Epoxy Coated
1
2 Cover Bearing Stainless Steel 12
2
3 Shaft/Stem Stainless Steel 13
3
4 Stud Zinc Plated Steel/Stainless Steel 4 14
5 Cover Nut Zinc Plated Steel/Stainless Steel 5 15
6 Washer Zinc Plated Steel/Stainless Steel 6 16
7 Diaphragm Buna N(Nitrile)+Nylon 7 17
8 Spring Stainless Steel 8 18
9 Disc Retainer Ductile Iron+Epoxy Coated 9
19
10 Seat Disc Buna-N(Nitrile) 10
20
11 Body Ductile Iron+Epoxy Coated
12 Plug Brass/Zinc Plated Steel 11

13 Stem Nut Stainless Steel


14 LockWasher Stainless Steel
15 Spring Washer Stainless Steel EU Series Main Valve
16 Diaphragm Washer Ductile Iron+Epoxy Coated 1 12
17 Spacer Washer Fiber Fiber 2 13
18 Disc Guide Stainless Steel 3 14
19 Seat O-Ring Buna N(Nitrile) 4 15
20 Seat Ring Stainless Steel 16
5 17
6 18
7 19
8
20
9
10

11

Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without
incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Page 1 / 2
W-M115-EN-202212

Installation Dimensions
Connection Dimension: PN16 to BS EN 1092-2

Size DN Dimensions(mm) Flange Dimensions(mm) Weight


(mm) L H H1 B C n-ØD E T (Kg)
32 BSPT 184 305 271 235 / / / / 17.5
40 BSPT 184 305 271 235 / / / / 17.5
50 BSPT 238 315 268 250 / / / / 18.2
50 230 325 245 260 125 4-Ø19 165 19 18.6
65 290 343 250 265 145 4-Ø19 185 19 19.2
80 310 345 245 275 160 8-Ø19 200 19 20.1
100 350 395 285 345 180 8-Ø19 220 19 36.5
125 400 413 288 380 210 8-Ø19 250 19 58.6
150 480 430 288 405 240 8-Ø23 285 19 72
200 600 540 370 475 295 12-Ø23 340 20 140
250 660 650 450 560 355 12-Ø28 406 30.5 265
300 762 755 520 670 410 12-Ø28 482 31.8 465
*Please contact the local salesmen if the size ≥DN300 is needed.

Flow Rates
Size (DN) 32 40 50 65 80 100 150 200 250 300
Maximum Continuous (GPM) 95 130 210 300 485 800 1850 3100 5000 7000
Maximum Intermittent (GPM) 119 161 265 390 590 1000 2300 4000 6250 8725
Minimum Continuous (GPM) 1 1 1 20 30 50 115 200 300 400
CV Factor GPM (Globe) 25 30 45 75 100 175 490 770 1200 1750

Characteristic Curves
Full Port Series Reduce Port Series

3
.5/
/4

2 /2

/2

2/ 2
1-1
1-1

2-1

10
12
16
10
12

4
6

8
3

6
8

100 100
80 80
60 60

40 40
30 30
Pressure Drop(p.s.i.)

Pressure Drop(p.s.i.)

20 20

10 10
8 8
6 6

4 4
3 3

2 2

2 4 6 8 10 20 40 60 80 100 200 500 1000 2000 5000 10000 20000 2 4 6 8 10 20 40 60 80100 200 500 1000 2000 500010000 20000
100,000 100,000
Flow Rate-Gallons per minute(Water) Flow Rate-Gallons per minute(Water)

Cavitation Chart 400.00

After selecting the valve size, locate inlet and outlet pressure 380.00
360.00
on this chart. If the intersection point falls in the shaded area, 340.00
cavitation can occur. Operation of valves continually in the 320.00
Inlet Pressure . PSIG

cavitation zone should be avoided. Consult Watts ACV for 300.00


alternatives. 280.00
260.00
240.00 Noise
220.00
200.00 Damage
180.00
160.00
140.00
120.00
100.00
80.00
60.00
40.00
20.00
0.00
0 20 40 60 80 100 120 140 160
Outlet Pressure . PSIG

Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without
incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Page 2 / 2

You might also like