Bulletin

TECHNICAL Effective
: BAA: D0040
: July,01, 2007
SPECIFICATION Superseds : Nil
Dated : Nil
BRY-AIR (MALAYSIA) SDN. BHD.
307, 3rd Flr., Block C, Damansar Intan, Selangor, Malaysia.
PHONE : 60-3-77259919 FAX: 60-3-77259957
E-MAIL: bam@bryair.com.my Website: www.bryair.com.my

INDUSTRIAL DEHUMIDIFIER
FLi - SERIES
FLi WITH HIGH PERFORMANCE, METAL SILICATE FLUTED
DESICCANT SYNTHESISED ROTOR

FEATURE HIGHLIGHTS
High efficiency and reliability Easy to operate
* A totally self contained unit. * Suitable for continuous operation
* Robust stainless steel frame with double skin construction, * Auto / manual selector switch.
internal GI sheet. * Volume control dampers for both (P&R) air flow
* CNC fabricated with industrial grade coating. Easy to install
* High moisture removal. * Versatile, easy to package and handle
* EU-3 grade leak tight filters for Air intakes. * Small footprints; low volume/weight per CMH
* Multiple choice of reactivation heat source:- Easy to maintenance
electrical, steam, thermic fluid, direct/indirect fired gas * Rotor is water washable
* In-bolt process by-pass for custom designing of process * Quick serviceability and maintenance free-operation
air flow or process tempreture control Options
* Easy addition of pre/after cooler, higher grade filter * Humidity control by humidistat on/off
* Rotor incorporates robust internal structure with * Stainless steel construction
perimeter flange for industrial quality and durability. * Byr-Smart Controller
* Rotor perimeter flange extend media and seal life
* Rotor is non-flammable with organic < 2%.
* Edge hard face coating on rotor edge ensures long life and
good sealing for media and seals.
* Process and reactivation air flow sectors are insulated
* Unique PTFE bonded bulb seal design;minimized air leakage
INDUSTRIAL DEHUMIDIFIER - FLi … SPECIFICATION
PROCESS PROCESS PROCESS REACT REACT REACT REACT POWER * APPROX.
MODEL AIR FLOW ESP MOTOR AIR FLOW ESP MOTOR HEATER REQD. WEIGHT
CMH (Pa.) KW CMH (Pa.) KW KW (Kg)
FLi 2500 2500 300 1.5 833 250 0.746 26 415 /3/ 50 300

FLi 3000 3000 300 1.5 1000 250 0.746 32 415 / 3 / 50 350

FLi 4200 4200 300 2.2 1400 250 1.1 44 415 / 3 / 50 425

FLi 5000 5000 300 3.7 1667 250 1.1 53 415 / 3 / 50 495

FLi 6200 6200 300 2.2 2067 250 1.5 66 415 / 3 / 50 570

FLi 7300 7300 300 3.7 2433 250 1.5 77 415 / 3 / 50 650

FLi 8000 8000 300 3.7 2667 250 1.5 85 415 / 3 / 50 720

FLi 9000 9000 300 3.7 3000 250 2.2 95 415 / 3 / 50 780

FLi 10500 10500 300 3.7 3500 250 2.2 111 415 / 3 / 50 850

* Note:- Other voltage available are 200/220/240/415/440/460 VAC, 3Ph, 50/60 Hz

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE


Documents No. :BAA: D0040
Date : July,01, 2007 Page 1 of 4
DIMENSIONAL DATA & DUCT CONNECTION

4
R
25 40

Q
M

B
O
I

J G N
90
40
E
850

P
S

RE ACT

3
AI R N
I

HE ATER PROC ESS


A IR OU T

REAC T
AI R OUT

BE D DRI VE

PR OCESS

OVE RLOAD THER MOSTAT BED DRIV E


TRI PPED TRI PPED FAI LUR E

2
C

L
K

F
H

A
D

PROCESS DUCT REACTIVATION DUCT


UNIT DIMENSION DATA CONNECTION (mm) CONNECTION (mm)
MODEL
INLET (1) OUTLET (2) INLET (3) OUTLET (4)
A B C D E F G H I J K L M N O P Q R S

FLi 2500 1050 1130 1770 1594 2314 876 249 210 103 150 1324 939 925 244 340 476 515 150 160

FLi 3000 1050 1130 1770 1594 2314 876 249 210 103 150 1324 939 925 244 340 476 515 150 160

FLi 4200 1050 1130 1770 1618 2414 936 249 210 103 150 1266 939 925 270 375 476 515 200 340

FLi 5000 1050 1130 1770 1618 2414 936 249 210 103 150 1266 939 925 270 375 476 515 200 340

FLi 6200 1050 1310 1950 1740 2483 1191 249 251 138 150 1448 1038 1030 390 552 476 617 200 340

FLi 7300 1050 1310 1950 1740 2505 1191 249 251 138 150 1448 1038 1030 390 552 476 617 200 340

FLi 8000 1050 1510 2150 1788 2662 1291 258 169 138 150 1481 1248 1235 438 614 631 619 268 375

FLi 9000 1050 1510 2150 1788 2662 1291 258 169 138 150 1481 1248 1235 438 614 631 619 268 375

FLi 10500 1050 1510 2150 1788 2662 1291 258 169 138 150 1481 1248 1235 438 614 631 619 268 375

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE


Documents No. :BAA: D0040
Date : July,01, 2007 Page 2 of 4
PERFORMANCE CHART FLi -SERIES

Performance charts are for nominal process airflow within the operating range each FLi Series
and assumes XPI = XRI. Please consult bry-air for other specific condition.

NOMINAL PROCESS AIR FLOW

PROCESS OUTLET AIR DB TEMPRATURE TPO(OC)


PROCESS OUTLET AIR MOISTURE CONTENT wPO(g/kg

16 60
35°C
30°C
14 25°C 50 Example :-
20°C Conditions:
15°C
12 40 process inlet w PI = 12g/kg,
10°C Process inlet T PI. = 200c
10 35°C 30
30°C Chart data :-
25°C
2 35°C
30°C 20

1.5
25°C process outlet w PO = 5g/kg,
20°C
20°C
6
Process outlet T PO. = 46.50c
15°C
1
10°C

0.5 4

15°C
0
2 4 2
10°C

0 2 4 6 8 10 12 14 16 18

PROCESS INLET AIR MOISTURE CONTENT pi(g/kg)

PRESSURE DROP CHART


30
0
50
10
PRESSURE DROP DELTA P (PROCESS) mm W.C.

00
0,

90
30

Example :-
0,
,7

20
00

,6
50

00
0,

42
00

Model FLi -5000


0,

25
i-3

50
FL

0 Process air volume = 4000 m3/h


i-2

00
FL

i-8
FL Air volume = 80%
DP (Process) = 24 mm w.c.

20

15

50% 60% 70% 80% 90% 100% 110% 120%

% NOMINAL AIR FLOW

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE


Documents No. :BAA: D0040
Date : July,01, 2007 Page 3 of 4
PERFORMANCE CHART FLi -SERIES
The fan performance curve are for inlet conditions at 20 0C, density 1.2kg/m3

2500 3000
FL i -25004200
FLC-2500 5000
FLC-3000 6200
FL i -3000 7300 FL8000
FLC-4200 9000 10500
FLC-5000
i -4200 FLC-6200
FL i -5000 FLC-7300
FL i -6200
0 FLC-8000 FLC-9000 FLC-10500
1000 336 FLi-7300
335 FLi-8000 FLi-9000 FLi-10500
1500 335 337
360
2000 325 335
2500 300 325 338
340
3000 250 300 335 340
3500 250 325 335
320
4000 305 325 338
STATIC PRESSURE (Pa)

5000 260 300 335


300
5500 250 325 338
6000 305 335
280
6500 260 325 337
7000 305 335
260
7500 260 325 337
8000 300 335
8500
240 250 325
9000 300 337
9500
220 250 335
10000 325
10500
200 300
0 1000 1500 2000 2500 3000 3500 4000 5000 5500 6000 6500 7000 7500 8000 8500 9000 9500 10000 10500 11000 11500
11000 250
11500

AIR FLOW m3/h

FEATURE OVERVIEW
Items Standard Optional

Rotor : High performance metal silicate √


High performance metal silicate (High RH) √
High performance molecular sieve (Low RH) √

Process : High capacity synthetic nonwoven mesh filter √


External box fitted with EU5 / filter √
External box fitted with EU7 / filter √
Higher static fan √
Process pre-cooler /after cooler. √
Reactivation : High capacity metallic mesh filter √
External box fitted with EU5 / filter √
External box fitted with EU7 / filter √
Higher static fan √

Energy : Electric or steam reactivation √


External box fitted with gas reactivation √

Construction : Cold drawn steel SS frame with GI internal screen & cold draw √
Stainless steel √

Control : Single stage On/Off humidstat √


Proportional humidity sensor with SSR √
Bry-Smart control √

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE