‫االدارة العامة لصرف شرق المنوفية‬

1.00‫الدراسة الهيدروليكية لتغطية مصرف العايشة عند ك‬ ‫هندسة صرف شبين الكوم‬

‫التصميم الهيدروليكي‬
input data
Q= 0.347 m3 / sec irrigated land
bc = 1 m a (land) = 1000 fedan
zc = 1.5 m ‫المقنن المائي‬ 25 m3/fedan
d
yc = 1.25 ‫صرف صحي‬
n= 1 vent Q (daily) = 0 m3/day
L= 50 m operation (h) 24 hour/day
calculations
d= 1 m
Acul act = 0.785714

Vcul act = 0.441919

check of heading up

C exit = 1
C sc = take ᶲ = 1.97 & t = 2 & b = 10
ά = 60
C sc = 0.18
C ent = 0.2 rounded wall

Cf = a = 0.003 & b =0.03 for R.C

R = 0.25

Cf = 0.672

H up = 0.020 m safe
By Eng / Ahmed Abdelbaky