The document describes the correspondence between maintenance messages displayed on a CANRIG1250 touchscreen and PLC variables. It lists 23 PLC variables and their associated maintenance messages. The messages cover topics like power supply issues, component failures, communication faults, and alarm bypass options. The numbers in the left column correspond to the message display positions and indicate how many messages each position can show.
The document describes the correspondence between maintenance messages displayed on a CANRIG1250 touchscreen and PLC variables. It lists 23 PLC variables and their associated maintenance messages. The messages cover topics like power supply issues, component failures, communication faults, and alarm bypass options. The numbers in the left column correspond to the message display positions and indicate how many messages each position can show.
The document describes the correspondence between maintenance messages displayed on a CANRIG1250 touchscreen and PLC variables. It lists 23 PLC variables and their associated maintenance messages. The messages cover topics like power supply issues, component failures, communication faults, and alarm bypass options. The numbers in the left column correspond to the message display positions and indicate how many messages each position can show.
1 N28:046/15 Operation Limited "Inverter Disconnected" 2 N28:000/00 Console Low Purge Pressure 3 N28:000/03 Console loss 24V Primary power supply 3 N28:000/04 Console loss 24V Backup power supply 3 N28:000/05 Console loss 5V Primary power supply 3 N28:000/06 Console loss 5V Backup power supply 4 N28:003/00 Top Drive Low air pressure - check blower and air intake 4 N28:003/01 Top Drive High Hydraulic Return Pressure: Check for clogged lines 4 N28:003/02 Top Drive Low Hydraulic Pressure: Check lines and HPU 4 N28:003/03 Top Drive HIGH lube temperature: Check cooler 4 N28:003/04 Top Drive Low Lube pressure: Check pump and starter 4 N28:003/05 spare 4 N28:003/06 Top Drive Loss 24V primary power supply 4 N28:003/07 Top Drive Loss 24V backup power supply 4 N28:003/08 Top Drive restricted lube filter: Check the unit and change if necessary 4 N28:003/09 Top Drive restricted hydraulic filter: Inspect if necessary replace 5 N28:000/14 CIP loss 24V Primary Power Supply 5 N28:000/15 CIP loss 24V Backup Power Supply 6 N28:001/00 HPU Hi temperature: inspect unit 6 N28:001/01 HPU Low oil level: inspect unit and add oil 6 N28:001/02 HPU pressure filter plugged: inspect unit and change if necessary 6 N28:001/03 HPU Return filter plugged:inspect unit and change if necessary 7 N28:002/03 VFD Drive Major Fault: Check Drive for problems. VFD Breaker Tripped: Check DB reistor overtemp status and voltage monitor.To 7 N28:002/04 Reset Press and Release Lockout 7 N28:002/05 VFD Drive Minor Fault: Check Drive for problems. 8 N24:059/00 All 3 Motor RTD's are out of range, Motor over temp can not be detected.Contact 8 N24:059/01 Motor RTD 1 Out of Range.If all three motor RTD's are out of range, contact 8 N24:059/02 Motor RTD 2 Out of Range.If all three motor RTD's are out of range, contact 8 N24:059/03 Motor RTD 3 Out of Range.If all three motor RTD's are out of range, contact 8 N24:059/04 Brake caliper out of range. Can not detect brake over heating. Contact Canrig 8 N24:059/05 Hydraulic manifold RTD out of range. Can not detect manifold discharge over 8 N24:059/06 Upper motor bearing RTD Out of range 8 N24:059/07 Lube Oil RTD out of range. Lube oil over temp alarm is not working 8 N24:059/08 Ambient RTD out of range, TD heater Switch in CIP will not work in Auto mode 9 N28:046/15 Operation in limited mode because of disconnected Inverter Drive Encoder Failure -- Operating in Encoderless Mode You can operate in this 10 N28:009/10 mode. Torque may not be accurate in make up mode. 11 N28:000/07 Both HPUS have Tripped out Check Motor starter in CIP 11 N28:000/08 HPU #2 has Tripped out Check Motor starter in CIP 11 N28:000/09 HPU #1 has Tripped out Check Motor starter in CIP 12 N28:001/08 Mud Saver close selection with mud pumps running 12 N28:001/09 Mud Saver close selection with more than 500 psi standpipe pressure 12 N28:001/10 Mud Saver activation prevented by neither HPU running 13 N28:001/06 LWCV close selection with mud pumps running 13 N28:001/07 LWCV close selection with more than 500 psi standpipe pressure 14 N28:001/12 BUW interlocked - hydraulic power OFF 15 N28:001/04 HPU1 not running - check starter 15 N28:001/05 HPU2 not running - check starter 16 N28:002/00 VFD Breaker over Reset Limit -- You must manually close breaker to reset limit. 16 N28:002/01 VFD Breaker Charged -- Check wiring of Breaker for charging fault. 16 N28:002/02 VFD Breaker Open -- Breaker is locked out or breaker was manualy opened. Apply to SLC500 PLC+Yaskawa VFD+PVP1250 TP Page 1 of 3 CANRIG1250触摸屏MAINTENANCE MESSAGE与PLC变量间的对应关系
16 N28:002/03 VFD Drive Fault Check Drive
16 N28:002/04 VFD Breaker Trip 16 N28:002/05 VFD Minor Faults 17 N28:003/10 Top Drive Loss both 24V power supplies 17 N28:003/11 Contacts for Blower are ON without any ENABLE signal Motor failure can/will 17 N28:003/12 Contacts for Lube Pump are ON without any ENABLE signal Motor failure can/will 17 N28:003/13 Contacts for Lube Cooler are ON without any ENABLE signal Motor failure can/will 18 N28:000/13 CIP Loss both 24V Power Supplies 19 N28:000/01 Console loss both 24V Power supplies 19 N28:000/02 Console loss both 5V Power supplies 20 N28:004/00 Blown fuse Torque Boost Disengage-RESET Blown Fuse 20 N28:004/01 Blown fuse Torque Boost Engage-RESET Blown Fuse 20 N28:004/02 Blown fuse Top Drive BRAKE-RESET Blown Fuse 20 N28:004/03 Blown fuse Handler Unlock-RESET Blown Fuse 20 N28:004/04 Blown fuse BUW Close-RESET Blown Fuse 20 N28:004/05 Blown fuse Mud Saver Open-RESET Blown Fuse 20 N28:004/06 Blown fuse Mud Saver Close-RESET Blown Fuse 20 N28:004/07 Blown fuse 24V MCC Power-RESET Blown Fuse 20 N28:004/08 Blown fuse Torque Boost Make-up-RESET Blown Fuse 20 N28:004/09 Blown fuse Torque Boost Brake-out-RESET Blown Fuse 20 N28:004/10 Blown fuse Handler Forward-RESET Blown Fuse 20 N28:004/11 Blown fuse Handler Reverse-RESET Blown Fuse 20 N28:004/12 Blown fuse Link Tilt Float-RESET Blown Fuse 20 N28:004/13 Blown fuse LWCV Open-RESET Blown Fuse 20 N28:004/14 Blown fuse LWCV Closed-RESET Blown Fuse 20 N28:004/15 Blown Fuse Elevator Open - Reset Blown Fuse 20 N28:005/00 Blown fuse Link Tilt Extend-RESET Blown Fuse 20 N28:005/01 Blown fuse Link Tilt Retract-RESET Blown Fuse 20 N28:005/02 Blown fuse BUW Up-RESET Blown Fuse 20 N28:005/03 Blown fuse BUW Down - RESET Blown Fuse 20 N28:005/04 Blown fuse 24V for Inputs I:9.19 - RESET Blown Fuse 20 N28:005/05 Blown fuse Blower Starter - Reset Blown Fuse 20 N28:005/06 Blown fuse Lube Pump Starter - Reset Blown Fuse 20 N28:005/07 Blown fuse - Lube Cooler 21 N28:018/00 Comm Fault at console -- check wiring Inside Console Comm Fault at Top Drive -- check wiring between Panelview and TD, Check 24 21 N28:018/01 Volt Power to TD 21 N28:018/02 Comm Fault at Top Drive -- No comm to Flex ASB #2 Retract 21 N28:018/03 Comm Fault at Top Drive -- No comm to Flex ASB #1 Main 21 N28:018/04 Comm Fault at VFD Drive -- No comm to VFD drive 21 N28:018/08 AC Drive U+ Gate Driver Fault -- Call Canrig (281) 259-8887 for assistance 21 N28:018/09 AC Drive U- Gate Driver Fault -- Call Canrig (281) 259-8887 for assistance 21 N28:018/10 AC Drive V+ Gate Driver Fault -- Call Canrig (281) 259-8887 for assistance 21 N28:018/11 AC Drive V- Gate Driver Fault -- Call Canrig (281) 259-8887 for assistance 21 N28:018/12 AC Drive W+ Gate Driver Fault -- Call Canrig (281) 259-8887 for assistance 21 N28:018/13 AC Drive W- Gate Driver Fault -- Call Canrig (281) 259-8887 for assistance 21 N28:018/14 AC Drive Bus Fuse Fault -- Call Canrig (281) 259-8887 for assistance 22 N28:125/14 =0 Elevator Alarm Bypass Press to Disable 22 N28:125/14 =1 Elevator Alarm Disable Press to Enable 23 N28:009/10 =0 Press to Switch to Encoderless 23 N28:009/10 =1 Press to Switch to Normal Operation
Apply to SLC500 PLC+Yaskawa VFD+PVP1250 TP Page 2 of 3
Gas-Engines and Producer-Gas Plants
A Practice Treatise Setting Forth the Principles of Gas-Engines and Producer Design, the Selection and Installation of an Engine, Conditions of Perfect Operation, Producer-Gas Engines and Their Possibilities, the Care of Gas-Engines and Producer-Gas Plants, with a Chapter on Volatile Hydrocarbon and Oil Engines