Description
All the terminal/Junction boxes have been licensed by European Union standard. They
are manufactured in accordance with EN 60079-7 “Ex e” standard. “Ex e”
Terminal/Junction boxes ensure reliable prevention of unacceptably high temperatures
and sparks or electrical arcs, both on the internal and on the external parts of electrical
equipment whose normal operation does not involve unacceptably high temperature
sparks or arching. The following components can be mounted into enclosures and all
internally mounted components are within the area of the baseboard but in small sizes
mounted by weld stud on the internal surface of the enclosure.
Bus-bars
Ex Terminals
Cells and batteries are not permitted in the enclosure.
1
Safety User Manual Exe Enclosure
Technical data
Model Type of protection Temperature Class Zone IP Material
SJB-140 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-200 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-270 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-280 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-310 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-350 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-380 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-410 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-450 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-500 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-600 Ex eb IIC T6 1,2,21,22 66 Stainless steel
SJB-700 Ex eb IIC T6 1,2,21,22 66 Stainless steel
2
Safety User Manual Exe Enclosure
The maximum permitted internal power dissipations (in Watts) for various temperature
classes, are as follows:
Model -20˚C≤Tamb≤+40˚C -20˚C≤Tamb≤+55˚C
T6 T85 T100 T6 T85 T100
SJB 140 7.1 W 20 W 29.5 W 4.2 W 12.55 W 20 W
SJB 200 10.9 W 35 W 45.5 W 6.5 W 15.5 W 35 W
SJB 270 29.5 W 82.5 W 129.5 W 17 W 67.5 W 82.5 W
SJB 280 29.3 W 45 W 74.5 W 15.3 W 22.5 W 45 W
SJB 310 30 W 60 W 99.5 W 16 W 39 W 60 W
SJB 350 50 W 74 W 171.5 W 28.5 W 62.5 W 74 W
SJB 380 55.5 W 104 W 144.5 W 34.7 W 64.5 W 104 W
SJB 410 67 W 142.5 W 210.5 W 38 W 80.5 W 142.5 W
SJB 450 90 W 197 W 298 W 51.5 W 96.5 W 197 W
SJB 500 97.8 W 207.5 W 259 W 61.1 W 97 W 207.5 W
SJB 600 133 W 255.5 W 380.5 W 83 W 151.5 W 255.5 W
SJB 700 166.5 W 332 W 477 W 79.9 W 134 W 332 W
3
Safety User Manual Exe Enclosure
1 42 40 33 26 21 18 16 13 10 8
Horizontal 2 84 80 66 52 42 36 32 0 0 0
SJB410 3 126 120 99 78 63 0 0 0 0 0
Vertical 1 60 55 45 36 29 26 22 17 14 11
2 120 110 90 72 58 52 44 0 0 0
1 52 48 39 31 25 22 19 15 12 10
2 104 96 78 62 50 44 38 30 0 0
Horizontal
3 156 144 117 93 0 0 0 0 0 0
SJB450 4 208 192 0 0 0 0 0 0 0 0
1 67 62 50 40 32 29 24 19 16 13
Vertical 2 134 124 100 80 64 58 48 0 0 0
3 201 186 150 0 0 0 0 0 0 0
1 50 46 38 30 24 21 18 14 12 9
2 100 92 76 60 48 42 36 28 24 0
Horizontal
3 150 138 114 90 72 63 54 0 0 0
4 200 184 152 0 0 0 0 0 0 0
SJB500
1 70 65 53 42 34 30 25 20 16 13
Vertical 2 140 130 106 84 68 60 50 40 0 0
3 210 195 159 126 0 0 0 0 0 0
1 59 54 44 35 28 25 21 17 14 11
2 118 108 88 70 56 50 42 34 28 22
Horizontal 3 177 162 132 105 84 75 63 51 42 0
4 236 216 176 140 0 0 0 0 0 0
SJB600 5 295 270 220 0 0 0 0 0 0 0
1 92 85 69 55 44 39 33 27 22 18
Vertical 2 184 170 138 110 88 78 66 54 0 0
3 276 255 207 165 0 0 0 0 0 0
1 68 63 51 41 33 29 25 20 16 13
2 136 126 102 82 66 58 50 40 32 26
3 204 189 153 123 99 87 75 60 0 0
Horizontal 4 272 252 204 164 132 116 100 0 0 0
5 340 315 255 205 0 0 0 0 0 0
6 408 378 306 0 0 0 0 0 0 0
SJB700
1 104 96 78 62 49 44 37 30 24 20
2 208 192 156 124 98 88 74 60 0 0
Vertical
3 312 288 234 186 0 0 0 0 0 0
4 416 384 312 0 0 0 0 0 0 0
The maximum number of cable entries on four sides of each size are as follows:
4
Safety User Manual Exe Enclosure
SJB410 55 40 26 18 14 9 6 40 32 18 15 11 6 4
SJB450 43 36 26 17 12 10 6 38 32 18 14 11 8 5
SJB500 52 48 24 15 12 10 4 40 21 18 10 10 8 3
SJB600 75 52 30 23 17 12 7 50 36 21 14 11 8 5
SJB700 68 52 33 21 16 14 5 56 48 24 15 12 10 4
Marking
Maximum Voltage
Date of production
Serial number of product Maximum Current
Ambient temperature
Zone 1,2 Surface temperature
Group II
5
Safety User Manual Exe Enclosure
Date of production
General information
Energized parts
6
Safety User Manual Exe Enclosure
The electrical junction box should be installed in accordance IEC 60079-14. Observe
following instructions for installation of the enclosure:
This enclosure has after sales service and quality assurance so notify any defects
caused by transporting.
Only qualified personnel are allowed to perform installation and maintenance tasks
to this product.
Use in ambient temperature -20°C to +55°C.
Use stainless steel brackets and bolts for installation the enclosure.
7
Safety User Manual Exe Enclosure
Guarantee includes: