Professional Documents
Culture Documents
UltimaPro 33 Series LV UPS Brochure - 221114-1
UltimaPro 33 Series LV UPS Brochure - 221114-1
UltimaPro 33 Series LV UPS Brochure - 221114-1
• Power factor 1.0 ensures advanced performance • Built-in Maintenance bypass function
The maintenance bypass function keeps the UPS running to
• Smart dual inputs function to support automatic switching
supply power to connected equipment without interruption
between various inputs while being serviced.
www.MarusonUSA.com Info@MarusonUSA.com
• Very powerful charger • 3-stage extendable charging design for optimized
UltimaPro 33 series is built-in 12A charger for 10K/15K/20KVA battery performance
models and 16A charger for 30K/40KVA models. The The charge circuit uses a 3-stage battery charge method:
higher charge current is best suited for long runtime models Constant Current, Constant Voltage, and Floating to optimize
connected to large capacity external battery cabinets to battery performance.
recharge batteries faster than standard models. • Adjustable battery numbers design
The number of connected batteries can be adjusted based on
• Smart dual inputs function
different power demands. This feature can allow the UPS to
Built-in dual inputs function supports automatic switching keep running even if some battery packs are damaged.
between various inputs and allows flexibility for system
configuration. ■ Support both 3P/3P and 3P/1P operation (10KVA model)
■ SNMP + USB multiple communication options This UPS can support 3P/3P and 3P/1P operation to meet the
needs of different type equipments.
This UPS includes multiple built-in communication options,
including USB and intelligent slot. The included software • 4.3" Touchscreen LCD for comprehensive UPS information
provides a complete power solution to monitor and control the
UPS on-site, while the optional network management card is
convenient for off-site power management and monitoring.
Admissible Output Overload 110% for 60min; 130% for 1min; >130% for 1 second @ AC mode
110% for 30 seconds; 130% for 10 seconds; >130% for 1 second @ Batt. mode
Battery Numbers (Long-run Model) 16 ~ 20 pcs (Adjustable)
Charging Voltage (Long-run Model) ±13.65 VDC x N (N = 8 ~ 10)
LCD Display UPS status, Load level, Battery level, Input / Output voltage, Discharge timer, and Fault conditions
Communication Port Smart USB
Optional SNMP Power management from SNMP manager and web browser
Standard The UPS comply to UL1778, CSA C22.2 No. 107.3, FCC Part 15 Class A (EMC)
Product specifications are subject to change without further notice.