PerkinElmer FTIR Spectrum TWO SP2:

Model Spectrum TWO SP2

Country of Origin: EU/USA/Singapore

Ite Description Part No. Qty.


m
1 Spectrum Two FT-IR/Sp10 Software, DTGS L160000E 1
The Spectrum Two spectrometer based on a new DynaScan
interferometer, KBr optics and a temperature-stabilized DTGS detector
delivers a scan range of 8,300-350cm-1 whilst offering 0.5cm-1
resolution and 14,500:1 peak-peak, 5 seconds 50,000:1 peak-peak 1
minute scan in a sleek, compact design.
The Spectrum Two system includes basic transmission mode
functionality as standard (sample holder)
Features:

A unique humidity shield design protects Spectrum Two from


environmental effects allowing it to be used in more challenging
environments, and with extended intervals between desiccant changes to
lower maintenance costs.

AVC features an advanced digital filtering algorithm designed to subtract


CO2 and H2O absorptions automatically in real time.

The use of Sigma-Delta converters in the digitization of the FT-IR


interferogram improves dynamic range, reduces spectral artifacts and
increases ordinate linearity.
Includes basic transmission functionality with optional fully integrated,
robust universal sampling ensures trouble-free measurements. Also
available are an optional portability pack (including carry case, Wi-Fi
router and battery pack) for remote testing and optional introductory and
application packs for faster implementation.
The included Spectrum 10 software suite is fully validated and includes
the following functionality:

Page (1) Of (4)


Instrument dimensions 450 mm W x 300 mm D x 210 m H, Mass 13Kg.
Supplied with mains cable, Ethernet and USB cables, electronic user’s and
maintenance guide on CD, certificate of conformity and fuses. Includes one
year warranty and customer installation guide (additional on-site installation
and warranties optional). Requires PC. Suitable for 100240V, 50/60 Hz
operation.
OPTICAL PERFORMANCE
Wavelength Range 8,300 – 350 cm-1 optimized, proprietary KBr
beamsplitter 6500-550 cm-
1 with ZnSe
optics
Spectral Resolution 0.5 cm-1 standard
Wavelength Precision Better than 0.01 cm-1 at 3000 cm-1
Wavelength Accuracy 0.1 cm-1 at 3000 cm-1
Signal-to-noise 14,500:1 peak-peak, 5 seconds
OPTICAL SYSTEM
General Long-life sealed and desiccated optical unit incorporating
OpticsguardTM design, Vibration isolated baseplate.
Interferometer Rotary Michelson interferometer, High stability, self-
compensating for dynamic alignment changes due to a tilt and shear

Optics Kinematically mounted, zero alignment optics , with high reflectivity


and a low-angle off axis design. Proprietary
OpticsGuard system for extended desiccant life and additional optical
component protection.
Detectors High linearity room temperature detector (standard)
Temperature-stabilised room temperature DTGS detector optional.
Source Long-life source with proprietary hot-spot stabilization. User
replaceable from outside instrument
Beamsplitter Proprietary extended range KBr.
Desiccant Long-life desiccant system accepts disposable packs. Software
controlled desiccant status indicator.
Validation Software controlled validation wheel option containing a
polystyrene reference material, traceable to a NIST standard for
wavenumber accuracy and a Schott NG11 filter for ordinate repeatability.
Optical Windows KBr (standard), ZnSe option for exceptionally high
humidity environments

Page (2) Of (4)


DATA SYSTEM AND ELECTRONICS
Signal sampling Over-sampling delta-sigma converter.
Communication USB, wireless and TCP/IP interface allows direct
connection with LAN.
Instruments can be configured with wireless router communication.
Calibration Transfer Absolute Virtual Instrument (AVI) option – actively
standardizes instrument response to further improve repeatability and
protect data integrity. Atmospheric compensation Minimizes effect of
atmospheric water and CO2 on the sample spectra without the need for
reference or calibration spectra. Operates at various instrument setttings
without having to recalibrate the correction.

Accessory recognition Spectrum Two accessories are automatically


detected as soon as they are locked into the sampling area. Instrument
parameters are optimized for the installed accessory. Accessories
information stored with spectral data.
Error Trapping All sample spectra are checked for common spectroscopic
and sampling problems. Key instrument components are continuously
monitored.
Component Checks Individual component checks under software control
can be executed on-demand or automatically scheduled at preset
times/intervals
Powersave mode Instrument standby and power-up can be automatically
scheduled.
2 POWER CORD, UNITED KINGDOM 09991414 1
3 DELL PC Special 1
4 HP Laser Printer Special 1
5 UATR Diamond/ZnSe ATR (Single Reflection) L160010 1
7
For direct analysis of both solid and liquid samples , without sample
prep
The universal ATR is an excellent general accessory for the analysis
of solids and liquids. The UATR produces high quality spectra through the
use of a pressure arm allowing good contact of the sample with the
diamond crystal. The pressure arm force indicator ensures first-class
sample-to-sample and operator-to-operator reproducibility.
Features of the UATR include:

the Universal ATR module is recognized along with its unique number, and
system suitability checks can be carried out.

be used without any alignment necessary.

the instrument once installed.

force readout in Spectrum ensures good contact before scanning


6 Transmission Sample Holder already included in Item 1 1

Page (3) Of (4)


7 Desiccant kit for Spectrum TWO L160024 1
4
8 First Year Warranty included WRNTY 1
9 Installation and basic operational training Special 1

Page (4) Of (4)