PART A 2 MARKS

List down the types of loads distributed on a structure.


What are the Environmental loads?
Define RCC.
How will find a slab as one way or two-way slab?
Expand HYSD bars.
What are the types of Beams?
What are the imposed-on columns?
List out the different types of columns.
Sketch and explain Isolated footing.
List out the types of Footing.

What is meant by RCC?


What are the types of loads?
Define Factor of Safety.
Define one way and two-way slab.
Expand HYSD bars.
Define cover distance.
Draw sketch of uniaxial and biaxial column.
Write down the formula for ultimate moments and shear forces.
What are the factors for selecting the types of footing?
Draw a neat sketch of strap footing.

List out the 3 major design method.


Draw the stress strain curve for concrete.
Define PCC and RCC
What is the formula used to find one way slab and two-way slab.
Define Flanged beam.
Mention the parameter of flanged beam with sketch.
Draw L and T section columns.
Draw the uniaxial and biaxial loading of column.
What are the types of Isolated footing?
Draw a neat sketch of strip footing.

PART B 6 MARKS
1. Write a note on Limit state method of design.
Draw a neat sketch of different types of loads acting on a structure.
2. Draw the reinforcement details of one way and two-way slab with their sectional view.
Draw the load distribution in one way slab and two-way slab.
3. Compare singly reinforced beam and doubly reinforced beam.
Write a note on check for shear with formula.
4. Explain about uniaxial and biaxial column.
Draw and explain different types of columns.
5. Draw and explain about the mat or raft footing.
Explain about the types of strap footing.

1. Write short notes on working stress method of design.


How the load distribution mechanism in one way slab and two-way slab happens. Explain
2. Draw the reinforcement details of two-way slab with their sectional view.
Compare one way slab and two-way slab.
3. Differentiate singly reinforced beam and doubly reinforced beam.
Write a note on Flanged beam with sketches.
4. Explain briefly about circular column purpose and uses.
Explain the classification of column based on the reinforcement.
5. Draw and explain about the combined footing.
List out the different types of footing.

1. Write short notes on Limit state method of design.


Draw a neat sketch about the load distribution in a structure.
2. Draw the reinforcement details of one-way slab with their sectional view.
Write the advantages two-way slab over one way slab.
3. Compare singly reinforced beam and doubly reinforced beam.
Explain in detail about the flanged beam.
4. Write down the primary Types of columns.
List out the classification of column based on the shape.
5. Write about strap and combined footing.
Define footing. What are the factor to consider for selection of footing.

PART C 10 MARKS

1. Explain briefly about the Loads on structure & Load transfer mechanism.
Explain briefly about the advantages of limit state method over the working stress method.
2. Design a one-way slab with a clear span of 3.5m, simply supported on 200 mm thick
concrete masonry walls to support a live load of 4 kN/m2. Adopt M20 grade concrete and
Fe 415 HYSD bars.
Design a simply supported RCC slab for an office floor having clear dimensions of 4 m × 6m
with 230 mm walls all-round. Adopt M20 grade concrete and Fe 415 grade HYSD bars.
Assume the live load as 4 kN/m2.
3. Design a singly reinforced concrete beam to suit the following data.
Clear span: 4m
Width of supports: 300mm.
Service load: 5KN/m2
Materials: M20 grade concrete
Fe 415 HYSD bars
A reinforced concrete beam is to be designed over an effective span of 5m to support a design
service load of 8 kN/m. Adopt M20 grade concrete and Fe415 HYSD bars and design the beam
to satisfy the collapse and serviceability limit states.
4. A rectangular reinforced concrete column of cross-sectional dimensions 300mm by
600mm is to be designed to support an ultimate load of 200kN. Design suitable
reinforcements in the column using M20 grade concrete and Fe 415 HYSD bars.

Write the design procedure of a circular column with all the formula.
5. A rectangular RCC column of size 300mm X 450mm carrying an axial load of 1500kN.
If the safe bearing capacity of the soil is 120 kN/m2. Design a suitable footing. Consider
M25 grade concrete and Fe415 grade steel.
Design a reinforced concrete circular footing for a circular column of 300 mm diameter
supporting a factored axial load of 750kN. Adopt the safe bearing capacity of the soil as 250
kN/m2. Use M20 grade concrete and Fe415 HYSD bars.

1. Draw and explain about the different types of loads acting on a structure.

Explain briefly about the Load on structure and load transfer mechanism in Framed structure.
2. Design a two-way slab for an office floor of size 3.5 m by 4.5 m with discontinuous and
simply supported edges on all the sides with corners prevented from lifting and
supporting a service live load of 4 kN/m2. Adopt M20 grade concrete and Fe 415 HYSD
bars.

Design a one-way slab with a clear span of 4.5m, simply supported on 300 mm thick concrete
masonry walls to support a live load of 5 kN/m2. Adopt M20 grade concrete and Fe 415 HYSD
bars.
3. Design a reinforced concrete beam of rectangular section using the following data:
Effective span: 5m
Width of beam: 250 mm
Overall depth: 500 mm
Service load (DL+LL): 40 kN/m
Effective cover: 50 mm
Materials: M 20 grade concrete
Fe-415 HYSD bars

Design a singly reinforced concrete beam to suit the following data.


Clear span: 5m
Width of supports: 300mm.
Service load: 10 KN/m2
Materials: M20 grade concrete
Fe 415 HYSD bars
4. A rectangular reinforced concrete column of cross-sectional dimensions 200mm by
400mm is to be designed to support an ultimate load of 300kN. Design suitable
reinforcements in the column using M20 grade concrete and Fe 415 HYSD bars.

Write the design procedure of a rectangular column with all the formula.
5. Design a reinforced concrete footing for a rectangular column of section 300mm by
500mm supporting an axial factored load of 1500 kN. The safe bearing capacity of the
soil at site is 185 kN/m2. Adopt M20 grade concrete and Fe 415 HYSD bars.

Write down the design procedure of a reinforced concrete circular footing.

1. Compare limit state method and working stress method.

Explain briefly about the characteristic load and characteristic strength of materials.
2. Design a one-way slab with a clear span of 5m, simply supported on 200 mm thick
concrete masonry walls to support a live load of 4 kN/m2. Adopt M20 grade concrete and
Fe 415 HYSD bars.
Design a one-way slab with clear span of 3.5m, simply supported on 200mm thick concrete
masonry walls to support a live load of 4kN/m2. Adopt M 20 grade of concrete and Fe 415
HYSD bars.
3. Design a singly reinforced concrete beam to suit the following data.
Clear span: 6m
Width of supports: 300 mm.
Service load: 15 KN/m2
Materials: M20 grade concrete
Fe 415 HYSD bars

A reinforced concrete rectangular simply supported beam of 300mm X 535mm effective section
with 4 bars of 20mm diameter steel of grade Fe415 carries a total uniformly distributed load of
25 kN/m. Using limit state method of design with a load factor of 1.5.
4. A rectangular reinforced concrete column of cross-sectional dimensions 300mm by
600mm is to be designed to support an ultimate load of 300kN. Design suitable
reinforcements in the column using M20 grade concrete and Fe 415 HYSD bars.

Design the reinforcements in a short column 400mm X 400mm at the corner of a multistoreyed
building to support an axial factored load of 1500 kN, together with biaxial moments of 50 kNm
acting in perpendicular planes. Adopt M20 grade concrete and Fe415 HYSD bars.
5. A rectangular RCC column of size 300mm X 600mm carrying an axial load of 2000kN.
If the safe bearing capacity of the soil is 150 kN/m2. Design a suitable footing. Consider
M25 grade concrete and Fe415 grade steel.

Write down the design procedure of a isolated pad footing.