This document contains log entries from a network management card monitoring a Smart-UPS SRT 5000 UPS over time. It logs user logins and logouts to the interface, UPS events like bypass mode or low battery notifications, and battery replacement recommendations. The UPS is configured with switched outlet groups and has experienced issues with its internal battery pack not being installed properly.
This document contains log entries from a network management card monitoring a Smart-UPS SRT 5000 UPS over time. It logs user logins and logouts to the interface, UPS events like bypass mode or low battery notifications, and battery replacement recommendations. The UPS is configured with switched outlet groups and has experienced issues with its internal battery pack not being installed properly.
This document contains log entries from a network management card monitoring a Smart-UPS SRT 5000 UPS over time. It logs user logins and logouts to the interface, UPS events like bypass mode or low battery notifications, and battery replacement recommendations. The UPS is configured with switched outlet groups and has experienced issues with its internal battery pack not being installed properly.
09/06/2023 08:43:26 apc Web user 'apc' logged in from 10.60.250.137. 0x0015 09/06/2023 06:57:21 System Web user 'apc' logged out from 10.60.7.21. 0x001F 09/06/2023 06:54:14 apc Web user 'apc' logged in from 10.60.7.21. 0x0015 09/06/2023 05:35:40 System Web user 'apc' logged out from 10.60.250.137. 0x001F 09/06/2023 05:32:40 apc Web user 'apc' logged in from 10.60.250.137. 0x0015 09/06/2023 05:31:56 System Web user 'apc' logged out from 10.60.250.137. 0x001F 09/06/2023 05:30:05 Device UPS: In bypass in response to the UPS front- panel or a user-initiated software command, typically for maintenance. 0x011C 09/06/2023 05:28:07 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 09/06/2023 05:27:33 Device UPS: The battery power is too low to support the load; if power fails, the UPS will be shut down immediately. 0x0107 09/06/2023 05:27:33 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 09/06/2023 05:27:33 Device UPS: Restored the local network management interface-to-UPS communication. 0x0101 09/06/2023 05:27:25 apc Web user 'apc' logged in from 10.60.250.137. 0x0015 09/06/2023 05:27:09 System Network service started. IPv6 address FE80::2A29:86FF:FE04:AC8B assigned by link-local autoconfiguration. 0x0007 09/06/2023 05:27:07 System Network service started. System IP is 10.60.7.144 from manually configured settings. 0x0007 09/06/2023 05:27:03 System Network Interface coldstarted. 0x0001 09/06/2023 05:26:30 Device UPS: A battery charger fault exists. 0x012A 09/06/2023 05:26:24 Device UPS: A battery charger fault no longer exists. 0x012B 09/06/2023 05:25:47 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 09/06/2023 05:25:13 Device UPS: The output power is turned off. 0x0114 09/06/2023 05:25:13 Device UPS: The graceful shutdown period has ended. 0x014F 09/06/2023 05:25:13 Device UPS: The power for switched outlet group 2, Outlet Group 2, is off. 0x0186 09/06/2023 05:25:13 Device UPS: The power for switched outlet group 1, Outlet Group 1, is off. 0x0186 09/06/2023 05:25:13 Device UPS: The battery power is too low to support the load; if power fails, the UPS will be shut down immediately. 0x0107 09/06/2023 05:25:13 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 09/06/2023 05:25:13 Device UPS: A battery charger fault exists. 0x012A 09/06/2023 05:25:13 Device UPS: Restored the local network management interface-to-UPS communication. 0x0101 09/06/2023 05:24:49 System Network service started. IPv6 address FE80::2A29:86FF:FE04:AC8B assigned by link-local autoconfiguration. 0x0007 09/06/2023 05:24:48 System Network service started. System IP is 10.60.7.144 from manually configured settings. 0x0007 09/06/2023 05:24:43 System Network Interface coldstarted. 0x0001 09/06/2023 05:18:34 apc Web user 'apc' logged in from 10.60.250.137. 0x0015 09/06/2023 05:18:27 Device UPS: The output power is turned off. 0x0114 09/06/2023 05:18:27 Device UPS: The graceful shutdown period has ended. 0x014F 09/06/2023 05:18:27 Device UPS: The power for switched outlet group 2, Outlet Group 2, is off. 0x0186 09/06/2023 05:18:27 Device UPS: The power for switched outlet group 1, Outlet Group 1, is off. 0x0186 09/06/2023 05:18:27 Device UPS: The battery power is too low to support the load; if power fails, the UPS will be shut down immediately. 0x0107 09/06/2023 05:18:27 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 09/06/2023 05:18:27 Device UPS: A battery charger fault exists. 0x012A 09/06/2023 05:18:26 Device UPS: Restored the local network management interface-to-UPS communication. 0x0101 09/06/2023 05:18:03 System Network service started. IPv6 address FE80::2A29:86FF:FE04:AC8B assigned by link-local autoconfiguration. 0x0007 09/06/2023 05:18:01 System Network service started. System IP is 10.60.7.144 from manually configured settings. 0x0007 09/06/2023 05:17:57 System Network Interface coldstarted. 0x0001 09/06/2023 05:16:42 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 09/06/2023 05:16:10 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 09/06/2023 05:16:10 Device UPS: Battery life exceeded cleared. 0x018D 09/06/2023 05:15:51 Device UPS: A battery charger fault exists. 0x012A 09/06/2023 05:15:48 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 09/06/2023 05:15:45 Device UPS: A battery charger fault no longer exists. 0x012B 09/06/2023 04:57:12 apc Web user 'apc' logged in from 10.60.250.137. 0x0015 09/06/2023 04:21:42 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 09/06/2023 04:21:37 Device UPS: Internal pack disconnected cleared. 0x01A1 09/06/2023 04:21:09 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 09/06/2023 04:21:08 Device UPS: The power for switched outlet group 2, Outlet Group 2, is now turned off. 0x0135 09/06/2023 04:21:08 Device UPS: The power for switched outlet group 1, Outlet Group 1, is now turned off. 0x0135 09/06/2023 04:21:08 Device UPS: A battery charger fault exists. 0x012A 09/06/2023 04:21:07 Device UPS: The output power is turned off. 0x0114 09/06/2023 04:21:07 Device UPS: The graceful shutdown period has ended. 0x014F 09/06/2023 04:20:53 Device UPS: Internal pack disconnected. 0x01A0 09/05/2023 21:06:43 System NTP update successful. 0x004A 09/04/2023 23:17:11 Device UPS: Self-Test passed. 0x01D2 09/04/2023 23:16:50 Device UPS: Self-Test started by automatic timer. 0x0137 09/01/2023 23:10:20 Device UPS: Battery life exceeded cleared. 0x018D 09/01/2023 01:06:26 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 09/01/2023 01:05:48 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 09/01/2023 01:05:42 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 09/01/2023 01:05:42 Device UPS: Battery life exceeded cleared. 0x018D 08/31/2023 22:49:59 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 08/31/2023 21:11:48 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/31/2023 21:10:56 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 08/31/2023 21:10:56 Device UPS: Battery life exceeded cleared. 0x018D 08/31/2023 21:09:00 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 08/31/2023 20:51:49 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/31/2023 20:51:14 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 08/31/2023 20:51:14 Device UPS: Battery life exceeded cleared. 0x018D 08/31/2023 20:42:13 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 08/31/2023 20:38:49 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/31/2023 20:37:55 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 08/31/2023 20:37:55 Device UPS: Battery life exceeded cleared. 0x018D 08/31/2023 18:11:55 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 08/31/2023 18:11:49 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/31/2023 18:11:11 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 08/31/2023 18:11:11 Device UPS: Battery life exceeded cleared. 0x018D 08/31/2023 17:57:49 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 08/31/2023 17:57:49 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/31/2023 17:57:30 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 08/31/2023 17:57:30 Device UPS: Battery life exceeded cleared. 0x018D 08/30/2023 04:03:07 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 08/30/2023 04:02:50 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/30/2023 04:02:29 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 08/30/2023 04:02:29 Device UPS: Battery life exceeded cleared. 0x018D 08/30/2023 03:59:33 Device UPS: Internal pack, cartridge 1 is installed. 0x0130 08/30/2023 03:58:50 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/30/2023 03:58:49 Device UPS: Internal pack, cartridge 1 is not installed. 0x012F 08/28/2023 01:11:04 Device UPS: No longer on battery power. 0x010A 08/28/2023 01:11:04 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 08/28/2023 00:52:56 Device UPS: Bypass not in range ; distorted waveform. 0x020F 08/28/2023 00:52:55 Device UPS: On battery power in response to low input voltage. 0x0109 08/27/2023 02:34:15 Device UPS: No longer on battery power. 0x010A 08/27/2023 02:34:14 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 08/27/2023 02:32:46 Device UPS: Bypass not in range ; distorted waveform. 0x020F 08/27/2023 02:32:46 Device UPS: On battery power in response to distorted input. 0x0109 08/27/2023 02:19:38 Device UPS: No longer on battery power. 0x010A 08/27/2023 02:19:37 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 08/27/2023 02:18:48 Device UPS: Bypass not in range ; distorted waveform. 0x020F 08/27/2023 02:18:48 Device UPS: On battery power in response to rapid change of input. 0x0109 08/22/2023 21:06:33 System NTP update successful. 0x004A 08/21/2023 23:17:36 Device UPS: Self-Test passed. 0x01D2 08/21/2023 23:17:15 Device UPS: Self-Test started by automatic timer. 0x0137 08/20/2023 22:45:04 Device UPS: Battery life exceeded cleared. 0x018D 08/08/2023 21:06:36 System NTP update successful. 0x004A 08/07/2023 23:18:14 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 08/07/2023 23:18:01 Device UPS: Self-Test passed. 0x01D2 08/07/2023 23:17:40 Device UPS: Self-Test started by automatic timer. 0x0137 07/25/2023 21:06:27 System NTP update successful. 0x004A 07/24/2023 23:19:02 Device UPS: Self-Test passed. 0x01D2 07/24/2023 23:18:41 Device UPS: Self-Test started by front panel. 0x0137 07/24/2023 23:18:40 Device UPS: Battery life exceeded cleared. 0x018D 07/20/2023 02:16:34 Device UPS: No longer on battery power. 0x010A 07/20/2023 02:16:33 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 07/20/2023 00:46:11 Device UPS: On battery power in response to distorted input. 0x0109 07/20/2023 00:46:11 Device UPS: Bypass not in range ; distorted waveform. 0x020F 07/15/2023 07:37:03 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 07/11/2023 23:24:40 Device UPS: Self-Test passed. 0x01D2 07/11/2023 23:24:19 Device UPS: Self-Test started by front panel. 0x0137 07/11/2023 21:06:00 System NTP update successful. 0x004A 07/01/2023 07:37:28 Device UPS: Battery life exceeded cleared. 0x018D 07/01/2023 03:35:20 Device UPS: No longer on battery power. 0x010A 07/01/2023 03:35:19 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 07/01/2023 03:32:04 Device UPS: On battery power in response to distorted input. 0x0109 07/01/2023 03:32:04 Device UPS: Bypass not in range ; distorted waveform. 0x020F 07/01/2023 00:56:52 Device UPS: No longer on battery power. 0x010A 07/01/2023 00:56:52 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 07/01/2023 00:54:20 Device UPS: On battery power in response to distorted input. 0x0109 07/01/2023 00:54:20 Device UPS: Bypass not in range ; distorted waveform. 0x020F 06/29/2023 23:56:03 Device UPS: Self-Test passed. 0x01D2 06/29/2023 23:55:43 Device UPS: Self-Test started by automatic timer. 0x0137 06/29/2023 23:54:54 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 06/27/2023 21:05:55 System NTP update successful. 0x004A 06/15/2023 23:56:25 Device UPS: Self-Test passed. 0x01D2 06/15/2023 23:56:04 Device UPS: Self-Test started by front panel. 0x0137 06/15/2023 23:55:40 Device UPS: Self-Test passed. 0x01D2 06/15/2023 23:55:19 Device UPS: Self-Test started by front panel. 0x0137 06/15/2023 23:55:15 Device UPS: Battery life exceeded cleared. 0x018D 06/14/2023 03:37:04 Device UPS: No longer on battery power. 0x010A 06/14/2023 03:37:04 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 06/14/2023 03:35:01 Device UPS: Bypass not in range ; distorted waveform. 0x020F 06/14/2023 03:35:01 Device UPS: On battery power in response to distorted input. 0x0109 06/14/2023 01:11:18 Device UPS: No longer on battery power. 0x010A 06/14/2023 01:11:18 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 06/14/2023 01:09:08 Device UPS: Bypass not in range ; distorted waveform. 0x020F 06/14/2023 01:09:08 Device UPS: On battery power in response to distorted input. 0x0109 06/13/2023 21:05:56 System NTP update successful. 0x004A 06/06/2023 22:38:49 Device UPS: Self-Test passed. 0x01D2 06/06/2023 22:38:28 Device UPS: Self-Test started by automatic timer. 0x0137 05/30/2023 21:05:27 System NTP update successful. 0x004A 05/25/2023 03:25:52 Device UPS: No longer on battery power. 0x010A 05/25/2023 03:25:51 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/25/2023 03:25:00 Device UPS: On battery power in response to distorted input. 0x0109 05/25/2023 03:25:00 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/25/2023 02:17:45 Device UPS: No longer on battery power. 0x010A 05/25/2023 02:17:43 Device UPS: On battery power in response to distorted input. 0x0109 05/25/2023 01:29:53 Device UPS: No longer on battery power. 0x010A 05/25/2023 01:29:52 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/25/2023 01:29:13 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/25/2023 01:29:12 Device UPS: On battery power in response to low input voltage. 0x0109 05/23/2023 22:39:14 Device UPS: Self-Test passed. 0x01D2 05/23/2023 22:38:54 Device UPS: Self-Test started by automatic timer. 0x0137 05/21/2023 21:44:42 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 05/16/2023 21:05:18 System NTP update successful. 0x004A 05/09/2023 22:39:39 Device UPS: Self-Test passed. 0x01D2 05/09/2023 22:39:18 Device UPS: Self-Test started by automatic timer. 0x0137 05/07/2023 21:45:05 Device UPS: Battery life exceeded cleared. 0x018D 05/02/2023 21:05:20 System NTP update successful. 0x004A 04/25/2023 22:40:03 Device UPS: Self-Test passed. 0x01D2 04/25/2023 22:39:42 Device UPS: Self-Test started by automatic timer. 0x0137 04/23/2023 07:19:08 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 04/18/2023 21:04:31 System NTP update successful. 0x004A 04/11/2023 22:40:26 Device UPS: Self-Test passed. 0x01D2 04/11/2023 22:40:05 Device UPS: Self-Test started by front panel. 0x0137 04/09/2023 07:20:29 Device UPS: Self-Test passed. 0x01D2 04/09/2023 07:20:08 Device UPS: Self-Test started by front panel. 0x0137 04/09/2023 07:19:57 Device UPS: Self-Test passed. 0x01D2 04/09/2023 07:19:37 Device UPS: Self-Test started by front panel. 0x0137 04/09/2023 07:19:33 Device UPS: Battery life exceeded cleared. 0x018D 04/04/2023 21:03:51 System NTP update successful. 0x004A 04/02/2023 18:05:49 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 03/29/2023 22:38:14 Device UPS: Self-Test passed. 0x01D2 03/29/2023 22:37:53 Device UPS: Self-Test started by front panel. 0x0137 03/29/2023 22:37:20 Device UPS: Self-Test passed. 0x01D2 03/29/2023 22:36:59 Device UPS: Self-Test started by front panel. 0x0137 03/21/2023 21:03:57 System NTP update successful. 0x004A 03/20/2023 21:22:12 Device UPS: Self-Test passed. 0x01D2 03/20/2023 21:21:52 Device UPS: Self-Test started by automatic timer. 0x0137 03/19/2023 18:06:13 Device UPS: Battery life exceeded cleared. 0x018D 03/18/2023 02:16:28 Device UPS: No longer on battery power. 0x010A 03/18/2023 02:16:27 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 03/18/2023 02:10:18 Device UPS: Bypass not in range ; distorted waveform. 0x020F 03/18/2023 02:10:18 Device UPS: On battery power in response to distorted input. 0x0109 03/18/2023 01:23:15 Device UPS: No longer on battery power. 0x010A 03/18/2023 01:23:14 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 03/18/2023 01:00:17 Device UPS: Bypass not in range ; distorted waveform. 0x020F 03/18/2023 01:00:16 Device UPS: On battery power in response to distorted input. 0x0109 03/17/2023 22:59:47 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 03/07/2023 21:03:50 System NTP update successful. 0x004A 03/06/2023 21:22:38 Device UPS: Self-Test passed. 0x01D2 03/06/2023 21:22:17 Device UPS: Self-Test started by automatic timer. 0x0137 03/03/2023 23:00:11 Device UPS: Battery life exceeded cleared. 0x018D 02/21/2023 21:03:51 System NTP update successful. 0x004A 02/20/2023 21:23:02 Device UPS: Self-Test passed. 0x01D2 02/20/2023 21:22:42 Device UPS: Self-Test started by automatic timer. 0x0137 02/10/2023 15:57:48 Device UPS: Battery life exceeded. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018C 02/07/2023 21:03:57 System NTP update successful. 0x004A 02/06/2023 21:23:28 Device UPS: Self-Test passed. 0x01D2 02/06/2023 21:23:07 Device UPS: Self-Test started by automatic timer. 0x0137 02/05/2023 22:16:22 Device UPS: Battery near end of life cleared. 0x018B 01/25/2023 16:37:33 Device UPS: Battery near end of life. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018A 01/24/2023 21:03:45 System NTP update successful. 0x004A 01/23/2023 21:24:24 Device UPS: Self-Test passed. 0x01D2 01/23/2023 21:24:02 Device UPS: Self-Test started by front panel. 0x0137 01/15/2023 14:19:14 System Web user 'apc' logged out from 10.60.250.21. 0x001F 01/15/2023 14:16:14 apc Web user 'apc' logged in from 10.60.250.21. 0x0015 01/11/2023 21:22:05 Device UPS: Self-Test passed. 0x01D2 01/11/2023 21:21:44 Device UPS: Self-Test started by automatic timer. 0x0137 01/11/2023 16:37:54 Device UPS: Battery near end of life cleared. 0x018B 01/10/2023 21:03:31 System NTP update successful. 0x004A 12/28/2022 21:22:30 Device UPS: Self-Test passed. 0x01D2 12/28/2022 21:22:09 Device UPS: Self-Test started by automatic timer. 0x0137 12/27/2022 21:03:22 System NTP update successful. 0x004A 12/14/2022 21:22:55 Device UPS: Self-Test passed. 0x01D2 12/14/2022 21:22:34 Device UPS: Self-Test started by front panel. 0x0137 12/13/2022 21:03:10 System NTP update successful. 0x004A 12/08/2022 16:55:55 Device UPS: Battery near end of life. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018A 12/05/2022 01:36:17 Device UPS: No longer on battery power. 0x010A 12/05/2022 01:36:16 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 12/05/2022 01:36:02 Device UPS: Bypass not in range ; distorted waveform. 0x020F 12/05/2022 01:36:01 Device UPS: On battery power in response to rapid change of input. 0x0109 12/05/2022 01:15:41 Device UPS: No longer on battery power. 0x010A 12/05/2022 01:15:41 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 12/05/2022 01:15:29 Device UPS: Bypass not in range ; distorted waveform. 0x020F 12/05/2022 01:15:29 Device UPS: On battery power in response to rapid change of input. 0x0109 12/03/2022 21:45:17 Device UPS: Self-Test passed. 0x01D2 12/03/2022 21:44:56 Device UPS: Self-Test started by automatic timer. 0x0137 11/29/2022 21:02:21 System NTP update successful. 0x004A 11/24/2022 16:56:19 Device UPS: Battery near end of life cleared. 0x018B 11/19/2022 21:45:42 Device UPS: Self-Test passed. 0x01D2 11/19/2022 21:45:21 Device UPS: Self-Test started by automatic timer. 0x0137 11/19/2022 21:13:40 Device UPS: Battery near end of life. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018A 11/15/2022 21:01:49 System NTP update successful. 0x004A 11/05/2022 21:46:23 Device UPS: Self-Test passed. 0x01D2 11/05/2022 21:46:02 Device UPS: Self-Test started by front panel. 0x0137 11/05/2022 21:14:26 Device UPS: Self-Test passed. 0x01D2 11/05/2022 21:14:05 Device UPS: Self-Test started by front panel. 0x0137 11/05/2022 21:14:03 Device UPS: Battery near end of life cleared. 0x018B 11/01/2022 21:01:56 System NTP update successful. 0x004A 10/27/2022 20:16:26 Device UPS: Self-Test passed. 0x01D2 10/27/2022 20:16:05 Device UPS: Self-Test started by automatic timer. 0x0137 10/18/2022 21:02:00 System NTP update successful. 0x004A 10/13/2022 20:16:51 Device UPS: Self-Test passed. 0x01D2 10/13/2022 20:16:30 Device UPS: Self-Test started by automatic timer. 0x0137 10/11/2022 20:09:35 Device UPS: Battery near end of life. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018A 10/04/2022 21:02:02 System NTP update successful. 0x004A 09/29/2022 20:17:15 Device UPS: Self-Test passed. 0x01D2 09/29/2022 20:16:55 Device UPS: Self-Test started by automatic timer. 0x0137 09/27/2022 20:10:00 Device UPS: Battery near end of life cleared. 0x018B 09/20/2022 21:01:31 System NTP update successful. 0x004A 09/15/2022 20:17:41 Device UPS: Self-Test passed. 0x01D2 09/15/2022 20:17:20 Device UPS: Self-Test started by automatic timer. 0x0137 09/15/2022 20:17:20 Device UPS: Battery near end of life. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018A 09/06/2022 21:01:02 System NTP update successful. 0x004A 09/01/2022 20:18:09 Device UPS: Self-Test passed. 0x01D2 09/01/2022 20:17:48 Device UPS: Self-Test started by front panel. 0x0137 09/01/2022 20:17:46 Device UPS: Battery near end of life cleared. 0x018B 08/25/2022 14:41:18 apc Web user 'apc' logged out from 10.60.250.147. 0x001F 08/25/2022 14:40:47 apc Web user 'apc' logged in from 10.60.250.147. 0x0015 08/25/2022 14:40:40 apc Web user 'apc' logged out from 10.60.250.147. 0x001F 08/25/2022 14:40:16 apc Web user 'apc' logged in from 10.60.250.147. 0x0015 08/23/2022 21:00:33 System NTP update successful. 0x004A 08/21/2022 21:30:30 Device UPS: Self-Test passed. 0x01D2 08/21/2022 21:30:09 Device UPS: Self-Test started by automatic timer. 0x0137 08/21/2022 18:00:20 Device UPS: Battery near end of life. Order replacement battery, APCRBC140, for the internal pack, cartridge 1. 0x018A 08/09/2022 20:59:46 System NTP update successful. 0x004A 08/07/2022 21:30:54 Device UPS: Self-Test passed. 0x01D2 08/07/2022 21:30:33 Device UPS: Self-Test started by automatic timer. 0x0137 07/26/2022 20:58:56 System NTP update successful. 0x004A 07/24/2022 21:31:47 Device UPS: Self-Test passed. 0x01D2 07/24/2022 21:31:26 Device UPS: Self-Test started by front panel. 0x0137 07/13/2022 03:42:32 Device UPS: Self-Test passed. 0x01D2 07/13/2022 03:42:11 Device UPS: Self-Test started by automatic timer. 0x0137 07/12/2022 20:59:02 System NTP update successful. 0x004A 07/09/2022 00:29:02 Device UPS: No longer on battery power. 0x010A 07/09/2022 00:29:02 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 07/08/2022 23:23:20 Device UPS: On battery power in response to low input voltage. 0x0109 07/08/2022 23:23:20 Device UPS: Bypass not in range ; distorted waveform. 0x020F 06/29/2022 03:42:56 Device UPS: Self-Test passed. 0x01D2 06/29/2022 03:42:35 Device UPS: Self-Test started by automatic timer. 0x0137 06/28/2022 20:59:08 System NTP update successful. 0x004A 06/15/2022 03:43:21 Device UPS: Self-Test passed. 0x01D2 06/15/2022 03:43:01 Device UPS: Self-Test started by automatic timer. 0x0137 06/14/2022 20:59:18 System NTP update successful. 0x004A 06/10/2022 00:50:42 Device UPS: No longer on battery power. 0x010A 06/10/2022 00:50:42 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 06/10/2022 00:50:22 Device UPS: On battery power in response to distorted input. 0x0109 06/10/2022 00:50:22 Device UPS: Bypass not in range ; distorted waveform. 0x020F 06/09/2022 23:49:40 Device UPS: No longer on battery power. 0x010A 06/09/2022 23:49:39 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 06/09/2022 23:49:17 Device UPS: Bypass not in range ; distorted waveform. 0x020F 06/09/2022 23:49:16 Device UPS: On battery power in response to low input voltage. 0x0109 06/01/2022 03:44:08 Device UPS: Self-Test passed. 0x01D2 06/01/2022 03:43:48 Device UPS: Self-Test started by automatic timer. 0x0137 06/01/2022 03:43:46 Device UPS: The power for switched outlet group 2, Outlet Group 2, is now turned on. 0x0134 06/01/2022 03:43:46 Device UPS: The power for switched outlet group 1, Outlet Group 1, is now turned on. 0x0134 06/01/2022 03:43:46 Device UPS: The output power is now turned on. 0x0113 06/01/2022 03:43:46 Device UPS: Switched outlet group 2, Outlet Group 2, has been commanded to turn on, sequenced. 0x0174 06/01/2022 03:43:46 Device UPS: Switched outlet group 1, Outlet Group 1, has been commanded to turn on, sequenced. 0x0174 05/31/2022 23:10:57 Device UPS: The power for switched outlet group 2, Outlet Group 2, is now turned off. 0x0135 05/31/2022 23:10:57 Device UPS: The power for switched outlet group 1, Outlet Group 1, is now turned off. 0x0135 05/31/2022 23:10:57 Device UPS: Switched outlet group 2, Outlet Group 2, has been commanded to turn off, sequenced. 0x0174 05/31/2022 23:10:57 Device UPS: Switched outlet group 1, Outlet Group 1, has been commanded to turn off, sequenced. 0x0174 05/31/2022 23:10:57 Device UPS: The output power is turned off. 0x0114 05/31/2022 23:10:57 Device UPS: The graceful shutdown period has ended. 0x014F 05/31/2022 20:59:26 System NTP update successful. 0x004A 05/23/2022 00:02:32 Device UPS: No longer on battery power. 0x010A 05/23/2022 00:02:31 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/23/2022 00:02:13 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/23/2022 00:02:13 Device UPS: On battery power in response to distorted input. 0x0109 05/22/2022 23:38:38 Device UPS: No longer on battery power. 0x010A 05/22/2022 23:38:38 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/22/2022 23:38:21 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/22/2022 23:38:21 Device UPS: On battery power in response to distorted input. 0x0109 05/22/2022 07:32:56 Device UPS: Self-Test passed. 0x01D2 05/22/2022 07:32:35 Device UPS: Self-Test started by front panel. 0x0137 05/22/2022 05:03:04 Device UPS: No longer on battery power. 0x010A 05/22/2022 05:03:03 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/22/2022 05:02:59 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/22/2022 05:02:59 Device UPS: On battery power in response to rapid change of input. 0x0109 05/21/2022 23:29:02 Device UPS: No longer on battery power. 0x010A 05/21/2022 23:29:02 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/21/2022 23:28:56 Device UPS: On battery power in response to distorted input. 0x0109 05/21/2022 23:28:56 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/20/2022 20:39:08 Device UPS: Self-Test passed. 0x01D2 05/20/2022 20:38:47 Device UPS: Self-Test started by front panel. 0x0137 05/17/2022 20:59:34 System NTP update successful. 0x004A 05/15/2022 03:13:15 Device UPS: No longer on battery power. 0x010A 05/15/2022 03:13:15 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/15/2022 03:13:09 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/15/2022 03:13:09 Device UPS: On battery power in response to distorted input. 0x0109 05/15/2022 01:08:10 Device UPS: No longer on battery power. 0x010A 05/15/2022 01:08:09 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 05/15/2022 01:08:02 Device UPS: Bypass not in range ; distorted waveform. 0x020F 05/15/2022 01:08:02 Device UPS: On battery power in response to distorted input. 0x0109 05/08/2022 21:32:31 Device UPS: Self-Test passed. 0x01D2 05/08/2022 21:32:10 Device UPS: Self-Test started by automatic timer. 0x0137 05/03/2022 20:59:42 System NTP update successful. 0x004A 04/24/2022 21:32:51 Device UPS: Self-Test passed. 0x01D2 04/24/2022 21:32:30 Device UPS: Self-Test started by front panel. 0x0137 04/22/2022 02:13:11 Device UPS: No longer on battery power. 0x010A 04/22/2022 02:13:10 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 04/22/2022 02:12:34 Device UPS: Bypass not in range ; distorted waveform. 0x020F 04/22/2022 02:12:34 Device UPS: On battery power in response to distorted input. 0x0109 04/21/2022 23:09:42 Device UPS: No longer on battery power. 0x010A 04/21/2022 23:09:41 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 04/21/2022 23:09:29 Device UPS: Bypass not in range ; distorted waveform. 0x020F 04/21/2022 23:09:29 Device UPS: On battery power in response to distorted input. 0x0109 04/21/2022 04:13:25 Device UPS: No longer on battery power. 0x010A 04/21/2022 04:13:25 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 04/21/2022 04:13:11 Device UPS: On battery power in response to distorted input. 0x0109 04/21/2022 04:13:11 Device UPS: Bypass not in range ; distorted waveform. 0x020F 04/20/2022 23:16:33 Device UPS: No longer on battery power. 0x010A 04/20/2022 23:16:33 Device UPS: An input voltage or frequency problem no longer prevents switching to bypass mode. 0x0210 04/20/2022 23:16:22 Device UPS: Bypass not in range ; distorted waveform. 0x020F 04/20/2022 23:16:22 Device UPS: On battery power in response to distorted input. 0x0109 04/19/2022 20:59:51 System NTP update successful. 0x004A 04/15/2022 00:50:59 Device UPS: Self-Test passed. 0x01D2 04/15/2022 00:50:38 Device UPS: Self-Test started by automatic timer. 0x0137 04/15/2022 00:50:37 Device UPS: The power for switched outlet group 2, Outlet Group 2, is now turned on. 0x0134 04/15/2022 00:50:37 Device UPS: The power for switched outlet group 1, Outlet Group 1, is now turned on. 0x0134 04/15/2022 00:50:37 Device UPS: The output power is now turned on. 0x0113 04/15/2022 00:50:36 Device UPS: Switched outlet group 2, Outlet Group 2, has been commanded to turn on, sequenced. 0x0174 04/15/2022 00:50:36 Device UPS: Switched outlet group 1, Outlet Group 1, has been commanded to turn on, sequenced. 0x0174 04/14/2022 23:01:28 Device UPS: The power for switched outlet group 2, Outlet Group 2, is now turned off. 0x0135 04/14/2022 23:01:28 Device UPS: The power for switched outlet group 1, Outlet Group 1, is now turned off. 0x0135 04/14/2022 23:01:28 Device UPS: The output power is turned off. 0x0114 04/14/2022 23:01:28 Device UPS: The graceful shutdown period has ended. 0x014F 04/14/2022 23:01:27 Device UPS: Switched outlet group 2, Outlet Group 2, has been commanded to turn off, sequenced. 0x0174 04/14/2022 23:01:27 Device UPS: Switched outlet group 1, Outlet Group 1, has been commanded to turn off, sequenced. 0x0174 04/14/2022 04:01:18 Device UPS: Self-Test passed. 0x01D2 04/14/2022 04:00:58 Device UPS: Self-Test started by automatic timer. 0x0137 04/14/2022 04:00:57 Device UPS: The power for switched outlet group 2, Outlet Group 2, is now turned on. 0x0134 04/14/2022 04:00:57 Device UPS: The power for switched outlet group 1, Outlet Group 1, is now turned on. 0x0134 04/14/2022 04:00:56 Device UPS: The output power is now turned on. 0x0113 04/14/2022 04:00:56 Device UPS: Switched outlet group 2, Outlet Group 2, has been commanded to turn on, sequenced. 0x0174 04/14/2022 04:00:56 Device UPS: Switched outlet group 1, Outlet Group 1, has been commanded to turn on, sequenced. 0x0174 04/14/2022 01:46:00 Device UPS: The power for switched outlet group 2, Outlet Group 2, is now turned off. 0x0135 04/14/2022 01:46:00 Device UPS: The power for switched outlet group 1, Outlet Group 1, is now turned off. 0x0135 04/14/2022 01:46:00 Device UPS: Switched outlet group 2, Outlet Group 2, has been commanded to turn off, sequenced. 0x0174 04/14/2022 01:46:00 Device UPS: Switched outlet group 1, Outlet Group 1, has been commanded to turn off, sequenced. 0x0174 04/14/2022 01:46:00 Device UPS: The output power is turned off. 0x0114 04/14/2022 01:46:00 Device UPS: The graceful shutdown period has ended. 0x014F 04/11/2022 20:15:41 Device UPS: Self-Test passed. 0x01D2 04/11/2022 20:15:20 Device UPS: Self-Test started by front panel. 0x0137 04/07/2022 00:06:21 Device UPS: Self-Test passed. 0x01D2