Professional Documents
Culture Documents
Smart Code Program
Smart Code Program
Smart Code Program
A
M M
F F
B
Installation and User Guide Fasteners
K L 03809 SL03031011 R
Strike Keys
N Q
Required tools
C E
P S
Weiser
4 AA Batteries Ruler Phillips head screwdriver
USA: 1-800-677-5625
Adapter Mounting SmartKey 48654 49191 64109
Additional Tools (depending on application) Canada: 1-800-501-9471 Ring Plate Tool T
www.weiserlock.com U V
Hammer Wood block D G H
If drilling a new door, use the supplied template and the complete
door drilling instructions available at www.weiserlock.com/doorprep.
A Measure to confirm that the hole in B Measure to confirm that the backset is C Measure to confirm that the hole in D Measure to confirm that the door is
the door is either 2-1/8" (54 mm) or either 2-3/8" or 2-3/4" (60 or 70 mm). the door edge is 1" (25 mm). between 1-3/8" and 2" (35 mm and
1-1/2" (38 mm). 51 mm) thick.
ba
2-3/8" or 2-3/4" ck
se
60 or 70 mm t 1-3/8" – 2"
2-1/8" 35 – 51 mm
54 mm
1"
or 25 mm
1-1/2"
38 mm
actual
2 Install the latch and strike size
N P Q R
A Is the door edge chiseled? B Hold the latch in front of the door hole, with the latch D Which latch are you installing?
face flush against the door edge.
A B A
C Is the D-shaped hole centered in the door hole?
YES NO
N or P
(2x) wood
block
or
Longer screws
install closest to
the door jamb.
B
S (2x) C
Q or R (2x) door frame
1/4
actual
3 Install the exterior keypad size
T
A What is the diameter of the hole in the door? C Install exterior keypad and mounting plate.
2-1/8" 1-1/2"
G
54 mm 38 mm F
D c d
Keep parallel to
edge of door. E
Insert key and
test latch. If latch
does not extend or
retract smoothly,
B Locate screws for step 3C and keep them within reach. T adjust screws (T).
Remove key when
finished and make
Tighten T (2x) sure the latch bolt
T screws evenly. is fully extended.
actual
4 Install the interior assembly size
U
A Remove battery cover and battery pack from interior assembly. B Install interior assembly onto mounting plate.
a b a L b
align
L
c d c d
K
Make sure
turnpiece shaft is
rotated as shown.
Do not install U
batteries (2x)
until step 5.
L
L bottom
hole
This step will teach your lock the orientation of your door and is crucial to lock operation.
A Install 4 AA batteries in battery pack. B Press and HOLD the Lock button C Did the latch bolt retract and extend on its own
while installing battery pack. when the battery pack was installed?
Hold button until the latch bolt
starts moving on its own.
Note: Latch
bolt will only
K retract half way.
YES NO
or
Ensure correct polarity. Door handing process Remove battery pack,
For best results, use was successful! Proceed wait 15 seconds, then
new, non-rechargeable to next step after latch attempt the process again.
Alkaline batteries only. bolt stops moving.
2/4
6 Add user codes (16 max)
Programming Timeout
During programming, if no button is pressed for five seconds, the system will time out (indicated by
three beeps and a red flashing keypad), and you will need to restart the procedure.
A Make sure the door is open. Press B Enter user code. A total of 16 user C Press Lock button once.
the Program button once. codes may be programmed.
One green flash with one beep Three red flashes with three beeps
or
green red
1x 3x
*Beeping sound will only be heard if switch #3 (on the lock interior) is in the on positon. See “Switches and Status LED Colors” on page 4.
Mastercode
For enhanced security, a mastercode may be used when adding and deleting user codes. For more information about the mastercode,
download the Programming and Troubleshooting Guide on the SmartCode 10 page at www.weiserlock.com.
actual
8 Re-key the lock (if needed) and install the battery cover size
V
a b c a b
K K
IMPORTANT: Re-key the lock Reinstall
Remove battery to work with your battery
M
pack before existing key. See pack.
re-keying. the supplied
SmartKey Re-key V (3x)
instructions for
more information.
H
3/4
Reference Guide
Note: When the cover is removed, *Beeping sound will only be heard if switch #3 is on.
the turnpiece shaft can be used to
manually lock and unlock the door.
Switches
On Off
Status
LED
1 Keep door open. 2 Press Lock 3 Enter user code 4 Press Lock 1 Remove 2 Press and HOLD the Program
Press Program button once. to be deleted. button once. battery pack. button while reinserting
button once. the battery pack.
Keep holding the button for 30
seconds until the lock beeps
and the status LED flashes red.
Status
LED
5 Re-enter user code. 6 Press Lock 3 Press the Program button 4 Perform the door handing process again
If unsuccessful Test code
button once. once more. In 20 seconds, to teach the lock the orientation of the
Make sure to enter While the door is when the LED flashes green door and add user codes to your lock.
the same valid code open, test the user and you hear one beep, the
in steps 3 and 5. code to make sure lock has been reset.
it no longer unlocks
the door.
If no button is pressed for five seconds, the system will time out, and
you will need to restart the procedure.
Important Safeguards
CAUTION: Prevent unauthorized entry. Since anyone with access to the back panel
can change the user codes, you must restrict access to the back panel and routinely
check the user codes to ensure they have not been altered without your knowledge.
The use of a mastercode can help protect your system’s settings.
WARNING: This Manufacturer advises that no lock can provide complete security
by itself. This lock may be defeated by forcible or technical means, or evaded by
entry elsewhere on the property. No lock can substitute for caution, awareness of
your environment, and common sense. Builder’s hardware is available in multiple
performance grades to suit the application. In order to enhance security and reduce
risk, you should consult a qualified locksmith or other security professional.