Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

HONEYWELL

AIRPORT TRAFFIC
SENSOR SYSTEM
Using highly reliable Airport Traffic
Sensors for aircraft and vehicle
detection in runway/taxiway areas

HIGHLIGHTS
• Up to 4000 m distance between sensor and ISA-3DET evaluation unit
• Detection of classification, direction and velocity (“CVD configuration”)
• Proved installation of more than 1.300 sensors on 16 airports world-wide

FEATURES AND BENEFITS

MAIN FEATURES DESIGN FUNCTIONS


Detection Sensitive Area (DSA) Each ISA-3DET evaluation unit Detection based on the change of low
formed by outdoor copper cable for up to 4 individual sensors frequency magnetic field gen-erated by
Standard communication cable microcomputer-based signal evaluation
Interface to control and monitoring
for signal transmission system available: serial (INTERBUS) or Simple cable in airfield activated by
Redundant communication to parallel (via opto coupling dry contacts) remote enhanced micro-processor
Control and Monitoring System operation provides a high sensitivity
19” mounting rack incl. power supply
and redundant power supplies and automatic calibration
and over voltage protection for:
Well protected indoor electronic 5 ISA-3DET with serial interface Over Voltage Protection (OVP) available
for signal evaluation
8 ISA-3DET with parallel interface for ISA-3DET evaluation unit
Reaction time and error
Indication of engagement of Permanent self tests and
detection less than 300 ms
areas and different errors like automatic system calibration
Continuous measurement and open circuit or short circuit
fault handling for each sensor
Service plug (RS-232) at front panel of
ISA-3DET evaluation unit to configure
different sensor arrangements
TECHNICAL DATA
Arrangement of Detection
SENSOR
sensitive area (DSA)
SENSOR CABLE TYPE Oelflex 400P, 4 x 1,5 (11 mm Ø)
SENSOR DIMENSION Minimum: 3m x 5m
Maximum: 4.5m x 30m
TELEPHONE CABLE
TELEPHONE CABLE TYPE Type: A- 2YF(L)2Y
telephone cable (x times two pair core 0,8 mm Ø)
CABLE PARAMETERS Resistance R = 36 mΩ/m
Inductance L = 348 nH/m
Capacitance C = 86 pF/m
One DSA for Taxiway up to 32m
Conductance G = 0 nS/m
MAXIMUM LENGTH Up to 4000 m between sensor and ISA-3DET evaluation unit
OVER VOLTAGE PROTECTION (OVP)
TYPE COMTRAP CTM 2x1- 12V DC Nr. 2838584
Manufacturer: Phoenix Contact GmbH
SURGE PROTECTION PARAMETERS Resistance R = 9600 mΩ
Inductance L = 0 µH
Capacitance C = 0 pF
ISA-3DET EVALUATION UNIT
MECHANICAL DATA Eurocard: 160mm x 100mm
PARALLEL INTERFACE Up to 8 ISA-3DET evaluation units per subrack Two DSA for Taxiway/Runway up to 65m
(Opto coupling dry contacts)
SERIAL INTERFACE (INTERBUS) Up to 5 ISA-3DET evaluation units per subrack
AMBIENT DATA Operating Temperature: 0° C … +40° C
Storage Temperature: -40° C … +80° C
Humidity: 80% without condenstation
OPTOCOUPLER FEATURES HCPL-181-06BE (Manufacturer: Avago Technologies)
Isolation Voltage, Viso = 3750 Vrms
Collector-Emitter Voltage, VCEO = 80 V

cvd configuration, 2 DSA for taxiway up to 32m

For more information


https://buildings.honeywell.com/airports

Honeywell Building Technologies


Americas
1985 Douglas Drive
North Golden Valley
MN 55422-3992
Tel: 1800 345 6770 ext. 612

Europe & North Africa


Broedermannsweg 1 cvd configuration, 4 DSA for taxiway/runway
22453, Hamburg up to 65m
Germany
Phone: +49 40 61144-0
Tel: 971 4 4540 685

Middle East, Indian Subcontinent


& Central Africa
Emaar Business Park Building 2, Level 2,
Office 201, P.O. Box 232363
Sheikh Zayed Road
Dubai, UAE Subject to alterations.

Tel: 971 4 4540 685 HAB-45000634-TDE | 08/20


www.honeywell.com © 2020 Honeywell International Inc.

You might also like