Building wiring 4 DALI bus 26
Electrical installation - lighting 5 Serial data communication wiring 27
Electrical installation - roller shutters 6 Star data communication wiring 28
Electrical installation - heating 7 Mixed data communication wiring 29
Electrical installation - touch panels and switches 8 Bus power supply 30
Electrical installation - sensors 9 DALI bus - requirements 31
Electrical installation - water valves 10 Number of ballasts 32
2
Table of contents
Multisensor 48
Placement - reading of sensor measurements 49
Radiation characteristics of IR emitter and operation range 50
Modules protection 58
Residual current circuit breakers and overcurrent circuit
breakers for Relay module 59
Residual current circuit breakers and overcurrent circuit
breakers for I/O 8/8 module 60
Residual current circuit breakers and overcurrent circuit
breakers for Roller Shutter module 61
Residual current circuit breakers and overcurrent circuit
breakers for Dimmer MOSFET module 62
3
Building wiring
4
Building wiring
3x1,5 mm2
N
L
4x1,5 mm2
N
L
2x0,75 mm2
N
L
N
L
Humidity sensor
Door/window 0-10V
sensor
Water leak
sensor
N
L
2x0,75 mm2
N
L
11
Grenton TF-Bus
VCC B GND
A GND
GND
B’
B’ VCC
A’ B
A A’ VCC
Bus length
Forbidden branching
Forbidden branch
18
Wireless protocols
Z-Wave
GRENTON ROLLER
SHUTTER Z-Wave
RSH-202-Z-01
G I1 I2 1W
GRENTON RELAY N L 01 02
X2 Z-Wave
REL-203-Z-01
G I1 I2 1W
N L 01 02
GRENTON ROLLER
SHUTTER Z-Wave
RSH-202-Z-01
G I1 I2 1W
N L 01 02 GRENTON RELAY
X2 Z-Wave
REL-203-Z-01
G I1 I2 1W
N L 01 02
22
1-Wire bus
max. 16 sensors
GND
GND
GND
GND
GND
GND
VDD
VDD
VDD
VDD
VDD
VDD
VDD
DQ
DQ
DQ
DQ
DQ
DQ
DQ
back to Table of contents 23
1-Wire bus
GND
GND
VDD
VDD
VDD
DQ
DQ
DQ
GND
GND
GND
GND
VDD
VDD
VDD
VDD
DQ
DQ
DQ
DQ
back to Table of contents 24
1-Wire bus
GND
GND
GND
VDD
VDD
VDD
VDD
DQ
DQ
DQ
DQ
the max. length of bus is 20 m the max. length of bus is 20 m
26
DALI bus
GND VCC
DALI
Power Supply
Number of ballasts
max. 64 ballasts per 1 DALI Controller max. 64 ballasts per 1 DALI Controller
33
System communication
Mobile devices
Telecommunications cables
37
System power supply
100 mA 100 mA 67 mA 20 mA 75 mA 20 mA 30 mA 20 mA
Max. summary power consumption + 30% buffer Optimal parameters of the power supply unit for this example
Additional
bus supply
N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3
ROLLER SHUTTER ROLLER SHUTTER ROLLER SHUTTER ROLLER SHUTTER ROLLER SHUTTER
RSH-203-D-01 RSH-203-D-01 RSH-203-D-01 RSH-203-D-01 RSH-203-D-01
N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3
ROLLER SHUTTER ROLLER SHUTTER ROLLER SHUTTER ROLLER SHUTTER ROLLER SHUTTER
RSH-203-D-01 RSH-203-D-01 RSH-203-D-01 RSH-203-D-01 RSH-203-D-01
N L V1 V2 C1 V2 D2 C2 V3 D3 C3 N L V1 V2 C1 V2 D2 C2 V3 D3 C3
Alarm B Alarm A
V out V in
+ - - - B+ A+
44
Bus termination
Bus termination
GRENTON TF-Bus Cable
Termination jumper
2.54 mm Resistor 120 Ω
Termination
Termination
TF- Bus
TF- Bus
48
Multisensor
min. 20cm
150-200 cm
0o
10o 10o
20o 20o
30o 30o
40o 40o
50o 50o
l=6 m
60o 60o
70o 70o
80o 80o
90o 90o
100
100
30
60
50
80
90
40
20
70
60
30
90
50
80
40
20
10
70
10
0
0
51
LED strips control
V+ V+
R R
G G
B B
W W
W W
B B
G G
R R
V+ V+
V+ V+
W W
c c
V+ V+
W W
c c
c c
W W
V+ V+
c c
W W
V+ V+
V+ V+
W W
V+ V+
W W
V+ V+
W W
V+ V+
W W
V+ V+
W W
V+ V+
W W
V+ V+
W W
V+ V+
W W
58
Modules protection
N
L
N L
N L
N
L
N L
N L
N
L
N L
N L
N
L
N L
N L