FODDER AND PASTURE DEVELOPMENT

Item Description Unit Qty Rate (RM) Amount (RM)

PIPE CULVERT

Precast concrete pipe culvert Class 'X' complete with collars jointed and pointed
in cement and sand (1:3) laid to falls in trench and including pipe bedding,
hardcore, lean concrete, mass concrete concrete surround with reinforcement,
and all excavation and formworks as per drawing no.
ECER/PI/JDV/RMR/C&S/TD/RD/006/00
BQ.6/4/1/B 900mm Diameter precast concrete; exceeding 1.00m not exceeding 1.50m deep M 263

Reinforced concrete headwall, wingwall, base slab including excavation work,


formworks, concrete, reinforcement, lean concrete and shoring for as per
drawing no. ECER/PI/JDV/RMR/C&S/TD/RD/006/00:-
BQ.6/4/1/C 900mm Diameter precast concrete NO 32

BOX CULVERT
Precast box concrete complete with collars jointed and pointed in cement and
sand (1:3) laid to falls in trench and including sand bedding, hardcore, lean
concrete, mass concrete concrete surround with reinforcement, and all
excavation and formworks as per drawing no.
ECER/PI/JDV/RMR/C&S/TD/FR/005/00
BQ.6/4/2/A 3000mm x 3000mm precast concrete box culvert; exceeding 1.00m not exceeding M 36
1.50m deep

Reinforced concrete headwall, wingwall, base slab including excavation work,


formworks, concrete, reinforcement, lean concrete and shoring for as per
BQ.6/4/2/B drawing
3000mm no. ECER/PI/JDV/RMR/C&S/TD/FR/004/00:-
x 3000mm precast concrete box culvert NO 8

Pipe Culvert
Precast concrete pipe culvert Class 'X' complete with collars jointed and pointed
in cement and sand (1:3) laid to falls in trench and including pipe bedding,
hardcore, lean concrete, mass concrete concrete surround with reinforcement,
and all excavation and formworks as per drawing no.
ECER/PI/JDV/RMR/C&S/TD/RD/006/00
BQ.6/5/3/C 900mm Diameter precast concrete; exceeding 1.00m not exceeding 1.50m deep M 105
BQ.6/5/3/D 900mm Diameter precast concrete NO 16

Box Culvert
Precast box concrete complete with collars jointed and pointed in cement and
sand (1:3) laid to falls in trench and including sand bedding, hardcore, lean
concrete, mass concrete concrete surround with reinforcement, and all
excavation and formworks as per drawing
no.ECER/PI/JDV/RMR/C&S/TD/FR/005/00
BQ.6/5/4/A 1500mm x 1500mm precast concrete box culvert; exceeding 1.00m not exceeding M 27
1.50m deep

Reinforced concrete headwall, wingwall, base slab including excavation work,


formworks, concrete, reinforcement, lean concrete and shoring for as per
drawing no. ECER/PI/JDV/RMR/C&S/TD/FR/004/00:-
BQ.6/5/4/B 1500mm x 1500mm precast concrete box culvert NO 4