Large Flow User Manual
Large Flow User Manual
2 Safety notice......................................................................................................... 5
3 Product introduction.............................................................................................7
4 Using condition..................................................................................................... 8
5 Scope of application:........................................................................................... 8
6 Technical Parameter......................................................................................... 8
8 Operation steps.................................................................................................. 11
9 Maintenance........................................................................................................12
12 Quality Warrant................................................................................................ 15
13 Contact us......................................................................................................... 15
3
1 Foreword
Thank you for purchasing our products, hoping you will be satisfied with
our products.
To ensure your efficient use of the machine, please have a close read of
Maybe, there are some pictures, which are different from what you have
4
2 Safety notice
Please note the following special statements,used throughout this manual,and their
significance:
Note:Explanatory information.
:The Manufacturer
Before Installation
Placement
concentrator on a surface such as bed or couch, where the concentrator may tip or fall.
Fire Warning
5
WARNING:Textiles and other materials that normally would not easily burn, can ignite
WARNING:A spontaneous and violent ignition may occur if oil, grease or greasy
substances come in contact with oxygen under pressure. ALWAYS keep these substances
away from the oxygen concentrator.
Maintenance
ATTENTION:Before cleaning the dust on the net of oxygen concentrator, the plug must
ATTENTION:The filter cotton and filter are the items needed to clean, among which
external filter cotton should be cleaned every 200 hours, and internal filter should be
cleaned every 900 hours.
WARNING: DO not reach for a concentrator that has fallen into water. UNPLUG IT
IMMEDIATELY.
ATTENTION: ALWAYS supervise closely when this product is used near children or
ATTENTION: In using the machine, do not open the front and back cover at all. In case
there are quality problem, do not dismantle it secretly. Any alarm or other abnormal
phenomenon has been found, connect with equipment supplier or factory.
ATTENTION: Ensure the bottom smooth exhaustion during operating, or else the
6
machine will be over-heated.
intermission).
ATTENTION: 5 minutes are needed from oxygen concentrator from warming up to reach
regular function.
ATTENTION: The machine is only for oxygen supply, and the oxygen concentration will
ATTENTION: In case the indicator shows abnormal oxygen, operator should declare to
ATTENTION: Once open the adjust knob for flow in full, but flow meter shows zero, turn
ATTENTION: Do not turn on or off frequently, To restart the machine after turning off, no
less than 5 minutes are necessary (namely, exhaust internal gas of the machine completely,
for if air compressor turns on with pressure, its life will be shortened )
ATTENTION: Turn up the flowmeter switch immediately when power switch is turned on.
3 Product introduction
Oxygen concentrator model adopt pressure swing adsorption principle, which can
separate oxygen, nitrogen and other gas from the air, at constant temperature, as soon as
power is connected, the oxygen that meets Industrial use standards can be separated from
air constantly. The key parts of the generator adopt anti-tiring and anti-aging design.There
is no influence on indoor oxygen percent during the generator operating.
7
4 Using condition
1. Ambient temperature: 10℃-40℃
2. Relative humidity: 30%-85%
3. Air pressure: 700 hPa-1060 hPa
4. No corrosive gas and strong magnetic field around.
5 Scope of application:
For industry use
Industrial oxygen concentrator is mainly used in industry, agriculture, animal breeding, also
can provide high concentration ,big flow oxygen for related equipment .
6 Technical Parameter
Model JAY-10 JAY-20 JAY-30 JAY-40 JAY-50 JAY-60
Rated power 550 1100 1650 2200 2750 3300
(VA)
Operation AC230±10% 50±1
voltage (V/Hz)
Oxygen flow 0-10 0-20 0-30 0-40 0-50 0-60
(L/min)
Oxygen
concentration 93%±3%
(%)
Outlet pressure
0.04—0.07
(Mpa)
LCD display accumulating timing; timing;
Large LCD Pressure digital(accuracy:0.001MPa);
display accumulating timing(range:0-99999hours);
(optional) present timing(accuracy:1 minute);
8
purity digital;
390*390*730 590*400*1400 760*540*1400 760*540*1400760*540*2000 760*540*2000
Dimension (mm)
Low purity When oxygen purity is 85%, the blue lamp is on,
alarm when oxygen purity is <85% ,red lamp is on, indicating low purity
(Optional)
Dehumidity Pressure:0 Mpa Function: exhaust water
device
9
Figure 3 JAY-30/JAY-40 Figure 4 JAY-50/JAY-60
① ⑦
② ⑧
Figure 5
①Automatic dehydrator ⑦Power switch
③transformer
④adsorption
⑤Solenoid valve
⑥Breaker
10
8 Operation steps
1. Connect the power, put the plug of power line connected with the power AC230V,turn on
the power switch.
230V power
2. Adjust well oxygen output flow according to the request, the maximum scale line of the
flow meter is recommended oxygen absorbing flow (counter clockwise—on, clockwise—off,
JAY-10 adjusted to 10L/min,JAY-20 adjusted to 20L/min
Figure 9
3. Insert the intake end of tube onto the outlet of oxygen concentrator, then use the oxygen
11
to your industry.
4.When finished, turn off the power, if there is discontinuous use, please unplug the power
plug.
Figure 10
5. Oxygen purity alarm(for optional): The oxygen purity will rise to the normal level in five
minutes of operation. When oxygen purity is 85%, the blue lamp is on, when oxygen
purity is <85%, red lamp is on, indicating low purity.
6. In case oxygen generator is connect with power but the whole machine is still in the state
of power off with alarm sound, please check out the connection part of power whether it is
in good connection, or whether there is a power off in external power supply.
9 Maintenance
1、 In the condition of power off, make a clean for the outside body by soft towel with little
detergent, and then wipe it up with dry towel, once or twice per month.
Figure 11
2、 It is a critical step for daily maintenance to clean intake air filter, 200 hours or twice a
month.
12
Detail steps: take off the intake air filter(see the Figure12), clean it with detergent and
clean it out with clean water completely, get ride of extra water and dry up naturally,
finally set back after dry up.
Figure 12
Damage: Do not operate the concentrator without the filters installed, or while filters
Secondary filter
Figure 13
13
Damage: Do not operate the concentrator without the filters installed, or while filters
14
4 Too noisy1. The joint of exhaustion1. Connect the joint well
exhaustion muffler fallen off 2.Have the muffler replaced
2. Exhaustion muffler broken
12 Quality Warrant
Warrant for whole unit:15 months
13 Contact us
LONGFIAN SCITECH CO.,LTD
ADDRESS: 2F&3F, East Section, Building 12, Power valley pioneer park, No.369 Huiyang
street , Baoding, 071051, Hebei ,China
TELEPHONE: +86-312-5909505
FAX: +86-312-5909515
HOMEPAGE:www.longfian.com
15