TII TECHNO TESTING SERVICES PVT. LTD.
(NABL Accredited Testing &L Calibration Facilities)
(PAN : AADCT89420, TIN : 33661667359, Corporate ID No : U74900TN2011PTC 126535 & ST : AADCT89420SD001, GSTIN : 33AADCT894201ZN)
CALIBRATION CERTIFICATE Page 1 of 1
ULR No:CC279621400005861F
CERTIFICATE NO 0313-8-6
(Customer Name & Address: SRF No 2 TH210313-8
M/s.Anpam Engineering, SRF Date 2 13-Mar-2021
9/1, Kumaramangalam Industrial Estate, Calibration Date 2 13-Mar-2021
[Mathur, Pudukkottai. Calibration Due Date _: 13-Mar-2022
Details of Test Instrument:
[Description Digital DC Ammeter Range 70 to 400AT 75mV
Make Lianya Operating Range :
IModet No. Resolution 1A
IMic Serial No. AB/ET/21/106 Mic ID -
ID No/ Tag No A Location =
[Calibrated at 2 Site Condition On Receipt: Good
[Work Instruction No _TSPLIWVETCAL006 Based on Standard TS 1248(Part I to 9):2003/Rev
[Environmental Details 2: 27.8 °C Relative Humidity 49 %RH
Details of Master Used
[Description [Multifunction Calibrator
ISLNo. 1978909,
[Certificate No. 20/99-01,
[Valid up to 3-Sep-2021
ELECTROTECHNICAL CALIBRATION
‘CALIBRATION DATA
DC CURRENT
Range Master Equivalent [Test Reading Mean] Deviation Expanded
A mV A A A A
15.00 80 81 1 0.60
30.00 160 162 2 0.60
400 45.00 240 242 2 0.60
60.00 320 323 3 0.61
75.00 400 403 3 0.62
Note:
Uncertainty of measurement Is at 95.45% confidence level(k=2)
This certificate refers to the measurements for the instrument in as received condition and under
stated environment.
2.Certificate shall not be reproduced except in full without the written approval of Director.
3.*The recalibration interval - as advised by the customer.
4.The standard used for calibration is traceable to Accredited laboratory.
Team Member
Authorised Signatory
D.Anw
| Manager - Calibration
Registered Office : 238/16, Aathanancheri Village, Sriperumpudur(T.K), Padappai - 601 301, Kancheepuram (DT),
‘Tamil Nadu. India, Tel : + 91 4427174801 | e-mail : info@tiiservices.com | Website : wwwstiiservices.com