Perete Exterior 3
Perete Exterior 3
outside
100 5
50 4
3
100 2
490,5
www.ubakus.de
240 1
Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
inside
1 KLB W3 (240 mm) 3 Breather membrane sd=0,05m 5 Clinker bricks (100 mm)
2 ROCKWOOL Varirock 035 (100 mm) 4 Rear ventilated level (50 mm)
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 mm
08 95 Ti au ,25 ,1
41 V O ige ub =0 nd U =0
N z d r e U ta s
DI hu
t
nie 1 4N s au
es
c
n d E V Be nd au siv
h
m t a E n E V ta b s
är Be
s En Bes Neu u Pa
W 0 ,2
EV 2 16 ba =0 ,15
En 20 EV Neu V U . =0
G n
E 20 n U
GE nM aß us 40
20 ESa elm 5 - Ha KfW
G z 5 r
GE e
Ein fW BW -Lit bau
f W u K eG 3 u
K ba ärm Ne
u
Ne EW
*Vergleich mit dem Höchstwert gemäß GEG 2020 für erstmaligen Einbau, Ersatz oder Erneuerung von Außenwänden (Anlage 7, Zeile 1a,1b). Page 1
All statements without guarantee
Temperature profile
Temperature profile
20 Temperature
1 2 3 4 5 Dew point
15
10
1 KLB W3 (240 mm)
Temperature [°C]
-15
-20
0 50 100 150 200 250 300 350 400 450 500
Inside 0°C [mm]
Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
www.ubakus.de Outside
Temperature and dew-point temperature in the component. The dew-point indicates the temperature, at which water vapour
condensates. As long as the temperature of the component is everywhere above the dew-point temperature, no
condensation occurs. If the curves have contact, condensation occurs at the corresponding position.
Page 2
All statements without guarantee
Moisture proofing
For the calculation of the amount of condensation water, the component was exposed to the following constant climate for
90 days: inside: 20°C und 50% Humidity; outside: -15°C und 60% Humidity (Climate according to user input).
This component is free of condensate under the given climate conditions.
Humidity
The temperature of the inside surface is 18,1 °C leading to a relative humidity on the surface of 56%.Mould formation is not
expected under these conditions.
The following figure shows the relative humidity inside the component.
Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
100 Relative humidity (%)
1 2 3 4 5 saturation point
90
80
Relative humidity (%)
Page 3
All statements without guarantee
Heat protection
The following results are properties of the tested component alone and do not make any statement about the heat protection
of the entire room:
Temperature profile
This document has been generated by the U-value calculator on www.ubakus.de. If you are harmed by the free use of these contents, the service provider is only liable in case of
32 4 5
30 1 KLB W3 (240 mm)
Temperature [°C]
Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
16
14
0 50 100 150 200 250 300 350 400 450 500
Inside [mm]
www.ubakus.de Outside
Phase shift* 13,2 h Heat storage capacity (whole component): 132 kJ/m²K
Amplitude attenuation ** 56,8 Thermal capacity of inner layers: 103 kJ/m²K
TAV *** 0,018
* The phase shift is the time in hours after which the temperature peak of the afternoon reaches the component interior.
** The amplitude attenuation describes the attenuation of the temperature wave when passing through the component. A value of 10
means that the temperature on the outside varies 10x stronger than on the inside, e.g. outside 15-35 °C, inside 24-26 °C.
*** The temperature amplitude ratio TAV is the reciprocal of the attenuation: TAV = 1 / amplitude attenuation
Note: The heat protection of a room is influenced by several factors, but essentially by the direct solar radiation through windows and the
total amount of heat storage capacity (including floor, interior walls and furniture). A single component usually has only a very small
influence on the heat protection of the room.