OFFSHORE INFRASTRUCTURES LIMITED

FORMAT FOR WELDERS QUALIFICATION TEST RECORD


FORMAT NO: OIL/EIL/HPCL/B016/3191- F -04 Rev.0
PROJECT NEW TANKAGES ASSOCIATED CIVIL AND PILING WORKS PART - A

Contractor : OFFSHOURE INFRASTRUCTURE.LIMITED Report No:

Consultant : ENGINEERS INDIA LIMITED Date:

Client : HINDUSTAN PETROLEUM CORPORATION LIMITED


Location VISAKHA REFINARY MODERNISATION PROJECT(VRMP) VISAKHAPATNAM A.P

1. NAME OF CONTRAC: Offshore Infrastructures Ltd

2. WELDER NAME :

3. WELDING PROCESS : SMAW CURRENT : DCEP

4. TYPE : MANUAL POSITION :


SHEILDING
5. SHEILDING GAS : NA NA
FLOWRATE :
6. MATRIAL SPECIFICATION : IS 2062 GR-B TO SA240 GR 304

7. DIA & THK. (IF PIPE) JOINT THK.(OTHERWISE) : 300X300X14 MM THK

8. FILLER METAL & MAKE : E - 309L ESAB

9. BATCH NO : PURGING GAS :


NA
10. WPS NO : WPS - PURGING FLOWRATE :
NA
11. WELDER INDENTIFICATION NO : WIRE FEED SPEED :
NA
12. WELDING DATE : TUNGSTAN ELECTRODE :
NA
PASS ELECTRODE CURRENT TRAVEL SPEEDmm/
SR. NO DIA POLARITY VOLT REMARKS
LAYER TYPE (Amp) min

BACK CHIP TO SOUND METAL AND RE WELD

7 FILUP E - 7018 3.15MM DCEP .

8 FINAL - 1 E - 7018 3.15MM DCEP

9 FINAL - 2 E - 7018 3.15MM DCEP

10 FINAL - 3 E - 7018 3.15MM DCEP

13. Root Visual : Preheating : 10 °C


14. Final Visual: Interpass temp. : 250 °C MAX
15. Back chiping :
16. Clearance for RT :

OFFSHORE INFRASTRUCTURES LIMITED TPI A / EIL

Sign:

Name:
Date:
OFFSHORE INFRASTRUCTURES LIMITED

FORMAT FOR WELDERS QUALIFICATION TEST RECORD


FORMAT NO: OIL/EIL/HPCL/B016/3191- F -04 Rev.0

PROJECT NEW TANKAGES ASSOCIATED CIVIL AND PILING WORKS PART - A

Contractor : OFFSHOURE INFRASTRUCTURE.LIMITED Report No:

Consultant : ENGINEERS INDIA LIMITED Date:

Client : HINDUSTAN PETROLEUM CORPORATION LIMITED


Location VISAKHA REFINARY MODERNISATION PROJECT(VRMP) VISAKHAPATNAM A.P

1. NAME OF
: Offshore Infrastructures Ltd
CONTRACTOR :
2. WELDER NAME :

3. WELDING PROCESS : CURRENT :

4. TYPE : MANUAL POSITION :


SHEILDING
5. SHEILDING GAS :
FLOWRATE :
6. MATRIAL SPECIFICATION :

7. DIA & THK. (IF PIPE) JOINT THK.(OTHERWISE) : 300X300X14 MM THK

8. FILLER METAL & MAKE :

9. BATCH NO : PURGING GAS :

10. WPS NO : WPS - 05 PURGING FLOWRATE :

11. WELDER INDENTIFICATION NO : WIRE FEED SPEED :

12. WELDING DATE : TUNGSTAN ELECTRODE :

PASS ELECTRODE CURRENT TRAVEL SPEEDmm/


SR. NO DIA POLARITY VOLT REMARKS
LAYER TYPE (Amp) min

7 .

10

13. Root Visual : Preheating : 10 °C


14. Final Visual: Interpass temp. : 250 °C MAX
15. Back chiping :
16. Clearance for RT :

OFFSHORE INFRASTRUCTURES LIMITED TPI A / EIL

Sign:

Name:
Date: