Specifications

Steam Generator Models: DSMP-5, DSMP-7 and DSMP-10

Features
Light Commercial, intended for Day Spa use, up to 6 hours a day
Limited 1 year parts, 90 day labor warranty where available
AutoDrain included
Proportional Steam
Microprocessor based diagnostics and LED indication
Stainless steel tank construction
Intelligent control communication
UL/CUL Listed

Steam Generator Specification Chart


Product KW *Max. Cu. Ft. Volts/Phase/ Line Dimensions
Number Rating Range Max. Amps Fuse LxWxH
DSMP-5 5 100 240/1/21 30 20.5" x 6" x 15.5"
DSMP-5-208 208/1/24 30

DSMP-7 7.5 250 240/1/31 40 20.5" x 6" x 15.5"


DSMP-7-208 208/1/36 50
DSMP-7-208/3 208/3/21 30

DSMP-10 10 450 240/1/42 50 20.5" x 6" x 15.5"


DSMP-10-208 208/1/48 60
DSMP-10-208/3 208/3/28 40

* Refer to sizing guidelines to accurately determine the proper size generator for the installation.

90°C copper wire is required for generator connection. Installation shall be in accordance with NEC and local
electrical codes.

Required Equipment Installation Notes


TSC Model Control Supplied Warning Plate MUST be permanently installed in
a highly visible location near entrance of the steam room.
Required Electrical Service
For optimum performance, the steam generator should be
Dedicated circuit required: See Specification Chart for proper mounted as close as possible to the steam room. If
electrical requirements needed, the steam pipe may be up to 50’ long.
Product Information Steam Generators should be accessible for service.
Water Supply - ⅜" Compression Fitting, 120 PSI Max Do NOT install near flammable material such as paints,
Steam Outlet - ¾" Brass NPT male thread thinners, gasoline, etc.
Pressure Relief Valve - ¾" NPT female thread Steam generators must NOT be installed outdoors, in
AutoDrain Outlet - ½" Brass NPT female thread moist, humid areas, in areas prone to freezing, or extreme
heat such as an unventilated attic. To do so will void the
Supplied with a 35’ control cable warranty.
Generator with AutoDrain Steamhead to be mounted 12" to 18" above floor or 6"
Weight - 32 lbs. above rim of tub and as far from the seating area as
possible.
Service Access
Minimum: 28" L x 20" W x 22" H
06/17 -1- Pub. No. 1010-A
Specifications

Dimensional Drawing Models: DSMP-5, DSMP-7 and DSMP-10

Mounting Holes

14"
Water Inlet ⅜"
Compression Fitting
Knockouts for
3" max
Control Cables

¾" Steam Outlet

¾" Safety Relief Valve

5½" max

Top of Access
Panel

½” AutoDrain Valve Outlet

Rear Side View Back View Top View

*Add ¼" to the dimension for the louvers

*15" 5½" *6"

Access Panel
2⅞"

2¾"
15½"

INSTALL WITH ARROWS POINTING UP


READ ALL INSTRUCTIONS!
CAUTION: This unit must be installed in a dry, non-freezing indoor
location.
WARNING: Elderly persons, pregnant women, or persons with
12⅛"

heart disease,high blood pressure, diabetes, or not in good health


must not use this device unless directed by a physician. Also SER
NO.
steam bathing should be avoided while intoxicated.
SERVICE BY AUTHORIZED PERSONEL ONLY! NO.
WARNING: Disconnect electric before removing covers.
CAUTION: Supply connection wires must be suitable for SIZE IN.
90°C. Always follow national and local codes.
CAUTION: Hold all fittings securely while connecting pipes. MODEL
Do not install a shut-off valve on the steam outlet.
DANGER: To reduce risk of explosion, do not interconnect SET PSIG ®
multiple steam generator outlets.
THIS GENERATOR IS NOT FOR SPACE HEATING PURPOSES CAP LBS/HR
STEAMBATH GENERATOR
INSTALLER AVEC LES FLÈCHES VERS LE HAUT
LIRE TOUTES LES INSTRUCTIONS! MODEL NO.
ATTENTION: Cet appareil doit être installé à l'intérieur dans un endroit sec à C ® US
l'épreuve du gel.Prévoir un accès pour le service. SERIAL NO.
9⅛"

AVERTISSEMENT: Les personnes âgées, les femmes enceintes, ou les LISTED 995C
personnes souffrant de maladies cardiaques, d'hypertension, de diabète ou n'ayant HEATER LOAD
pas une bonne santé ne devraient pas utiliser ce produit avant d'en parler avec leur VOLTS PH MAX AMPS kW
médecin. Aussi, le bain de vapeur doit être évité en état d'ébriété.
SERVICE PAR PERSONEL AUTORISÉ SEULEMENT!
7⅝"

AVERTISSEMENT: Débranchez l'alimentation électrique avant de retirer le


couvercle. CONTROL CIRCUIT
ATTENTION: les fils de connexion d'alimentation doivent être adaptés à 90°C. VOLTS AMPS 50/60 HZ
Toujours suivre les codes nationaux et locaux.
DANGER: Pour réduire les risques d'explosion, ne pas interconnecter plusieurs SERVICE BY AUTHORIZED PERSONNEL ONLY
A PRODUCT OF STEAMIST CO., RUTHERFORD, NJ
sorties de générateurs de vapeur.
ATTENTION: Tenir tout les accessoires de façon sécuritaire lors de la connection
des tuyaux. Ne pas installer de robinet d'arrêt sur la sortie de la vapeur.
PAS A DES FINS DE CHAUFFAGE 009-1081c

2⅜"
1⅝"

Front Access Front Side View

East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
®
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617

06/17 -2- Pub. No. 1010-A