LIEBERT® CHILLED WATER AIR HANDLER

What’s Cool in the Data Center Thermal Management Innovations

BENEFITS More Efficiency. More Choices. More Experience.

Liebert Custom Air Handling Units Industry-Leading Efficiency. The


Highly Efficient Liebert Chilled Water Air Handler Unit can
Our mission-critical air handlers with deliver higher-than-average temperatures
yy Mechanical PUE less than 1.2 as
Liebert iCOM™ controls deliver efficient, (65-70°F), with industry-leading efficiency
part of a system
reliable and cost-effective management of through the use of for water- or air-side
yy Multiple economization heat in large data centers. economization and high-efficiency EC fans.
options available
We offer the largest selection of air Simplified Maintenance. Maintenance
yy Use of EC fans for lower motor handling solutions, combined with the can be performed easily and quickly, as a
power usage expert guidance to help you select, result of features such as full-coil cleaning
implement and maintain the right access, front access to V-Bank filters and
yy Self-optimizing controls reduce technology to ensure delivered
over-cooling and under-cooling single side-piping.
performance for the lifetime of your
data center. Intelligent Controls. The Liebert Chilled
Greater Protection
Water Air Handling Unit features
yy Less risk of hot spots, through Liebert Chilled Water Air Handler integrated Liebert iCOM unit controls to
advanced controls and rack maximize data center protection, efficiency
inlet sensors
The Liebert Chilled Water Air Handler
and insight. The controls prevent over-
Unit is the industry’s most advanced
cooling and under-cooling through
yy Advanced monitoring and chilled water cooling system, providing
machine-to-machine communications and
event notification you with maximum thermal control in
advanced algorithms. Teamwork modes
your data center.
yy Finely tuned controls for harmonize the multiple cooling units for
more consistent unit supply Economical Deployment. It maintains higher efficiency and protection.
air temperature and minimized conditions at a wide range of return air
swings acrosscomponent ranges Local Service and Support. All of
temperatures and is easy to commission
our solutions are backed by local
and service, helping to boost productivity
Lower Installation & customer engineers with decades of data
and reduce installation and
Maintenance Costs center experience and a network of
maintenance costs.
factory-trained service technicians.
yy Multiple section design
minimizes shipping costs and
speeds installation

yy Full coil cleaning access and


single-side piping

yy Insight for Action

yy Simplified access to real-time


data and trending

yy Quick diagnostics of potential


critical events

1
LIEBERT® CHILLED WATER AIR HANDLER

Liebert® Chilled Water Air Handlers are ensure optimal air flow through the
Key Attributes best used with Liebert iCOM™ unit system while supply air sensors are used
controls, wired or wireless rack sensors, to control the unit cooling capacity.
yy Very efficient with
and a Liebert iCOM™-S system control to Dampers or exhaust fans are
elevated water loop
ensure that the entire data center system automatically adjusted by the Liebert
temperatures and waterside
or airside economizers. is optimized with the other components of iCOM unit control, which also harmonizes
the chilled water system. Liebert iCOM the operation of multiple air handling units
yy Indoor units are control algorithms continuously process to eliminate conflicts in temperature,
typically easy to service readings from the rack inlet sensors to airflow and humidity.
and commission.

Typical Deployments
yy Vertical units along
perimeter or in gallery Advanced Controls For Efficiency, Protection and Insight
discharging into raised floor.

yy Horizontal units in gallery or Return Air


outside the building — may Temperature Filter Gauges
not use raised floor for Sensors
air distribution.
Airflow
Fluid Flow Sensors Measurement
Meters

Supply Air
Fan Power Meters Temperature
Sensors

VertivCo.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA
© 2016 Vertiv Co. All rights reserved. Vertiv, the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been
taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.

SL-19712 (06/15) 2