ACI318-08

Punching
Column Vu Mu xx Mu yy B H T Tp cover d Links
Section
location kN kN.m kN.m mm mm mm mm mm mm no. spacing Vu / f Vn
1 Edge (short) 1000 22 22 400 1000 400 0 30 370 2 - 100 1.02
2 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
3 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
4 Corner 1666 22 22 400 1000 400 0 30 370 2 - 100 1.84
5 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
6 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
7 Interior 1666 22 22 400 1000 400 0 30 370 2 - 100 0.75
8 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
9 Edge (long) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.26
10 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
11 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
12 Corner 1666 22 22 400 1000 400 0 30 370 2 - 100 1.84
13 Edge (long) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.26
14 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
15 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
16 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
17 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
18 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
19 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
20 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
strukts.com
Output results

ks
ar
em
Area of punching Links

R
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
r Check r
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a NO SHEAR REINFORCEMENT REQUIRED a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T14 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
r Check r
a 2 branches T14 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
JOB REF:
PROJECT: YAS NORTH REVISION:
Company logo PART OF STRUCTURE: Column C/6 C 20 CALC. BY: AT
DRAWING REFERENCE: First Floor DESIGN CODE ACI 318-08 CHECK. BY: AT

CHECK FOR PUNCHING SHEAR IN SLABS BASED ON ACI 318-08


a
INPUT DATA
MATERIALS PROPERTIES
fc' = 40 N/mm² CONCRETE STRENGTH 0.8 fcu
fys = 420 N/mm² REBAR YIELD STRESS

CONCRETE DIMENSIONS (RECTANGULAR COLUMN) interior


B = 900 mm COLUMN WIDTH
H = 1200 mm COLUMN DEPTH
T = 250 mm SLAB THICKNESS
Tp = 0 mm DROP PANEL THICKNESS
cover = 50 mm CONCRETE COVER
d = 200 mm EFFECTIVE DEPTH OF THE SECTION
1.67 Permissible maximum punching ratio
APPLIED LOAD
Vu = 793 kN PUNCHING SHEAR FORCE
Mux = 538 kN.m ULTIMATE BENDING MOMENT IN X DIRECTION
Muy = 231 kN.m ULTIMATE BENDING MOMENT IN Y DIRECTION

STEEL REINFORCEMENT DATA


No. Br. 4 NUMBER OF BRANCHES
No. Sides 4 NUMBER OF SIDES
SPACING 75 mm SPACING BETWEEN LINKS

OUTPUT RESULTS interior


TRANSFER OF UNBALANCED MOMENT PCA Edge (short)
b1 = 1100 mm Edge (long)
b2 = 1400 mm Corner
gfx = 0.6285605 1/(1+(2/3)*(b1/b2)^0.5) (ACI 318-08, 13.5.3.2)
gvx = 0.3714395 1 - gfx (ACI 318-08, 13.5.3.1)
(J/C)x = ### mm² MODULUS OF CRITICAL SECTION
gfy = 0.5707432 1/(1+(2/3)*(b2/b1)^0.5)
gvy = 0.4292568 1 - gfy
(J/C')y = ### mm² MODULUS OF CRITICAL SECTION
bc = 1.3333333 RATIO OF LONG TO SHORT SIDES OF THE COLUMN
b0 = 5000 mm
vu = 1.5283292 N/mm² Vu/b0/d+gvx*Mux/(J/C)x+gvy*Muy/(J/C)y
f = 0.75 SHEAR STRENGTH REDUCTION FACTOR (ACI 318-08, 9.3.2.3)
f vn max = 2.3717082 N/mm² f*0.5*(fc')½ (ACI 318-08, 11.11.3.2)
vu < f vn max AREA OF PUNCHING SHEAR IS SATISFACTORY (ACI 318-08, 11.11.3.2) a
as = 40 SCALE FACTOR (COLUMN CONDITION, INTERIOR, EDGE, CORNER) (ACI 318-08, 11.11.2.1)
f vc = 1.4173328 N/mm² MIN. OF: f * 0.17*(1+2/βс) * (fc')½ 2.015952 N/mm² (ACI 318-08, 11.11.2.1)
f * 0.083*(2+(αs * d)/ b◦) * (fc')½ 1.4173328 N/mm²
2 1.08 f * 0.33 * (fc')½ 1.5653274 N/mm²
WHERE (fc')½ <= 8.3 N/mm2 (ACI 318-08, 11.1.2) a
vc max = 1.0751744 kN 0.17*(fc') ½
FOR SHEAR LINKS (ACI 318-08, 11.12.3.1)
vc > vc max
vu > vc SHEAR REINFORCEMENT IS REQUIRED a
vs = 0.9625979 N/mm² (ACI 318-08, 11.11.3.1)
vs max = 4.1742065 N/mm² 0.66*(fc')½ vs < vs max (ACI 318-08, 11.11.3.1) a
Av = 859.46242 mm²
Av each = 53.716401 mm² PER SIDE PER BRANCH
D = 10 mm REQUIRED LINKS DIAMETER 4 branches T10 - 75 EACH SIDE a
x = 935 mm LINKS WILL EXTEND FOR THIS DISTANCE FROM THE FACE OF THE COLUMN 9476.4733 100

718209859.xlsx STЯUKTƧ strukts.com