Column Vu Mu xx Mu yy B H T Tp cover d Links
Section
location kN kN.m kN.m mm mm mm mm mm mm no. spacing Vu / f Vn
1 Edge (short) 1000 22 22 400 1000 400 0 30 370 2 - 100 1.02
2 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
3 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
4 Corner 1666 22 22 400 1000 400 0 30 370 2 - 100 1.84
5 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
6 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
7 Interior 1666 22 22 400 1000 400 0 30 370 2 - 100 0.75
8 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
9 Edge (long) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.26
10 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
11 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
12 Corner 1666 22 22 400 1000 400 0 30 370 2 - 100 1.84
13 Edge (long) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.26
14 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
15 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
16 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
17 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
18 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
19 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
20 Edge (short) 1666 22 22 400 1000 400 0 30 370 2 - 100 1.02
strukts.com
Output results
ks
ar
em
Area of punching Links
R
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
r Check r
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a NO SHEAR REINFORCEMENT REQUIRED a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T14 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
r Check r
a 2 branches T14 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
a 2 branches T12 - 100 EACH SIDE a
JOB REF:
PROJECT: YAS NORTH REVISION:
Company logo PART OF STRUCTURE: Column C/6 C 20 CALC. BY: AT
DRAWING REFERENCE: First Floor DESIGN CODE ACI 318-08 CHECK. BY: AT