PVsyst - Simulation report
Standalone system

Project: FES
Variant: Nouvelle variante de simulation
Standalone system with batteries
System power: 1250 Wp

PVsyst TRIAL Fès - Morocco

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: FES
Variant: Nouvelle variante de simulation

PVsyst V7.4.5
VC0, Simulation date:
10/01/24 00:14

PVsyst TRIAL
with v7.4.5

Project summary
Geographical Site Situation Project settings
Fès Latitude 34.03 °N Albedo 0.20
Morocco Longitude -5.00 °W
Altitude 416 m
Time zone UTC

Meteo data
Fès
Meteonorm 8.1 (1996-2015), Sat=100 % - Synthétique

System summary

PVsyst TRIAL
Standalone system Standalone system with batteries

PV Field Orientation User's needs


Fixed plane Daily household consumers
Tilt/Azimuth 34 / 0 ° Constant over the year
Average 7.0 kWh/Day

System information
PV Array Battery pack
Nb. of modules 10 units Technology Lithium-ion, LFP
Pnom total 1250 Wp Nb. of units 10 units
Voltage 51 V
Capacity 900 Ah

Results summary

PVsyst TRIAL
Useful energy from solar 2020.43 kWh/year
Missing Energy
Excess (unused)
536.40 kWh/year

Project and results summary


0.05 kWh/year
Specific production 1616 kWh/kWp/year Perf. Ratio PR
Available solar energy 2084.14 kWh/year

Table of contents
Solar Fraction SF
76.30 %
79.02 %

2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7

PVsyst TRIAL

PVsyst TRIAL
10/01/24 PVsyst Evaluation mode Page 2/7
Project: FES
Variant: Nouvelle variante de simulation

PVsyst V7.4.5
VC0, Simulation date:
10/01/24 00:14

PVsyst TRIAL
with v7.4.5

General parameters
Standalone system Standalone system with batteries

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 34 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

User's needs
Daily household consumers
Constant over the year
Average 7.0 kWh/Day

PVsyst TRIAL
PV module
Manufacturer
Model
(Original PVsyst database)
Unit Nom. Power 125 Wp
PV Array Characteristics

Generic
TEI125-32P
Battery
Manufacturer
Model
Technology
Nb. of units
Generic
Battery module Li-Ion, 26V 180 Ah
Lithium-ion, LFP
5 in parallel x 2 in series
Number of PV modules 10 units Discharging min. SOC 10.0 %
Nominal (STC) 1250 Wp Stored energy 40.5 kWh
Modules 5 string x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 51 V
Pmpp 1115 Wp Nominal Capacity 900 Ah (C10)
U mpp 29 V Temperature Fixed 20 °C
I mpp 39 A

PVsyst TRIAL
Controller
Universal controller
Technology
Temp coeff.
Converter
Maxi and EURO efficiencies
MPPT converter
-5.0 mV/°C/Elem.

97.0 / 95.0 %
Battery Management control
Threshold commands as
Charging
Discharging
SOC calculation
SOC = 0.96 / 0.80
SOC = 0.10 / 0.35

Total PV power
Nominal (STC) 1.25 kWp
Total 10 modules
Module area 8.8 m²
Cell area 7.8 m²

Array losses

PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)

Module Quality Loss


Loss Fraction
20.0 W/m²K
0.0 W/m²K/m/s

1.0 %
DC wiring losses
Global array res.
Loss Fraction

Module mismatch losses


Loss Fraction
13 mΩ
1.5 % at STC

0.5 % at MPP
Serie Diode Loss
Voltage drop
Loss Fraction

Strings Mismatch loss


Loss Fraction
0.7 V
2.2 % at STC

0.2 %

IAM loss factor


ASHRAE Param.: IAM = 1 - bo (1/cosi -1)
bo Param. 0.05

PVsyst TRIAL
10/01/24 PVsyst Evaluation mode Page 3/7
Project: FES
Variant: Nouvelle variante de simulation

PVsyst V7.4.5
VC0, Simulation date:
10/01/24 00:14

PVsyst TRIAL
with v7.4.5

Detailed User's needs


Daily household consumers, Constant over the year, average = 7.0 kWh/day
Annual values Hourly distribution

Nb. Power Use Energy


W Hour/day Wh/day
Lampes (LED ou fluo) 3 20/lamp 3.0 180
TV / PC / Mobile 1 70/app 3.0 210
Appareils domestiques 1 5/app 3.0 15
Frigo / Congélateur 1 24 4080
Consomm. de veille 24.0 2520
Total daily energy 7005

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
10/01/24 PVsyst Evaluation mode Page 4/7
Project: FES
Variant: Nouvelle variante de simulation

PVsyst V7.4.5
VC0, Simulation date:
10/01/24 00:14

PVsyst TRIAL
with v7.4.5

Main results
System Production
Useful energy from solar 2020.43 kWh/year Perf. Ratio PR 76.30 %
Available solar energy 2084.14 kWh/year Solar Fraction SF 79.02 %
Excess (unused) 0.05 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 0.0 % Cycles SOW 98.3 %
Missing Energy 536.40 kWh/year Static SOW 90.0 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
87.9
104.3
148.8
178.9
GlobEff
kWh/m²
134.6
142.3
173.3
181.6
E_Avail
kWh
143.6
149.9
178.9
184.4
EUnused
kWh
0.000
0.010
0.005
0.005
E_Miss
kWh
67.05
42.97
46.00
37.06
E_User
kWh
150.1
153.2
171.2
173.1
E_Load
kWh
217.2
196.1
217.2
210.1
SolFrac
ratio
0.691
0.781
0.788
0.824
May 205.0 185.0 185.9 0.010 41.07 176.1 217.2 0.811
June 222.5 192.7 189.8 0.000 24.69 185.5 210.1 0.883
July 228.8 203.3 195.8 0.000 34.38 182.8 217.2 0.842
August 209.8 206.6 197.3 0.000 24.24 192.9 217.2 0.888
September 168.9 189.2 185.4 0.000 33.77 176.4 210.1 0.839
October 134.3 175.6 175.0 0.005 49.65 167.5 217.2 0.771
November 96.5 145.2 151.9 0.000 58.31 151.8 210.1 0.723

PVsyst TRIAL
December 84.1 137.9 146.3 0.010 77.21 139.9 217.2 0.644
Year 1869.9 2067.3 2084.1 0.047 536.40 2020.4 2556.8 0.790

Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy

PVsyst TRIAL
10/01/24 PVsyst Evaluation mode Page 5/7
Project: FES
Variant: Nouvelle variante de simulation

PVsyst V7.4.5
VC0, Simulation date:
10/01/24 00:14

PVsyst TRIAL
with v7.4.5

Loss diagram
1870 kWh/m² Global horizontal irradiation
+13.3% Global incident in coll. plane

-2.42% IAM factor on global

2067 kWh/m² * 9 m² coll. Effective irradiation on collectors

efficiency at STC = 14.14% PV conversion

2583 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.34% PV loss due to irradiance level

-10.89% PV loss due to temperature

-1.00% Module quality loss

-0.65% Mismatch loss, modules and strings

-3.63% Ohmic wiring loss

0.00% Unused energy (battery full)


2174 kWh Effective energy at the output of the array

-4.11% Converter Loss during operation (efficiency)

PVsyst TRIAL
-0.04% Converter Loss due to power threshold
0.00% Converter Loss over nominal conv. voltage
Missing energy
0.00% Converter Loss due to voltage threshold
20.96%
2084 kWh Converter losses (effic, overload)
Battery Storage
Direct use Stored -0.02% Battery Stored Energy balance
36.0% 64.0%
+0.76% Battery efficiency loss

-2.44% Charge/Disch. Current Efficiency Loss

-1.37% Battery Self-discharge Current

2021 kWh Energy from the sun

PVsyst TRIAL
536 kWh 2021 kWh Energy supplied to the user

2557 kWh Energy need of the user (Load)

PVsyst TRIAL
10/01/24 PVsyst Evaluation mode Page 6/7
Project: FES
Variant: Nouvelle variante de simulation

PVsyst V7.4.5
VC0, Simulation date:
10/01/24 00:14

PVsyst TRIAL
with v7.4.5

Predef. graphs
Diagramme d'entrée/sortie journalier

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
10/01/24 PVsyst Evaluation mode Page 7/7