Database version
2023.12.14.12.55
Date
05/01/2024
Design Specifications
Anchor
Anchor system fischer Injection system FIS EM plus
Injection resin FIS EM Plus 390 S
Fixing element Threaded rod FIS A M 16 x 200 R,
stainless steel, Property Class R-70
Calculated anchorage 165 mm
depth
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 1
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
Input data
Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 77.40 6.20 0.00 0.00 0.00 0.00 Permanent-Transient/Static
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 2
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
Steel failure
( NRd,s )
βN,s
Anchor no. % Group N° Decisive Beta
1 32.9 1 βN,s;1
2 32.9 2 βN,s;2
3 32.9 3 βN,s;3
4 32.9 4 βN,s;4
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 3
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
( NRd,p )
Eq. (5.2)
Eq. (5.2a)
Eq. (5.2c)
Eq. (5.2c)
Eq. (5.2d)
Eq. (5.2e)
Eq. (5.2f)
Eq. (5.2g)
Eq. (5.2h)
Eq. (5.2i)
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 4
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
βN,p
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 87.7 1 βN,p;1
( NRd,c )
Eq. (5.3)
Eq. (5.3a)
Eq. (5.3c)
Eq. (5.3d)
Eq.
Eq. (5.3e)
βN,c
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 84.4 1 βN,c;1
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 5
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
( VRd,s )
βVs
Anchor no. % Group N° Decisive Beta
1 4.4 1 βVs;1
2 4.4 2 βVs;2
3 4.4 3 βVs;3
4 4.4 4 βVs;4
( VRd,cp )
Eq. (5.7)
Eq. (5.2)
Eq. (5.2a)
Eq. (5.2c)
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 6
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
Eq. (5.2c)
Eq. (5.2d)
Eq. (5.2e)
Eq. (5.2f)
Eq. (5.2g)
Eq. (5.2h)
Eq. (5.2i)
βV,cp
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 3.5 1 βV,cp;1
( VRd,c )
Eq. (5.8)
Eq. (5.8a)
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 7
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
Eq. (5.8b/c)
Eq. (5.8e)
Eq. (5.8f)
Eq. (5.8g)
Eq. (5.8h)
βV,c
Anchor no. % Group N° Decisive Beta
1, 3 20.4 1 βV,c;1
2, 4 20.4 2 βV,c;2
Eq. (5.9c)
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 8
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required. The calculation was done under the assumption that a sufficient
splitting reinforcement is available. In this case the spliiting
failure can be omitted.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate (if present) must
be sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about the
stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 9
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
Installation data
Anchor
Anchor system fischer Injection system FIS EM
plus
Injection resin FIS EM Plus 390 S (other cartridge Art.-No. 544155
sizes available)
Fixing element Threaded rod FIS A M 16 x 200 R, Art.-No. 90456
stainless steel, Property Class R-70
Installation details
Thread diameter M 16
Drill hole diameter d0 = 18 mm
Drill hole depth h2 = 180 mm
Calculated anchorage hef = 165 mm
depth
Drilling method Hammer drilling
Borehole cleaning 2 times blowing,
2 times brushing,
2 times blowing
required activities according the
given instruction in the approval
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap filled
Maximum torque Tinst,max = 60.0 Nm
Socket size 24 mm
Base plate thickness t = 15 mm
Total fixing thickness tfix = 15 mm
Tfix,max
Volume of resin per drill 22 ml/11 scale divisions
hole
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 10
C-FIX 1.121.0.0
Database version
2023.12.14.12.55
Date
05/01/2024
Attachment
Profile type Rectangular hollow tube
cold formed (120x60x5)
Anchor coordinates
x y
Anchor no. mm mm
1 -75 75
2 75 75
3 -75 -75
4 75 -75
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in