DSAS Mk2 - How To Check The Alert Button Loop Continuity

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

DSAS Mk2 INSTRUCTION SHEET

DSAS Mk2 - How to check the alert button loop continuity

Pole Star accepts no responsibility for any damage caused by failure to observe these
Warning instructions.

Required  Small flat head screwdriver


Equipment  DVM (Digital Voltmeter)

Procedure Stage Action

Check that the alert buttons are correctly installed with the protective covers
1 properly attached, check all connections at the alert loop circuit, these include
the alert buttons and at the terminal block (Stage 4). Check any other
connection between cables as well as any break or damage along the length of
the alert button cabling:

2 Remove the metal mount and plastic lid from the DSAS Mk2 unit

3 Remove FUSE2, then FUSE1 from its holder (to avoid losing the fuses, they can
be moved so that only one side of the fuse is in the holder).

London: +44 20 7313 7403 Hong Kong: +852 2520 0951 technical@polestarglobal.com
Panama: +507 301 5748 Sydney: +61 2 4221 5284

Version 1.0 Issue March 2012 1


DSAS Mk2 INSTRUCTION SHEET

4 Check the alert button connection at the terminal block, please ensure there
are no loose connections:

5 Measure the resistance across ALM & LP1 on the terminal block using a DVM.
N.B. The ohms reading should be low.

6 Replace FUSE1, LED1 STATUS should begin to flash followed by FUSE2. Press
and hold the anti-tamper switch (located next to the power pack plug) for 10
seconds and then release to initiate the diagnosis process; after two minutes
LED1 STATUS on the charger board should be green constant, if it continues to
flash orange than the alert loop is still open and further diagnostics will be
required

London: +44 20 7313 7403 Hong Kong: +852 2520 0951 technical@polestarglobal.com
Panama: +507 301 5748 Sydney: +61 2 4221 5284

Version 1.0 Issue March 2012 2


DSAS Mk2 INSTRUCTION SHEET

6 Once the problem has been identified and fixed please contact the shore
based support staff so that a test can be carried out.

7 Replace the metal mount and plastic lid from the DSAS Mk2 unit

8 Reconnect the external power supply

Note: If a crew member is unable to carry out the above, please consider sending a technician
on-board.