Total Weight

Pose No Diameter Detailed Dimensions a (mm) b (mm) Length (mm) Number Weight (kg) (kg)

1 Ø14 200 6050 6450 26 x 2 405

2 Ø14 200 6050 6450 26 x 2 405

3 Ø10 200 300 1300 26 21

4 Ø16 260 1350 1610 64 163


1064

5 Ø10 400 75 1750 40 43

6 Ø10 400 75 550 80 27

FOUNDATION BOTTOM REINFORCEMENT


W (m) B (m) b (m) T (m) H1 (m) H2 (m) H3 (m) H4 (m)

2.74 6.20 0.55 0.35 1.25 0.90 0.25 0.10

Excavation Reinforced Lean Concrete Reinforcement


(m3) Concrete (m3) (m3) (kg)
51.9 14.8 3.8 1064

FOUNDATION PLAN

FOUNDATION TOP REINFORCEMENT

SECTION A-A COLUMN SCHEMATIC VIEW ABBREVIATIONS


F.G.L : Final ground level
NOTES
1) Concrete clear cover will be taken as 75mm.
2) L1 and L2 are given according to the reinforced concrete, not
plain concrete.
3) Allowable bearing capacity of the soil is 100kPa.
4) Material : Concrete = C25
Reinforcement = S420
5) Internal friction angle of the soil is 30°
6) Unit weight of soil is 17 kN/m3
7) For anchor details see tower assembly drawing.
8) This generic drawing is a guideline only and the contractor has to
FOUNDATION CROSS-SECTION make sure that foundation dimensions should be
checked/reviewed and proper soil improvement techniques are
implemented in line with the recommendations of the soil
investigation report of each site before foundation construction.
Designer bears no responsibility for the use of this generic
drawing in foundation construction.

2
REVİZYON
1
REVISION
0 11.02.2020 FIRST ISSUE
RESIM NO
3680-ALS1-25M-FND-0001
DRAWING NO
BAŞLIK
25M TOWER 100kPa FOUNDATION DRAWING
REINFORCEMENT PLAN TITLE
TARİH HAZIRLAYAN KONTROL
DATE DESIGNED BY CHECKED BY
11.02.2020 Z.ALTINSOY M.SAHIN
DURUM
FOR INFORMATION ONLY 0