Professional Documents
Culture Documents
AMG Oil Gas Brochure
AMG Oil Gas Brochure
AMG Oil Gas Brochure
Petrochemical
Solutions
AMG Systems Ltd. 3 The Omega Centre, Stratton Business Park, Biggleswade, Bedfordshire, SG18 8QB
T :: +44 (0) 1767 600 777 F :: +44 (0) 1767 600 077 E :: info@amgsystems.com
Company Registration Number 2838846. Registered Address: Brigham House, High Street, Biggleswade, Bedfordshire, SG18 0LD
AMG are a UK manufacturer
and leading global provider of
environmentally robust Fibre,
Analogue, IP/Ethernet, Wireless
& Hybrid communication
transmission solutions.
OIL, GAS + PETROCHEMICAL SOLUTIONS
Protect Life.
#01
Transmission System
for Submersible
ROVs.
[ Umbilical Cord ]
Sensors & Input/Output ROV Systems Control Sonar/Microphone PTZ Camera & Lights
Submersible
Product Deployed
Solution
Requirement
Challenge
Brief
Integral to the design of a To design a transmit and receive There were four key challenges: AMG's mechanical design Bespoke AMG4000
new range of submersibles, communication system which would: facilities designed and built
transmitter and
technology was required by > Equipment at the ROV end needed bespoke hardware specifically to
to be accommodated within a clearly fit within the submersible's space receiver
the manufacturer to provide defined small space which required
— Provide fibre redundancy in case — Meet stringent safety standards. constraints. Using AMG's 4000
connectivity for multiple of fibre cable breakage. a very compact form factor and low proven resilient single-mode fibre
signal types, from Surface — Be ruggedised to operate reliably heat dissipation. loop technology, increased
Vessel to Subsea Vehicle, — Transmit 8 analogue video feeds, within temperatures between -20°C efficiencies and heat dissipation in
16 bi-directional RS232/RS485 to 70°C. > Wide temperature differential
using very few fibre cores in an ultra-compact design was
plus Gigabit Ethernet. between surface water and subsea achieved. Ruggedised design
what can in some cases be conditions required the equipment
— Transmit all signals across specific ensured operation over a wide
very long umbilical cables of — Provide up to 16 i/o contacts for operator defined CWDM frequencies to operate within a wide but fast
temperature span, ranging from
over 4 kilometres. sensors, alarms and switching of to allow interoperability with other changing temperature range.
-20°C up to 70°C. Modification to
connected equipment. third party devices utilising other
> Interoperability between the
the standard transmission
frequencies.
Signal types included plethora of different types of on- frequencies to reserved CWDM
— Deliver lag-less and loss-less
board equipment that the wavelengths within the ITU-T
analogue video from the (uncompressed) video to the — Provide a unified network
control station. Management interface for all the submersibles could be fitted with. G694 CWDM (Coarse Wavelength
submersible, data control to
communications. Division Multiplexing) grid,
the submersible for operator > Real-time transmission of data and allowed inter-operability with
— Allow operators to configure
control and operation, control serial data types dynamically. video, essential for accurate remote existing equipment from other
relays, audio and Ethernet for operator control in a very transmission equipment
computer communications. demanding subsea environment. manufacturers.
APPLICATION EXAMPLE
#02
Transmission
Systems for off-shore
life safety sites in
the Middle East.
Control Location
Coax Analogue Video
Relay/Contact i/o
Product Deployed
Solution
Requirement
Challenge
Brief
A major manufacturer of Audio To utilise the fibre network without any negative To provide multiple data formats AMG5900 fibre transmission AMG5900 point to
Safety and Voice Evacuation impact to the operation or performance of the (including specialist protocols, series provided the capability to point fibre optic
Systems for deployment in the VA/GA system and build in full redundancy. LonWorks FTT-10 and 20mA transmit up to 16 data or audio transmitter and
fire protection of Oil and Gas current-loop) along with channels on a single fibre core. receiver
installations required a — Provide communications equipment — Deliver a variety of data formats, multiple channels of high quality These channels were board
capable of connecting over 100 including LonWorks/FTT-10, 20mA audio, all incorporated into a configurable, providing the
transmission system to allow sites back an on-shore control loop, alarm/relay contacts and
single device within a very small flexibility the client required to
the expansion of existing location. Ethernet.
and specific footprint. change data combinations and
VA/GA equipment to include EXPANSION A EXPANSION B
VID
— Transmit up 14 channels of — Equipment to operate within types on a per site basis. The
X
TX
R
POWER
over 100 locations on and off simultaneous loss-less and lag-less temperatures ranging from -20°C to
AUDIO
IN/OUT IN/OUT
AUDIO
IN/OUT IN/OUT
T
U
U
The geographical location, dual redundancy option on the
IN
IN
O
O
A1 A2 A1 A2
DATA 1,2
IN
— Integrate with different versions of — Ruggedised single unit construction size constraints, would require complete system resilience. ALARMS 5-8
OUT AUDIO
INPUT IMPEDANCE
AUDIO
INPUT IMPEDANCE
The old and new equipment existing and new VA/GA Life Safety suitable for off-shore tropical passive cooling to be included in 10/100
A1
A2
A1
A2
A3 A3
a central position across the operation over many years. application was designed to be
A8
S1
S2
A8
S1
S2
50K
600R
50K
600R
accommodated in the
the site's fibre infrastructure. manufacturers own mechanical AMG5900
form-factor.
APPLICATION EXAMPLE
#03
Multi-site Hybrid
security systems with
dual redundancy for
an oil refinery.
Control Room
Video Recording and
Control System
5700 5700 5700 5700
RX-DR RX-DR RX-DR RX-DR
Product Deployed
Solution
Requirement
Challenge
Brief
To transmit analogue video, To design and provide the Other commercially available AMG Systems' solution AMG5700-DR point to
transmission system which would: transmission solutions all revolved simultaneously monitors and
Ethernet and low-speed data for point fibre optic
around the use of separate receives optical signals from
camera Pan, Tilt and Zoom monitoring and switching at the dedicated Primary and Secondary transmitters and dual
(PTZ) CCTV, over dual- — Be resilient to a fibre break or — Allow realtime, lag-less PTZ control Control room (Receiving) site, to hardware, ensuring fibre cable redundant receivers
equipment failure out in the field. of CCTV cameras and other change over from Primary to routes are always known and failure
redundant, diverse fibre cable Secondary cable routes in the event does not have any effect on
equipment.
routes from across the whole — Provide automatic self-healing of failure. transmission service.
site back to a main Central transmission. — Alarm on failure (transmission
equipment and fibre). Although adequate in many Alarm indications are generated and
Control Room. applications, it was not acceptable interface with third-party fault POWER
CH1 CH2
— Provide a Management Interface to the client as it would rely on management systems, indicating DATA OUT
DATA IN
AUX
CH A
With over 100 CCTV camera — Comply to 'COTS' (Commercially with Integration into the client's mechanical changeover of optical either a transmit site equipment
DATA / AUDIO
ALARM 1
ALARMS
off-the shelf). control room system. signals, using additional equipment fault or a fibre cable failure. ALARM 2
IN OUT
CH1 1
entry points, key buildings, — Guarantee 15 year availability for — Transmit input/output alarms. failure. All supplied equipment exceeded 2
plant and equipment, the product replacement/expansion. the extended operating temperature 4
IN OUT
POWER
VIDEO / OPTO
DATA OUT
DATA IN
ALARM 1 IN
ALARM 2 IN
CH2
— Require minimum hardware and 2
1
failure and alarm feedback to the the desert environments and was
ALARM 1 IN+ 4
GND 3
transmission. IN + (A) 7 1 1
RS-232
RS-422
RS-485
IN - (B) 8 2 -
7
OUT + (A) 7 7 8
Supply 12-24v ac dc
VIDEO IN
close at hand.