3.4.4 Trouble shooting Flowchart.

i General: When no solutions are available in the flow-chart, please contact an authorized
Varco repair facility for further information.

1. Open elevator does not close while pipe enters the elevator.
P = system pressure
T = close to 0 Psi
XP = close to 0 Psi (Control Switch in “Close” position.)

1. Does pipe hit the NO


Check elevator rotation angle, adjust if
trigger / body bushings necessary.
properly ? Check if links are tilted sufficiently for pipe to
engage body bushings, adjust if necessary.
Check if the body bushings are properly
installed and can move freely to hit trigger.
YES

2. Is the trigger valve


line marked with # 5 NO Check functioning of valve L.
pressurized when pipe Cartridge PD-10-40-NS-110
hits body bushings?

YES

3. Does gauge on “T”


YES
gauge connector read Tank line blocked, check QD’s and replace if
out extremely high necessary.
pressure (e.g. 400 Psi
or higher)

NO

4. Is the pressure on YES Component E (DPBO-LAN) probably blocks


the line #6 close to
flow back to tank, check cartridge for dirt or
system pressure ?
malfunctioning, replace if necessary .

NO

Next page

BX 3, 4-50, 4-75 & 5revA 42 08/03/2001 PGF


Component F (DCCC-XXN)not shifted to the
5. Is the pressure on NO
right despite of pressure on #5 and NO
the line #7 close to pressure on #6: Cartridge stuck, check
system pressure ? functions and mounting torque, replace if
necessary.

YES

NO Component H (CKCB-XEN) probably stuck in


6. Is the pressure on closed position, check functions and replace if
the line #9 close to 0 necessary.
Psi ?

2. Elevator will close but not latch. (NO CLOSED SIGNAL)


P = system pressure
T = close to 0 Psi
XP = close to 0 Psi

Check if something is stuck between doors.


1. Do both doors close Remove object
completely to hard NO Check if cylinders have sufficient stroke to
stops (welded on inside close doors completely, adjust if necessary..
contact area between Lock cylinder rods with nut and lock tab after
doors and body lugs) ? adjustment.

YES

Check cylinder signal in line #10 to be close to


2. Is the pressure on system pressure, adjust cylinder stroke if
line #11 (“latch-out”) NO
signals are not fully present.
close to system Component K (CVCV-XEN) probably stuck,
pressure ? replace if necessary.

YES

3. Is the pressure NO If pressure reads high component M (CVCV-


on the line
XEN) probably stuck, check and replace if
marked with #14
close to 0 Psi ? necessary.

YES

4. Does the latch YES


cylinder mal- Check Cylinder, Disassemble Replace cylinder
function , is it if necessary.
stuck ?

NO

Next page

BX 3, 4-50, 4-75 & 5revA 43 08/03/2001 PGF


5. If elevator is closed NO
and latched & Check Pressure in line 12 to be close to
elevator “Floats”, is system pressure, adjust cylinder stroke if
1000psi XP signal is signal not fully present. No signal at all is faulty
cylinder, replace cylinder if necessary.
present?

YES

NO Check XP Pressure 1000psi at the HUK


6. If elevator is closed
and latched. & control manifold. Check pressure switch on
indicator- light at HUK Elevator control manifold for pressure
control Panel is ON? setting being too high. Check setting of bleed-
off valve on HUK manifold.

3. Closed elevator will not open while commanded to open.


P = system pressure.
T = close to 0 Psi.
XP = System pressure or higher.

1. Is tool joint/coupling set on


the spring-loaded door YES Lower the elevator until the spring loaded door
bushing and so activating the bushing releases the latch lock and allows the latch
mechanical elevator latch to open.
lock?

NO

2. Is the moveable door-


bushing stuck? Or is the YES Check latch lock mechanism for proper function.
latch locking mechanism Take out moveable bushing and clean and grease
stuck. (broken spring) back of bushing, reassemble.

NO

Next page

BX 3, 4-50, 4-75 & 5revA 44 08/03/2001 PGF


3. Is XP line pressure equal Check ‘XP’ QD for correct function. Check XP -line
or higher than the P –line NO filter for correct function. Adjust PRV “PC1” at the
pressure, check this at the HUK control manifold until XP pressure is equal or
elevator manifold. higher then P line pressure, if necessary.

YES

4. Is the pressure on the NO Check pressure setting of component E (DPBO-


line marked with #6 equal
LAN) to be 1500psi, inspect it for dirt/malfunction
to XP line pressure ?
and replace if necessary.

YES

5. Is the pressure on the NO Check component F (DCCC-XXN), inspect it for


line marked with #8 equal
dirt/malfunction and replace if necessary.
to P line pressure ?

YES

NO
6. Is the pressure on the
Check component M (CKCB-XEN), inspect it for
line marked with #14 equal
dirt/malfunction and replace if necessary.
to P line pressure ?

YES
Return flow latch cylinder blocked, check
component K (CVCV-XEN), inspect for
7. Is the pressure on the NO dirt/malfunctioning and replace if necessary.
line marked with #11 close Check QD’s etc. of T-line to be OK, replace if
to 0 Psi (Tank pressure)? necessary.

BX 3, 4-50, 4-75 & 5revA 45 08/03/2001 PGF


4. Elevator is hesitating to open.
P = System pressure
T = close to 0 psi
XP = system pressure or higher

1. Is component E NO Set component E (DPBO-LAN) at 1500 Psi..


(DPBO-LAN) set at
1500 Psi ?

YES

NO
2. Is system pressure Adjust system pressure to 2000Psi at the elevator.
2000 Psi min &
2500psi max. at the
elevator?

5. T HE ELEVATOR OPENING / CLOSING OPERATION IS SLOW .

1. Is the flow (partly) YES Replace damaged QD.


blocked in one of the QD’s
(check for damage) ?

NO

YES Clean filters with a solvent.


2. Is one of the filters A Replace filters if necessary.
and/or B clogged with dirt

NO

3. Is one of the restrictors


YES Remove dirt.
(lines #7 and #11) (partly)
blocked with dirt ?

BX 3, 4-50, 4-75 & 5revA 46 08/03/2001 PGF


6. Elevator closes immediately when Control Switch is put into “armed to
close” without (pipe) operating the trigger.

1. Is the trigger stuck,


YES YES Check proper functioning of the trigger
activating valve L (PD-10- mechanism. Check body bushing for free
40-NS-110) continuously? movement on their locating pins.
Check pressure in line #5, should read out to 0
Psi.(Tank pressure) when trigger is de-
NO activated.

2. Is line 7 pressurized
YES Check proper functioning of valve F (DCCC-
immediately after putting
the Control Switch into XXN) Valve probably stuck in controlled
position, replace if necessary.
“armed to close” position?

7. Rotated elevator will not close/latch onto pipe being presented under an
angle.

Does rotator stop at an Adjust the stop pin’s of the rotator to get a proper
YES
angle different from the alignment of the elevator and the pipe
pipe angle ?
YES

NO
Check whether a correct bushing size is fitted.
Go thru item 1 of this paragraph.

BX 3, 4-50, 4-75 & 5revA 47 08/03/2001 PGF