EDG-20P-6
POWER RATING
With 60 Hz of frequency
Output voltage (Vac), 3Phase 416 ~ 480 Volts(208-240volt option), 380VOLT consulted by EVERDIGM.
y RELIABLE HIGH QUALITY y FREQUENCY REGULATION y Applied the 2/3 pitch winding to
SYSTEM- To improve the ACCURACY- Under varying reduce the 3rd harmonics.
performance of Products, high loads from no load to 100% load
quality auxiliaries equipment at the rated power factor(0.8), y Designed by using the latest
applied and optimized protection frequency regulation is technologies and the best
device built in the digital 5%(mechanical type governor), materials available to guarantee
controller against malfunctioning 1%(electric type governor). high efficiency value.
and abnormal conditions.
y VOLTAGE REGULATION y Impregnated with high-grade
y SIMPLE AND EASY ACCURACY- Under varying resin and protection against
OPERATION- With centralized loads from no load to 100% load hostile environment is provided
controls simplifying generator at the rated power factor (0.8), as standard.
operation and supervision is voltage regulation is less than
made very simple. ±2.5%. y Supplied with over exciting
current and under frequency
y LOW COST MAINTENANCE & y VOLTAGE ADJUSTABLE protection built in the AVR.
OPERATION- Use the RANGE- Under rated speed and
specialized diesel engine for no load condition, voltage y Suitable for parallel operation
generator set keeps operation adjustable range is less than with other generator or mains
costs very low. ±5% of rated voltage. power. (Parallel kit is available
on request.)
GENERATOR
SPECIFICATION
SWITCH& PUSH BUTTON
Manual/Remote/Auto button O
Stop button O
GCB Close/Trip button O
Alarm button O
Direction/Enter/ESC button O
Emergency stop push button O
Main Power Switch O
Voltage Adjuster O
DISPLAY
Digital Volt./Current/Power/PF/Hz O
Running Hours/Kilowatt hour O
RPM/DC Voltage O
Oil press./Coolant temp O
Cooldown time/Mains power live/Failure sensing time O
BREAKER
Main molded case circuit breaker (MCCB 4P) O (3P as option)
Circuit protector for DC source O
Breaker for main power/coolant heater O
INDICATOR & PROTECTION SYSTEM
Main power lamp O
Manual/Remote/Auto, LED O
Running, LED O
GCB close/trip, LED O
Emergency stop, LCD O
Over voltage/Under voltage/Over Current, LCD O
High coolant temperature, LCD O
Low lub. oil pressure, LCD O
Fail to start, LCD O
Over speed, LCD O
REMOTE SYSTEM
PC Monitoring program ▲
Dry Contact (Mains Power, Running, Fault) O
CONTROL SYSTEM
SPEED CONTROL UNIT O
OTHERS
Dry Contact (Extension Module) ▲
Battery Charger O
Engine
Fuel oil filter Engine
Lub. oil filter and drain valve Battery auto charger (For Standby Power usage)
Air cleaner
Lubricate oil Control panel
Fan Belt Self-standing panel
Manual
Operation & Maintenance manual
Generator part book
NOISE LEVEL
7<3( 12/2$' P P
6281'3522) G%$ G%$