Professional Documents
Culture Documents
Inmarsat-C Mes Model Felcom18
Inmarsat-C Mes Model Felcom18
INMARSAT-1 MES
Model FELCOM18
1. MOUNTING..............................................................................................................1-1
1.1 Antenna Unit ......................................................................................................................1-1
1.2 Terminal Unit......................................................................................................................1-3
1.3 Distress Alert/Received Call Unit IC-305/Alarm Unit IC-306..............................................1-5
1.4 Printer (option) ...................................................................................................................1-6
1.5 AC/DC Power Supply Unit PR-240 (option).......................................................................1-7
1.6 Junction Box IC-318...........................................................................................................1-8
2. WIRING....................................................................................................................2-1
2.1 Antenna Cable Connector at the Terminal Unit .................................................................2-2
2.2 Distress Alert/Received Call Unit IC-305 ...........................................................................2-7
2.3 Alarm Unit IC-306 ..............................................................................................................2-7
2.4 Junction Box IC-318...........................................................................................................2-8
3. INITIAL SETTINGS..................................................................................................3-1
3.1 How to Set the IMN (INMARSAT MOBILE NO.)................................................................3-1
3.2 How to Set External Equipment .........................................................................................3-2
3.3 How to Set the Alarm Contact............................................................................................3-3
3.4 How to Set up the AMS/BAM.............................................................................................3-3
3.5 How to Select Position-fixing Equipment ...........................................................................3-6
3.6 How to Set up for 2nd DTE ................................................................................................3-6
3.7 How to Set the Russian Language ....................................................................................3-7
3.8 How to Use the Paper Save Function................................................................................3-7
3.9 How to Output EGC Messages..........................................................................................3-8
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
7KHSDSHUXVHGLQWKLVPDQXDO
LVHOHPHQWDOFKORULQHIUHH
࣭)85812$XWKRUL]HG'LVWULEXWRU'HDOHU
$VKLKDUDFKR
1LVKLQRPL\D-$3$1
SAFETY INSTRUCTIONS
WARNING CAUTION
Do not open the equipment
unless totally familiar with Confirm that the power supply
electrical circuits and voltage is compatible with the
service manual. voltage rating of the equipment.
i
SYSTEM CONFIGURATION
Standard configuration is shown with solid line.
ANTENNA
UNIT IC-118
DGPS
TERMINAL UNIT
POWER SUPPLY IC-218
100-115/200-230 VAC ,
1φ 50/60 Hz AC/DC Power Supply Personal Computer
POWER SUPPLY PR-240 (PC/AT compatible)
24 VDC
Built in
POWER SUPPLY GPS Board Shipboard LAN (Ethernet)
12/24 VDC OP16-62
Printer**
POWER SUPPLY PP-510/
24 VDC PP-520
For 12 VDC power supply,
DC-DC converter is Mini Keyboard
Distress Alert/
required to use PP-510 or 5139U or 5139U BLACK
Received Call Unit
PP-520. IC-305 or 350
ii
EQUIPMENT LISTS
Standard supply
Name Type Code No. Qty Remarks
Antenna Unit IC-118 - 1 w/FP16-02501
Terminal Unit IC-218 - 1 w/CP16-05200, SP16-01301, FP16-02600
Junction Box IC-318 - 1
SSAS Alert Unit IC-307 - 2 For SSAS only
Installation CP16-05511 001-189-560 1 For IC-118, 30 m
Materials
Optional supply
Name Type Code No. Qty Remarks
Printer PP-520 - 1
Distress Alert/ Re-
IC-305 - 1
ceived Call Unit
Alarm Unit IC-306 - 1
AC/DC Power Supply
PR-240 - 1
Unit
SSAS Alert Unit IC-307 - 1
PC Terminal Software OP16-57 001-180-050 1
Cable Assy. COSPEVVSBC 5PX0.2LF 000-560-452-11 1 5P, 10 m
COSPEVVSBC 5PX0.2LF 000-103-868-11 1 5P, 20 m
COSPEVVSBC 5PX0.2LF 000-103-869-11 1 5P, 30m
COSPEVVSBC 5PX0.2LF 000-132-829-11 1 5P, 40 m
COSPEVVSBC 5PX0.2LF 000-132-828-11 1 5P, 50 m
Flush Mount Kit OP16-27 004-448-000 1 For IC-305/306
OP16-28 004-448-010 1 For IC-307
Antenna Unit IC-118 - 1
Antenna Bracket CP16-05602 001-189-610 1 For IC-118
Antenna Base w/Hose OP16-72 001-323-420
1
Clamp
Antenna Base w/ OP16-73 001-323-430
1
Mount Pipe
Antenna Base 2/U Bolt OP16-74 001-313-440 1
Antenna Base OP16-75 001-313-450 1
IPX2 Kit OP16-58 001-180-070 1 D-sub cables
Water Proof Kit OP16-59 001-180-080 1 For IC-218
OP16-60 001-180-090 1 For IC-318
OP16-67 001-189-380 1 For IC-305
OP16-68 001-189-400 1 For IC-307
GPS Board Kit OP16-62 001-180-100 1 For IC-218
Bracket Kit OP16-65 001-182-900 1
Key Template OP05-135 001-184-560 1 For Russian flag
vessels
iii
EQUIPMENT LISTS
iv
1. MOUNTING
NOTICE
Do not apply paint, anti-corrosive sealant or contact
spray to coating or plastic parts of the equipment.
Those items contain organic solvents that can damage
coating and plastic parts, especially plastic connectors.
2m
5m
S-band radar HORIZONTAL LINE
1-1
1. MOUNTING
• The allowable vibration level as specified by Inmarsat is as shown in the table be-
low.
Allowable vibration level
Frequency Level
2 to 10 Hz 2.54 mm Peak Amplitude
10 to 100 Hz 9.8 m/s2 Peak Acceleration
• Avoid the location near tunnels and stacks; smoke and soot on the radome can low-
er signal level (10 m or more in horizontal distance).
• Separate the antenna unit 5 m from HF, VHF of 27 MHz antenna.
1.1.2 Mounting
The antenna cable is available in lengths of 30 m, 50 m and 100 m (see table below).
Antenna installation
Select a location to weld the grounding stud bolt (M6), keeping in mind the length of
the grounding cable RW-4747 (Included as installation materials) is 340 mm. The lo-
cation for welding the grounding stud bolt should allow the antenna ground and mast
ground to be connected with the grounding cable (to ground lightning strikes). For de-
tailed measurements, refer to the outline drawings at the back of this manual.
For information on wiring the antenna cable, refer to the manual included with the an-
tenna unit.
Ground wire
1-2
1. MOUNTING
Mounting
Tabletop mount
1) Fix the hanger (option) to a table with four self-tapping screws (5x20, supplied), re-
ferring to the outline drawing at the back of this manual.
2) Screw knobs and washers to terminal unit loosely.
3) Set the terminal unit to the hanger and tighten knobs.
Flush mount
Use locally supplied pan head screws (M4x20) when the thickness of the bulkhead is
from 11 to 14 mm. For bulkhead which exceeds 14 mm in thickness the length of the
pan head screws should be bulkhead thickness A +7.8±2 mm. Also the length of B
should be max. 8 mm (Bd8 mm).
B A
1-3
1. MOUNTING
Sponge for
LAN terminal
2. Use the binding screw (pre-attached at the rear of the unit) to fix the LAN cable
support.
LAN cable
support
3. Connect the LAN cable to the terminal unit. Fix the LAN cable to the LAN cable
support with a cable tie (supplied).
Binding screw
1-4
1. MOUNTING
Keyboard
1. Attach the function key label (IMN-C18) to the keyboard as shown below.
2. Attach four fasteners (small, supplied) to the bottom of the keyboard.
3. Attach four fasteners (large, supplied) to the small fasteners attached at step 2.
4. Remove the paper from four fasteners.
5. Fasten the keyboard to the mounting place.
or
ALARM ALARM
ACK ACK
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top
cover.
2. Fix the bottom chassis to the mounting location with four self-tapping screws (sup-
plied).
3. Cable can be led in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows.
1) Unfasten two screws to remove the cable clamp.
2) Turn the clamp 90 degrees.
1-5
1. MOUNTING
Rotate.
4) Run the interconnection cable thorough a cable entrance and connect it to ter-
minal board.
Flush mount
The optional flush mounting kit OP16-27 (Code No.: 004-448-000) is required.
1-6
1. MOUNTING
1-7
1. MOUNTING
1. Remove four screws from the unit to separate the bottom chassis from the top
chassis.
2. Fix the bottom chassis to the mounting location with four self-tapping screws
(4x16, supplied).
3. Connect the cables referring to Chapter 2.
1-8
2. WIRING
24 VDC
VCTF-0.75x3C (5 m)
TNCP-NJ
connector DGPS
(Supplied)
LAN cable
Connector N-P-5DFB (100Base-TX, local supply)
N-P-8DFB Mini keyboard
N-P-12DSFA (to USB terminal
(Supplied, local arrangement) on the front panel)
Copper strap
MJ-A3SPF0018-050Z 1.2 m
CO-SPEVV-SB-C 0.2x5p
(option) or TTYCS(LA)-4
(Japanese Industrial
Standards)
IC-307 Navigator
Wiring of FELCOM 18
2-1
2. WIRING
Insulator Ring
Shell
Set the shell to the cable then turn the nut to
tighten. (Do not tighten by turning shell.) -
Use a wrench or the like to tighten the nut
securely.
Nut
2-2
2. WIRING
Dimensions in millimeters.
Outer Sheath Remove outer sheath and armor by the
Armor Inner Sheath Shield dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
50 30
30 10
1
Expose the insulator by 1 mm.
5
Expose the insulator by 5 mm.
Pin
Clamp Nut Slip the pin onto the conductor. Solder them
Shell
together through the hole on the pin.
2-3
2. WIRING
Dimensions in millimeters.
Outer Sheath
Armor Inner Sheath Shield Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the dimen-
50 30 sions shown left.
30 10
U-shaped groove
Slip on clamp nut, gasket and clamp as shown
left.
Clamp Nut Pin Shell Slip the pin onto the conductor. Solder them
together through the hole on the pin.
Insert the pin into the shell. Screw the clamp
nut into the shell.
Solder through the hole. (Tighten by turning the clamp nut. Do not
tighten by turning the shell.)
2-4
2. WIRING
Outer sheath 50 15
Center pin
Fold back the shield. Remove the
shield that hangs over the gasket.
Apply solder to core.
Center pin
(Soldering)
2-5
2. WIRING
Dimensions in millimeters
Outer sheath
95
Remove outer sheath and armor by the
15 dimensions shown left.
Remove inner sheath and expose shield
by the dimensions shown left.
Armor Inner sheath Shield
10
Remove the insulator beneath shield by
10 mm and expose the core.
30
5
Fold back aluminum tape over clamp and
Trim aluminum trim.
tape here.
Slip the pin onto the conductor. Solder
them together through the hole on the pin.
Insert the pin into the shell. Screw the
Pin clamp nut into the shell.
Clamp nut Solder through Shell Tighten them by turning the clamp nut.
the hole. (Do not tighten by turning the shell.)
2-6
2. WIRING
16P0213
For CO-SPEVV- 1 2 3 4 5
SB-C 0.2x5P
16P0213 JP2
JP1
2-7
2. WIRING
For connection, use the optional 5 pair cable CO-SPEVV-SB-C 0.2x5P, JIS cable (Ja-
pan Industrial Standard) TTYCS(LA)-4 or equivalent.
1 Vcc
IC-305/306
2 GND
Cover 3 TD/RD-A
4 TD/RD-B
5 NC
6 ALM-H 1
7 ALM-C 2
8 RD-A(NAV)
Cable clamp 9 RD-B(NAV)
10 GND
11 SSAS OUT-H
12 SSAS OUT-C
13 SSAS IN-H
Terminal board 14 SSAS IN-C 3 Core 7 mm
15 SSAS CTR
Sticker for
connection of
other equipment Procedure
1. Insert from direction 1 .
2. Tilt slightly toward 2 .
For TTYCSLA cable, use the screws
and crimp-on lugs shown below to 3. Insert cable core to 3 .
connect the drain wire of that cable.
4. Pull out the screwdriver.
Screws and crimp-on lugs
Note 1: Do not insert the wire deeply, to
(supplied in the IC-318)
prevent pinching its sheath.
15 mm 90 mm 7 mm
Input sentences
The following sentences can be input by a GPS navigator.
Input sentences
BWC, BWR, DBT, DTM, GGA, GLL, GNS, GSA, MTW, RMA, RMB, RMC,
VDO, VDR, VTG, WPL, ZDA
2-8
3. INITIAL SETTINGS
This chapter shows you how to setup the equipment. Some procedures require entry
of job no. and password. Ask your dealer.
File Edit Transmit EGC Reports Logs Options Setup Distress StopAlarm
Setup
1. System Setup
2. Editor Setup
3. Terminal Setup
4. EGC Setup
5. Auto Mode Setup
6. E-Mail Setup
7. Directories
8. Configuration
4. Confirm that [IMN] is selected, and then press the Enter key.
An input box appears.
5. Key in your IMN.
6. Press the Enter key.
To clear the IMN, select [IMN], then press I, M, N while pressing the Alt key. Re-
peat step 4 to step 6 to input the correct IMN.
7. Press the Esc key.
8. Press the Enter key.
9. Press the Esc key.
3-1
3. INITIAL SETTINGS
3-2
3. INITIAL SETTINGS
[ Unit Fault ]
1. ON
2. OFF E: Exit
6. Press appropriate numeric key (1 to 4), then press the Enter key.
To return to the [AMS Setup Menu], press the E key at the setting window.
3-3
3. INITIAL SETTINGS
3-4
3. INITIAL SETTINGS
3-5
3. INITIAL SETTINGS
Connect List
No. Name IMN IP Address Software Version
*01 F18_123456 123432588 172.31.16.100/24 1650247-01
02 F18_133234 456789210 192.168.16.11/24 1650247-01
03
04
05
06
07
08
09
10
The No., Name, IMN, IP address and software version of each terminal are
shown. The asterisk marks the terminal currently selected for communication.
3. To connect to a different terminal, select it then press the Enter key. The [Con-
nect] window appears and [Yes] is selected. Press the Enter key to connect the
terminal.
3-6
3. INITIAL SETTINGS
4. Press and hold down the left Shift key while pressing the left Alt key.
The language for the keyboard is switched from English to Russian. The Scroll
Lock lamp lights when Russian is selected. To switch the language from Russian
to English, press and hold down the left Shift key while pressing the left Alt key.
Note: With a 2nd DTE, Russian can be input from the keyboard of your PC. See
your PC’s owner’s manual for how to switch languages.
5. Put the key template for Russian (OP05-135) on the keyboard of your PC.
3-7
3. INITIAL SETTINGS
The output messages, in IEC 61162 format, are SM1, SM2, SM3, SM4, and SMB.
3-8
4. HOW TO INSTALL OPTIONAL
EQUIPMENT
Torque Nut
0.76±0.02 N m Rounding
side
Nut,
Torque flat washer
1.37±0.1 N m Cover
Spacer
6 pcs.
Pan head screw
M3x8, 18 pcs.
* *
*
* ** ** *
*
* *
* *
* * *
*
* * * *
*
* * *
*: Remove.
2. Fasten three binding screws (M3x6, supplied with the kit) to attach the GPS Board
to the RF cover.
4-1
4. HOW TO INSTALL OPTIONAL EQUIPMENT
Binding screw
M3x6, 3 pcs.
J6
GPS board
J13
4. Attach the cable from the GPS board to J6 on the RF COMMCPU Board.
Use the clamp next to the connector to fix the cable.
5. Reassemble the terminal unit.
4-2
4. HOW TO INSTALL OPTIONAL EQUIPMENT
USB port
1
Attach the cover for USB
(16-023-3535) to the USB
connector, then connect it to
the terminal unit.
2
Fasten two binding screws
(pre-attached) to fix the USB
support (16-023-3536) as
shown right.
USB support
4-3
4. HOW TO INSTALL OPTIONAL EQUIPMENT
D-sub ports
1
Peel the paper from the
sponge for Dsub (16-023-
3531), then attach the sponge
to the D-sub connectors at the
rear of the terminal unit.
2 (Cables connected)
4-4
4. HOW TO INSTALL OPTIONAL EQUIPMENT
DGPS port
(Coaxial cable connected)
1
Pass the coaxial cable
through the slit on the cover
for BNC (16-023-3534).
2
Attach the connector* of the
coaxial cable to the DGPS
port.
3
Slide the cover for BNC on
the connector to cover the Triangle mark
connector. Confirm that the
triangle mark on the cover is
upward.
4-5
4. HOW TO INSTALL OPTIONAL EQUIPMENT
Cap
2
Re-attach the cap to the
DGPS port.
4-6
4. HOW TO INSTALL OPTIONAL EQUIPMENT
When the OP16-58 (described in paragraph 4.2.1) is used, replace the cable from the
IC-318 with the XM-FD-361 as shown below.
4-7
4. HOW TO INSTALL OPTIONAL EQUIPMENT
(IC-305) (IC-307)
4-8
5. HOW TO CHANGE POWER SUP-
PLY SPECIFICATIONS
The AC-DC power supply PR-240 is shipped ready for connection to a 200-230 VAC
ship’s mains. If the ship’ mains is 100 VAC, change the tap connection and terminal
board connection as below. Attach a label supplied as accessories to the front panel
according to the ship’s mains.
Remove screw
and cover.
Cover
Front panel
(a) 200-230 VAC
Relay
1 Black Coil
2 Gray 3
J4 2
3 1
SEL
Terminal board 1
115V
2
3 Heat sink
4 SEL
(b) 100-115 VAC 5 230V
6
1 Black 7
8
2 Gray
3
Tap connection
(Pull out to disconnect.)
Front panel
Attach appropriate label.
5-1
5. HOW TO CHANGE POWER SUPPLY SPECIFICATIONS
5-2
APPENDIX 1 JIS CABLE GUIDE
Cables listed in the manual are usually shown as Japanese Industrial Standard (JIS). Use the following guide to locate
an equivalent cable locally.
JIS cable names may have up to 6 alphabetical characters, followed by a dash and a numerical value (example:
DPYC-2.5).
For core types D and T, the numerical designation indicates the cross-sectional Area (mm2) of the core wire(s) in the
cable.
For core types M and TT, the numerical designation indicates the number of core wires in the cable.
1 2 3 4 5 6 1 2 3 4
The following reference table lists gives the measurements of JIS cables commonly used with Furuno products:
Core Cable Core Cable
Type Area Diameter Diameter Type Area Diameter Diameter
AP-1
,&$ ,&$* ,&$ +. $9;
㹎㸿㹁㹉㹇㹌㹅ࠉ㹊㹇㹑㹒
1$0( 287/,1( '(6&5,37,21&2'(θ 4 7< 1$0( 287/,1( '(6&5,37,21&2'(θ 4 7<
㺡㺛㺢㺱㺎㺢㺼᧯సᡭ㡰
&
ࣘࢽࢵࢺ 81,7 66$67(6702'(+$1'%22.
㺞㺮㺣㺷㺳㺤㺠㺢
,&$ 㺩㺋㺎㺛㺼ኚ᭦ࡢ࠾㢪࠸
7(50,1$/81,7 & 㺺㺒㺐
127,),&$7,21'2&80(17
ᅗ᭩ '2&80(17
㺏㺪㺽㺶㺗㺎㺚㺌㺻㺪㺉㺯
- 㺺㺒㺐
5(*,675$7,21)256(59,&(
$&7,9$7,21
䡶㻙䢀䢚␒ྕᮎᑿ䛾㼇㻖㻖㼉䛿䚸㑅ᢥရ䛾௦⾲䡶䡬䢀䢚䜢⾲䛧䜎䛩䚹
㻯㻻㻰㻱㻌㻺㼁㻹㻮㻱㻾㻌㻱㻺㻰㻵㻺㻳㻌㼃㻵㼀㻴㻌㻎㻖㻖㻎㻌㻵㻺㻰㻵㻯㻭㼀㻱㻿㻌㼀㻴㻱㻌㻯㻻㻰㻱㻌㻺㼁㻹㻮㻱㻾㻌㻻㻲㻌㻾㻱㻼㻾㻱㻿㻱㻺㼀㻭㼀㻵㼂㻱㻌㻹㻭㼀㻱㻾㻵㻭㻸
㻔㻖㻝㻕䛾᭩㢮䛿䚸ⱥᩥᵝᑓ⏝䛷䛩䚹
㻔㻖㻝㻕㻌㻹㻭㻾㻷㻱㻰㻌㻰㻻㻯㼁㻹㻱㻺㼀㻿㻌㻭㻾㻱㻌㻲㻻㻾㻌㻱㻺㻳㻸㻵㻿㻴㻌㻿㻱㼀㻌㻻㻺㻸㼅㻚
A-1
㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧
&=)
#8: #8:
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀
('.%1/# ('.%1/# *-('.%1/#) A-2 ('.%1/# 55#5('.%1/#) 55#5 A-3
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
%<'
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 %<'
#8: #8:
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀
+%*- A-4 +% A-5
+% +%
#06'00#70+6 ,70%6+10$1:
ઃዻຠ #%%'5514+'5 Ꮏ᧚ᢱ +056#..#6+10/#6'4+#.5
ઃዻຠ Ꮏ᧚ᢱ
(2 %2
#%%'5514+'5 +056#..#6+10/#6'4+#.5
࿑ᦠ &1%7/'06
㨻㩧㩍㩏឵ᣇᴺ
6+%
#06'00#+056#..4'2#.%'
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ䍘䍎䍢䍼䉕䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%<$ %<#
16AK-X-9856 -3 1/1 16AK-X-9855 -3 1/1
PACKING LIST PACKING LIST
A-6 A-7
IC-306 IC-305
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
ユニット UNIT ユニット UNIT
着信指示器 遭難警報器
IC-306 1 IC-305 1
ALARM UNIT DISTRESS ALERT UNIT
000-043-429-00 000-043-427-00 **
工事材料 INSTALLATION MATERIALS CP16-02201 工事材料 INSTALLATION MATERIALS CP16-02201
+トラスタッピンネジ 1シュ +トラスタッピンネジ 1シュ
3X10 SUS304 4 3X10 SUS304 4
SELF-TAPPING SCREW SELF-TAPPING SCREW
000-162-604-10 000-162-604-10
圧着端子 圧着端子
FV1.25-3(LF) 4 FV1.25-3(LF) 4
CRIMP-ON LUG CRIMP-ON LUG
000-166-756-10 000-166-756-10
圧着端子 圧着端子
FV2-3 1 FV2-3 1
CRIMP-ON LUG CRIMP-ON LUG
000-157-246-10 000-157-246-10
図書 DOCUMENT
IC-305/307引き渡し前の注意
C52-00202-* 1
BEFORE DELIVERING TO OWNER
(*1)
000-809-354-1*
ᕤᮦᩱ⾲ Ꮏ᧚ᢱ
,167$//$7,210$7(5,$/6 +056#..#6+10/#6'4+#.5
␒ྕ ྡࠉࠉ⛠ ␎ࠉࠉᅗ ᆺྡ㸭つ᱁ ᩘ㔞 ⏝㏵㸭ഛ⪃ ⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
12 1$0( 287/,1( '(6&5,37,216 4 7< 5(0$5.6 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㺘㺻㺫㺼㺍㺖㺛 㺏㺻㺡㺣㺗㺎㺪㺼㺷ᅛᐃ⏝ 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
)RUVHFXULQJWKH
&9% DQWHQQDFDEOH :575
&$%/(7,( 5'.(6#22+0)5%4'9
&2'( %1&'01
12
㺪㺼㺟㺷㺘㺼㺯㺡㺎㺪㺽
12
6(/)%21',1*7$3(
&2'(
12
㺗㺎㺪㺼㺷⤌ရ
5:
&$%/($66<
&2'(
12
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
㸦␎ᅗࡢᑍἲࡣࠊཧ⪃್࡛ࡍࠋࠉ',0(16,216,1'5$:,1*)255()(5(1&(21/<㸧 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㹄㹓㹐㹓㹌㹍ࠉ㹃㹊㹃㹁㹒㹐㹇㹁ࠉ㹁㹍ࠉ㸬㸪㹊㹒㹂 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
&0' %/#
A-12 A-13
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
%/#
D-1
24/Jan/2012 Y.NISHIYAMA
D-2
24/Jan/2012 Y.NISHIYAMA
'
'
17/May/2012 Y.NISHIYAMA
'
July 14'03
17/May/2012 Y.NISHIYAMA
'
'
6/Oct/2010 Y. NISHIYAMA
16/Jun/2014 H .M A KI
'
26/Oct/09 R.Esumi
'
6/Jul/2012 Y.NISHIYAMA
'
'
17/May/2012 Y.NISHIYAMA
'
30/Apr/2012 Y.NISHIYAMA
D-15
S-1
1 2 3 4 5 6
アラームユニット
1 VCC ALARM UNIT
P
2 GND IC-306
3 TD/RD-A *2
P
4 TD/RD-B
アンテナユニット GND
ANTENNA UNIT 5
IC-118
ターミナルユニット IC-350を接続するとき(IC-305との共用不可)
TERMINAL UNIT 接続箱 遭難警報器
A
TNCP-NJ
TPA5FB0.4NJ5 12D-SFA-LITE-CV,100m,φ20: N-P-12DSFA IC-218 JUNCTION BOX DISTRESS ALERT/ *2 CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
FBA-5DFB,0.4m 8D-FB-CV,40/50m,φ14.3: N-P-8DSFA JUNCTION 17JE-23150 RECEIVED CALL UNIT
IC-318 TTYCSLA-4(*1) OR
5D-FB-CV,30m,φ10.7: N-P-5DFB -02(D8C) 2m CO-0.2x5P(*2), MAX.50m IC-305 IC-318
Vcc(ALM) 1 1 1 VCC 選択 TTYCSLA-1(*1) OR INMARSAT No.1/2
ANT P CO-0.2x2P(*2)
GND 2 2 2 GND SELECT 3 1 TR-A
TP5FBAW-5DFBB,30m,φ7.7 TD/RD-A 3 3 3 TD/RD-A 4 2 TR-B アラームユニット
TD/RD-B 4 4
P
4 TD/RD-B 3 FG ALARM UNIT
NC 5 5 TTYCSLA-1(*1) OR 5 GND IC-350
DGPS CO-0.2x2P(*2) アラームシステム
BNC ALM-H 6 6
DGPSデコーダー COAX. CABLE(50Ω) ALM-C 7 7 TTYCSLA-1(*1) OR ALARM SYSTEM
DGPS DECODER RD-A 8 8
CO-0.2x2P(*2) 航法装置 保安警報発呼器
USB RD-B 9 9 NAV EQUIPMENT SSAS ALERT UNIT
A TYPE IC-307 *2 *3 *4 IC-307(No.2) IC-307(No.3)
GND 10 10
キーボード 1.5m 4
TTYCSLA-4(*1) OR CO-0.2x5P(*2)
KEYBOARD SSAS_OUT-H 11 11 1 SSAS_OUT-H 1 *2 *3 *4 1 *2 *3
SSAS_OUT-C 12 12 2 NC 2 2
P P P
SSAS_CHECK 13 13 3 SSAS_CHECK 3 3
SSAS_IN-C 14 14 4 SSAS_IN-C 4 4
17JE-23250 P P P
PRINTER SSAS_CTRL 15 15 5 SSAS_CTRL 5 5
RH12BPG-3S プリンタ 57-3036 -02(D8C)
6 GND 6 6
VCTF-0.75x3C,5m,φ7 3
PRINTER 36
16S0184 25
24 VDC (+) アカ RED PP-520 *2
(-) クロ BLK (16S0084) 3m,φ8 *1
B GND シロ WHT または OR IV-2sq. 最大3台まで接続可能
H230817-1(*2) LAN RJ45 MAX. 3 UNITS AVAILABLE.
*1 *1 TTYCSLA-4(*1) OR
防水仕様ケーブル 8
STP(CAT5) パソコン/HUB CO-0.2x5P(*2)
WATERPROOF CABLE
12 VDC DC/DCコンバータ PC OR HUB 合計 :最大200m
DC/DC CONVERTER TOTAL: UP TO 200m
15A(12V) DC IN
7A(24V) MJ-A3SPF
MJ-A3SPF0018-050Z
12-24VDC シロ WHT 1 DC+
5m,φ11
クロ BLK 2 DC-
3 GND
100-115/ *1
200-230 VAC DPYC-2.5
1φ,50/60Hz AC AC/DC 24VDC + 防水仕様ケーブル
*1 IN 銅板 接続箱
電源ユニット OUT - COPPER STRAP IC-218 WATERPROOF CABLE
24 VDC DPYC-4 + DC AC/DC POWER JUNCTION BOX
W=30,1.2m *2
- IN SUPPLY UNIT JUNCTION XM-FD-361,2m IC-318
E PR-240 *2 1 アオ BLU 1
PE *1 2 チャ BRN 2
IV-2sq. 3 ムラサキ PPL 3
保護アース 4 ハイ GRY 4
5 5
C 6 ミドリ GRN 6
7 キ YEL 7
8 ダイ ORG 8
9 モモ PNK 9
10 ウスミドリ L-GRN 10
11 シロ/クロ WHT/BLK 11
12 シロ/アカ WHT/RED 12
13 クロ BLK 13
14 アカ RED 14
15 ミズ L-BLU 15
D
注記
*1)造船所手配。
*2)オプション。
*3)終端のIC-307はジャンパー設定を変更する。 DRAWN TITLE
*4)SSAS仕様のとき標準構成。 1/Feb/2019 T.YAMASAKI FELCOM 18
CHECKED 名称
NOTE 1/Feb/2019 H.MAKI インマルサット-C 船舶地球局
*1: SHIPYARD SUPPLY. APPROVED
6/Feb/2019 H.MAKI 相互結線図
*2: OPTION.
SCALE MASS NAME
*3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 kg INMARSAT-C MES
*4: STANDARD CONFIGURATION FOR SSAS. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No. REF.No.
C5674-C01- H 16-023-3001-1 INTERCONNECTION DIAGRAM