THE NEW D-300 MK2

The D-300 MK2 is a cost effective


modular genset controller ready
for internet monitoring through
plug-in modules.

FEATURES PLUG-IN MODULES


• Diesel and gas genset support • Battery back-up real time clock • GSM Modem (2G-3G-4G)
• 400Hz operation support • Idle speed control • Ethernet 10/100Mbits
• 400 event logs, full snapshot • Battery charge run enabled • Wi-Fi (802.11 b/g/n)
• All parameters front panel • Combat mode support • RS-485 (2400-57600baud)
editable • Multiple nominal conditions • RS-232 (2400-57600baud)
• 3 level configuration password • Contactor & MCB drive
• 128x64 graphical LCD display • 4 quadrant genset power FUNCTIONALITIES
• Downloadable languages counters
• Waveform display of V & I • Mains power counters • AMF unit
• Harmonic analysis of V & I • Fuel filling counter • ATS unit
• 16Amp MCB & GCB outputs • Fuel consumption counter • Remote start controller
• 8 configurable digital inputs • Modem diagnostics display • Manual start controller
• 6 configurable digital outputs • Configurable through USB, • Engine controller
• 3 configurable analog inputs RS-232 and GPRS • Remote display panel
• Both CANBUS-J1939 & MPU • Free configuration program
• 3 configurable service alarms • Allows SMS controls TOPOLOGIES
• Multiple automatic exerciser • Ready for central monitoring
• Weekly operation schedule • Mobile genset support • 3 ph 4 w, star & delta
• Dual mutual standby with • Automatic GSM geo-location • 3 ph 3 w, 2 CTs
equal aging of gensets • GPS connectivity (RS232) • 2 ph 3 w
• Manual “speed fine adjust” on • Easy USB firmware upgrade • 1 phase 2 wires
selected ECUs • IP65 rating with optional gasket
• Automatic fuel pump control
COMMUNICATION
• Disable protections feature MEASUREMENTS • USB Device
• Excess power protection • J1939-CANBUS
• Mains & genset PN/PP voltages
• Reverse power protection • Geo-locating through GSM
• Mains & genset frequency
• Overload IDMT protection • Internet Central Monitoring
• Mains & genset phase currents
• Load shedding, dummy load • SMS message sending
• Mains & genset neutral currents
• Multiple load management • E-mail sending
• Mains & genset, phase & total,
• Current unbalance protection • Free PC software: Rainbow Plus
kW, kVA, kVAr, pf
• Voltage unbalance protection • Modbus RTU (2400-57600baud)
• Engine speed
• Fuel filling & fuel theft alarm • ModbusTCP/IP
• Battery voltage
• HTML
• UDP
PLUG-IN MODULES
USB

Backpanel view
Plug-in modules

SCOPEMETER & HARMONICS RAINBOW PLUS PROGRAM

USB

RAINBOW SCADA CENTRAL MONITORING

Fleet Display on Map, online monitoring Smartphone Support


COMMUNICATIONS

ho

TECHNICAL SPECIFICATIONS
Alternator voltage: 0 to 300 V-AC (Ph-N) IP Protection: IP65 from front panel, IP30 from the rear
Alternator frequency: 0-650 Hz. (with gasket)
Mains voltage: 0 to 300 V-AC (Ph-N) Dimensions: 180 x 140 x 46mm (WxHxD)
Mains frequency: 0-600 Hz. Panel Cut-out Dimensions: 151 x 111 mm minimum.
Topology: 1-2-3 phases, with or without neutral Weight: 300 g (approx.)
DC Supply Range: 8.0 to 36.0 V-DC. Case Material: High Temperature, non-flammable
V-A-cos Accuracy: 0.5% + 1 digit ABS/PC
kW-kVA-kVAr Accuracy: 1.0% + 1 digit Installation: Flat surface mounting on a Type 1 enclosure.
Current consumption: 180 mA-DC max @ 12V-DC Rear retaining plastic brackets.
Current Inputs: current transformers. ../5A or ../1A.
Digital inputs: input voltage 0 to 36 V-DC. CONFORMITY
Analog input range: 0-5000 ohms.
Mains and genset contactor outputs: 16Amps@250V EU Directives Conformity
DC Outputs: Protected mosfet semiconductor outputs, -2014/35/EC (low voltage)
rated 1Amp@28V-DC -2014/30/EC (electro-magnetic compatibility)
Cranking dropouts: survives 0V for 100ms. Norms of reference:
Magnetic pickup voltage: 0.5 to 50VAC. EN 61010 (safety requirements)
Magnetic pickup frequency: 0 to 10000 Hz. EN 61326 (EMC requirements)
Charge Alternator Excitation: 2W. UL & CSA Compatibility:
Display Screen: 2.9”, 128x64 pixels -UL 6200, Controls for Stationary Engine Driven
USB Device: USB 2.0 Full speed Assemblies (Certificate # - 20140725-E314374)
Operating temperature: -20°C to 70°C (-4 to +158 °F) -CAN/CSA C22.2 No. 14-13 – Industrial Control
Storage temperature: -40°C to 80°C (-40 to +176°F) Equipment
Maximum humidity: 95% non-condensing.
TYPICAL CONNECTIONS