Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

%

AUTHORITY INDEPENDENT ENGINEER : CONCESSIONAIRE : EPC SUBCONTRACTOR: PROJECT:


6-LANING OF NATIONAL CORRIDOR NH-19 FROM PANAGARH TO
PANAGARH PALSIT ROAD PVT. LTD PALSIT FROM KM. 521.120 TO KM. 588.870(TOTAL LENGTH 67.750
Adani Corporate HouseShantigram,S G Highway, ASHOKA BUILDCON Ltd.
Ahmedabad-382421, Gujarat, India KM) IN THE STATE OF WEST BENGAL UNDER BHARATMALA
PARIYOJANA TO BE EXECUTED ON BOT (TOLL) BASIS.

EPC CONTRACTOR: DESIGN CONSULTANT:

NATIONAL HIGHWAYS L. N. MALVIYA INFRA PROJECTS ADANI ROAD TRANSPORT Ltd.


Adani Corporate House
AUTHORITY OF INDIA GROUP PVT. LTD. Shantigram, S G Highway, SAMARTH Infraengg
Ahmedabad-382421, Gujarat, India Technocrats Private Limited
A1-1X2.0X2.0-0.00 TO 1.00M FILL A2-1X2.0X2.0-1.00 TO 2.00M FILL A3-1X2.0X2.0-2.00 TO 3.00M FILL A4-1X2.0X2.0-3.00 TO 4.00M FILL A5-1X2.0X2.0-4.00 TO 5.00M FILL A6-1X2.0X2.0-5.00 TO 6.00M FILL A7-1X2.0X2.0-6.00 TO 7.00M FILL A8-1X2.0X2.0-7.00 TO 8.00M FILL A9-1X2.0X2.0-8.00 TO 9.00M FILL
BAR SHAPE BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c BAR DIA mm SPACING/Nos. c/c
MKD
1 - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE
2 12 200 16 200 16 200 16 190 16 150 16 150 16 150 20 150 20 150
2a 12 200 12 200 12 200 16 190 16 150 16 150 16 150 16 150 20 150
3 12 100 12 100 12 100 12 95 12 75 12 75 12 75 12 75 16 150
3a - NOT IN USE - NOT IN USE 0 NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE 10 150
4 12 200 10 200 10 200 10 190 10 150 10 150 10 150 10 150 10 150
5 10 100 10 100 10 100 10 95 10 75 10 75 10 75 10 75 10 75
5a - NOT IN USE 0 NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE
6 - NOT IN USE 0 NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE - NOT IN USE
7 10 200 10 200 10 200 10 190 10 150 10 150 10 150 10 150 10 150
8 10 200 10 200 10 200 10 190 10 150 10 150 10 150 10 150 10 150
9 8 210 8 250 8 250 8 250 8 250 8 250 8 250 8 250 8 250
9a NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE
10 8 210 8 250 8 250 8 250 8 250 8 250 8 250 8 230 8 210
11 8 210 8 250 8 250 8 250 8 250 8 250 8 250 8 230 8 210
12 8 220 8 250 8 250 8 250 8 250 8 250 8 250 8 230 8 200
12a NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE NOT IN USE
13 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos.
14 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos. 10 2 x 4 Nos.
15 10 4 x 2 Nos. 10 4 x 2 Nos. 10 4 x 2 Nos. 10 4 x 2 Nos. 10 4 x 2 Nos. 10 4 x 2 Nos. 10 4 x 2 Nos. 10 4 x 2 Nos. 10 4 x 2 Nos.
16 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200
17 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200
18 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200
19 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200
20 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200 10 200
150 T-T 150 T-T 150 T-T
21 - - - - - - - - - - - - 8 8
250 L-L 250 L-L 8 250 L-L
22 150 T-T 150 T-T 150 T-T 150 T-T
- - - - - - - - - - 8 8 8
250 L-L 250 L-L 230 L-L 8 200 L-L

A1-1X2.0X2.0 A2-1X2.0X2.0 A3-1X2.0X2.0 A4-1X2.0X2.0 A5-1X2.0X2.0 A6-1X2.0X2.0 A7-1X2.0X2.0 A8-1X2.0X2.0 A9-1X2.0X2.0


DESIGN OF BOX CULVERT 0.00 TO 1.00M FILL 1.00 TO 2.00M FILL 2.00 TO 3.00M FILL 3.00 TO 4.00M FILL 4.00 TO 5.00M FILL 5.00 TO 6.00M FILL 6.00 TO 7.00M FILL 7.00 TO 8.00M FILL 8.00 TO 9.00M FILL

Clear Span 2m 2m 2m 2m 2m 2m 2m 2m 2m

Clear Height 2m 2m 2m 2m 2m 2m 2m 2m 2m

Width of Haunch 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m

Depth of Haunch 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m 0.15m

Thickness of fill over top slab 0m 1m 2m 3m 4m 5m 6m 7m 8m

Depth of Top Slab 0.3m 0.3m 0.3m 0.3m 0.3m 0.35m 0.35m 0.35m 0.35m

Depth of Bottom Slab 0.3m 0.3m 0.3m 0.3m 0.3m 0.35m 0.35m 0.35m 0.35m

Depth of External Vertical Wall 0.3m 0.3m 0.3m 0.3m 0.3m 0.35m 0.35m 0.35m 0.35m

Actual base pressure 11.94 T/m2 13.07T/m2 11.36T/m2 12.99 T/m2 14.72 T/m2 16.90T/m2 18.75 T/m2 20.63 T/m2 22.54 T/m2

AUTHORITY INDEPENDENT ENGINEER : CONCESSIONAIRE : EPC SUBCONTRACTOR: PROJECT:


6-LANING OF NATIONAL CORRIDOR NH-19 FROM PANAGARH TO
PANAGARH PALSIT ROAD PVT. LTD PALSIT FROM KM. 521.120 TO KM. 588.870(TOTAL LENGTH 67.750
Adani Corporate HouseShantigram,S G Highway, ASHOKA BUILDCON Ltd.
Ahmedabad-382421, Gujarat, India KM) IN THE STATE OF WEST BENGAL UNDER BHARATMALA
PARIYOJANA TO BE EXECUTED ON BOT (TOLL) BASIS.

EPC CONTRACTOR: DESIGN CONSULTANT:

NATIONAL HIGHWAYS L. N. MALVIYA INFRA PROJECTS ADANI ROAD TRANSPORT Ltd.


Adani Corporate House
AUTHORITY OF INDIA GROUP PVT. LTD. Shantigram, S G Highway, SAMARTH Infraengg
Ahmedabad-382421, Gujarat, India Technocrats Private Limited

You might also like