Download as pdf
Download as pdf
You are on page 1of 4
2a =a . —F Zeiss Pharma Ltd. Ref: ZPL/JK/P&M/979 Purchase Order Date: 18-07-2023, To: From: ‘Thermo lab Scientific Equipment’s Pvt Ltd. Zeiss Pharma Ltd. (Unit 1) ‘Thermo lab House, Plot No. 19, Vasai Municipal IGC, SIDCO, Phase 2, Samba, Ind. Area, Umela Road, Vasai - (West), Dist. Jammu, (J&K) Thane - 401207, Maharashtra, India. PH: - 7696010152 GST: 27AAACT2830Q1Z0 il: - vinij@zpharma.co in E-Mail : sales-north@thermolabscientific.com PAN No: AAACZ7511N Kind Attn: Sujit Raut {9860096437} Sub: Purchase Order for (As per description) Dear Sir, ‘This has reference to your offer and further discussions we had with you. We are pleased to place our Purchase Order with you as detailed below: SPECIFICATIONS ‘THERMOLAB B.0.D INCUBATOR With PLC Control System (TB 1000 G) Material of Construction: Inside Stainless Steel and Outside Mild Steel Powder Coated or Stainless Steel. Insulation: PUF Insulation. Air Circulation: Uniformity under chamber loaded condition. Observation Door: Observation glass door inside with neoprene gasket. Heating System: U shaped SS. Nichrome wire air heaters. Refrigeration System: Compressor with CFC Free R134A / R404A / R407C (Eco Friendly) refrigerant. Complete with Compressor, Condenser, Evaporator and Other Accessories with Gas Charging. Control System: PLC control system with touch screen display, Human Machine Interface (HMI) Storage facility upto 1440 readings logged at 1 minute interval. Chamber readings, Data logger readings, events, Audit trail, Door access details. ‘Auto change over Main sensor: In case if main sensor opens, provision for automatic change-over to stand by sensor. ‘Auto start: In case of power failure (Main as well as UPS), chamber starts automatically once power resumes. User Levels / Rights & Password Protection: Three level operation, Admin, Master & General with fixed access rights. Access control according to authority level and Separate pass word for individual user. Software Compatibility: 21 CFR Part 11 compliant Stability Control System software (SCS) Safety Features: * Additional safety thermostat to cut off the supply in case of overshoot of temperature. Compressors ‘ON’delay time of 2 min. to safe guard the compressor. * MCB for over current protection + Safety controller sensor to cut off the supply in case of overshoot and undershoot of Temperature giving audio visual alarm. Other: Castor wheels, Adjustable Tray Height Arrangement, Lock and key arrangement Power :230 V AC single phase 50 Hz P&M/621 = FT Zeiss Pharma Ltd. Refi ZPL/JK/PEM/979 Purchase Order Date: 18-07-2025, Pre-Installation Requirement + Chamber to be installed in an air-conditioned room OR in well ventilated room having fresh air inlet and ‘exhaust fan. (Room Temperature should be below 30°C) * Drain line to be provided at 2 Inches above the floor level. + Recommended to install the chamber 2 ft. away from the back wall and 1 ft. away from all sides. + Stabilized 230 V AC Single Phase 20A power supply to the floor mounted chambers with MCB and proper Farthing. + UPS for control system upto 1 KVA GMP Model : Inside $5 304 & Outside SS 304. Temperature Range: 20°C to 60°C Control Accuracy (Temperature): #0.2°C ‘Temperature Uniformity: +2.0°C ‘SPECIFICATIONS ‘THERMOLAB B.0.D INCUBATOR With PLC Control System (TB 2000 G) Material of Construction: Modular Prefabricated insulated panels with cam & lock arrangement Insulation: PUF Insulation Air Processing Unit (APU): Designed to achieve optimum energy utilization with integrated cooling and heating. Air Processing Unit (APU): The air flow is designed to have uniform conditions throughout the chamber. Door: Leak proof door with positive sealing and locking system with vacuum sealed double pane observation window. Heating System: U shaped SS. Nichrome wire air heaters. Hydronic Refrigeration system (Chilled Water Refrigeration system) +A unique chilled water circulation system which reduces the electrical consumption by 60%. Chilled water Refrigeration system called as Hydronic system with Compressor having CFC free refrigerant. *Compact plug and play design and can be placed behind thechamber or in the technical area. * Compressor life increases as running time of compressor enormously decreases. Factory Assembled refrigeration sytem, avoiding onsite piping work. + Faster recovery of condition when the door is opened. +Prolonged stable condition even during power outage. * This unique design enables maintenance of optimum cooling coil temperatures depending on the chamber conditions and resultant Dew Point. Control System Data Storage facility upto 1440 readings logged at 1-minute interval. Chamber readings. Data Logger readings, events. Audit trail, Door Access details. Email Alert System +Ethernet communication protocol. PLC based control system with colored Touch Screen Display (HIMI) *Provision to do system setting, temperature control, system reset, SMS selection. Auto change over Main sensor: In case if main sensor opens, provision for automatic change over to stand bby sensor. P&M/621 Zeiss Pharma Ltd. Ref: ZPL/JK/P&M/979 Purchase Order Date: 18-07-2023 Stand By Refrigeration System Price Inclusion [TB 1000: 4 Point Temperature Scanners Complete with Sensors and Data Logging Facility : Security Alarm System. PLC control system and HMI display with data storage up to 1440 readings. LAN based communication protocol Audio visual alarms Stainless steel trays Safety Devices for temperature (overshoot and undershoot) roe Validation will be done for main system for 24 hours unloaded condition and 24 hhours loaded condition. and standby system for 24 hours unloaded condition and 24 hours loaded condition. ‘Note: ‘The above BOD’s will connect with our existing software version - 1.3 lite, NOTE: Operating manual and IQ, OQ and PQ documents (Soft Copy) along with Material Test Certificates and Calibration Certificates. ’ Factory calibrated three conditions with traceable certificate of NABL ‘Validation will be done for main system for 24 hours unloaded condition and 24 hours loaded condition. and standby system for 24 hours unloaded condition and 24 hours loaded condition. MODEL (6) cuFT/UTRs, panare |e weoswssal (eas | iin TB 1000 G Tay See W xD 34/1000 800 x 800 x 1570 | 950 x 1265 x 2190 | 667000.00 | 350000.00 ‘mum: 765 x 750 (Number of Trays: 6) TB20G * Number of Racks: 2 1.945 x 1.11 x Meas thar 2,000 1.785 x 0.95 x L.64 eS 892000.00 | 475000.00 18) Door Access security system to restrict unauthorized access. poe | Ein on (only for main doo) y y Total | 840000.00 Tess Existing Hydronic System = 775000.00 Grand Total | 7,65,000.00 GST 18% |_1,37,700.00 Grand Total | 9,02,700.00 P&M/621 (t) Zeiss Pharma Ltd. Ref: ZPL/JK/P&M/979 Purchase Order Date: 18-07-2023 8. GST 18% Included, Packing & Forward: Included Payment Terms: 40% advance with PO, 50% against Proforma Invoice, 10% after successful Installation. Delivery Time: within 21 Days ( Urgent requirement ) Freight Charges: Extra as actual. Warranty 12 months from the date of successful Installation & Commissioning. Documentation: Thermo lab will provide IQ, OQ, PQ documents with Material Test Certificates and Calibration Certificates. Other Terms and conditions as per Quotation Ref : NH QT/2023 24/103/1, Date: 14.07.2023 ‘Rupees: Nine Lacs Two Thousand Seven Hundred Only For: Zeiss Pharma Ltd P&M/621

You might also like