AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

This is a quick reference guide for the AirScale Indoor Radio (ASiR) System 4G ASiR Pico Remote Radio
Head (ASiR-pRRH) installations.
The 4G ASiR-pRRH is designed for indoor installations on walls or ceilings.

Check the site Prepare for installation Installation Cabling

Contents of Preparing the Connecting


1 delivery 2 installation 3 Wall installation 5 cables

Compliance Device information


Compliance 4 Ceiling installation

Compliance
7
6 statements 7 Specifications
Nokia is committed to diversity and inclusion. We are continuously reviewing our customer documentation and consulting with standards bodies to

No further reproduction or networking is permitted. Distributed by Nokia.


Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
ensure that terminology is inclusive and aligned with the industry. Our future customer documentation will be updated accordingly.

This document includes Nokia proprietary and condential information, which may not be distributed or disclosed to any third parties without the
prior written consent of Nokia. This document is intended for use by Nokia’s customers (“You”/”Your”) in connection with a product purchased or
licensed from any company within Nokia Group of Companies. Use this document as agreed. You agree to notify Nokia of any errors you may nd in
this document; however, should you elect to use this document for any purpose(s) for which it is not intended, You understand and warrant that any
determinations You may make or actions You may take will be based upon Your independent judgment and analysis of the content of
this document.

Nokia reserves the right to make changes to this document without notice. At all times, the controlling version is the one available on Nokia’s site.

No part of this document may be modied.

NO WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF AVAILABILITY, ACCURACY,
RELIABILITY, TITLE, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RELATION TO THE CONTENT OF
THIS DOCUMENT. IN NO EVENT WILL NOKIA BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL
OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT, EVEN IN THE CASE OF ERRORS IN OR OMISSIONS FROM THIS
DOCUMENT OR ITS CONTENT.

Copyright and trademark: Nokia is a registered trademark of Nokia Corporation. Other product names mentioned in this document may be
trademarks of their respective owners.

© 2021 Nokia.

Important Notice on Product Safety

This product may present safety risks due to laser, electricity, heat, and other sources of danger.

Only trained and qualied personnel may install, operate, maintain or otherwise handle this product and only after having carefully read
the safety information applicable to this product.

The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this
document or documentation set.

Nokia is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you to join us in
working towards a cleaner and safer environment. Please recycle product packaging and follow the recommendations for power use and proper
disposal of our products.

Should you have any questions regarding our Environmental Policy or the environmental services we offer, please contact us at Nokia for any
additional information.

Issue 08, Approved on 2020-03-16, DN222163026


No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

Before you start


This guide provides instructions on 4G ASiR-pRRH installation. The 4G ASiR-pRRH unit is designed
to be installed indoor on walls or ceilings.

Only trained and qualified personnel familiar with electronics may install, operate, maintain or
otherwise handle this product and only after having carefully read the safety information
applicable for this product.

Electrostatic discharge (ESD) can damage the product. Wear an ESD wrist strap or use a
corresponding method when handling the product.

The operating temperature range of the device is between 0°C (32°F) and 40°C (104°F).

50 Provide 50 mm (2.0 in.) clearance on all sides of the unit to ensure proper air flow and heat
mm dissipation.

The unit should be located away from any RF radiation sources.

Avoid installing the device near windows to minimize external interference. The unit should be
located out of direct sun exposure.

Installation in dusty environments will eventually lead to hardware failures, such as shorts on the
unit, and clogged or blocked fans. The unit must be located away from areas of potential salt spray.

The unit must be mounted away from air conditioning, or potential sources of dripping liquids.

Shielded cables (F/UTP or better grade like U/FTP and F/FTP) must be used for 4G ASiR-pRRH and
ASiR-sHUB connection.

This product must only be used with Power-over-Ethernet (PoE++ IEEE802.3bt type 3). Prior to
installation, verify if the correct PoE infrastructure is in place, especially when replacing other
hardware with this product. Power-over-Ethernet (PoE) cables must only be connected to Safety
Extra Low Voltage (SELV) circuits and must not be routed outside the building structure.

-3-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

1 Contents of delivery
Items provided in the delivery

1 x 4G ASiR-pRRH unit 1 x Mounting bracket

AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

This is a quick reference guide for AirScale Indoor Radio (ASiR) System 4G ASiR Pico Remote Radio
Head (ASiR-pRRH) installations.
The 4G ASiR-pRRH is designed for indoor installations on walls or ceilings.

Compliance Device information

6 7

1 x Ceiling clip 1 x AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

1 x Plastic bag containing:


4 x M3x10 screws,
1 x M3 security screw

Items

1 x 4G ASiR-pRRH unit

1 x AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

1 x Mounting bracket

1 x Ceiling clip

1 x Plastic bag containing: 4 x M3x10 screws, 1 x M3 security screw

-4-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

2 Preparing the installation


Installation tools and materials

1 x Phillips screwdriver (PH2) 1 x Tx10 Security screwdriver 1 x Impact drill

1 x Cable lock or padlock


1 x Pencil 1 x Level
(optional)

-5-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

2 Preparing the installation


Clearances

Note:
50 The 50 mm (2.0 in.) is the recommended minimum clearance. The front side of the 4G ASiR-pRRH
mm should be facing open space to maximize device efficiency.

Dimensions and weight

Property Value

Height 210 mm (8.27 in.)

Width 210 mm (8.27 in.)

Depth 50 mm (2.0 in.)

Weight 2 kg (4.41 lb)

-6-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

3 Wall installation
Installing 4G ASiR-pRRH onto walls

1. Mark four screw holes on the designated wall. Make 2. Drill holes in the marked places.
sure that the mounting bracket is leveled.

3. Secure the mounting bracket onto the wall with four 4. Connect the PoE cable to the 4G ASiR-pRRH (see
screws. Tighten the screws according to the wall Chapter 5: Connecting cables). Place the unit on the
mount hardware manufacturer’s instructions. Make bracket.
sure that the bracket is secure and immovable.

-7-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

3 Wall installation
Installing 4G ASiR-pRRH onto walls

5. Put four M5 screws (attached to the back of the unit) through the holes
in the bracket. Slide the unit down (a) and tighten the M5 screws (b) using
the Phillips screwdriver.

Note:
The mounting screw and anchor hardware are not included in the delivery. Make sure to
select appropriate mounting screw and anchor hardware specific to your installation surface.

6. Tighten the M3 security screw with TX10 security screwdriver at the top
of the unit to secure it.

Checklist
The unit is attached to the mounting bracket and cannot slide off the mounting.

-8-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

4 Ceiling installation
Installing 4G ASiR-pRRH onto a ceiling grid

1 2

1. Expand the ceiling clip to the maximum width. 2. Lift the ceiling clip to the ceiling grid.

3. Compress the clip and tighten to the grid with the


four screws.

Note:
The mounting screw and anchor hardware are not included in the delivery. Be sure to select
appropriate mounting screw and anchor hardware specific to your installation surface.

-9-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

4 Ceiling installation
Installing 4G ASiR-pRRH onto a ceiling grid

4.1 4.2

4. Lift the mounting bracket to the ceiling clip (4.1) and tighten it to the clip with four M3 screws (4.2).

5 6

5. Connect the PoE cable to the 4G ASiR-pRRH (see 6.Tighten the M3 security screw at the top of the
Chapter 5: Connecting cables). module to secure the 4G ASiR-pRRH unit.
Lift the unit and attach it to the bracket by putting the
screws at the back of the unit through the holes. Slide
down the 4G ASiR-pRRH to secure it.

Make sure the ceiling grid location is well


supported.

7. Optional: Secure the module with a cable lock, using the slot with a padlock icon ( ) on the side of the device.

-10-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

5 Connecting cables
Cabling 4G ASiR-pRRH with Power over Ethernet (PoE)

1. Connect a shielded PoE cable to the PoE port of the 4G ASiR-pRRH.

Note:
The 4G ASiR-pRRH unit can be installed with Cat.5e or Cat.6A shielded PoE cable. The Cat.6A
cable is preferred for later support for 5G ASiR-pRRH deployments.

4G ASiR-pRRH RF port locations

Note:
Main and diversity external antenna cable connections are required for the 4G ASiR-pRRH
variants with external antenna interface.

Main antenna port for


Diversity antenna port the second RF module
for the first RF module

Diversity antenna port Main antenna port for


for the second RF module the first RF module

Checklist
Lock is in place.
Unit is powered on (LED status green).

-11-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

6 Compliance statements
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept any interference received, including interference that may
cause undesired operation.

This equipment has been tested and complies with the Class B digital device limits, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used according to the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
cannot occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
taking one of the following actions:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and the receiver.
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.

FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority
to operate this equipment. RF Modules installed in this product must not be co-located or operating in conjunction with any
other antenna or transmitters, except when installed in accordance with FCC multi-transmitter product guidelines.

FCC Radiation Exposure Statement


This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environments. This equipment
should be installed and operated in accordance with the minimum distance found in the 4G ASiR-pRRH model list and
compliance boundaries table in AirScale Indoor Radio System 4G ASiR-pRRH Product Description (DN250936526)
document.

ISED Compliance Statement


Note: Industry Canada has been renamed Innovation, Science, and Economic Development Canada (ISED) following the issue
of RSP-100 Issue 11 and DC-01 Issue 06. Equipment certifications previously issued by Industry Canada remain valid and do
not require updating. Meaning you may see the names used interchangeably in documentation.

The following statement is applicable to 4G ASiR-pRRH which has Innovation, Science and Economic Development (ISED)
approval:
This device complies with ICES-003 of Industry Canada’s license-exempt RSSs.
Operation is subject to the following two conditions
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme a la nomre ICES-003 du CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes:
1. L'appareil ne doit pas produire de brouillage.
2. L'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si lebrouillage est susceptible d'en
compromettre le fonctionnement.

-12-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

6 Compliance statements
CE Marking

The equipment described in this document faithfully complies with: European Union Radio
Equipment Directive (RED) 2014/53/EU.

The Declaration of Conformity is provided to customers with other technical documents upon
request and is accessible from https://online.networks.nokia.com to authorized users.

Radiation exposure statement


This equipment complies with radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator and your body.

RED 2014/53/EU Article 10 Compliance

RED 2014/53/EU requires that for products which could potentially have an issue with a non-harmonized frequency in a
specific EU country, the product documentation must list the restrictions, and the packaging must carry a label reflecting
that country’s code.

Restrictions in
AT BE BG HR
CY CZ DK EE
FI FR DE EL
HU IE IT LV
LT LU MT NL
PL PT RO SK
SI ES SE UK

Label example for a product carrying a non-harmonized Frequency restriction.

EU RoHS statement

This equipment complies with the European Union RoHS Directive 2011/65/EU on the restriction of the use of certain
hazardous substances in electrical and electronic equipment. The directive applies to the use of lead, mercury, cadmium,
hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) in electrical and
electronic equipment.

-13-
No further reproduction or networking is permitted. Distributed by Nokia.
Copyrighted material licensed to howard.yang@nokia.com on 09-01-2024.
AirScale Indoor Radio System 4G ASiR-pRRH Quick Guide

7 Specifications
4G ASiR-pRRH physical specification

Items Description

Dimensions 210 mm x 210 mm x 50 mm (8.27 in. x 8.27 in. x 2.0 in.)

Weight 2 kg (4.41 lb)

4G ASiR-pRRH electrical specification

Items Description

Power input PoE++ (IEEE802.3bt type 3)

Power consumption ≤ 39 W

4G ASiR-pRRH environmental specification

Items Description

Working temperature 0°C to 40°C

Operating humidity 5% to 93%

Dustproof and waterproof IP 20