Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

ME MB 3

The efficient solution for the OR

www.klsmartin.com
ME MB 3 – The efficient
solution for the OR.
Innovation: cost-efficient and user-friendly

The HF surgical unit


ME MB 3 from KLS Martin
The efficient solution for the OR

With its ME MB 3, KLS Martin presents an HF surgical unit that


utilizes proven technology for the best ergonomics and handling.
Power setting is conveniently done with a rotary knop. The
required current type can be selected easily on the front side.

A high standard of patient safety, a straightforward design


and superior application versatility round off a user-friendly profile.
Yet a special highlight is still to mention, as different connecting
sockets are available to ensure that you can continue to use your
existing accessories.

In short, the KLS Martin ME MB 3 is the efficient solution


for your OR.

3
KLS Martin electrosurgical unit: ME MB 3

KLS Martin electrosurgical unit


The main features

1 2 3 4 5

6 7 8 9 10

10 11 12 13 14

15 16 17 18 19

20 21 22 23 24

25 26 27 28 29

Display Functional test 30 31 32 33 34

Power setting constantly under visual control Each time the unit is turned on, the KLS Martin
1 2 3 4 5 1 2 3 4 5
ME MB 3 performs a self-test. If an error or
6 7 8 9 10 6 7 8 9 10
High patient safety thanks to PCS NE monitoring malfunction is detected, no acknowledgement
10 11 12 13 14 10 11 12 13 14
(Patient Control System) signal is emitted and HF current output is auto-
1 2 3 4 5
15 16 17 18 19
In high-frequency surgery, the thermal effect matically blocked. This ensures that the KLS
15 16 17 18 19

6 7 8 9 10
must be strictly limited to the point 20
of application
21 22 23 24 Martin ME MB 3 can be used 20 only
21 under
22 perfect
23 24
10 11 12 13 14
of the active electrode. In other words,25 no26 heat
27 28 29
operating conditions. 25 26 27 28 29
15 16 17 18 19
must be allowed to develop underneath the
30 31 32 33 34 30 31 32 33 34
neutral electrode (NE). To ensure 20
this,
21
HF22
units
23 24
Monopolar handle connections
from KLS Martin are equipped with 25 NE
26 monitoring
27 28 29 In the “m” version, the KLS Martin ME MB 3
1 2 3 4 5
functions designed to keep the neutral electrode allows you to connect handles with a KLS Martin
30 31 32 33 34 6 7 8 9 10
under constant control, blocking monopolar HF plug or a US 3-pin plug. The “i” version, in turn,
10 11 12 13 14
energy output as soon as an NE problem occurs is designed for connection of monopolar handles
15 16 17 18 19
due to lack of skin contact. A split neutral elec- with Bovie plug or US 3-pin plug.
trode is required for this function. 20 21 22 23 24

The KLS Martin HF accessories


25 26 program
27 28 offers
29

The PCS system, in fact, continuously monitors you a wide selection of handles for various appli-
30 31 32 33 34
correct attachment of the NE to the patient’s cations. For details, please refer to our special
skin. If the NE detaches in any way, the user HF Accessories Catalog.
is immediately alerted – well before critical
situations could arise.

ME MB 3, “m” version ME MB 3, “i” version


for KLS Martin accessories for international accessories

4
1 2 3 4 5

6 7 8 9 10

10 11 12 13 14 1 12 23 34 45 5 1 2 3 4 5

15 16 17 18 19 6 67 78 89 910 10 6 7 8 9 10

10 1011 1112 1213 1314 14 10 11 12 13 14


20 21 22 23 24

15 1516 1617 1718 11819 219 3 4 5


15 16 17 18 19
25 26 27 28 29
6 7 8 9 10
20 2021 2122 2223 2324 24 20 21 22 23 24
30 31 32 33 34 10 11 12 13 14
25 2526 2627 2728 2829 29 25 26 27 28 29
15 16 17 18 19

30 3031 3132 3233 3334 34 30 31 32 33 34


20 21 22 23 24

25 26 27 28 29

30 31 32 33 34

Progressive power adjustment Bipolar ON/OFF automatic function


1 2 3 4 5
This function allows you to adjust the power Button for bipolar coagulation with automatic
1 2 3 4 5 6 7 8 9 10
output precisely to your specific needs when start/stop function in manual operation using
6 7 8 9 10 10 11 12 13 14
working in the lower power range. This is parti- the handle. With this function, bipolar safety
10 11 12 13 14 15 16 17 18 19
cularly useful for the hemostatic treatment coagulation is automatically performed as
soon as the electrodes make tissue contact.
15 16 17 18 19
of delicate vessels, for example. In the upper 20 21 22 23 24

range, however, the 20 ME 21 MB22 3 provides


23 24 a The pulse-type follow-up coagulation
25 26 27 phase
28 29

steadily increasing 25
power
26
output.
27 28
It is
29
this high ensures the best possible coagulation result.
30 31 32 33 34
“power reserve” that warrants the universal
30 31 32 33 34
applicability of the KLS Martin ME MB 3.

Monopolar cutting and coagulation1 2 3 4 5


using the foot switch
6 7 8 9 10

10 11 12 13 14
The double-pedal foot switch (for cutting/
15 16 17 18 19
coagulation) can be used for monopolar
as well as bipolar operation. 20 21 22 23 24

25 26 27 28 29

30 31 32 33 34
Bipolar coagulation with the foot switch Multifunctional connector
1 2
for bipolar
3 4
instruments
5
1 2 3 4 5
The power spectrum of the KLS Martin ME MB 3 This is a bipolar combination socket for active
6 7 8 9 10 6 7 8 9 10
is rounded off by the “Bipolar Coagulation” electrodes, allowing you to connect the small
10 11 12 13 14 10 11 12 13 14
option used in conjunction with the foot switch. coaxial plug (KLS Martin standard) or interna-
15 16 17 18 19 15 16 17 18 19
This reliable bipolar coagulation function from tional accessories from other manufacturers.
KLS Martin allows you to combine20
high-precision
21 22 23 24 20 21 22 23 24

work with large-volume yet safe25 coagulation.


26 27 28 29 25 26 27 28 29

30 31 32 33 34 30 31 32 33 34

5
KLS Martin electrosurgical unit: ME MB 3

KLS Martin electrosurgical unit


Types of current

m “m” version, ME MB 3
for KLS Martin accessories

i “i” version, ME MB 3
for international accessories

Monopolar Cut 1 (Pure Cut) 1 2 3


ENDO4
Mode
5 1 2 3 4 5

for a smooth cut with minimal eschar formation.6 7 8


This9
is a
10
time-controlled cutting6
mode
7
offering
8 9 10

This so-called “pure cut” comes closest to the10 11 12


a fractionated
13 14
and therefore controlled
10 11
cut
12
inten-
13 14

classic scalpel cut, thus providing the best basis ded for special applications, e.g. for endoscopic
15 16 17 18 19 15 16 17 18 19
for effective wound healing. papillotomy and endoscopic polypectomy.
20 21 22 23 24 20 21 22 23 24

25 26 27 28 29 25 26 27 28 29

30 31 32 33 34 30 31 32 33 34

Monopolar Cut 2 (Blend Cut) 1 2 3 4 5

for a pure cut with some more eschar formation


6 7 8 9 10

compared to pure cut. 10 11 12 13 14

15 16 17 18 19

20 21 22 23 24

25 26 27 28 29

30 31 32 33 34

Monopolar Cut 3 (Super Blend Cut)1 2 3 4 5 Power Peak – the power boost 1 2 1 3 21 4 32 5 4

Super Blend is a cutting current with6 even 7 8 9 10


for “cutting under water” 6 7 6 8 76 9 87 10 9

stronger eschar formation compared 10


to 11
Blend
12 13 14
This function provides an increased HF power 10 1110 121110 131211 141

Cut. As the wound edges are simultaneously


15 16 17 18 19
level to facilitate starting the cut. It is intended
15 1615 171615 181716 191

coagulated during the cutting process, bleeding for use in urology/gynecology (cutting in liquid
20 21 22 23 24 20 2120 222120 232221 242
from dissected capillary vessels is stopped at environments*)
once and extended hemorrhages are25 prevented.
26 27 28 29 25 2625 272625 282726 292

30 31 32 33 34 30 3130 323130 333231 343

* Power Peak just when activationis carried out per foot switch

6
1 2 1 3 2 4 3 5 4 5

1 2 1 3 2 1 4 3 2 51 4 3 2 5 4 3 51 4 2 5 3 4 5 6 7 6 8 7 9 8 10 9 10

6 7 6 8 7 6 9 8 7 106 9 8 7 10 9 8 106 9 7 10 8 9 10 10 11 10 12 11 13 12 14 13 14

10 11 10 12 11 10 13 12 11 14
10 13 12 11 14 13 12 14
10 13 11 14 12 13 14 15 16 15 17 16 18 17 19 18 19

15 16 15 17 16 15 18 17 16 19
15 18 17 16 19 18 17 19
15 18 16 19 17 18 19 20 21 20 22 21 23 22 24 23 24

20 21 20 22 21 20 23 22 21 24
20 23 22 21 24 23 22 24
20 23 21 24 22 23 24
25 26 25 27 26 28 27 29 28 29

25 26 25 27 26 25 28 27 26 29
25 28 27 26 29 28 27 29
25 28 26 29 27 28 29
30 31 30 32 31 33 32 34 33 34

30 31 30 32 31 30 33 32 31 34
30 33 32 31 34 33 32 34
30 33 31 34 32 33 34

1 2 3 4 5

Monopolar Contact Coagulation1 2 3 4 5


Monopolar Spray Coagulation 6 7 8 9 10

Coagulation current with depth


6
effect
7 8
(electrode
9 10
Coagulation current for surface coagulation 10 11 12 13 14

in direct contact with the tissue). (fulguration). It is especially suited for hemostasis
15 16 17 18 19
10 11 12 13 14
during TUR procedures using small-surface
15 16 17 18 19 20 21 22 23 24
electrodes (e.g. loop electrodes).
20 21 22 23 24 25 26 27 28 29

25 26 27 28 29
30 31 32 33 34

30 31 32 33 34
1 2 3 4 5

Forced Prep 6 7 8 Bipolar


9 10Coagulation

Forced coagulation current enabling fast 10 11 12 KLS13 Martin


14 offers users a wide range of bipolar
coagulation. An ideal current for dissecting tasks
15 16 17 accessories:
18 19

because it provides effective cutting capability - marCut® instruments


20 21 22 23 24
despite its dominant coagulation feature. - nonStick-red-forceps
25 26 27
- nonStick-flush-forceps
28 29

30 31 32 - marLap
33 34 instruments
marCut®

nonStick flush

nonStick red

7
KLS Martin electrosurgical unit: ME MB 3

HF trolleys

maXium® smart Cart

8
HF trolley

9
Product range: Accessories for ME MB 3

Accessory sets and ordering information

smartPen

80-160-00-04 Standard Set A for ME MB 3, “m” version 80-140-00-04 Large Set of monopolar accessories for hand
(and other major HF units from KLS Martin) activation for ME MB 3, “m” version
80-701-35-04 1 Disposable electrode handles, SU = 25/pack 80-217-13-04 1 smartPen Electrode handle with two pushbuttons
80-344-09-04 1 Disposable DuoSafe neutral electrodes, for 4-mm electrodes, with KLS Martin plug
SU = 50/pack 80-342-07-04 1 Twin-Pad II neutral electrode with two contact
80-294-40-04 1 KLS Martin connection cable surfaces (split), contact surface 200 cm², without
for disposable neutral electrodes connection cable
80-505-00-04 1 Cleaning pad for electrodes, 80-373-00-04 1 Textile band with velcro strap, 100 cm,
sterile packed, SU = 100/pack washable at 60°C
80-811-30-04 1 Foot switch 80-416-00-01 1 Electrode container for 16 electrodes
80-505-00-04 1 Cleaning pad for electrodes,
sterile packed, SU = 100/pack
80-160-01-04 Standard Set B for ME MB 3, “i” version 80-510-06-04 1 Lancet electrode, straight, SU = 5/pack
80-221-02-04 1 Disposable electrode handles, SU = 10/pack 80-511-06-04 1 Lancet electrode, angled
80-344-09-04 1 Disposable DuoSafe neutral electrodes, 80-515-04-04 1 Knife electrode
SU = 50/pack 80-520-06-04 1 Needle electrode, SU = 5/pack
80-294-44-04 1 Valleylab connection cable 80-540-04-04 1 Wire loop electrode, Ø = 5 mm
for disposable neutral electrodes 80-542-06-04 1 Wire loop electrode, Ø = 10 mm
80-505-00-04 1 Cleaning pad for electrodes, 80-550-06-04 1 Ribbon loop electrode, Ø = 10 mm
sterile packed, SU = 100/pack 80-560-06-04 1 Ball electrode, Ø = 2 mm, SU = 5/pack
80-811-30-04 1 Foot switch 80-562-06-04 1 Ball electrode, Ø = 4 mm, SU = 5/pack

10
marCut®

Technical data
ME MB 3 nonStick red

nonStick flush

marLap

80-140-01-04 Large Set of monopolar accessories for foot 80-150-00-04 Set of bipolar accessories,
activation for ME MB 3, “m” version for ME MB 3, “m” version
80-220-02-04 1 smartPen electrode handle without pushbuttons 80-287-53-04 1 Connecting cable for bipolar forceps
for 4-mm electrodes, with KLS Martin plug 80-924-16-04 1 Bipolar forceps, straight, blunt, 16 cm/6 1⁄4"
80-342-07-04 1 Twin-Pad II neutral electrode with two contact 80-945-20-04 1 Bipolar forceps, bayonet-shaped, blunt, 20 cm/8"
surfaces (split), contact surface 200 cm², without 80-925-16-04 1 Bipolar forceps, angled, blunt, 16 cm/6 1⁄4"
connection cable 80-925-20-04 1 Bipolar forceps, angled, blunt, 20 cm/8"
80-373-00-04 1 Textile band with velcro strap, 100 cm, 80-924-20-04 1 Bipolar forceps, straight, blunt, 20 cm/8"
washable at 60°C
80-416-00-01 1 Electrode container for 16 electrodes
80-505-00-04 1 Cleaning pad for electrodes, 80-150-01-04 Set of bipolar accessories with nonStick red
sterile packed, SU = 100/pack forceps, for ME MB 3, “m” version
80-510-06-04 1 Lancet electrode, straight, SU = 5/pack 80-287-53-04 1 Connection cable for bipolar forceps
80-511-06-04 1 Lancet electrode, angled 80-986-17-04 1 Bipolar forceps, nonStick red,
80-515-04-04 1 Knife electrode straight, blunt, 16 cm/6 1⁄4"
80-520-06-04 1 Needle electrode, SU = 5/pack 80-992-20-04 1 Bipolar forceps, nonStick red,
80-540-04-04 1 Wire loop electrode, Ø = 5 mm bayonet-shaped, blunt, 20 cm/8"
80-542-06-04 1 Wire loop electrode, Ø = 10 mm 80-987-17-04 1 Bipolar forceps, nonStick red,
80-550-06-04 1 Ribbon loop electrode, Ø = 10 mm angled, blunt, 16 cm/6 1⁄4"
80-560-06-04 1 Ball electrode, Ø = 2 mm, SU = 5/pack 80-987-20-04 1 Bipolar forceps, nonStick red,
80-562-06-04 1 Ball electrode, Ø = 4 mm, SU = 5/pack angled, blunt, 20 cm/8"
80-830-00-04 1 Double-pedal foot switch, anti-explosive, 80-98­­6-20-04 1 Bipolar forceps, nonStick red,
with connection cable of 5 m straight, blunt, 20 cm/8"

11
Product range: Accessories for ME MB 3

Ordering information for


HF units and accessories

Ordering information

80-040-11-04 ME MB 3 electrosurgical unit, with mains cable,

m without accessories, KLS Martin (“m”) version,


220–240 V

80-040-12-04 ME MB 3 electrosurgical unit, with mains cable,

i without accessories, international (“i”) version,


220–240 V

12
Technical data
ME MB 3 from KLS Martin

ME MB 3 technical data
Power requirements 220–240 V, 50–60 Hz
Power input without HF output: approx. 26 VA

at max. power output: approx. 800 VA

Leakage currents LF and HF in compliance with IEC 60601-1 and 2-2
Nominal frequency 450 kHz
Modulation frequency 30 kHz

HF output power:
Type of current Power Crest factor Voltage

Cut 1 (pure) max. 400 W at 300 Ω 1.6 at 300 Ω max. 1,500 Vp

Cut 2 (blend) max. 300 W at 300 Ω 1.9 at 300 Ω max. 2,000 Vp

Cut 3 (super blend) max. 200 W at 300 Ω 2.4 at 300 Ω max. 1,600 Vp
Forced Prep max. 120 W at 200 Ω 4.9 at 200 Ω max. 2,100 Vp

Endo Mode max. 100 W at 200 Ω 1.6 at 200 Ω max. 1,200 Vp

Contact coagulation max. 250 W at 200 Ω 3.4 at 200 Ω max. 2,100 Vp
Spray coagulation max. 120 W at 300 Ω 5.6 at 300 Ω max. 4,400 Vp
Bipolar coagulation max. 100 W at 100 Ω 2.1 at 100 Ω max. 350 Vp
Line fuses 220–240 V: T 4 A (slow-blow)

Sound level HF current activation: 40 - 65 dB (adjustable)

Alarm: 65 dB(A)

Weight 8.6 kg

Interference suppression Limits in conformity with EN 55011
Interference immunity in conformity with IEC 801

Dimensions Width: 405 mm; height: 135 mm; depth: 380 mm

13
Service: information materials and catalogs

marVac®
maXium® smart Vac

4 Effective

4 Ergonomic

4 Safe

marVac®/maxium® smartVac –
the innovative system for efficient removal of surgical plume

Unobstructed view and maximum safety at the surgical site –


smoke is a thing of the past

For additional information on our marVac® and


maXium® smartVac smoke evacuation system,
please refer to our separate product brochures.

14
Should you have any queries …
… we’ll be glad to be at your service!

Our HF Accessories Catalog contains the


complete range of KLS Martin HF instruments.

You can reach us in person either via e-mail


or through our customer hotline.
E-mail: info@klsmartin.com
Hotline: ++49-7461-706-0

15
KLS Martin Group

KLS Martin Australia Pty Ltd. KLS Martin do Brasil Ltda. KLS Martin Medical (Shanghai) KLS Martin India Pvt Ltd.
Sydney · Australia São Paulo · Brazil International Trading Co., Ltd Chennai · India
Tel. +61 2 9439 5316 Tel. +55 11 3554 2299 Shanghai · China Tel. +91 44 66 442 300
australia@klsmartin.com brazil@klsmartin.com Tel. +86 21 5820 6251 india@klsmartin.com
info@klsmartin.com

KLS Martin Italia S.r.l. KLS Martin Japan K.K. KLS Martin SE Asia Sdn. Bhd. KLS Martin de México, S.A. de C.V.
Milan · Italy Tokyo · Japan Penang · Malaysia Mexico City · Mexico
Tel. +39 039 605 67 31 Tel. +81 3 3814 1431 Tel. +604 261 7060 Tel. +52 55 7572 0944
info@klsmartin.com info@klsmartin.com malaysia@klsmartin.com mexico@klsmartin.com

KLS Martin Nederland B.V. KLS Martin SE & Co. KG KLS Martin Taiwan Ltd. KLS Martin SE & Co. KG
Huizen · Netherlands Moscow · Russia Taipei · Taiwan Dubai · United Arab Emirates
Tel. +31 35 523 45 38 Tel. +7 499 792 76 19 Tel. +886 2 2325 3169 Tel. +971 4 454 16 55
infonl@klsmartin.com russia@klsmartin.com taiwan@klsmartin.com middleeast@klsmartin.com

KLS Martin UK Ltd. KLS Martin LP KLS Martin SE Asia Sdn. Bhd.
Reading · United Kingdom Jacksonville · Florida, USA Hanoi · Vietnam
Tel. +44 118 467 1500 Tel. +1 904 641 77 46 Tel. +49 7461 706-0
info.uk@klsmartin.com usa@klsmartin.com info@klsmartin.com

Do you know how to get all important information


about the KLS Martin Energy Devices?

Please download KLS Martin App Energy Devices!


The App is available for Android and iOS.

https://itunes.apple.com/de/app/ https://play.google.com/store/apps/
kls-martin-energy-devices/id1198171415?l=de&ls=1&mt=8 details?id=com.klsmartin.energydevices

KLS Martin SE & Co. KG


A company of the KLS Martin Group
KLS Martin Platz 1 · 78532 Tuttlingen · Germany
PO Box 60 · 78501 Tuttlingen · Germany
Tel. +49 7461 706-0 · Fax +49 7461 706-193
info@klsmartin.com · www.klsmartin.com

90-134-02-09 · Rev. 03 · 2023-11 · Printed in Germany · Copyright by KLS Martin SE & Co. KG · All rights reserved · Subject to technical changes

You might also like