Professional Documents
Culture Documents
Me MB 3
Me MB 3
www.klsmartin.com
ME MB 3 – The efficient
solution for the OR.
Innovation: cost-efficient and user-friendly
3
KLS Martin electrosurgical unit: ME MB 3
1 2 3 4 5
6 7 8 9 10
10 11 12 13 14
15 16 17 18 19
20 21 22 23 24
25 26 27 28 29
Power setting constantly under visual control Each time the unit is turned on, the KLS Martin
1 2 3 4 5 1 2 3 4 5
ME MB 3 performs a self-test. If an error or
6 7 8 9 10 6 7 8 9 10
High patient safety thanks to PCS NE monitoring malfunction is detected, no acknowledgement
10 11 12 13 14 10 11 12 13 14
(Patient Control System) signal is emitted and HF current output is auto-
1 2 3 4 5
15 16 17 18 19
In high-frequency surgery, the thermal effect matically blocked. This ensures that the KLS
15 16 17 18 19
6 7 8 9 10
must be strictly limited to the point 20
of application
21 22 23 24 Martin ME MB 3 can be used 20 only
21 under
22 perfect
23 24
10 11 12 13 14
of the active electrode. In other words,25 no26 heat
27 28 29
operating conditions. 25 26 27 28 29
15 16 17 18 19
must be allowed to develop underneath the
30 31 32 33 34 30 31 32 33 34
neutral electrode (NE). To ensure 20
this,
21
HF22
units
23 24
Monopolar handle connections
from KLS Martin are equipped with 25 NE
26 monitoring
27 28 29 In the “m” version, the KLS Martin ME MB 3
1 2 3 4 5
functions designed to keep the neutral electrode allows you to connect handles with a KLS Martin
30 31 32 33 34 6 7 8 9 10
under constant control, blocking monopolar HF plug or a US 3-pin plug. The “i” version, in turn,
10 11 12 13 14
energy output as soon as an NE problem occurs is designed for connection of monopolar handles
15 16 17 18 19
due to lack of skin contact. A split neutral elec- with Bovie plug or US 3-pin plug.
trode is required for this function. 20 21 22 23 24
The PCS system, in fact, continuously monitors you a wide selection of handles for various appli-
30 31 32 33 34
correct attachment of the NE to the patient’s cations. For details, please refer to our special
skin. If the NE detaches in any way, the user HF Accessories Catalog.
is immediately alerted – well before critical
situations could arise.
4
1 2 3 4 5
6 7 8 9 10
10 11 12 13 14 1 12 23 34 45 5 1 2 3 4 5
15 16 17 18 19 6 67 78 89 910 10 6 7 8 9 10
25 26 27 28 29
30 31 32 33 34
steadily increasing 25
power
26
output.
27 28
It is
29
this high ensures the best possible coagulation result.
30 31 32 33 34
“power reserve” that warrants the universal
30 31 32 33 34
applicability of the KLS Martin ME MB 3.
10 11 12 13 14
The double-pedal foot switch (for cutting/
15 16 17 18 19
coagulation) can be used for monopolar
as well as bipolar operation. 20 21 22 23 24
25 26 27 28 29
30 31 32 33 34
Bipolar coagulation with the foot switch Multifunctional connector
1 2
for bipolar
3 4
instruments
5
1 2 3 4 5
The power spectrum of the KLS Martin ME MB 3 This is a bipolar combination socket for active
6 7 8 9 10 6 7 8 9 10
is rounded off by the “Bipolar Coagulation” electrodes, allowing you to connect the small
10 11 12 13 14 10 11 12 13 14
option used in conjunction with the foot switch. coaxial plug (KLS Martin standard) or interna-
15 16 17 18 19 15 16 17 18 19
This reliable bipolar coagulation function from tional accessories from other manufacturers.
KLS Martin allows you to combine20
high-precision
21 22 23 24 20 21 22 23 24
30 31 32 33 34 30 31 32 33 34
5
KLS Martin electrosurgical unit: ME MB 3
m “m” version, ME MB 3
for KLS Martin accessories
i “i” version, ME MB 3
for international accessories
classic scalpel cut, thus providing the best basis ded for special applications, e.g. for endoscopic
15 16 17 18 19 15 16 17 18 19
for effective wound healing. papillotomy and endoscopic polypectomy.
20 21 22 23 24 20 21 22 23 24
25 26 27 28 29 25 26 27 28 29
30 31 32 33 34 30 31 32 33 34
15 16 17 18 19
20 21 22 23 24
25 26 27 28 29
30 31 32 33 34
Monopolar Cut 3 (Super Blend Cut)1 2 3 4 5 Power Peak – the power boost 1 2 1 3 21 4 32 5 4
coagulated during the cutting process, bleeding for use in urology/gynecology (cutting in liquid
20 21 22 23 24 20 2120 222120 232221 242
from dissected capillary vessels is stopped at environments*)
once and extended hemorrhages are25 prevented.
26 27 28 29 25 2625 272625 282726 292
* Power Peak just when activationis carried out per foot switch
6
1 2 1 3 2 4 3 5 4 5
1 2 1 3 2 1 4 3 2 51 4 3 2 5 4 3 51 4 2 5 3 4 5 6 7 6 8 7 9 8 10 9 10
6 7 6 8 7 6 9 8 7 106 9 8 7 10 9 8 106 9 7 10 8 9 10 10 11 10 12 11 13 12 14 13 14
10 11 10 12 11 10 13 12 11 14
10 13 12 11 14 13 12 14
10 13 11 14 12 13 14 15 16 15 17 16 18 17 19 18 19
15 16 15 17 16 15 18 17 16 19
15 18 17 16 19 18 17 19
15 18 16 19 17 18 19 20 21 20 22 21 23 22 24 23 24
20 21 20 22 21 20 23 22 21 24
20 23 22 21 24 23 22 24
20 23 21 24 22 23 24
25 26 25 27 26 28 27 29 28 29
25 26 25 27 26 25 28 27 26 29
25 28 27 26 29 28 27 29
25 28 26 29 27 28 29
30 31 30 32 31 33 32 34 33 34
30 31 30 32 31 30 33 32 31 34
30 33 32 31 34 33 32 34
30 33 31 34 32 33 34
1 2 3 4 5
in direct contact with the tissue). (fulguration). It is especially suited for hemostasis
15 16 17 18 19
10 11 12 13 14
during TUR procedures using small-surface
15 16 17 18 19 20 21 22 23 24
electrodes (e.g. loop electrodes).
20 21 22 23 24 25 26 27 28 29
25 26 27 28 29
30 31 32 33 34
30 31 32 33 34
1 2 3 4 5
30 31 32 - marLap
33 34 instruments
marCut®
nonStick flush
nonStick red
7
KLS Martin electrosurgical unit: ME MB 3
HF trolleys
8
HF trolley
9
Product range: Accessories for ME MB 3
smartPen
80-160-00-04 Standard Set A for ME MB 3, “m” version 80-140-00-04 Large Set of monopolar accessories for hand
(and other major HF units from KLS Martin) activation for ME MB 3, “m” version
80-701-35-04 1 Disposable electrode handles, SU = 25/pack 80-217-13-04 1 smartPen Electrode handle with two pushbuttons
80-344-09-04 1 Disposable DuoSafe neutral electrodes, for 4-mm electrodes, with KLS Martin plug
SU = 50/pack 80-342-07-04 1 Twin-Pad II neutral electrode with two contact
80-294-40-04 1 KLS Martin connection cable surfaces (split), contact surface 200 cm², without
for disposable neutral electrodes connection cable
80-505-00-04 1 Cleaning pad for electrodes, 80-373-00-04 1 Textile band with velcro strap, 100 cm,
sterile packed, SU = 100/pack washable at 60°C
80-811-30-04 1 Foot switch 80-416-00-01 1 Electrode container for 16 electrodes
80-505-00-04 1 Cleaning pad for electrodes,
sterile packed, SU = 100/pack
80-160-01-04 Standard Set B for ME MB 3, “i” version 80-510-06-04 1 Lancet electrode, straight, SU = 5/pack
80-221-02-04 1 Disposable electrode handles, SU = 10/pack 80-511-06-04 1 Lancet electrode, angled
80-344-09-04 1 Disposable DuoSafe neutral electrodes, 80-515-04-04 1 Knife electrode
SU = 50/pack 80-520-06-04 1 Needle electrode, SU = 5/pack
80-294-44-04 1 Valleylab connection cable 80-540-04-04 1 Wire loop electrode, Ø = 5 mm
for disposable neutral electrodes 80-542-06-04 1 Wire loop electrode, Ø = 10 mm
80-505-00-04 1 Cleaning pad for electrodes, 80-550-06-04 1 Ribbon loop electrode, Ø = 10 mm
sterile packed, SU = 100/pack 80-560-06-04 1 Ball electrode, Ø = 2 mm, SU = 5/pack
80-811-30-04 1 Foot switch 80-562-06-04 1 Ball electrode, Ø = 4 mm, SU = 5/pack
10
marCut®
Technical data
ME MB 3 nonStick red
nonStick flush
marLap
80-140-01-04 Large Set of monopolar accessories for foot 80-150-00-04 Set of bipolar accessories,
activation for ME MB 3, “m” version for ME MB 3, “m” version
80-220-02-04 1 smartPen electrode handle without pushbuttons 80-287-53-04 1 Connecting cable for bipolar forceps
for 4-mm electrodes, with KLS Martin plug 80-924-16-04 1 Bipolar forceps, straight, blunt, 16 cm/6 1⁄4"
80-342-07-04 1 Twin-Pad II neutral electrode with two contact 80-945-20-04 1 Bipolar forceps, bayonet-shaped, blunt, 20 cm/8"
surfaces (split), contact surface 200 cm², without 80-925-16-04 1 Bipolar forceps, angled, blunt, 16 cm/6 1⁄4"
connection cable 80-925-20-04 1 Bipolar forceps, angled, blunt, 20 cm/8"
80-373-00-04 1 Textile band with velcro strap, 100 cm, 80-924-20-04 1 Bipolar forceps, straight, blunt, 20 cm/8"
washable at 60°C
80-416-00-01 1 Electrode container for 16 electrodes
80-505-00-04 1 Cleaning pad for electrodes, 80-150-01-04 Set of bipolar accessories with nonStick red
sterile packed, SU = 100/pack forceps, for ME MB 3, “m” version
80-510-06-04 1 Lancet electrode, straight, SU = 5/pack 80-287-53-04 1 Connection cable for bipolar forceps
80-511-06-04 1 Lancet electrode, angled 80-986-17-04 1 Bipolar forceps, nonStick red,
80-515-04-04 1 Knife electrode straight, blunt, 16 cm/6 1⁄4"
80-520-06-04 1 Needle electrode, SU = 5/pack 80-992-20-04 1 Bipolar forceps, nonStick red,
80-540-04-04 1 Wire loop electrode, Ø = 5 mm bayonet-shaped, blunt, 20 cm/8"
80-542-06-04 1 Wire loop electrode, Ø = 10 mm 80-987-17-04 1 Bipolar forceps, nonStick red,
80-550-06-04 1 Ribbon loop electrode, Ø = 10 mm angled, blunt, 16 cm/6 1⁄4"
80-560-06-04 1 Ball electrode, Ø = 2 mm, SU = 5/pack 80-987-20-04 1 Bipolar forceps, nonStick red,
80-562-06-04 1 Ball electrode, Ø = 4 mm, SU = 5/pack angled, blunt, 20 cm/8"
80-830-00-04 1 Double-pedal foot switch, anti-explosive, 80-986-20-04 1 Bipolar forceps, nonStick red,
with connection cable of 5 m straight, blunt, 20 cm/8"
11
Product range: Accessories for ME MB 3
Ordering information
12
Technical data
ME MB 3 from KLS Martin
ME MB 3 technical data
Power requirements 220–240 V, 50–60 Hz
Power input without HF output: approx. 26 VA
at max. power output: approx. 800 VA
Leakage currents LF and HF in compliance with IEC 60601-1 and 2-2
Nominal frequency 450 kHz
Modulation frequency 30 kHz
HF output power:
Type of current Power Crest factor Voltage
Cut 1 (pure) max. 400 W at 300 Ω 1.6 at 300 Ω max. 1,500 Vp
Cut 2 (blend) max. 300 W at 300 Ω 1.9 at 300 Ω max. 2,000 Vp
Cut 3 (super blend) max. 200 W at 300 Ω 2.4 at 300 Ω max. 1,600 Vp
Forced Prep max. 120 W at 200 Ω 4.9 at 200 Ω max. 2,100 Vp
Endo Mode max. 100 W at 200 Ω 1.6 at 200 Ω max. 1,200 Vp
Contact coagulation max. 250 W at 200 Ω 3.4 at 200 Ω max. 2,100 Vp
Spray coagulation max. 120 W at 300 Ω 5.6 at 300 Ω max. 4,400 Vp
Bipolar coagulation max. 100 W at 100 Ω 2.1 at 100 Ω max. 350 Vp
Line fuses 220–240 V: T 4 A (slow-blow)
Sound level HF current activation: 40 - 65 dB (adjustable)
Alarm: 65 dB(A)
Weight 8.6 kg
Interference suppression Limits in conformity with EN 55011
Interference immunity in conformity with IEC 801
Dimensions Width: 405 mm; height: 135 mm; depth: 380 mm
13
Service: information materials and catalogs
marVac®
maXium® smart Vac
4 Effective
4 Ergonomic
4 Safe
marVac®/maxium® smartVac –
the innovative system for efficient removal of surgical plume
14
Should you have any queries …
… we’ll be glad to be at your service!
15
KLS Martin Group
KLS Martin Australia Pty Ltd. KLS Martin do Brasil Ltda. KLS Martin Medical (Shanghai) KLS Martin India Pvt Ltd.
Sydney · Australia São Paulo · Brazil International Trading Co., Ltd Chennai · India
Tel. +61 2 9439 5316 Tel. +55 11 3554 2299 Shanghai · China Tel. +91 44 66 442 300
australia@klsmartin.com brazil@klsmartin.com Tel. +86 21 5820 6251 india@klsmartin.com
info@klsmartin.com
KLS Martin Italia S.r.l. KLS Martin Japan K.K. KLS Martin SE Asia Sdn. Bhd. KLS Martin de México, S.A. de C.V.
Milan · Italy Tokyo · Japan Penang · Malaysia Mexico City · Mexico
Tel. +39 039 605 67 31 Tel. +81 3 3814 1431 Tel. +604 261 7060 Tel. +52 55 7572 0944
info@klsmartin.com info@klsmartin.com malaysia@klsmartin.com mexico@klsmartin.com
KLS Martin Nederland B.V. KLS Martin SE & Co. KG KLS Martin Taiwan Ltd. KLS Martin SE & Co. KG
Huizen · Netherlands Moscow · Russia Taipei · Taiwan Dubai · United Arab Emirates
Tel. +31 35 523 45 38 Tel. +7 499 792 76 19 Tel. +886 2 2325 3169 Tel. +971 4 454 16 55
infonl@klsmartin.com russia@klsmartin.com taiwan@klsmartin.com middleeast@klsmartin.com
KLS Martin UK Ltd. KLS Martin LP KLS Martin SE Asia Sdn. Bhd.
Reading · United Kingdom Jacksonville · Florida, USA Hanoi · Vietnam
Tel. +44 118 467 1500 Tel. +1 904 641 77 46 Tel. +49 7461 706-0
info.uk@klsmartin.com usa@klsmartin.com info@klsmartin.com
https://itunes.apple.com/de/app/ https://play.google.com/store/apps/
kls-martin-energy-devices/id1198171415?l=de&ls=1&mt=8 details?id=com.klsmartin.energydevices
90-134-02-09 · Rev. 03 · 2023-11 · Printed in Germany · Copyright by KLS Martin SE & Co. KG · All rights reserved · Subject to technical changes