Download as pdf or txt
Download as pdf or txt
You are on page 1of 100

Fans and blowers

for solid fuel heating systems

Product Catalog 2022-06


The perfect combination of

size, performance and efficiency

Environmentally friendly, cost effective and constantly renewable – Particularly efficient with EC and condensing technology
heating with biomass offers many advantages compared to burning
fossil fuels. However, wood pellet and wood chip heating systems In solid-fuel heating systems, a distinction is made between traditio-
have very special requirements: the air flow required for different nal conventional heating and modern condensing technology. Whe-
functions must be provided economically in each operating state and reas with conventional heating most of the waste heat can get into
regardless of the heating power. There is also limited space in stoves. the open air via the chimney, condensing technology makes as much
The fans required for this must be robust and compact. use of this energy as possible. Heat from the water vapor produced
when the wood pellets or wood chips burn is recovered and fed back
ebm-papst offers the right fans to overcome these challenges. The into the heating system. This increases the efficiency and reduces
fans for the combustion air supply, exhaust gas removal and distribu- the heating costs.
tion of hot air in the installation area are tailored to different power
classes and equipped with fan impellers optimized for biomass appli- ebm-papst offers a wide range of AC and EC fans for traditional con-
cations. Due to their compact design, they are robust, durable and ventional heating. In modern condensing technology, using more
require hardly any space. This facilitates having the optimum size, efficient EC fans is particularly worthwhile, as they can be optimally
performance and cost-effectiveness in any application. adapted to the relevant operating point using their variable speed.

2
Fans and blowers for solid fuel heating systems

Contents

Page Page

Information 4 About ebm-papst 4

Information
Was engineering a better life für uns bedeutet.

Induced draft fan 6 About induced draft fan 8

Induced draft fan


Induced draft fan AC 10
Induced draft fan EC 32

Convection heat 50 About convection heat 52

Convection heat
Convection heat centrifugal fans 54
Convection heat tangential fans 68

Combustion air blower 76 About combustion air blower 78

Combustion air blower


Combustion air blower AC 80

Additional information 84 Scroll dimensions 86

Additional information
Additional shaft seal 88
Electrical connections 89
Technical parameters & scope 94

Contacts 98 Contacts worldwide 98


Contacts

Fans and blowers for solid fuel heating systems · Edition 2022-06 3
What Engineering
a better life
means to us.

4
Who we are. What drives us.
With over 20,000 different products, ebm-papst offers the right But our consistent pursuit of efficiency and progress has even deeper
solution for just about any challenge. As the logical next stage roots. After all, there is something that excites us even more than our
in the development of our highly-efficient GreenTech EC tech- market position. It is the deep awareness that, with our solutions, like
nology, we believe that industrial digitization offers the greatest the VSW0210, we are making the lives of many people around the
future prospects for our customers. With GreenIntelligence, globe more pleasant, safer and thus better. Therefore, the central
we already represent intelligently interconnected complete driving force in all our thoughts and actions is Engineering a better
solutions that are unrivaled worldwide. life. It is the reason why it is worthwhile for us to get up every day
and do our best.
Because we are always committed to making each of our inno-
vative hardware and software solutions more powerful, com- More about this under ebmpapst.com/betterlife
pact, efficient and sustainable than its predecessor, we have
evolved over the years into the global technology leader for
ventilation and drive technology.

What you get out of it.

1. Technological edge.
With our EC technology and GreenIntelligence,
we combine the highest energy efficiency with
4. The ebm-papst spirit of invention.
Over 800 engineers and technicians will develop a solution
that precisely fits your needs.
the advantages of IoT and digital networking.

2. Our sustainable approach.


We take our responsibility seriously
5. Personal proximity to you.
Thanks to numerous sales locations worldwide.

6.
with energy-saving products, environ­- Our standard of quality.
mentallyfriendly processes and Our quality management is uncompromising, at every
through social engagement. step and in every process.

3. System expertise.
As experts in advanced motor technology,
electronics and aerodynamics, we provide perfect
system solutions from a single source.

Fans and blowers for solid fuel heating systems · Edition 2022-06 5
Fans and blowers for solid fuel heating systems

Induced draft fan

6
Induced draft fan

Product overview
Dimensions in mm Heat output range Type Part number Page

AC:

Ø 140 4 – 12kW VSW0140X2MCS R2E140CD76** 10


Ø 150 5 – 18kW VSW0150X2MCS R2E150AO91** 12
Ø 150 5 – 18kW VSW0150X2MCS R2E150AN91** 12
Ø 150 5 – 18kW VPW0150X2MCS G2E150DO91** 14
Ø 150 5 – 18kW VPW0150X2MCS G2E150DN91** 14
Ø 150 5 – 20kW VSW0150X2MES R2E150AP82** 16
Ø 150 5 – 20kW VSW0150X2MES R2E150AK82** 16

Induced draft fan


Ø 150/160 10 – 35kW VSW0160X2MGS R2E160BG34** 18
Ø 150/160 10 – 35kW VSC0150X2NGS R2E150AL06** 18
Ø 152 5 – 15kW VBS0152XQFFS 55462.09170 20
Ø 152 5 – 15kW VCS0152XQFFS 55462.50050 22
Ø 180 24 – 35kW VSW0180X2MES R2E180CV82** 24
Ø 180 24 – 35kW VSW0180X2MES R2E180CG82** 24
Ø 180 24 – 35kW VPW0180X2MES G2E180CV82** 26
Ø 180 24 – 35kW VPW0180X2MES G2E180GV82** 26
Ø 210 35 – 55kW VSW0210X2MGS R2E210AA34** 28
Ø 210 35 – 55kW VSW0210X2MGS R2E210AB34** 28
Ø 250 55 – 80kW VSW0250X2NKS R2E250BE0310 30

EC:

Ø 140 10 – 24kW VSW0140XSLBS R3G140AG03** 32


Ø 150 10 – 24kW VSW0150XSLBS R3G150AA03** 34
Ø 150 10 – 24kW VSW0150XSLCS R3G150AC01** 34
Ø 150 10 – 24kW VSW0150XULCS R1G150AA63** 36
Ø 150 10 – 24kW VPW0150XSLBS G3G150DA03** 38
Ø 160 10 – 24kW VSW0160XSLCS R3G160AE01** 40
Ø 180 25 – 50kW VSW0180XSLCS R3G180AH01** 42
Ø 180 25 – 50kW VSW0180XSLES R3G180AJ11** 42
Ø 180 25 – 50kW VPW0180XSLES G3G180FJ11** 44
Ø 180 25 – 50kW VPW0180XSLES G3G180GJ11** 44
Ø 210 50 – 150kW VSW0210XSNEZ R3G210AE5310 46
Ø 250 100 – 250kW VSC0250XSPGZ R3G250BE04H1 48

The induced draft blowers from ebm-papst are used,


for example, in biomass boilers and pellet stoves.

Fans and blowers for solid fuel heating systems · Edition 2022-06 7
Fans for solid fuel heating systems

Induced draft fan

Suction power can be optimally adapted

Induced draft fans are used in biomass stoves ebm-papst offers induced draft fans with and without fan housing, with various bla-
in living rooms and biomass heating systems in des and, depending on the air flow requirement, in different fan impeller diameters.
cellars. There, they extract the hot exhaust ga- They are also available in versions with AC and EC motors. The fan impellers are cur-
ses that form when wood pellets, wood chips ved backwards. In the EC version, the induced draft fans are particularly economical
Induced draft fan

or firewood are burned and send them to the thanks to a highly efficient motor and thanks to their controllability. By adjusting the
chimney. They have to withstand high tem- speed, the suction power can always be optimally adjusted to the relevant heat load.
peratures. For this reason, the motor for the- At partial load, this also reduces the fan's power requirement at the same time.
se blowers is located outside the fan housing.
Condensing units have an additional advanta- For special application conditions, the fans can also be equipped with a special shaft
ge here: as their exhaust gas temperatures are seal that is specifically adapted to the flow medium. Further information can be
much lower, they are much more efficient. found on page 88.

Comparison characteristic curves AC EC DC


in wg

in wg
Pa

Pa

A 2
1600
D
6

300 H
B 2
B 2
5

1200
1

A
F
4

200
G
A 800
A 1
D B 1
3

K
B 1 C I
C F E 2
2

100
400 H
E G 1

G 2 J 1
1

J 2
E 1

0 100 cfm 0 100 200 300 400 500 600 cfm


P fs

P fs

qv 50 100 150 200 250 m³/h qv 200 400 600 800 1000 m³/h

8 Fans and blowers for solid fuel heating systems · Edition 2022-06
Induced draft fan heat output range

Overview

4 – 12kW A R2E140CD76**

5 – 15kW B VBS0152XQFFS

5 – 15kW C VCS0152XQFFS

5 – 18kW D R2E150AO91** / R2E150AN91**

Induced draft fan


5 – 18kW E G2E150DO91** / G2E150DN91**

5 – 20kW F R2E150AP82** / R2E150AK82**

10 – 24kW A R3G140AG03**

10 – 24kW B R3G150AA03** / R3G150AC01**

10 – 24kW A R1G150AA63**

10 – 24kW C G3G150DA03**

10 – 24kW D R3G160AE01**

10 – 35kW G R2E160BG34** / R2E150AL06**

24 – 35kW H R2E180CV82** / R2E180CG82**

24 – 35kW I G2E180CV82** / G2E180GV82**

25 – 50kW E R3G180AH01** / R3G180AJ11**

25 – 50kW F G3G180FJ11** / G3G180GJ11**

35 – 55kW J R2E210AA34** / R2E210AB34**

R3G210AE5310 G 50 – ... ... 150kW

R2E250BE0310 K 55 – ... 80kW

R3G250BE04H1 H 100 – ... 250kW

0 10 20 30 40 50 ... 80 ... 150 ... 250

Fans and blowers for solid fuel heating systems · Edition 2022-06 9
AC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 140

Heat output range1


■ 4 – 12kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44,
Induced draft fan

depending on installation and position


■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none
page 93 Electrical connections A1), D) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
Pa

in H2O

(test circuit, illustration 4)


■ Standard:
Speed monitoring via Hall IC
A
■ Cable exit: variable
■ Protection class: I (if customer has provided
4
connection for protective earth)
Standards and approvals
■ Standards: EN 60335-1, CE
3 ■ Approvals:
UL, CSA, CCC, EAC are applied for
Optional
■ Also possible without protection hood
■ Additional shaft seal see page 88

cfm
pfs

qV m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

10 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E140CD76**

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB °C kg
Type Part number Fan type

Cable
R2E140CD7601 design ❶ 215 2650 28 0.14
❷ 215 2635 28 0.14
VSW0140X2MCS M2E 068-BF A ❸ 215 2660 28 0.13
0.68/400 -25...+60 1.6

R2E140CD7605 Plug ❹ 215 2695 26 0.12


design

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

87 53.5±1.5 76 25°
42
4x9

Ø165.3
Ø140
Ø116

4xØ4.5
450±20

Ø1
58

123456 Wieland
Wieland 93.031.3253.0
93.032.3353.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 11
AC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 150

Heat output range1


■ 5 – 18kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44,
Induced draft fan

depending on installation and position


■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none
page 93 Electrical connections A1), D) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
Pa

in H2O

(test circuit, illustration 4)


200 ■ Standard:
Speed monitoring via Hall IC
A
180 ■ Cable exit: variable
0,7

■ Protection class: I (if customer has provided


connection for protective earth)
160 4
Standards and approvals
0,6

140 ■ Standards: EN 60335-1, CE


■ Approvals:
0,5

120 UL, CSA, CCC, EAC are applied for


Optional
100
0,4

3
■ Additional shaft seal see page 88

80
0,3

60
0,2

40
0,1

20

0 20 40 60 80 100 120 cfm


pfs

qV 40 80 120 160 200 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

12 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E150AO91** / R2E150AN91**

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB °C kg
Type Part number Fan type

Cable
R2E150AO9101 design
VSW0150X2MCS ❶ 200 2400 32 0.15
❷ 200 2410 31 0.14
R2E150AO9105 Plug M2E 068-BF A ❸ 200 2435 31 0.14
1.0/400 -25...+55 1.7
design
❹ 200 2485 30 0.13
without
VSW0150X2MCS R2E150AN9101 motor pro-
tection hood

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

87 31.5±1.5 76 25° Connection


20 No. Function Color
1 L blue
2 PE green/yellow
4x9

3 N black

4 GND black
Ø165.3
Ø152
Ø116

5 OUT white
6 VCC red

4xØ4.5
450±20

Ø1
58

80±1 31,5±1,5 76 25˚


63 20
2
0,

4x9
15
Ø


Ø165,3
Ø152

4xØ4,5
450±20

1 2 3456 Wieland
Wieland 93.031.3253.0
93.032.3353.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 13
AC centrifugal blowers (exhaust air)
for solid fuel heating systems, single inlet, Ø 150

Heat output range1


■ 5 – 18kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
■ Housing: Hot-dip aluminised sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
Induced draft fan

■ Type of protection: IP 44
■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none, open rotor
page 93 Electrical connections A1), D)
■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
in H2O
Pa

280 (test circuit, illustration 4)


■ Standard:
Speed monitoring via Hall IC
1,0

■ Protection class: I
240
A Standards and approvals
■ Standards: EN 60335-1, CE;
200 UKCA on request
0,8

4
■ Approvals:
UL, CSA, CCC, EAC are applied for
160 Optional
0,6

3 ■ Additional shaft seal see page 88

120
0,4

80
2
0,2

40

1
0 10 20 30 40 50 60 70 80 cfm
pfs

qV 20 40 60 80 100 120 140 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and 1Heat output range
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

14 Fans and blowers for solid fuel heating systems · Edition 2022-06
G2E150DO91** / G2E150DN91**

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB °C kg
Type Part number Fan type

Cable
G2E150DO9101 -25...+50 2.3
design

VPW0150X2MCS
❶ 145 2480 30 0.14
Plug ❷ 145 2505 30 0.13
G2E150DO9105 design
M2E 068-BF A ❸ 145 2560 29 0.13
1.0/400 -25...+50 2.3
❹ 145 2620 28 0.12

Cable design
VPW0150X2MCS G2E150DN9101 without pro- -25...+70 2.3
tection hood

Induced draft fan


Subject to changes.

Technical drawing Dimensions in mm

137
149 8.6 Ø80 P X Y Connection
P9 P11
32 1 -24.7 -100.6
P10 P12 No. Function Color
2 -20.8 -87.1 1 L blue
3 -34.3 -97.8 2 PE green/yellow
118.2

4 -30.4 -84.4 3 N black


5 -49.0 97.3 4 GND black
62

6 -41.6 85.4 5 OUT white


Ø116

P2 7 -57.5 92.0 6 VCC red


P1
P6 8 -50.1 80.1
P3 P5
87

P4 9 120.3 49.4
P7
10 108.5 41.9
P8
450±20

52
11 114.9 57.8
85±10

12 103.1 50.3
6

85 94.2

137
149 8.6 Ø80
P9 P11 132
32 P10 P12
118.2
62

Ø116

Ø92

P2
P1
P6
P3 P5
90.4

1 P4
2 P7
3 P8
4
5
6 52
85 94.2

Fans and blowers for solid fuel heating systems · Edition 2022-06 15
AC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 150

Heat output range1


■ 5 – 20kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44,
Induced draft fan

depending on installation and position


■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none
page 93 Electrical connections A1), D) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
Pa

in H2O

(test circuit, illustration 4)


220
A ■ Standard:
Speed monitoring via Hall IC
200 ■ Cable exit: variable
0,8

■ Protection class: I (if customer has provided


180 4 connection for protective earth)
Standards and approvals
160
■ Standards: EN 60335-1, CE
0,6

140 ■ Approvals:
UL, CSA, CCC, EAC are applied for
120 3
Optional
■ Additional shaft seal see page 88
100
0,4

80

60
0,2

40

20

0 20 40 60 80 100 120 cfm


pfs

qV 40 80 120 160 200 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

16 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E150AP82** / R2E150AK82**

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB °C kg
Type Part number Fan type

Cable
R2E150AP8201 -25...+60 1.8
design
VSW0150X2MES ❶ 220 2750 44 0.27
❷ 220 2760 44 0.27
R2E150AP8205 Plug M2E 068-CF A ❸ 220 2770 43 0.26
1.0/400
-25...+60 1.8
design
❹ 220 2795 41 0.26
without
VSW0150X2MES R2E150AK8201 motor pro- -25...+70 2.0
tection hood

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

108 53.5±1.5 76 25° Connection


42 No. Function Color
1 L blue
2 PE green/yellow
4x9

3 N black

4 GND black
Ø165.3
Ø148
Ø119

5 OUT white
6 VCC red

4xØ4.5
450±20

Ø1
58

90±1 53,5±1,5 76 25˚


73 42
2
0,

4x9
15
Ø


Ø165,3
Ø148

4xØ4,5
450±20

1 2 3456 Wieland
Wieland 93.031.3253.0
93.032.3353.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 17
AC centrifugal fans (exhaust air)
for solid fuel heating systems, special designs, Ø 150/160

Heat output range1


■ 10 – 35kW
Material/surface
■ Impeller: Sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44
Induced draft fan

■ Insulation class: "F"


■ Mounting position: any
■ Condensate discharges: none
from page 86 Scroll dimensions ■ Mode of operation:
page 93 Electrical connections A1), D) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
(test circuit, illustration 4)
Pa

in H2O

■ Standard:
A
Speed monitoring via Hall IC
■ Cable exit: variable
B
■ Protection class: I
Standards and approvals
■ Standards: EN 60335-1, CE
■ Approvals:
UL, CSA, CCC, EAC are applied for
Optional
■ Additional shaft seal see page 88

cfm
pfs

qV m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

18 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E160BG34** / R2E150AL06**

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB db(A) °C kg
Type Part number Fan type
without
R2E160BG3401 motor pro-
tection hood
❶ 285 2780 57 0.26
VSW0160X2MGS M2E 068-DF A ❷ 285 2830 48 0.22
1.5/400 64 -25...+90 3.8
with
R2E160BG3405 motor pro-
tection hood

without
R2E150AL0601 motor pro-
tection hood
❶ 460 2785 78 0.35
VSC0150X2NGS M2E 074-DF B ❷ 460 2840 65 0.30
3.0/400 67 -25...+85 4.0
with
R2E150AL0605 motor pro-
tection hood

Induced draft fan


Subject to changes.

Technical drawing Dimensions in mm

e ±1 a ±1.5 Ø210 Dimensions


f b Ø190±0.2 VSW0160X2MGS VSC0150X2NGS
R2E160BG34** R2E150AL06**
a 50 84
b 40 74
d 160 150
e 103 135
f 83 110
Ød

g 132 144
h 109 146
450+ 20

4xØ9

h ±1
Øg

Fans and blowers for solid fuel heating systems · Edition 2022-06 19
AC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 152

Heat output range1


■ 5 – 15kW
Material/surface
■ Impeller: corrosion resistant stainless steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 00
Induced draft fan

■ Insulation class: "H"


■ Mounting position: Shaft position horizontal
■ Mode of operation:
from page 86 Scroll dimensions Continuous operation (S1)
page 93 Electrical connections B) ■ Bearings: Sleeve bearings / ball bearings
More at www.ebmpapst.com ■ Electrical Connection: via flat pin
■ Protection class: I
Standards and approvals
■ Standards: EN 60335-1;
Confirmation UKCA possible
Pa

in H2O

■ Approvals: VDE-compliant design,


optionally UL-compliant design possible
Optional
■ Hall IC-Connection
■ Motor protection hood
B
■ Additional shaft seal (see page 88)

cfm
pfs

qV m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

20 Fans and blowers for solid fuel heating systems · Edition 2022-06
VBS0152XQFFS

Perm. ambient temperature


Characteristic Curve

Speed free air flow

Max. current draw


Max. input power
Air flow

Weight
Nominal voltage 230VAC, 50Hz m3/h rpm W A °C kg
Type Part number

A 235 2575 49 0.4 0...+60 1.0


VBS0152XQFFS 55462.09170
B 150 2600 49 0.4 0...+60 1.0

Subject to changes. A measured without ebm-papst scroll housing. B measured with ebm-papst scroll housing.

Induced draft fan


Technical drawing Dimensions in mm

31.5±1.5
45°
20 45°

30.3±0.4
Ø152+1

Ø4.5
max. 81 Ø158±0.2
Ø165,3±0.5

Fans and blowers for solid fuel heating systems · Edition 2022-06 21
AC centrifugal blowers (exhaust air)
for solid fuel heating systems, single inlet, Ø 152

Heat output range1


■ 5 – 15kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
■ Housing: Hot-dip aluminised sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
Induced draft fan

■ Type of protection: IP 00
■ Insulation class: "H"
■ Mounting position:
from page 86 Scroll dimensions any, except motor overhead
page 93 Electrical connections B) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Ball bearings / sleeve bearings
■ Max. exhaust gas temperature 250°C
■ Motor protection: TOP wired internally
■ Standard:
Speed monitoring via Hall IC
in H2O
Pa

■ Protection class: I
280
Standards and approvals
■ Standards: EN 60335-1, CE;
1,0

240 Confirmation UKCA possible


A
■ Approvals: EAC is applied for;
CCC, UL, CSA on request
4
200 Optional
0,8

■ Additional shaft seal (see page 88)

160
0,6

120
0,4

80
2
0,2

40

1
0 10 20 30 40 50 60 70 80 cfm
pfs

qV 20 40 60 80 100 120 140 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and 1Heat output range
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

22 Fans and blowers for solid fuel heating systems · Edition 2022-06
VCS0152XQFFS

Perm. ambient temperature


Characteristic Curve

Speed free air flow

Max. current draw


Max. input power
Operating point

Air flow

Weight
Nominal voltage 230VAC, 50Hz m3/h rpm W A °C kg
Type Part number

❶ 160 2600 43 0.38


❷ 127 2630 43 0.37
VCS0152XQFFS 55462.50050 A ❸ 93 2660 42 0.37
0...+60 2.3
❹ 54 2700 39 0.35

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

Connection suitable for


Molex Mini Spax
View Z socket housing series 5102
sensor 22-01-1034
2-pole Socket series 5103
B-B 1 08-70-0056...59
90°B-B 1 = V cc = 4.5...24V
2

90° 2 2 = V out
2

Ø4.5 3 3 = Ground
Ø3.2
149 Ø4.5 max.142.5
Ø3.2 °
136.7±2 32.5
149 max.142.5 x) 2.5°
9 41 20° 49 ( 3 3
136.7±2 10 )
9 41 20° 0.5+1
49
47±0.3(3x
10
0.5+1 47±0.3

106°
Ø80 ±0.4

B B Z
4
116±0.3

Ø9

106° 114
Ø80 ±0.4

B B Z Ø
°

4
116±0.3
122

Ø9

14
62

(214)

Ø1
°
122
62

(214)

51±0.3

22 ±0.3
51±0.3

22 ±0.3

52.9±1.5 82 ±0.3 91±0.3

(253.5) Flat connector suitable for 52.9±1.5 82 ±0.3 91±0.3


plug-in sleeve 6.3 x ... DIN 46247

(253.5)

Fans and blowers for solid fuel heating systems · Edition 2022-06 23
AC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 180

Heat output range1


■ 24 – 35kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44,
Induced draft fan

depending on installation and position


■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none
page 93 Electrical connections A1), D) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
Pa

in H2O

(test circuit, illustration 4)


■ Standard:
320 Speed monitoring via Hall IC
A
■ Cable exit: variable
1,2

280 ■ Protection class: I


4 Standards and approvals
1,0

240 ■ Standards: EN 60335-1, CE


■ Approvals:
UL, CSA, CCC, EAC are applied for
200
0,8

Optional
3
■ Additional shaft seal see page 88
160
0,6

100

120
2
0,4

80
0,2

40

1
0 20 40 60 80 100 120 140 160 180 200 220 240 cfm
pfs

qV 50 100 150 200 250 300 350 400 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

24 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E180CV82** / R2E180CG82**

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB °C kg
Type Part number Fan type

Cable
R2E180CV8201 -25...+45 1.7
design
VSW0180X2MES ❶ 420 2500 75 0.34
❷ 420 2490 74 0.33
R2E180CV8205 Plug M2E 068-CF A ❸ 420 2520 72 0.32
2.0/400
-25...+45 1.7
design
❹ 420 2585 67 0.30
without
VSW0180X2MES R2E180CG8201 motor pro- -25...+60 2.3
tection hood

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

Connection
108 54.5±1.5
47. No. Function Color
45 5
Ø1 1 L blue
98
2 PE green/yellow
3 N black
4 GND black
5 OUT white
Ø180

4x90°
Ø210
Ø119

6 VCC red
450±20

4xØ4.5
90±1 54,5±1,5 Ø210
73 45 Ø198±0,2
Ø180
450±20

4xØ4,5
Wieland 1 2 3 4 5 6 Wieland
93.032.3353.0 93.031.3253.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 25
AC centrifugal blowers (exhaust air)
for solid fuel heating systems, single inlet, Ø 180

Heat output range1


■ 24 – 35kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
■ Housing: Hot-dip aluminised sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
Induced draft fan

■ Type of protection: IP 44
■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none, open rotor
page 93 Electrical connections A1), D)
■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
in H2O
Pa

(test circuit, illustration 4)


500 ■ Standard:
2,0

Speed monitoring via Hall IC


A ■ Protection class: I
Standards and approvals
400 4
1,6

■ Standards: EN 60335-1, CE;


UKCA on request
■ Approvals:
UL, CSA, CCC, EAC are applied for
300
1,2

3
Optional
■ Additional shaft seal see page 88

200
0,8

100
0,4

1
0 20 40 60 80 100 120 140 160 180 cfm
pfs

qV 50 100 150 200 250 300 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and 1Heat output range
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

26 Fans and blowers for solid fuel heating systems · Edition 2022-06
G2E180CV82** / G2E180GV82**

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB db(A) °C kg
Type Part number Fan type

Cable
G2E180CV8201 design*

VPW0180X2MES

Plug
G2E180CV8205 design
❶ 340 2600 65 0.30 73
❷ 340 2645 60 0.26 70
M2E 068-CF A ❸ 340 2700 55 0.24
1.0/400
64
-25...+60 3.0
❹ 340 2765 48 0.21 62
Cable
G2E180GV8201 design*

VPW0180X2MES

Induced draft fan


Plug
G2E180GV8205 design

Subject to changes. * Cable design also possible without protection hood

Technical drawing Dimensions in mm

174
Ø100 Connection
a 17 17
50 P9 P11 No. Function Color
P12
P10 1 L blue
A
2 PE green/yellow
3 N black
134.5

4 GND black
P6
5 OUT white
74.5

P5
6 VCC red
Ø119

P7
P8

P2 Detail A P X Y
105

P1
G2E180GV82** 1 -84.9 -88.4
450±20

P3
85±10

2 -75 -78.5
6

P4
101 115.3 66 3 -92 -81.3
4 -82 -71.4
5 16.5 134
174 6 16.5 120
Ø100 7 6.5 134
a 17 17
50 P9 P11 8 6.5 120
P10 P12 9 153 -5
A
10 139 -5
11 153 5
134.5

12 139 5
P6
74.5

P5
Ø119

Dimensions
P7
P8 VPW0180X2MES VPW0180X2MES
G2E180CV82** G2E180GV82**
105

1 P2
2
3
P1 a 186 223
4 P3
5
6 P4 101 115.3 66

Fans and blowers for solid fuel heating systems · Edition 2022-06 27
AC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 210

Heat output range1


■ 35 – 55kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44
Induced draft fan

■ Insulation class: "F"


■ Mounting position: any
■ Condensate discharges: none
from page 86 Scroll dimensions ■ Mode of operation:
page 93 Electrical connections A1), D) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
(test circuit, illustration 4)
Pa

in H2O

480 ■ Standard:
Speed monitoring via Hall IC
1,8

440 ■ Cable exit: variable


■ Protection class: I
400
1,6

B Standards and approvals


A
360 ■ Standards: EN 60335-1, CE
1,4

4 4
■ Approvals:
320 UL, CSA, CCC, EAC are applied for
1,2

280 Optional
■ Additional shaft seal see page 88
1,0

240 3 3

100
200
0,8

160
0,6

120 2 2
0,4

80
0,2

40

1 1
0 50 100 150 200 250 300 cfm
pfs

qV 100 200 300 400 500 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

28 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E210AA34** / R2E210AB34**

Perm. ambient temperature 1)


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB °C kg
Type Part number Fan type
without
R2E210AA3401 motor pro- ❶ 520 2500 110 0.49
tection hood
❷ 520 2495 109 0.48
VSW0210X2MGS A ❸ 520 2550 102 0.44
2.0/450 -25...+90 2.9
with
R2E210AA3405 motor pro- ❹ 520 2660 87 0.38
tection hood
M2E 068-DF
without
R2E210AB3401 motor pro- ❶ 600 2400 125 0.56
tection hood
❷ 600 2420 125 0.54
VSW0210X2MGS B ❸ 600 2455 122 0.53
2.5/400 -25...+70 3.1
with
R2E210AB3405 motor pro- ❹ 600 2545 111 0.48
tection hood

Induced draft fan


Subject to changes. 1) measured with motor protection hood: A = -25..+70°C B = -25..+45°C

Technical drawing Dimensions in mm

100 ±1 a ±1.5 Ø240 Dimensions


83 b Ø228±0.2 VSW0210X2MGS VSW0210X2MGS
R2E210AA34** R2E210AB34**
a 39,5 54,5
b 30 45
Ø210
450± 20

4xØ4.5

105 ±1
Ø132 ± 1

Fans and blowers for solid fuel heating systems · Edition 2022-06 29
AC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 250

Heat output range1


■ 55 – 80kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44,
Induced draft fan

depending on installation and position


■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none
page 93 Electrical connections A1), D) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
Pa

in H2O

(test circuit, illustration 4)


■ Standard:
Speed monitoring via Hall IC
600
2,4

4
■ Cable exit: variable
■ Protection class: I (if customer has provided
A connection for protective earth)
500
2,0

Standards and approvals


■ Standards: EN 60335-1, CE
■ Approvals:
400
1,6

3
UL, CSA, CCC, EAC are applied for
Optional
300 ■ Additional shaft seal see page 88
1,2

200
0,8

100
0,4

0 100 200 300 400 500 600 cfm


pfs

qV 200 400 600 800 1000 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

30 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E250BE0310

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB °C kg
Type Part number Fan type

❶ 1010 2500 260 1.15


with ❷ 1010 2540 258 1.13
VSW0250X2NKS R2E250BE0310 motor pro- M2E 074-EI A ❸ 1010 2590 243 1.06
7.0/400 -25...+50 8.1
tection hood
❹ 1010 2700 204 0.89

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

158 65.6
55.5 Ø290
4
6x6
Ø6 (4x) 0°
1 2 3 4 5 6

Connection
No. Function Color
1 Hall-IC black
2 Hall-IC white
3 Hall-IC red
Ø250
146

4 black + Capacitor
5 – green/yellow
6 – blue
75
Ø2

Fans and blowers for solid fuel heating systems · Edition 2022-06 31
EC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 140

Heat output range1


■ 10 – 24kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 54
Induced draft fan

■ Insulation class: "B"


■ Mounting position: any
■ Condensate discharges: none, open rotor
from page 86 Scroll dimensions ■ Mode of operation:
page 91, 93 Electrical connections H4), C) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Technical features:
See electrical connections p. 91 and 93
■ EMC:
in H2O
Pa

Interference emission acc. EN 61000-6-3


Interference immunity acc. EN 61000-6-2
A Harmonics acc. EN 61000-3-2/3
200 ■ Touch current: < 3,5mA acc. IEC 60990
0,8

(Test circuit, illustration 4)


4 ■ Cable exit: variable
■ Protection class: I (if customer has provided
160 connection for protective earth)
0,6

Standards and approvals


3
■ Standards: EN 60335-1, CE
■ Approvals:
120
VDE, UL, CSA, CCC, EAC are applied for
Optional
0,4

■ Additional shaft seal see page 88


80
2
0,2

40

1
0 20 40 60 80 100 120 cfm
pfs

qV 40 80 120 160 200 m 3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

32 Fans and blowers for solid fuel heating systems · Edition 2022-06
R3G140AG03**

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 1~200-240, 50/60Hz m3/h rpm W A db(A) °C kg
Type Part number Fan type

Cable
R3G140AG0301 design ❶ 220 2650 18 0.15
❷ 220 2635 18 0.15
VSW0140XSLBS M3G 055-AI A ❸ 220 2660 18 0.14
65 -25...+60 1.3

R3G140AG0305 Plug ❹ 220 2690 16 0.13


design

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

87 53.5±1.5 76 25° Connection


42 No. Function Color
1 N blue
2 PE green/yellow
3 L black
4x90

4 0-10V/PWM yellow
°

5 GND blue
Ø165.3
Ø116

Ø140

6 Tacho white

4xØ4.5
450±20

Ø1
58

12 3 4 5 6 Wieland
Wieland 93.031.3253.0
93.032.3353.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 33
EC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 150

Heat output range1


■ 10 – 24kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 54
Induced draft fan

■ Insulation class: "B"


■ Mounting position: any
■ Condensate discharges: none, open rotor
from page 86 Scroll dimensions ■ Mode of operation:
page 91, 93 Electrical connections H4), C) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Technical features:
See electrical connections p. 91 and 93
■ EMC:
Pa

in H2O

Interference emission acc. EN 61000-6-3


280 Interference immunity acc. EN 61000-6-2
Harmonics acc. EN 61000-3-2/3
■ Touch current: < 3,5mA acc. IEC 60990
1,0

240 B (Test circuit, illustration 4)


■ Cable exit: variable
■ Protection class: I (if customer has provided
200 4 connection for protective earth)
0,8

Standards and approvals


A ■ Standards: EN 60335-1, CE
160 4 3
■ Approvals:
0,6

VDE, UL, CSA, CCC, EAC are applied for


Optional
120
100
■ Additional shaft seal see page 88
3 2
0,4

80
0,2

40

1 1
0 25 50 75 100 125 150 cfm
pfs

qV 50 100 150 200 250 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

34 Fans and blowers for solid fuel heating systems · Edition 2022-06
R3G150AA03** / R3G150AC01**

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 1~200-240, 50/60Hz m3/h rpm W A °C kg
Type Part number Fan type

Cable
R3G150AA0301 design ❶ 145 2530 16 0.17
❷ 145 2540 16 0.17
VSW0150XSLBS M3G 055-AI A ❸ 145 2600 14 0.16
-25...+60 1.25

R3G150AA0305 Plug ❹ 145 2650 13 0.15


design

Cable
R3G150AC0101 design ❶ 275 2803 29 0.30
❷ 275 2770 30 0.30
VSW0150XSLCS M3G 055-BD B ❸ 275 2796 29 0.30
-25...+60 1.45

R3G150AC0105 Plug ❹ 275 2830 27 0.29


design

Induced draft fan


Subject to changes.

Technical drawing Dimensions in mm

d c±1.5 76 25° Connection


b No. Function Color
1 N blue
2 PE green/yellow
3 L black
4x90

4 0-10V/PWM black
°

5 GND white
Ø165.3
Øe

Øa

6 Tacho red

Dimensions
4xØ4.5
VSW0150XSLBS VSW0150XSLCS
450±20

Ø1

R3G150AA03** R3G150AC01**
58

a 152 148
b 20 42
c 31,5 53,5
d 87 108
e 116 119

12 3 4 5 6 Wieland
Wieland 93.031.3253.0
93.032.3353.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 35
DC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 150

Heat output range1


■ 10 – 24kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 20
Induced draft fan

■ Insulation class: "B"


■ Mounting position: any
■ Condensate discharges: none, open rotor
from page 86 Scroll dimensions ■ Mode of operation:
page 90 Electrical connections J5) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Technical features: Tach output;
Control input 0-10VDC / PWM; Reverse
polarity and locked-rotor protection;
in H2O
Pa

Motor current limitation;


Line undervoltage detection; Soft start
450
1,8

■ Cable exit: variable


■ Protection class: I
400
1,6

Standards and approvals


B
■ Standards: EN 60335-1, CE
350
1,4

Optional
300 2 ■ Additional shaft seal see page 88
1,2

250
1,0

200
0,8

150
0,6

1
100
0,4

1
50
0,2

0 25 50 75 100 125 150 cfm


pfs

qV 40 80 120 160 200 240 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

36 Fans and blowers for solid fuel heating systems · Edition 2022-06
R1G150AA63**

Perm. ambient temperature


Characteristic Curve*

Sound pressure level

Min. back pressure


Max. current draw
Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 24 V DC, Nominal voltagesbereich 16-28 V DC m3/h rpm W A db(A) Pa °C kg
Type Part number Fan type

Cable
R1G150AA6301 design ❶ 290 3030 31 1.40 66
A ❷ 290 3110 29 1.30 66
VSW0150XULCS M1G 055-BD 0 -25...+50 1.3
B ❶ 180 3190 26 1.20 67
R1G150AA6305 Plug ❷ 180 3360 22 1.00 67
design

Subject to changes. * A measured without scroll housing. B measured with scroll housing

Induced draft fan


Technical drawing Dimensions in mm

108 53.5±1.5 76 25° Connection


42 No. Function Color
1 GND blue
2 unlined
3 UN + 24 VDC red
4x90

4 Tach white
°

5 unlined
Ø165.3
Ø119

Ø148

6 0-10 VDC yellow

4xØ4.5
450±20

Ø1
58

12 3 4 5 6 Wieland
Wieland 93.031.3253.0
93.032.3353.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 37
EC centrifugal blowers (exhaust air)
for solid fuel heating systems, single inlet, Ø 150

Heat output range1


■ 10 – 24kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
■ Housing: Hot-dip aluminised sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
Induced draft fan

■ Type of protection: IP 54
■ Insulation class: "B"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none, open rotor
page 91, 93 Electrical connections H4), C)
■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Technical features:
See electrical connections p. 91 and 93
Pa

in H2O

■ EMC:
Interference emission acc. EN 61000-6-3
1,0

Interference immunity acc. EN 61000-6-2


240
Harmonics acc. EN 61000-3-2/3
A ■ Touch current: < 3,5mA acc. IEC 60990
(Test circuit, illustration 4)
200 ■ Cable exit: variable
0,8

■ Protection class: I (if customer has provided


connection for protective earth)
160 Standards and approvals
3
0,6

■ Standards: EN 60335-1, CE;


UKCA on request
120 ■ Approvals:
VDE, UL, CSA, CCC, EAC are applied for
0,4

Optional
80 2 ■ Additional shaft seal see page 88
0,2

40

1
0 10 20 30 40 50 60 70 80 cfm
pfs

qV 20 40 60 80 100 120 140 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and 1Heat output range
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

38 Fans and blowers for solid fuel heating systems · Edition 2022-06
G3G150DA03**

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 1~200-240VAC, 50/60Hz m3/h rpm W A db(A) °C kg
Type Part number Fan type

Cable
G3G150DA0301 design
❶ 149 2535 16 0.17
❷ 149 2545 16 0.17
VPW0150XSLBS M3G 055-AI A ❸ 149 2585 15 0.16
66 -25...+60 2.0
❹ 149 2635 14 0.16
Plug
G3G150DA0305 design

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

137
149 8.6 Ø80
P9 P11
32 P10 P12

Connection Z
No. Function Color
118.2

1 N blue
2 PE green/yellow
62

3 L black
Ø116

P2 4 0-10V/PWM yellow
P1
P6 5 GND blue
P3 P5
87

P4 6 Tacho white
P7
P8
450±20

52
85±10
6

P X Y
85 94.2
1 -24.7 -100.6
137 2 -20.8 -87.1
149
P9 P11
8.6 Ø80 3 -34.3 -97.8
32 P10 P12 4 -30.4 -84.4
5 -49.0 97.3
6 -41.6 85.4
7 -57.5 92.0
118.2

8 -50.1 80.1
62

9 120.3 49.4
Ø116

10 108.5 41.9
P2
P1 11 114.9 57.8
P6
P3 P5 12 103.1 50.3
90.4

1 P4
2 P7
3 P8
4
5
6 52
85 94.2

Fans and blowers for solid fuel heating systems · Edition 2022-06 39
EC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 160

Heat output range1


■ 10 – 24kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 54
Induced draft fan

■ Insulation class: "B"


■ Mounting position: any
■ Condensate discharges: none, open rotor
from page 86 Scroll dimensions ■ Mode of operation:
page 91, 93 Electrical connections H4), C) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Technical features:
See electrical connections p. 91 and 93
■ EMC:
1,4 in H2O
Pa

360 Interference emission acc. EN 61000-6-3


Interference immunity acc. EN 61000-6-2
A Harmonics acc. EN 61000-3-2/3
320 ■ Touch current: < 3,5mA acc. IEC 60990
4
(Test circuit, illustration 4)
1,2

■ Cable exit: variable


280
■ Protection class: I (if customer has provided
3 connection for protective earth)
1,0

240
Standards and approvals
■ Standards: EN 60335-1, CE
200 ■ Approvals:
0,8

VDE, UL, CSA, CCC, EAC are applied for


160 2 Optional
0,6

■ Additional shaft seal see page 88


120
0,4

80
0,2

40

1
0 20 40 60 80 100 120 140 cfm
pfs

qV 40 80 120 160 200 240 m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

40 Fans and blowers for solid fuel heating systems · Edition 2022-06
R3G160AE01**

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 1~200-240VAC, 50/60Hz m3/h rpm W A db(A) °C kg
Type Part number Fan type

Cable
R3G160AE0101 design ❶ 305 2600 40 0.33
❷ 305 2650 40 0.33
VSW0160XSLCS M3G 055-BD A ❸ 305 2670 38 0.27
66 -25...+60 1.55

R3G160AE0105 Plug ❹ 305 2740 35 0.26


design

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

108 49.5±1.5
47.
40 5 Connection
Ø1 No. Function Color
98 1 N blue
2 PE green/yellow
3 L black
4 0-10V/PWM yellow
5 GND blue
Ø160

4x90°
Ø210
Ø119

6 Tacho white
450±20

4xØ4.5

Wieland 1 2 3 4 5 6 Wieland
93.032.3353.0 93.031.3253.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 41
EC centrifugal fans (exhaust air)
for solid fuel heating systems, single inlet, Ø 180

Heat output range1


■ 25 – 50kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 54
Induced draft fan

■ Insulation class: "B"


■ Mounting position: any
■ Condensate discharges: none, open rotor
from page 86 Scroll dimensions ■ Mode of operation:
page 91, 93 Electrical connections H4), C) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Technical features:
See electrical connections p. 91 and 93
■ EMC:
Pa

in H2O

Interference emission acc. EN 61000-6-3


Interference immunity acc. EN 61000-6-2
Harmonics acc. EN 61000-3-2/3
■ Touch current: < 3,5mA acc. IEC 60990
(Test circuit, illustration 4)
B ■ Cable exit: variable
■ Protection class: I (if customer has provided
connection for protective earth)
4 Standards and approvals
■ Standards: EN 60335-1, CE
■ Approvals:
VDE, UL, CSA, CCC, EAC are applied for
A 3
Optional
4
■ Additional shaft seal see page 88
3

1
cfm
pfs

qV m3/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

42 Fans and blowers for solid fuel heating systems · Edition 2022-06
R3G180AH01** / R3G180AJ11**

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 1~200-240VAC, 50/60Hz m3/h rpm W A °C kg
Type Part number Fan type

Cable
R3G180AH0101 design ❶ 295 2150 25 0.28
❷ 295 2150 25 0.28
VSW0180XSLCS M3G 055-BD A ❸ 295 2220 23 0.26
-25...+50 1.65

R3G180AH0105 Plug ❹ 295 2285 20 0.24


design

Cable
R3G180AJ1101 design ❶ 440 2660 60 0.55
❷ 440 2635 60 0.52
VSW0180XSLES M3G 055-CF B ❸ 440 2685 59 0.50
-25...+50 1.90

R3G180AJ1105 Plug ❹ 440 2730 56 0.49


design

Induced draft fan


Subject to changes.

Technical drawing Dimensions in mm

d c±1.5
47.
b 5 Connection
Ø1 No. Function Color
98 1 N blue
2 PE green/yellow
3 L black
4 0-10V/PWM yellow
5 GND blue
4x90°
Ø210
Øa
Øe

6 Tacho white

Dimensions
VSW0180XSLCS VSW0180XSLES
450±20

R3G180AH01** R3G180AJ11**
4xØ4.5
a 180 180
b 26 45
c 44,5 54,5
d 108 108
e 119 119

Wieland 1 2 3 4 5 6 Wieland
93.032.3353.0 93.031.3253.0

Fans and blowers for solid fuel heating systems · Edition 2022-06 43
EC centrifugal blowers (exhaust air)
for solid fuel heating systems, single inlet, Ø 180

Heat output range1


■ 25 – 50kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
■ Housing: Hot-dip aluminised sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
Induced draft fan

■ Type of protection: IP 54
■ Insulation class: "B"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none, open rotor
page 91, 93 Electrical connections H4), C)
■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Maintenance-free ball bearings
■ Max. exhaust gas temperature:
Continuous operation 250°C
■ Technical features:
A See electrical connections p. 91 and 93
Pa

2,4 in H2O

■ EMC:
600 Interference emission acc. EN 61000-6-3
Interference immunity acc. EN 61000-6-2
Harmonics acc. EN 61000-3-2/3
■ Touch current: < 3,5mA acc. IEC 60990
500
2,0

(Test circuit, illustration 4)


■ Cable exit: variable
4
■ Protection class: I (if customer has provided
connection for protective earth)
400
1,6

Standards and approvals


3
8 ■ Standards: EN 60335-1, CE;
UKCA on request
300
1,2

7 ■ Approvals:
VDE, UL, CSA, CCC, EAC are applied for

12 Optional
200
0,8

11
■ Additional shaft seal see page 88
6

16
100 10
0,4

15

14

13 9 5
0 20 40 60 80 100 120 140 160 180 cfm
pfs

qV 50 100 150 200 250 300 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and 1Heat output range
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

44 Fans and blowers for solid fuel heating systems · Edition 2022-06
G3G180FJ11** / G3G180GJ11**

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 1~200-240VAC, 50/60Hz m3/h rpm W A db(A) °C kg
Type Part number Fan type

Cable
G3G180FJ1101 design ❶ 340 2690 55 0.50 74
❷ 340 2725 52 0.48 70
VPW0180XSLES ❸ 340 2810 46 0.44 66
❹ 340 2895 39 0.38 64
Plug ❺ 340 2500 44 0.40 72
G3G180FJ1105 ❻ 340 2500 40 0.37 67
design
❼ 340 2500 32 0.31 63
❽ 340 2500 25 0.25 61
M3G 055-CF A ❾ 340 2000 22 0.21 66
-25...+60 2.9
❿ 340 2000 20 0.19 62
Cable ⓫ 340 2000 16 0.16 57
G3G180GJ1101 design
⓬ 340 2000 13 0.13 55
⓭ 340 1500 9 0.09 59

Induced draft fan


VPW0180XSLES ⓮ 340 1500 9 0.08 55
⓯ 340 1500 7 0.07 50
G3G180GJ1105 Plug ⓰ 340 1500 5 0.05 48
design

Subject to changes.

Technical drawing Dimensions in mm

174
Ø100 Connection Z
a 17 17
50 P9 P11 No. Function Color
P12
P10 1 N blue
A
2 PE green/yellow
3 L black
134.5

4 0-10V/PWM yellow
P6
5 GND blue
74.5

P5
6 Tacho white
Ø119

P7
P8

P2 Detail A P X Y
105

P1
G3G180GJ11** 1 -84.9 -88.4
450±20

P3
85±10

2 -75 -78.5
6

P4
101 115.3 66 3 -92 -81.3
4 -82 -71.4
5 16.5 134
174 6 16.5 120
Ø100 7 6.5 134
a 17 17
50 P9 P11 8 6.5 120
P10 P12 9 153 -5
A
10 139 -5
11 153 5
134.5

12 139 5
P6
74.5

P5
Ø119

Dimensions
P7
P8 VPW0180XSLES VPW0180XSLES
G3G180FJ11** G3G180GJ11**
105

1 P2
2
3
P1 a 186 223
4 P3
5
6 P4 101 115.3 66

Fans and blowers for solid fuel heating systems · Edition 2022-06 45
EC circulation blower
for solid fuel heating systems, Ø 210

Heat output range1


■ 50 – 150kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44,
Induced draft fan

depending on installation and position


■ Insulation class: "B"
■ Mounting position: any
from page 86 Scroll dimensions ■ Condensate discharges: none
page 91, 93 Electrical connections H4), C) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Hybrid bearings
■ Technical features:
Tach output; Control input 0-10VDC / PWM;
Over-temperature protected electronics /
motor; Output 10 VDC, max. 10 mA
■ EMV:
in. wg
Pa

A 4 Interference emission acc. EN 61000-6-4


Interference immunity acc. EN 61000-6-2
500
■ Touch current: < 3,5mA acc. IEC 60990
2

(Test circuit, illustration 4)


3 ■ Cable exit: variable
1.8

■ Protection class: I (if customer has provided


connection for protective earth)
400
1.6

Standards and approvals


■ Standards:
1.4

EN 60034-1; EN 60204-1; EN 60335-1; CE


300
1.2

2
1

200
0.8
0.6

100
0.4
0.2

0 50 100 150 200 250 300


1 cfm
pfs

qv 100 200 300 400 500 m³/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

46 Fans and blowers for solid fuel heating systems · Edition 2022-06
R3G210AE5310

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 230 VAC, 50 Hz m3/h rpm W A °C kg
Type Part number Fan type

❶ 605 3050 160 1.30


with ❷ 470 3055 160 1.30
VSW0210XSNEZ R3G210AE5310 motor pro- M3G074-CF A ❸ 365 3195 139 1.14
-25...+55 4.3
tection hood
❹ 240 3295 119 0.99

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

Connection X
No. Function Color
1 N blue
2 PE green/yellow
3 L black
4 GND blue
5 Tacho white
4x90°
Ø142

Ø210
Ø245

6 0-10V/PWM yellow
450+20

4 30 X
Ø7.5 Ø7
114.6 42.7±1.5
Ø230

X
1 4
2 5
3 6

Fans and blowers for solid fuel heating systems · Edition 2022-06 47
EC centrifugal fans (exhaust air)
for solid fuel heating systems, backward curved, single inlet, Ø 250

Heat output range1


■ 100 – 250kW
Material/surface
■ Impeller: Corrosion resistant sheet steel
Characteristics
■ Direction of rotation: counterclockwise,
seen on rotor
■ Type of protection: IP 20
Induced draft fan

■ Insulation class: "F"


■ Mounting position: Shaft horizontal or rotor
on bottom; rotor on top on request
from page 86 Scroll dimensions ■ Condensate discharges: Rotor-side
page 91, 93 Electrical connections H4), C) ■ Mode of operation:
More at www.ebmpapst.com Continuous operation (S1)
■ Bearings: Hybrid bearings
■ Technical features: PFC (active);
Tach output; Control input 0-10VDC / PWM;
Over-temperature protected electronics /
motor; Output 10 VDC, max. 10 mA
■ EMC:
in wg
Pa

Interference emission acc. EN 61000-6-3


1600 Interference immunity acc. EN 61000-6-2
Harmonics acc. EN 61000-3-2/3
■ Touch current: < 3,5mA acc. IEC 60990
6

(Test circuit, illustration 4)


A ■ Cable exit: variable
■ Protection class: I (if customer has provided
5

1200 4 connection for protective earth)


Standards and approvals
■ Standards: EN 60335-1; CE
4

3 ■ Approvals: UL, CSA


800
3

2
2

400
1

0 100 200 300 400 500 600


1
cfm
P fs

qv 200 400 600 800 1000 m³/h

Air performance measured as per: ISO 5801, Installation category A, without scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at
1m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed 1Heat output range
and may vary depending on the installation situation. With any deviation to the standard setup, the specific approx. data; heat output depends on the specific system
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff. conditions.

48 Fans and blowers for solid fuel heating systems · Edition 2022-06
R3G250BE04H1

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Air flow

Weight
Speed
Motor
Nominal voltage 1~200-277VAC, 50/60Hz m3/h rpm W A °C kg
Type Part number Fan type

❶ 1155 3400 500 2.30


Cable ❷ 955 3500 500 2.30
VSC0250XSPGZ R3G250BE04H1 design
M3G084-DF A ❸ 750 3500 477 2.08
-25...+50 8.5
❹ 485 3500 365 1.60

Subject to changes.

Induced draft fan


Technical drawing Dimensions in mm

152.7 67.5 Ø300


57.5 Ø275 Connection
7 Ø10 (6x) No.
① PVC AWG18
② PVC AWG22
6x6

Ø188.5

Ø250

600+20
85±10
8

Fans and blowers for solid fuel heating systems · Edition 2022-06 49
Fans and blowers for solid fuel heating systems

Convection heat

50
Convection heat

Product overview
Dimensions in mm Type Part number Page

Centrifugal fans:

Ø 108 VHS0108XSHCZ 55667.27010 54


Ø 108 VHS0108XQFFS 55460.97630 56
Ø 108 VHS0108XQFFZ 55461.22850 58
Ø 120 VHS0120XQFHZ 55460.96461 60
Ø 120 VHD0120XSLDS D3G120AA0311 62
Ø 120 VHD0120X2MCS D2E120AA0104 64
Ø 175 VBS0175R2LDZ R2E175RA5201 66

Tangential fans:

Ø 60 VTS0060XQFFS 55411.20400 68
Ø 60 VTS0060XQFHZ 55412.60600 68
Ø 60 VTS0060XUECS auf Anfrage 70
Ø 60 VTS0060XUECS auf Anfrage 70

Convection heat
Ø 65 VTS0065XQFFS 55416.30108 72
Ø 65 VTS0065XQFHS 83315.00001 72
Ø 65 VTS0065XQFHS 55416.40010 72
Ø 65 VTS0065XUECZ 55668.49110 74
Ø 65 VTS0065XUECZ 55668.49111 74
Ø 65 VTS0065XUECZ 55668.49112 74

The fans and blowers from convection heat are used,


for example, in pellet stoves.

Fans and blowers for solid fuel heating systems · Edition 2022-06 51
Fans and blowers for solid fuel heating systems

Convection heat

An infinitely adjustable, comfortable climate

Convection heat is a convenient function of stoves and chimney trays. It ensures The convection heat sector likes to use tangential
that the warm air in a room is evenly distributed and warmed up more quickly. blowers. Centrifugal fans are particularly suitable
Normally, a stove is heated mainly by radiated heat. As warm air rises and colder for conveying very large quantities of heat. Tan-
air drops, it takes a while for the warm air to warm up the entire room. gential blowers are characterized by the fact that
they generate a laminar and wide air flow becau-
A fan helps to accelerate this process. To do this, it conveys the cooler air via se of their design. They are also durable and ope-
the hot surfaces of the stove and conveys it either directly into the room or into rate extremely quietly. EC tangential blowers
special ventilation ducts. Thanks to the combination of radiated and ­convection from ebm-papst are very economical thanks to
heat generated in this way, users can quickly benefit from pleasant heat through­ an efficient motor. Since they can be controlled
out the entire room. steplessly, the consumer can use them to adjust
the air performance to their needs, creating a
Convection heat

very pleasant atmosphere for them.

Comparison characteristic curves Centrifugal fans / Tangential fans


in wg
in wg

Pa
Pa

VHS0108XSHCZ VTS 0060


90
VHS0108XQFFS VTS 0060 with EC-Motor
600
VHS0108XQFFZ VTS 0065
VHS0120XQFHZ 80 VTS 0065 with EC-Motor
VHD0120XSLDS
0.3

500 VHD0120X2MCS 70
2

VBS0175R2LDZ
60
400 B
C
50
0.2

B
300 A
40
B
1

200 30
A B C
0.1

20

100 A
10
A

0 100 200 300 cfm 0 100 200 cfm


P fs
P fs

qv 100 200 300 400 500 m³/h qv 100 200 300 400 m³/h

52 Fans and blowers for solid fuel heating systems · Edition 2022-06
Size, performance and cost-effectiveness

perfectly combined

Wood pellet and wood chip heating systems The advantages of fans from ebm-papst
have very special requirements: in solid-fuel heating technology:
The air flows must be provided economically in
each operating state and irrespective of the hea- Suitable for use in intake and exhaust air and for distribution of warm air
ting power. In addition, there is little space in the
stoves. ebm-papst offers the right AC and EC fans Low noise emissions
to overcome these challenges. They are tailored
Cost-effective operation
to different performance classes and equipped
with fan impellers optimized for biomass appli-
Robust and compact design
cations. Due to their compact design, they are
robust, durable and space-saving. This facilita-
Fan impellers that are adapted to the special requirements
tes having the optimum size, performance and of biomass boilers
cost-effectiveness in any application.

Convection heat
Efficient,
 speed-controlled EC technology for optimum fuel utilization

Fans and blowers for solid fuel heating systems · Edition 2022-06 53
EC centrifugal blowers (ambient air)
VHS 108

Material/surface
■ Housing: Hot-dip aluminised sheet steel
■ Impeller: Hot-dip aluminised sheet steel
Characteristics
■ Efficient EC motor
■ Speed control via PWM interface possible
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 00
■ Insulation class: "I.Cl. H"
■ Mounting position:
from page 86 Scroll dimensions
any, except motor overhead
from page 90 Electrical connections ■ Mode of operation:
More at www.ebmpapst.com
Continuous operation (S1)
■ Max. fluid temperature 155°C
Convection heat

■ Design:
Motor anti-vibration mounted
■ Bearings: Maintenance-free ball bearings
■ Protection class: I
in H2O
Pa

■ Mains connector X, interface connector W


600 and interface see from page 90

A Standards and approvals


■ Standards: EN 60335-1, CE;
500 EAC & UKCA on request
2

400
1.5

300
1

200
0.5

100

0 20 40 60 80 100 120 cfm


pfs

qV 50 100 150 200 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

54 Fans and blowers for solid fuel heating systems · Edition 2022-06
VHS 108

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Speed free air flow

Max. current draw


Max. input power
Air flow

Weight
Nominal voltage 230VAC, 50Hz m3/h rpm W A db(A) °C kg
Type Part number

VHS0108XSHCZ 55667.27010 A 198 2800 55 0.45 – +55 1.4

Subject to changes.

Technical drawing Dimensions in mm

Convection heat
184

61+1 ca. 17°


°
ca. 6
max. 178.5

Ø1
20 ±0,1
67.5±0.5

4 x Ø2.8
reading direction
Leserichtung
101+1

45°
Ø58

Ø60±0.5
)
° (=360°
4x90

max. 139 12+1

(95.5)

Fans and blowers for solid fuel heating systems · Edition 2022-06 55
AC centrifugal blowers (ambient air)
VHS 108

Material/surface
■ Housing: Hot-dip aluminised sheet steel
■ Impeller: Hot-dip aluminised sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 00
■ Insulation class: "I.Cl. H"
■ Mounting position:
Shaft horizontal, Outlet upwards.
More mounting positions on request.
■ Mode of operation:
from page 86 Scroll dimensions Continuous operation (S1)
from page 90 Electrical connections
■ Max. fluid temperature 250°C
More at www.ebmpapst.com
■ Design:
Convection heat

Motor anti-vibration mounted


■ Bearings: Ball bearings / sleeve bearings
■ Motor protection: Impedance protected
■ Protection class: I
in H2O
Pa

Standards and approvals


A
■ Standards: EN 60335-1, CE;
UKCA on request
250
1

200

150
0.5

100

50

0 20 40 60 80 cfm
pfs

qV 50 100 150 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

56 Fans and blowers for solid fuel heating systems · Edition 2022-06
VHS 108

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Speed free air flow

Max. current draw


Max. input power
Air flow

Weight
Nominal voltage 230VAC, 50Hz m3/h rpm W A db(A) °C kg
Type Part number

VHS0108XQFFS 55460.97630 A 148 2300 57 0.47 – +35 1.6

Subject to changes.

Technical drawing Dimensions in mm

Convection heat
Ø1
08
Ø11
0±0.1
max. 161

.1
±0
18
Ø1
53±0.5

30.3+1.0
max. 3
max. 87.5

-0.4

130
°

min. 14 8±1.5
90.5±1 56±1
max. 172 max. 131

Fans and blowers for solid fuel heating systems · Edition 2022-06 57
AC centrifugal blowers (ambient air)
VHS 108

Material/surface
■ Housing: Sheet steel, hot-dip aluminized
■ Impeller: Aluminum
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 00
■ Insulation class: "I.Cl. H"
■ Mounting position: Shaft horizontal,
more mounting positions on request
■ Mode of operation:
Continuous operation (S1)
from page 86 Scroll dimensions
■ Max. fluid temperature 180°C
from page 90 Electrical connections
More at www.ebmpapst.com
■ Design:
Motor anti-vibration mounted
Convection heat

■ Bearings: Ball bearings / sleeve bearings


■ Motor protection: Impedance protected
■ Protection class: I
Standards and approvals
in H2O
Pa

■ Standards: EN 60335-1, CE;


UKCA on request
A
250
1

200

150
0.5

100

50

0 20 40 60 80 cfm
pfs

qV 50 100 150 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

58 Fans and blowers for solid fuel heating systems · Edition 2022-06
VHS 108

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Speed free air flow

Max. current draw


Max. input power
Air flow

Weight
Nominal voltage 230VAC, 50Hz m3/h rpm W A db(A) °C kg
Type Part number

VHS0108XQFFZ 55461.22850 A 144 1870 58 0.5 – +45 1.6

Subject to changes.

Technical drawing Dimensions in mm

90°

Convection heat
X 45°

Ø 3.2 H12

4
12
Ø
0
Ø 11 Ø1
08
Z

170±0.5
approx. 1.5 approx. 1.5

97
59.5 +0.3
-0.7
63+1

approx. 1.5 approx. 1.5


78
60±0.5

62±0.5 162.5±0.5

grounding connector flat


140 max. 3 max.
blade terminal suitable for snap on contact 6.3-... DIN 46 247

Z X
6±1
(180° rotated)

Ø 4.5
31

Fans and blowers for solid fuel heating systems · Edition 2022-06 59
AC centrifugal blowers (ambient air)
VHS 120

Material/surface
■ Housing: Hot-dip aluminised sheet steel
■ Impeller: Hot-dip aluminised sheet steel
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 00
■ Insulation class: "I.Cl. H"
■ Mounting position:
Shaft horizontal, Outlet upwards.
More mounting positions on request.
■ Mode of operation:
from page 86 Scroll dimensions Continuous operation (S1)
from page 90 Electrical connections
■ Max. fluid temperature 250°C
More at www.ebmpapst.com
■ Design:
Convection heat

Motor anti-vibration mounted


■ Bearings: Ball bearings / sleeve bearings
■ Motor protection: TOP wired internally
■ Protection class: I
in H2O
Pa

Standards and approvals


■ Standards: EN 60335-1, CE;
A UKCA on request

300
1

200
0.5

100

0 20 40 60 80 100 cfm
pfs

qV 50 100 150 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

60 Fans and blowers for solid fuel heating systems · Edition 2022-06
VHS 120

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Speed free air flow

Max. current draw


Max. input power
Air flow

Weight
Nominal voltage 230VAC, 50Hz m3/h rpm W A db(A) °C kg
Type Part number

VHS0120XQFHZ 55460.96461 A 184 2300 90 0.8 – +58 1.8

Subject to changes.

Technical drawing Dimensions in mm

max. 142 max. 184

Convection heat
max. 12.5 61+1

45°
45°

0
Ø11
2.6

max. 179
2.6
Ø12
67.5±0.5

0±0.1

Ø7 Ø5 Ø7
(Ø58) 45°

Ø60±0.5
6

2.4 2.4

14±1.5 30
7

12±1

95.5

Fans and blowers for solid fuel heating systems · Edition 2022-06 61
EC centrifugal blowers (ambient air)
for solid fuel heating systems, dual inlet, Ø 120

Material/surface
■ Housing: Galvanised sheet steel
■ Impeller: Galvanised sheet steel
■ Rotor: Uncoated
Characteristics
■ Direction of rotation:
Clockwise, seen on rotor
■ Type of protection: IP 54
■ Insulation class: "B"
■ Mounting position: any
■ Condensate discharges: none (open rotor)
from page 86 Scroll dimensions ■ Mode of operation:
page 91 Electrical connections H4) Continuous operation (S1)
More at www.ebmpapst.com ■ Design: Motor anti-vibration mounted
on both sides
Convection heat

■ Bearings: Maintenance-free ball bearings


■ Technical features: Tach output;
Control input 0-10VDC / PWM;
Locked-rotor protection; Output 10VDC
max. 1,1mA; Line undervoltage detection;
in H2O
Pa

Over-temperature protected electronics /


500 motor; Soft start
2,0

A
■ Touch current: < 3,5mA acc. IEC 60990
(Test circuit, illustration 4)
■ Cable exit: variable
4
400 ■ Protection class: I
1,6

Standards and approvals


3
■ Standards: EN 60335-1, CE;
UKCA on request
300
1,2

200
0,8

100
0,4

1
0 40 80 120 160 200 240 280 cfm
pfs

qV 100 200 300 400 500 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

62 Fans and blowers for solid fuel heating systems · Edition 2022-06
D3G120AA0311

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Max. current draw 1)


Max. input power 1)

Min. back pressure


Operating point

Air flow

Speed 1)

Weight
Motor
Nominal voltage 1~230VAC, 50/60Hz m3/h rpm W A db(A) Pa °C kg
Type Part number

❶ 505 1950 83 0.74 58


❷ 505 2465 82 0.70 57
VHD0120XSLDS D3G120AA0311 M3G 055-BI A ❸ 505 2970 81 0.69 59
0 -25...+40 2.2
❹ 505 3245 66 0.57 60

Subject to changes. 1) Nominal data in operating point with maximum load and 230VAC

Technical drawing Dimensions in mm

Convection heat
162
79
63
64.5

170

Ø100
74

146
156

6
350+20 85 ±10

Fans and blowers for solid fuel heating systems · Edition 2022-06 63
AC centrifugal blowers (ambient air)
for solid fuel heating systems, dual inlet, Ø 120

Material/surface
■ Housing: Galvanised sheet steel
■ Impeller: Galvanised sheet steel
■ Rotor: Uncoated
Characteristics
■ Direction of rotation:
Clockwise, seen on rotor
■ Type of protection: IP 44,
depending on installation and position
■ Insulation class: "F"
■ Mounting position: any
from page 86 Scroll dimensions
■ Condensate discharges: none
page 93 Electrical connections A1) ■ Mode of operation:
More at www.ebmpapst.com
Continuous operation (S1)
■ Design: Motor anti-vibration mounted
Convection heat

on both sides
■ Bearings: Maintenance-free ball bearings
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
in H2O
Pa

(test circuit, illustration 4)


■ Cable exit: variable
320 ■ Protection class: I (if customer has provided
A
connection for protective earth)
1,2

280 Standards and approvals


4 ■ Standards: EN 60335-1, CE;
UKCA on request
1,0

240

200 3
0,8

160
0,6

120 2
0,4

80
0,2

40

1
0 20 40 60 80 100 120 140 160 180 200 220 cfm
pfs

qV 40 80 120 160 200 240 280 320 360 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

64 Fans and blowers for solid fuel heating systems · Edition 2022-06
D2E120AA0104

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Min. back pressure


Max. current draw
Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB db(A) Pa °C kg
Type Part number

❶ 375 1400 85 0.38 50


❷ 375 1905 76 0.33 51
VHD0120X2MCS D2E120AA0104 M2E 068-B A ❸ 375 2265 65 0.28
2.0/400
52
0 -25...+70 2.4
❹ 375 2500 58 0.25 53

Subject to changes.

Technical drawing Dimensions in mm

Convection heat
162
79
63
64.5

170

Ø100
74

146
156

6
85 ±10
350+20

Fans and blowers for solid fuel heating systems · Edition 2022-06 65
AC centrifugal blowers (ambient air)
backward curved, single inlet, Ø 175

Material/surface
■ Impeller: Plastic PA
■ Rotor: coated black
Characteristics
■ Direction of rotation:
Clockwise, seen on rotor
■ Type of protection: IP 44, depending on
installation and position acc. EN 60034-5
■ Insulation class: "F"
■ Mounting position: Shaft horizontal or rotor
on bottom; rotor on top on request
■ Condensate discharges: Rotor-side
from page 86 Scroll dimensions
■ Mode of operation:
page 93 Electrical connections A1), D)
Continuous operation (S1)
More at www.ebmpapst.com
■ Bearings: Maintenance-free ball bearings
Convection heat

■ Motor protection: TOP wired internally


■ Touch current: < 0.75mA acc. to IEC 60990
(test circuit, illustration 4)
■ Cable exit: variable
■ Protection class: I (if customer has provided
in wg
Pa

connection for protective earth)

300 Standards and approvals


1.2

■ Standards: EN 60335-1; CE

250
A
0.9

200 4

150 3
0.6

100

2
0.3

50

0 50 100 150 200 250


1 cfm
Pfs

qv 100 200 300 400 m³/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

66 Fans and blowers for solid fuel heating systems · Edition 2022-06
R2E175RA5201

Perm. ambient temperature


Characteristic Curve

Max. current draw


Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50 Hz m3/h rpm W A μF/VDB °C kg
Type Part number

❶ 450 2565 43 0.19


❷ 370 2480 45 0.20
VBS0175R2LDZ R2E175RA5201 M2E052 CA A ❸ 280 2450 46 0.21 1.5/400 -25...60 1.1
❹ 170 2500 45 0.20

Subject to changes.

Technical drawing Dimensions in mm

Convection heat
M4 (6x)
Ø132.8±0.2
Ø175
Ø72

61.3 Ø58±0.2
68.5±1
8
45 5±1
6

0+ 0
2 20

Fans and blowers for solid fuel heating systems · Edition 2022-06 67
Tangential blowers (ambient air)
VTS 0060

Material/surface
■ Housing: Hot-dip aluminised sheet steel
■ Impeller: Aluminum
Characteristics
■ Impeller diameter: 60 mm
■ Mounting position: horizontal
■ Permissible fluid temperature 0...+60 °C
■ Insulation class: "H"
Standards and approvals
■ Standards: EN 60335-1, CE;
EAC & UKCA on request
from page 86 Scroll dimensions
from page 89 Electrical connections
More at www.ebmpapst.com
Convection heat

Pa
pfs

qV m3/h
Pa

A B

A B
pfs

qV m3/h qV m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

68 Fans and blowers for solid fuel heating systems · Edition 2022-06
VTS 0060

Perm. ambient temperature*


Max. pressure increase
Characteristic Curve

Speed free air flow


Impeller lenght

Current draw
Input power
Air flow

Weight
Nominal voltage 230VAC, 50 Hz mm m3/h Pa W mA rpm °C kg
Type Part number

VTS0060XQFFS 55411.20400 A 240 170 63 38 290 1700 0...+60 1.40

VTS0060XQFHZ 55412.60600 B 300 230 60 50 350 1600 0...+60 1.70

Subject to changes. Technical data are valid at free air flow and rated voltage. * Higher ambient temperatures on request.

Technical drawing Dimensions in mm

Convection heat
e Dimensions
16

f f VTS0060XQFFS VTS0060XQFHZ
55411.20400 55412.60600
a 329 395
25
33

b 64 72
17
72

c 243 303
d 253 313
e 212 272
f 93 123

a
d b
61
36

c
3

Flat connector 6.3 x 0.8


96
83
50

56 3xØ2.4

Fans and blowers for solid fuel heating systems · Edition 2022-06 69
Tangential blowers (ambient air)
VTS 0060 with EC motor

Material/surface
■ Housing: Hot-dip aluminised sheet steel
■ Impeller: Aluminum
Characteristics
■ Electronics: integrated
■ Blower speed: variable via
0-10 V analogue voltage signal (Interface 26)
■ Impeller diameter: 60 mm
■ Mounting position: horizontal or vertical
with motor on bottom
■ Permissible fluid temperature 0...+60 °C
from page 86 Scroll dimensions
■ Insulation class: "H"
from page 89 Electrical connections ■ Type of protection: IP 20
More at www.ebmpapst.com ■ Protection class: 3; Operation with SELV
(safety extra low voltage)
Convection heat

Pa

Standards and approvals


■ Standards: EN 60335-1;
UKCA on request
pfs

qV 25 50 75 100 125 150 175 200 225 250 m3/h


Pa

A B

A B
pfs

qV 25 50 75 100 125 150 175 200 225 250 m3/h qV 25 50 75 100 125 150 175 200 225 250 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

70 Fans and blowers for solid fuel heating systems · Edition 2022-06
VTS 0060 with EC motor

Perm. ambient temperature*


Max. pressure increase
Characteristic Curve

Speed free air flow


Impeller lenght

Current draw
Input power
Air flow

Weight
Nominal voltage 24VDC mm m3/h Pa W mA rpm °C kg
Type Part number

VTS0060XUECS on request A 240 220 80 17 – 1800 0...+40 0.80

VTS0060XUECS on request B 300 280 80 19 – 1850 0...+40 0.85

Subject to changes. Technical data are valid at free air flow and rated voltage. * Higher ambient temperatures on request.

Technical drawing Dimensions in mm

e
Dimensions
16

f f

Convection heat
VTS0060XUECS VTS0060XUECS
on request on request
33

a 327 387
b 64,5 64,5
25

67
51

c 243 303
d 253 313
e 212 272
f 93 123
d b
51
36

c
3

96
83
50

56 3xØ2.4

GND N.C.
Hall out GND / Error
+18...28 VDC control voltage /
PWM 1-6 KHz

Fans and blowers for solid fuel heating systems · Edition 2022-06 71
Tangential blowers (ambient air)
VTS 0065

Material/surface
■ Housing: Hot-dip aluminised sheet steel
■ Impeller: Aluminum
Characteristics
■ Impeller diameter: 65 mm
■ Mounting position: horizontal
■ Permissible fluid temperature: 0...+60 °C
■ Insulation class: "H"
Standards and approvals
■ Standards: EN 60335-1, CE;
UKCA on request
from page 86 Scroll dimensions
page 89 Electrical connections
More at www.ebmpapst.com
Convection heat

Pa

90
80
70
60
50
40
30
20
10
pfs

qV 50 100 150 200 250 300 350 m3/h


Pa

90
80
B
70
60 A C
50
40
30
20 A B C
10
pfs

qV 50 100 150 200 250 300 350 m3/h qV 50 100 150 200 250 300 350 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

72 Fans and blowers for solid fuel heating systems · Edition 2022-06
VTS 0065

Perm. ambient temperature*


Max. pressure increase
Characteristic Curve

Speed free air flow


Impeller lenght

Current draw
Input power
Air flow

Weight
Nominal voltage 230VAC, 50 Hz mm m3/h Pa W mA rpm °C kg
Type Part number

VTS0065XQFFS 55416.30108 A 240 220 80 38 360 1200 0...+60 1.45

VTS0065XQFHS 83315.00001 B 300 354 83 66 530 2100 0...+60 1.75

VTS0065XQFHS 55416.40010 C 360 380 95 75 700 1500 0...+50 1.80

Subject to changes. Technical data are valid at free air flow and rated voltage. * Higher ambient temperatures on request.

Technical drawing Dimensions in mm

Convection heat
e Dimensions
f f
18
16

VTS0065XQFFS VTS0065XQFHS VTS0065XQFHS


55416.30108 55416.35280 55416.40010
33

a 331 400 456


b 65 73 73
17
25

72

c 242 302 362


d 259 319 379
e 212 272 332
f 106 136 166

a Flat connector 6.3 x 0.8


d b
61
48

c
3

108
90

56

64 3xØ2.4

Fans and blowers for solid fuel heating systems · Edition 2022-06 73
Tangential blowers (ambient air)
VTS 0065 with EC motor

Material/surface
■ Housing: Hot-dip aluminised sheet steel
■ Impeller: Aluminum
Characteristics
■ Electronics: integrated
■ Blower speed: variable via
0-10 V analogue voltage signal (Interface 26)
■ Impeller diameter: 65 mm
■ Mounting position: horizontal or vertical
with motor on bottom
■ Permissible fluid temperature: 0...+70 °C
from page 86 Scroll dimensions
■ Insulation class: "H"
page 89 Electrical connections ■ Type of protection: IP 20
More at www.ebmpapst.com ■ Protection class: 3; Operation with SELV
(safety extra low voltage)
Convection heat

Pa

Standards and approvals


■ Standards: EN 60335-1, CE;
UKCA on request
pfs

qV 50 100 150 200 250 300 m3/h


Pa

1600 A

1400 B

C
1200
A B C
pfs

qV 50 100 150 200 250 300 m3/h qV 50 100 150 200 250 300 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
1600 against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
protection
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
1400have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.
values

1200
74 Fans and blowers for solid fuel heating systems · Edition 2022-06
VTS 0065 with EC motor

Perm. ambient temperature*


Max. pressure increase
Characteristic Curve

Speed free air flow


Impeller lenght

Current draw
Input power
Air flow

Weight
Nominal voltage 24VDC mm m3/h Pa W mA rpm °C kg
Type Part number

VTS0065XUECZ 55668.49110 A 240 260 60 13 – 400-1500 0...+40 0.85

VTS0065XUECZ 55668.49111 B 300 320 60 14 – 400-1500 0...+40 0.90

VTS0065XUECZ 55668.49112 C 360 360 60 15 – 400-1500 0...+40 0.95

Subject to changes. Technical data are valid at free air flow and rated voltage. * Higher ambient temperatures on request.

Technical drawing Dimensions in mm

d
e 6

Convection heat
Dimensions
12

VTS0065XUECZ VTS0065XUECZ VTS0065XUECZ


55668.49110 55668.49111 55668.49112
12
32

a 331 391 451


67
51

b 64,5 64,5 64,5


c 242 302 362
d 284 344 404
e 272 332 392
a
b
51
48

2.8

22 67
51
94
34

108

GND N.C.
Hall out GND / Error
+18...28 VDC control voltage /
PWM 1-6 KHz

Fans and blowers for solid fuel heating systems · Edition 2022-06 75
Fans and blowers for solid fuel heating systems

Combustion air blower

76
Combustion air blower

Product overview
Dimensions in mm Type Part number Page
Ø 140 VHS0140X2MES G2E140AL4001 80
Ø 160 VHS0160X2MJS G2E160AY5091 82

Combustion air blower

Fans and blowers for solid fuel heating systems · Edition 2022-06 77
Fans for solid fuel heating systems

Combustion air blower

Wide range of sizes

Combustion air blowers convey air from the ebm-papst offers a wide range of centrifugal fans in various sizes, with both AC and
surroundings to stoves and heaters and convey EC technology. The fan impellers are generally forward-curved. The advantage of EC
this into the combustion chamber. This enables centrifugal fans is that their speed can be controlled. This means that the air volume
the biomass to be burned optimally. A perfect can always be optimally adapted to the requirements. If less heat is required, the sto-
mixture of air and fuel ensures hygienic com- ve runs at a low level – less fuel is burnt and the demand for air is reduced. If it is very
bustion of wood pellets or wood chips. This re- cold outside, the heating system runs at full speed by using more air to burn more
duces the formation of combustion residues to biomass. As it adapts optimally to the heating load, the fan operates efficiently and
a minimum. ensures optimum fuel utilization.

Do you want to selectively control the supply of combustion air, for example using
a vane anemometer? Then feel free to contact us. Together we will find the ideal
solution for your requirements.
Combustion air blower

Comparison characteristic curves


in wg
Pa

600

G2E160AY5091
500
2

400

300
1

200

G2E140AL4001

100

0 100 200 300 cfm


P fs

qv 100 200 300 400 500 600 m³/h

78 Fans and blowers for solid fuel heating systems · Edition 2022-06
Clean & efficient
combustion
Our fans and blowers ensure clean and efficient combustion
in solid fuel heating systems, through design and quality, and thus,
ultimately, that people can enjoy a cozy home.

At ebm-papst, we call that:

Combustion air blower

Fans and blowers for solid fuel heating systems · Edition 2022-06 79
AC centrifugal blowers (intake air)
for solid fuel heating systems, single inlet, Ø 140

Material/surface
■ Housing: Die-cast aluminium
■ Impeller: Galvanised sheet steel
■ Rotor: Partially cast in aluminium
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44
■ Insulation class: "B"
■ Mounting position: any
■ Condensate discharges: none
from page 86 Scroll dimensions ■ Mode of operation:
page 93 Electrical connections A1) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
(test circuit, illustration 4)
■ Cable exit: variable
■ Protection class: I
Pa

in H2O

Standards and approvals


Combustion air blower

■ Standards: EN 60335-1, CE;


UKCA on request
■ Approvals: CCC; EAC is applied for
A
Optional
■ Speed monitoring via Hall IC

cfm
pfs

qV m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

80 Fans and blowers for solid fuel heating systems · Edition 2022-06
G2E140AL4001

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Min. back pressure


Max. current draw
Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 1~230VAC, 50Hz m3/h rpm W A μF/VDB db(A) Pa °C kg
Type Part number
❶ 415 2100 111 0.48 62
VHS0140X2MES G2E140AL4001 M2E 068-CF A ❷ 415 2350 98 0.43
2.0/450
62
0 -25...+60 3.0

Nominal voltage 1~230VAC, 60Hz m3/h rpm W A μF/VDB db(A) Pa °C kg


Type Part number
❶ 340 2100 111 0.48 62
VHS0140X2MES G2E140AL4001 M2E 068-CF A ❷ 340 2350 98 0.43
2.0/450
62
100 -25...+40 3.0

Subject to changes.

Technical drawing Dimensions in mm

130 227
115 103
94 5
6,3

M4

Combustion air blower


105
120

92

175
450
248
Ø130-1

107

100

Fans and blowers for solid fuel heating systems · Edition 2022-06 81
AC centrifugal blowers (intake air)
for solid fuel heating systems, single inlet, Ø 160

Material/surface
■ Housing: Die-cast aluminium
■ Impeller: Galvanised sheet steel
■ Rotor: Partially cast in aluminium
Characteristics
■ Direction of rotation:
clockwise, seen on impeller
■ Type of protection: IP 44
■ Insulation class: "B"
■ Mounting position: any
■ Condensate discharges: none
from page 86 Scroll dimensions ■ Mode of operation:
page 93 Electrical connections A1) Continuous operation (S1)
More at www.ebmpapst.com ■ Bearings: Maintenance-free ball bearings
■ Motor protection: TOP wired internally
■ Touch current: < 0.75mA acc. to IEC 60990
(test circuit, illustration 4)
■ Cable exit: variable
■ Protection class: I
2,4 in H2O
Pa

600 Standards and approvals


A
Combustion air blower

■ Standards: EN 60335-1, CE;


4 UKCA on request
■ Approvals: CCC is applied for
500
2,0

Optional
3 ■ Speed monitoring via Hall IC

400
1,6

300
1,2

200
0,8

100
0,4

0 100 200 300 cfm


pfs

qV 100 200 300 400 500 m3/h

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without
protection against accidental contact. Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1m
distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and
may vary depending on the installation situation. With any deviation to the standard setup, the specifi c
values have to be checked and reviewed once installed or fi tted! For detailed information see page 94 ff.

82 Fans and blowers for solid fuel heating systems · Edition 2022-06
G2E160AY5091

Perm. ambient temperature


Sound pressure level
Characteristic Curve

Min. back pressure


Max. current draw
Max. input power
Operating point

Capacitor
Air flow

Weight
Speed
Motor
Nominal voltage 230VAC, 50Hz m3/h rpm W A μF/VDB db(A) Pa °C kg
Type Part number

❶ 600 2280 270 1.18 72


❷ 600 2480 227 0.98 70
VHS0160X2MJS G2E160AY5091 M2E 068-EC A ❸ 600 2620 192 0.83
6.0/400
68
100 -25...+60 4.2
❹ 600 2750 152 0.66 67

Subject to changes.

Technical drawing Dimensions in mm

130 227
115 103
94 5
6,3

M4

Combustion air blower


105
120

92

175
450
248
Ø130-1

107

100

Fans and blowers for solid fuel heating systems · Edition 2022-06 83
Fans and blowers for solid fuel heating systems

Additional information

84
Additional information

Contents
Page
Scroll dimensions 86
Additional shaft seal 88
Electrical connections EC tangential blowers 89
Electrical connections EC 90
Electrical connections AC 93
Electrical connections Hall IC 93
Technical parameters & scope 94

Additional information

Fans and blowers for solid fuel heating systems · Edition 2022-06 85
Scroll dimensions

Scroll dimensions for AC / EC centrifugal fans (recommended by ebm-papst)


Size A B C D E F G H J K M N P R
Ø 140 121 116 111 106 102 97 92 88 84 82 80 86 93 9
Ø 150/152 130 124 119 114 109 104 99 94 90 87 86 92 100 10
Additional information

Ø 160 139 132 127 122 116 111 106 100 96 93 92 98 107 11
Ø 180 156 149 143 137 131 125 119 113 108 104 103 110 120 12
Ø 210 182 174 167 160 152 146 139 132 127 121 120 128 140 14
Ø 250 218 209 200 192 182 175 167 158 152 145 144 154 168 19

Subject to changes.

86 Fans and blowers for solid fuel heating systems · Edition 2022-06
Scroll housing Scroll housing
without inlet nozzle with inlet nozzle

Distance between impeller and scroll housing/inlet nozzle (recommended by ebm-papst)


Size X Y Z R H
Ø 140 80-100 3-5 8-11 10 10
Ø 150/152 90-110 3-5 8-11 10 10

Additional information
Ø 160 100-120 3-5 8-11 10 10
Ø 180 110-130 3-5 8-11 12 12
Ø 210 120-135 3-5 8-11 12 12
Ø 250 140-160 3-5 8-11 12 12

Subject to changes.

Fans and blowers for solid fuel heating systems · Edition 2022-06 87
Additional shaft seal

As an option, ebm-papst offers an additional shaft seal for its


exhaust blowers. Whether for passive and low-energy houses or
condensing boiler applications - there are suitable solutions for all
these applications. Our developers have come up with something
very special here, especially for condensing boiler applications.

The illustration shows the individual components of this system.


By using a multi-stage design, not only the shaft is sealed, but also
the harsh environmental conditions are taken into account.
It thus offers a robust solution. The final suitability of the system
must be qualified and approved in the end device.

Shaft seal
X
Additional information

88 Fans and blowers for solid fuel heating systems · Edition 2022-06
Electrical connection EC
(11) Tangential blowers

1 supply voltage +18...28VDC Vcc

10K

2 speed output 1K
2 pulses per revolution

MMSZ4699T1
Uhigh = 12V HSO
Imax = 2mA

3 GND GND GND

100K
control voltage
4 PWM: 1...6kHz; Uhigh = 10V; Ulow = 0V 100K control voltage
or control voltage 0...10VDC
stop: U < 1.0V or PWM < 10%
start: U > 1.5V or PWM > 15%
open port --> motor stand still

In order to calculate a v 5 GND / error out (“active low“) GND / error


alid, stable speed signal
a multiple of 4 changes
of the hall signal have to
be measured. The mean
value of the measured 6 N.C.
time has to be used to
calculate the speed.
Customer circuit Connection Fan

Additional information

Fans and blowers for solid fuel heating systems · Edition 2022-06 89
Electrical connection EC
H1)

Technical Characteristics:

• PFC (passive)
• Output 10VDC max. 1,1mA
• Tach output
• Control input 0-10VDC / PWM
• Over-temperature protected electronics / motor

Notes on various control possibilities and their applications

Umin = 15V
Imax = L
Mains
brown +
10mA 50/60Hz N
blue -
PE
green/yellow

+
Voltage output
PWM U +10V max. 1.1mA
10K -
red
12V Lin/PWM control input
0-10VDC/PWM

yellow

GND 1µF

Counter
blue
Speed setting Speed Full Speed setting Tach output 1 pulse
Additional information

PWM 1 - 10kHz setting with speed 1V - 10V per revolution Isink max. 10mA
variable Controller white
resistance
680Ω
47V
100% PWM ->n=max 10V ->n=max
Alarm
approx. 10% PWM ->n=min approx. 1V ->n=min
< 10% PWM ->n=0 < 1V ->n=0
start up at > 14% start up at > 1.4V Speed display

Customer circuit Connection Fan

Line 1 Line 2
0-10V

Tacho
PWM
+10V

GND
PE
N
L

brown blue green/yellow red yellow blue white

Line Connection Color Assignment / function Line Connection Color Assignment / function
L brown Mains 50/60Hz, phase + 10V red Voltage output +10 V max. 1.1mA
1 N blue Mains 50/60Hz, neutral 0-10V / PWM yellow Control input (Impedance 100 kΩ)
2
PE green/yellow Protective earth GND blue GND
Tacho white Tach output: 1 pulse per revolution

90 Fans and blowers for solid fuel heating systems · Edition 2022-06
Electrical connection EC
H4)

Technical Characteristics:

• Control input 0-10VDC / PWM


• Output 10VDC max. 1,1mA
• Tach output
• Line undervoltage detection
• Locked-rotor protection
• Soft start
• Over-temperature protected electronics / motor

Customer circuit Connection Fan

Max. Speed L AC1


speed setting CON10 P
3 2 N 1.6AT AC2
CON11 N

1 - 10V PE
CON12
2 1 PE1

+10 V 1 3
3
Isink max. 1.1mA 2 4

10V/PWM
2
47k 47k
Speed setting with Speed setting with
1µF
GND
PWM 1 - 10kHz potentiometer 1
15V
Tacho 3 1
4

Additional information
3
680R 4 2
Imax = 10mA
ZMM47
2 2
10 K

12V
1 1
100% PWM ->n=max
10% PWM ->n=min
< 10% PWM ->n=0

Line Connection Color Assignment / function


CON10 L black Power supply 230VAC, 50 - 60Hz, see Type plate for voltage range
CON11 N blue Neutral conductor
CON12 PE green/yellow Protective earth
1 GND blue GND-Connection for control interface
2 0-10V / PWM yellow Control input 0-10V or PWM, electrically isolated
3 10V max. 1.1mA red Voltage output 10V / 1.1mA, electrically isolated, not short-circuit-proof
4 Tacho white Tach output: Open Collector, 1 pulse per revolution, electrically isolated

Fans and blowers for solid fuel heating systems · Edition 2022-06 91
Electrical connection EC
J5)

Technical Characteristics:

• Control input 0-10VDC / PWM


• Tach output
• Motor current limitation
• Reverse polarity and locked-rotor protection
• Soft start

Customer circuit Connection Fan / Motor


Full Speed Speed setting with
speed setting potentiometer UN
1 UB
1 2 1 +24/48VDC

1-10V
2 4 PWM/LIN
10V -> n = max 2 RE>100K
1V -> n = min 2
<1V -> n = 0 10K
Safe start-up 12V
at Unom -30%
from 4V Ucontr. 4
DUE
3
680R

DUE
47V
Speed Setting of values with GND
setting with temperatue controller 4 GND1
PWM 1-10kHz Reverse-polarity
protection
Additional information

1 1
33K
P

OUT
2 T 2

50003-1-0174
N

12V
4 4
100% PWM -> n = max T<10°C -> n = 0
10% PWM -> n = min T>45°C -> n = max
<10% PWM -> n = 0
Safe start-up
at Unom -30%
from 40% PWM

Line Connection Color Assignment / function


1 UN +24/48 VDC red Power supply 24/48VDC, maximum ripple ± 3,5%
2 PWM/LIN yellow Control input Re >100K
3 Tach white Tach output, 3 pulses per revolution, Isink max. = 10mA
4 GND blue Reference ground

92 Fans and blowers for solid fuel heating systems · Edition 2022-06
Electrical connection Electrical connection
AC Hall IC
A1) / B) C) / D)

A1) Single-phase capacitor motor C) Speed monitoring with EC fans


with TOP wired internally
VCC

Pull up
L PE N U1 = blue

R4
C
U2 = black R3
white
Z = brown 680R
U1 U2 Z OK1
= green/yellow 5 1

D1
TW 4 2

blue

GND
B) Shaded pole motor
with TOP wired internally
Fan connections: white (OUT): Speed signal
blue (IN): Ground connection

L PE N L = blue Specification from ebm-papst:


N = brown Isinkmax = 10mA (by transistor in OK1)
= green/yellow VCCmax = 40V (external supply to be provided by customer)
Pull up resistor = P
 ay attention to power loss
of the resistors in dimensioning!

TW

D) Speed monitoring with AC fans

Additional information
VCC

red
Pull up
R1

Fan white

black

GND

Fan connections: red (IN): DC-Voltage


white (OUT): Speed signal
black (IN): Ground connection

Specification from ebm-papst:


VCC = 5VDC (external supply to be provided by customer)
Pull up resistor = 4.5 kΩ

Fans and blowers for solid fuel heating systems · Edition 2022-06 93
Technical parameters & scope
High standards for all ebm-papst products
Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your
application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based
on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work
out the best solution for your specific application.

General performance parameters Service life


Any deviations from the technical data and parameters The service life of ebm-papst products
described here are listed on the product-specific data sheet. depends on two major factors:

Type of protection ■ The service life of the insulation system


The Type of protection is specified ■ The service life of the bearing system
in the product-specific data sheets.
The service life of the insulation system mainly depends on volta-
Insulation class ge level, temperature and ambient conditions, such as humidity
The insulation class is specified and condensation. The service life of the bearing system depends
in the product-specific data sheets. mainly on the thermal load on the bearing. The majority of our pro-
ducts use maintenance-free ball bearings for any mounting positi-
Mounting position on possible. The service life L10 of the ball bearings can be taken
The mounting position is specified as approx. 40,000 operating hours at an ambient temperature of
in the product-specific data sheets. 40°C, yet this estimate can vary according to the actual ambient
conditions.
Condensate discharge holes We will gladly provide you with a lifetime calculation taking into
Information on the condensate discharge holes account your specific operating conditions.
is provided in the product-specific data sheets.
Motor protection / thermal protection
Mode of operation Information on Motor protection and thermal protection is provi-
The mode of operation is specified ded in the product-specific data sheets.
in the product-specific data sheets. Depending on motor Type and field of application, the following
protective Characteristics are realised:
Protection class
The Protection class is specified ■ Thermal overload protection (TOP), either in-circuit or external
Additional information

in the product-specific data sheets. ■ PTC with electronic diagnostics


■ Impedance protection
■ Thermal overload protection (TOP) with electronic diagnostics
■ Current limitation via electronics

If an external TOP is connected, the customer has to make sure to


Information on ErP directive for hot air blowers connect a conventional trigger device for switching it off.
With implementation of the ErP directive, more stringent e­ fficiency Products without fitted TOP and without protection against im-
requirements apply in two stages as of 2013 and 2015 for fans in proper use, a Motor protection complying with the valid standards
the power range between 125 W and 500kW. The corresponding has to be installed.
minimum efficiency values for the different Types of fan are stipu-
lated by the EU.
ebm-papst GreenTech EC fans already surpass the minimum values Mechanical strain / performance parameters
required by law. Users can recognise fans complying with the direc- All ebm-papst products are subjected to comprehensive tests com-
tive from the CE marking for example. Exceptions not subject to plying with the normative specifications. In addition to this, the
the directive include fans for conveying hot media at temperatures tests also reflect the vast experience and expertise of ebm-papst.
in excess of 100°C.

94 Fans and blowers for solid fuel heating systems · Edition 2022-06
Vibration test ­Standards
Vibration tests are carried out in compliance with Information on standards is provided
in the product-specific data sheets.
■ Vibration test in operation according to DIN IEC 68, parts 2-6
■ Vibration test at standstill according to DIN IEC 68, parts 2-6 EMC
Information on EMC standards is provided in the product-specific
Shock load data sheets. Complying with the EMC standards has to be estab-
Shock load tests are carried out in compliance with lished on the final appliance, as different mounting situations can
result in changed EMC properties.
■ Shock load according to DIN IEC 68, parts 2-27
Leakage current
Balancing quality Information on the leakage current is provided in the product-
Testing the balancing quality is carried out in compliance with specific data sheets.
Measuring is according to IEC 60990.
■ Residual imbalance according to DIN ISO 1940
■ Standard balancing quality level G 6.3 Approvals
In case you require a specific approval for your ebm-papst product
Should you require a higher balancing quality level for your (VDE, UL, EAC, CCC, CSA, etc.) please let us know.
specific application, please let us know and specify this when Most of our products can be supplied with the relevant approval.
ordering your product. Information on existing approvals is provided in the product-
specific data sheets.
Chemo-physical strain / performance parameters
Should you have questions about chemo-physical strain, Air performance measurements
please direct them to your ebm-papst contact. All air performance measurements are carried out on suction side
and on chamber test beds conforming to the specifications as per
Fields of application, industries and applications ISO 5801 and DIN 24163. The fans under test are installed in the

Additional information
Our products are used in various industries and applications: measuring chamber at free air intake and exhaust (installation
Ventilation, air-conditioning and refrigeration technology, clean category A) and are operated at nominal voltage, with AC also at
room technology, automotive and rail technology, medical and nominal frequency, and without any additional components such
laboratory technology, electronics, computer and office technolo- as guard grilles. As required by the standard, the air performance
gy, telecommunications, household appliances, heating, machines curves correspond to an air density of 1.2 kg/m3.
and plants, drive engineering. Our products are not designed for
use in the aviation and aerospace industry!

Legal and normative directives


The products described in this catalogue are designed, developed
and produced in keeping with the standards in place for the rele-
vant product and, if known, the conditions governing the relevant
fields of application.

Fans and blowers for solid fuel heating systems · Edition 2022-06 95
Technical parameters & scope

Measurement conditions for air and noise measurement Sound pressure level and sound level
ebm-papst products are measured under the following conditions: All acoustic values are established according to ISO 13347, DIN
45635 and ISO 3744/3745 to accuracy class 2 and given in A-rated
■ A xial and diagonal fans in Direction of rotation “V” form.
in full nozzle and without guard grille When the sound pressure level (Lp) is measured, the microphone is
■ Backward curved centrifugal fans, free-running on the intake side of the fan being tested, usually at a distance of 1m
and with inlet nozzle on the fan axis.
■ Forward curved single and dual inlet centrifugal fans To measure the sound power level (Lw), 10 microphones are distri-
with housing buted over an enveloping surface on the intake side of the fan being
tested (see graphic). The sound power level measured can be roug-
Noise measurements hly calculated from the sound pressure level by adding 7 dB.
All noise measurements are carried out in low-reflective test rooms
with reverberant floor. Thus the ebm-papst acoustic test chambers Measuring confi guration
meet the requirements of precision class 1 according to DIN EN ISO as per ISO 13347-3 respectively DIN 45635-38:
3745. For noise measurement, the fans being tested are placed in a
reverberant wall and operated at nominal voltage (for AC, also at 10 measuring points
nominal frequency) without additional attachments such as the d≥D
­guard grille. h = 1.5d ... 4.5d
Measurement area S = 6d2 + 7d (h + 1.5d)
Additional information

1,5d
D
3d

2d

96 Fans and blowers for solid fuel heating systems · Edition 2022-06
Combined level of multiple same-level sound sources

15
[dB(A)]
[dB]
Adding 2 noise sources with the same level results in a level increase of approx. 3dB.
The noise characteristics of multiple identical fans can be determined in advance based

Increase in sound pressure / sound power level


on the noise values specified in the data sheet. This is shown in the diagram opposite.

10
9
Example:
8 A3G800 axial fans are on a condenser. According to the data sheet, the sound pressure
level of a fan is approximately 75dB(A). The level increase measured from the diagram is

5
9dB. Thus the overall sound level of the installation can be expected to be 84dB(A).

0
1 2 3 4 5 6 7 8 9 10 15 20 25

Number of sources of sound with identical level

3
[dB(A)]

Combined level of two different-level sound sources


[dB]

The acoustic performance of two different fans can be predetermined based on the
sound levels given in the data sheet. This is shown in the diagram opposite.
Increase in sound pressure / sound power level
2

Example:
There is an axial fan A3G800 with a sound pressure level of 75dB(A) at the operating
1,5

point and an axial fan A3G710 with 71dB(A) in a ventilation unit. The level difference is
4dB. The level increase can now be read in the diagram as approx. 1.5dB. This means that
1

the overall sound level of the unit can be expected to be 76.5dB(A).

Additional information
0

0 4 8 12 16 20 24
[dB]
Difference in level with two sources of sound [dB(A)]

Distance laws
0
[dB(A)]

Sound power level is independent of distance to the sound source. In contrast to this,
[dB]

sound pressure level decreases the further away the noise source is. The adjacent dia-
gram shows the decrease in level under far sound field conditions. Far sound field condi-
-10

tions apply whenever the distance between microphone and fan is big when compared
to fan diameter and wavelength to be considered. For more information on far sound
Decrease in sound pressure level

field, please consult the relevant literature on this complex topic. Per doubling of distan-
-20

ce, the level in the far sound field decreases by 6dB. In the near field of the fan, other
-26

correlations apply and the decrease in levels can be considerably smaller.


-30

The following example only applies to far sound field conditions and can vary strongly
depending on the installation effects: With an axial fan A3G300, a sound pressure level of
-40

65dB(A) was measured at a distance of 1m. According to the adjacent diagram, at a dis- 1 2 5 10 20 50 100

tance of 20m we would get a reduction by 26dB, i.e. a sound pressure level of 39dB(A). Distance [m]

Fans and blowers for solid fuel heating systems · Edition 2022-06 97
Fans and blowers for solid fuel heating systems

Contacts – Worldwide

98
Always find the right contact person!

www.ebmpapst.com/contact

Germany

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2
74673 Mulfingen
GERMANY
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com

ebm-papst St. Georgen GmbH & Co. KG


Hermann-Papst-Straße 1
78112 St. Georgen
GERMANY
Phone +49 7724 81-0
Fax +49 7724 81-1309
info2@de.ebmpapst.com

ebm-papst Landshut GmbH


Hofmark-Aich-Straße 25
84030 Landshut
Contacts

GERMANY
Phone +49 871 707-0
Fax +49 871 707-465
info3@de.ebmpapst.com

Fans and blowers for solid fuel heating systems · Edition 2022-06 99
www.ebmpapst.com 2022-06 Only as pdf

ebm-papst ebm-papst
Mulfingen GmbH & Co. KG Landshut GmbH

Bachmühle 2 Hofmark-Aich-Straße 25
74673 Mulfingen 84030 Landshut
Germany Germany
Phone +49 7938 81-0 Phone +49 871 707-0
Fax +49 7938 81-110 Fax +49 871 707-465
info1@de.ebmpapst.com info3@de.ebmpapst.com

You might also like