Airwellcare Sand Trap Louvers are specially quality extruded Aluminium profiles conforms
designed to prevent ingress of sand particles in to 6063-T5, ADC 1602 standard and DW 142
ventilation or air conditioning systems, where class C.
excessive intake air filtration is required for
HVAC System. Airwellcare Sand Trap Louvers are specially
designed to ensure required air flow to
the buildings / equipments, preventing the
Selection & Design ingression of dust, airborne sand etc. Each units
are designed and tested to withstand the most
Our Sand Trap Louvers are designed and arduous weather conditions over many years,
manufactured in compliance with international giving maximum protection by standard RAL
standards, to achieve the optimum results. Colour custom finishes.
These louvers are manufactured from high
Frame
2.0mm Thick high quality Extruded Aluminiun
Profile.
Blade
2.0mm Thick high quality Extruded Aluminiun
Profiles.
CONSTRUCTION DETAILS
CONSTRUCTION DETAILS
AHS SL 100 & 200
Exposed Type With Aluminium Filter & Damper
Flush Type
12 / 25
Filter
Damper
(W)X(H)
(W)X(H)
(W)X(H)
50
130 60 76
(W)
50
60
76
• Flush Type : Neck & Frame inside the wall • A - Complete construction with Aluminium
• Exposed : Neck (only) inside the wall • G - Complete construction with Galvanized Steel
• S - Complete construction with Stainless Steel
Note : Construction of model AHS SL 200 SP can be done with Flush or Exposed mounting, based on louver application.
ENGINEERING GUIDELINES
Model Selection
Select the below suitable model
AHS SL 100, 200 Or 300 (A) Aluminium (D) With Volume Damper
(G) Galvanized (C) Standard
Exposed Flush (F1) Alumminium Filter
(S) Stainless Steel (X) Others
(F2) Pre Filter
MATERIAL STORAGE,
MATERIAL STORAGE, OPERATION,
OPEATION AND MAINTENANCE
MAINTENANCE
The Louvers required to be handled Airwellcare Sand Trap Louvers are not
carefully during offloading as per the designed to be used in areas where they
upright arrow marks given on the unit in may be exposed to contaminants such as
the right position. Care should be taken water treatment or cleaning chemicals.
in lifting the product in all 4 corners and If the louvers are exposed to such
placing them on a raised floor level. Store contaminants, they should be cleaned
the product always in dry environment. immediately to reduce the detrimental
After receiving the Louvers, check for both impact of the chemicals.
obvious and hidden damages. If damage Cleaning of the louvers should be
is found due to manufacturing defect completed using a soft, clean cloth and
/ workmanship, record all necessary Soft Wash Gel cleaner. Surfaces should be
information with photographs and forward thoroughly rinsed with fresh water after
to Airwellcare. cleaning.
Maintenance In coastal or industrial environments
cleaning should be carried out more
Airwellcare Sand Trap Louvers are frequently paying particular attention to
designed for least maintenance. However, areas that are not normally washed by
it is recommended to have periodical rain.
inspection of blades for damage, wear and
tear etc. DO NOT use harsh cleaning fluids, strong
solvents or abrasive cleaning materials,
The louvers may, over time begin to collect as these will damage the surface finish on
dust and grime due to their location and the louvers.
exposure to varying weather conditions.
The louvers should be cleaned to refresh
their visual appearance at six monthly
intervals.
INSTALLATION DETAILS
Fig-1
Exposed Type
installation.
Fig-2
Flush Mounting
Type installation.