Reference Title Quantity Unit Cost


1 PRELIMINARIES AND GENERAL REQUIREMENTS
1.1 Non-Recurring Preliminary Costs (Mobilization)
Incurred at the commencement of the Works

1.1.1 Provision of all necessary offices and facilities for the Employer and the Engineer complete with all services, 1 Item
furniture, equipment and fixtures as specified.

1.1.2 Provision of all necessary offices, stores and facilities for Contractors' site staff in adequate manner as per 1 Item
the Works required.

1.1.3 Provision of sign boards as per ADCE design and requirement 1 Nos.
1.1.4 Provision of Sign board on top of the tower crane of dimensions (3.00 M X 1.22 M) as specified. 1 Item
1.1.5 Provision of site hoarding as specified with ADCE logo (Stickers 12 pieces). . 1 Item
1.1.6 Submittal of Performance Bond as per the Conditions of the Contract. 1 Item
1.1.7 Submittal of all insurances as per the Conditions of the Contract. 1 Item
1.1.8 Submittal of Programme for the Works and cash flow , whereby Contractor to submit Construction 1 Item
progarmmme (baseline) to the Engineer for approval

Allow for all obligations in accordance with the Contract, which are not mentioned above. The Contractor
1.1.9 shall detail and price below any other obligations indicating the relevant clause reference in the Contract Documents. 1 Item

“Fixed total amount to be paid by the awarded contractor related to third party verification & approval fees during the Design
Stage in case officially requested by the municipality (No OH&P allowable for this item): Fixed amount
1.1.10 1
- Soil investigation, structure third party NOC, Topographic survey (if requested by municipality), Gas NOC (No OH&P)
& TIS (if requested by DOT / municipality).
1.2 Recurring Preliminary Costs incurred during the Execution of the Works
1.2.1 Maintenance of all necessary offices and facilities for the Employer and the Engineer including all services, 1 Item
furniture, equipment and fixtures.

1.2.2 Maintenance of Contractor's site staff office, stores, and facilities. 1 Item
1.2.3 Provision of Contractors site management, administrative and supervisory staff in adequate manner as per 1 Item
the Works needs.

1.2.4 Provision of all required equipment and tools for the successful execution of the Works such as but not 1
limited to :

1.2.4.1 Light Equipment and tools 1 Item


1.2.4.2 Scaffolding 1 Item
1.2.4.3 Machinery, cranes, lifting plant, site transport. 1 Item
1.2.4.4 Plant required for specific trades. 1 Item
1.2.4.5 Maintenance of all above plant . 1 Item
1.2.5 Provision of all necessary site power and lighting for the Works. 1 Item
1.2.6 Provision of all necessary water for the Works. 1 Item
1.2.7 Provision of all necessary sanitation for the Works. 1 Item
Provision of safety and security requirements during progress of Works including watching, lighting, safety signs, fire fighting
1.2.8 requirements, first aid tools, safety shoes, protection helmets, safety belts and protection 1 Item
barriers/handrails, etc.
1.2.9 Provide, erect and maintain of all necessary scaffolds, access ways, ladders and the like for the safe and 1 Item
successful completion of the Works.

1.2.10 Provision of all required progress site reports, photos, and other documentation as per the Conditions of the 1 Item
Contract.

1.2.11 Provision of all required shop drawings and samples as specified and required by the Engineer. 1 Item
1.2.12 Provision of all required Quality Assurance and Quality Control as required by the Contract. 1 Item
1.2.13 Provision for all inspections and testing necessary for the acceptance of the Works in accordance with the 1 Item
Specifications and the Conditions of the Contract.

1.2.14 Maintaining site hoarding and sign boards. 1 Item


1.2.15 Cleaning up and removal of rubbish during the progress of the Works to the satisfaction of the Engineer. 1 Item
1.2.16 The programme shall be updated each month to reflect actual progress at site 1 Item
1.2.17 Provision for reservation parking during execution of the project and paying DOT related charges/fees 1 Item
Allow for all obligations in accordance with the Contract, which are not mentioned above. The Contractor shall detail and price
1.2.18 below any other obligations indicating the relevant clause reference in the Contract 1 Item
Documents.
1.3 Non-Recurring Preliminary Costs (Demobilization) incurred at the Completion of the Works
1.3.1 Demobilization and removal of all offices and facilities for the Employer and the Engineer including all 1 Item
services, furniture, equipment and fixtures.

1.3.2 Demobilization and removal of all offices, stores and facilities. 1 Item
1.3.3 Demobilization and removal of all equipment and tools. 1 Item
1.3.4 Provision of all required As Built drawings, Operation and Maintenance Manuals and guarantees. 1 Item
1.3.5 Clearing up and making good site establishment after completion of the Works and demobilization. This 1 Item
includes re-instating surrounding areas affected by the construction works.

Allow for all obligations in accordance with the Contract, which are not mentioned above. The Contractor shall detail and price
1.3.6 below any other obligations indicating the relevant clause reference in the Contract 1 Item
Documents.
1.3.7 Allow for the issuance of the Building Occupancy certificate or any other similar certificates required by the 1 Item
municipality
Allow for Provisional Sum (PS) of AED 3,500/- for Digital Property pictures by Professional Photograph as follows:-a. Property

1.3.8

2 SITE CONSTRUCTION
2.1 Demolition ( IF NEEDED )
The contractor shall allow for demolition of existing building. Removal of reusable items shall be done by others before starting
2.1.1 demolition work. The cost of this item shall include the cost of clearing the site from N/A item
all derbies arising from demolition work and removal of all existing foundations and obstructing piles.
The reusable items are property of the owner and he has the right to appoint a third party to remove it and main contrctor to
2.1.1.1 support and facility this activity .incase the owner elect to assign this task to main contrctor N/A item
then contrctor to remove and transport to the stores of the owner /tion decided by the owner
2.2 Soil investigation
1. Soil Report is for Guidance. The contractor shall perform geotechnical and geophysical investigations as per tender
documents.
2. Minimum no. of boreholes for soil test shall be 4 boreholes, 3 to a depth of 25 Meters below ground level and one to a depth
of 35 Meters with at least 2 meters in the rock strata.
3. It is the contractor’s responsibility to check the soil bearing capacity and its ability to support the structure and the
2.2.1 underground water tank without any settlement, if redesign in required to the structure and shoring system it is to be done by 1 item
the Contractor in coordination with the consultant and to get the necessary approvals from the related authorities then to be
executed at no extra cost or time.
4. Geophysical investigation to be done as per DMA regulations.
5. Materials Testing laboratories to be approved by DMA and registered with ADCE.

2.2.2 Geophysical investigation/Allow for performing geophysical investigations as per relevant authorities 1 item
requirements, rules and regulations.

2.2.3 Allow for any other site investigations needed by Tender Documents ( i.e. topographic surveys or any other 1 item
investigations required by Authorities).

2.3 Dewatering
Allow for design ,installing, maintaining and taking away upon completion, dewatering system as designed by a specialist firm
registered with ADCE and approved by the consultant engineer and local authorities, to lower the water level at least one
2.3.1 meter below bottom level of foundations and to keep all excavations free from water from whatever source. And to keep the N/A Item
site in a safe and secure working conditions all the time.
And should never stop until a written approval from the consultant engineer
2.4 Site Clearance
TMP‐DRM‐030
V3. 28th April 2022

Total Note

-
-
-
-
-
-

-
-

-
-
-
-
-
-
-
-

-
-
-

-
-
-
-

-
-
-
-

-
#VALUE!

#VALUE!

#VALUE!
2.4.1 The Contractor shall allow for the removal from site of all rubbish and debris and any existing foundations 1 Item -
prior to commencement of Works.

2.5 Existing Utilities


2.5.1 Allow for carefully relocating/shifting any existing utilities in work areas including hand excavating trial holes N/A Item #VALUE!
and all necessary earthwork supports.

2.5.2 Where utilities are to remain in place provide adequate means of support and protection during excavation N/A Item #VALUE!
and shoring operations, pilling works and construction stages.

2.6 Shoring ( IF NEEDED )


2.6.1 permanent shoring

Provision of sign boards as per ADCE design and requirement


2.6.1.1 N/A item #VALUE!

Allow for diaphragm wall system with min. wall thickness ÄÄ.Ä cm to be used as to be used as permanent shoring, as designed
by a specialist firm registered with ADCE and approved by the consultant engineer and local authorities, constructed using
sulfate resistant Portland cement or as recommended by soil investigation report and having a minimum 28-day compressive
2.6.1.2 strength of ÄÄ.Ä N/Sq.mm as per drawings and specification. Steel reinforcement shall be provided as per drawings and N/A item #VALUE!
specifications.

2.6.2 temporary shoring


Design and construct temporary shoring system consisting of steel I beams and timber panels. The Contractor should submit to
2.6.2.1 the Engineer's approval, design calculations and details. Design should be N/A m #VALUE!
based on soil investigation to be carried out.
2.6.2.2 Allow for earthwork support to the other excavation. N/A Item #VALUE!
2.6.2.3 Excavation 980 m3 -
2.6.2.4 Excavate to reduce levels to the required levels shown on drawings for any type of foundations ... N/A m3 #VALUE!
2.6.2.5 Trench excavation to receive pile caps and Ground beams. N/A m3 #VALUE!
2.6.2.6 Filling
Filling into excavation with approved imported filling clean and free from plants, foreign matter and debris material. To be laid in
2.6.2.7 layers not more than 25 cm in thickness with watering and compaction to min 95% on N/A m3 #VALUE!
MPT.
2.6.2.8 Filling oversite to make up levels. 775 m3 -
2.6.2.9 Disposal 205 m3 -
2.6.2.10 Remove surplus excavated material from site 1 Item -
2.6.2.11 Allow for making good exposed surfaces of concrete piles after excavation. 1 Item -
2.6.2.12 ANTI-TERMITE TREATMENT
2.6.2.13 Allow for anti-termite treatment to all below and above ground levels as specified. 1 Item -
2.7 Piling
Execute and install cast in situ reinforced Concrete Piles using temporary casing system as designed by a specialist firm
2.7.1 registered with ADCE and approved by the consultant engineer and local authorities, and per 1 Item -
drawings and specification.
2.7.2 The Contractor shall be responsible for the adequacy of the pile foundations installed to carry the working 1 Item -
loads safely and securely.

2.7.3 The Contractor shall be responsible to calculate the depth of piles based on the geotechnical report and to 1 Item -
the consultant’s engineer and Municipality Engineer's approval.

2.7.4 Mobilization and of plant and equipment to site. 1 Item -


2.7.5 Cast in situ piles including concrete grade ÄÄÄÄ.., boring through any type of soil, reinforcement cages and
removal of surplus material arising off site.

2.7.5.1 600 mm dia. pile, 1005. KN minimum capacity. 84 No -


2.7.5.2 600. mm dia. pile, 1005. KN minimum capacity. 23 No -
2.7.6 Pile Testing
2.7.6.1 Allow for load testing on piles in accordance with the specification.
2.7.6.2 Pile of 600mm dia. 84 No -
2.7.6.3 Pile of 600mm dia. 23 No -
2.7.6.4 Allow for integrity test for all piles 1 Item -
2.7.6.5 Allow for chipping off the extra concrete from piles to the required height retaining the steel reinforcement
using an approved method.

2.7.6.6 Piles, 600. mm dia. 84 No -


2.7.6.7 Piles, 600. mm dia. 23 No -
2.7.6.8 demobilization of plant and equipment from site on completion. 1 Item -
2.7.6.9 Any other tests needed to confirm the safety of piles as per specification and required by authorities . 1 No -
2.8 PAVING
2.8.1 Asphalt road system to municipality’s approvals, including required excavation, removal, relocating of any N/A m2 #VALUE!
obstructions backfilling with approved materials to the approvals of relevant authorities.

2.8.2 Supply and paint Precast curbstone as per municipality and roads dept. 23 m -
2.8.3 60mm thick colored interlocking tiles as per municipality and roads dept.. 50 m2 -
2.8.4 80mm thick colored interlocking tiles as per municipality and roads dept.. 205 m2 -
2.8.5 Road/traffic markings as specified and as per municipality and roads dept. 1 Item -
2.8.6 Sundries
2.8.6.1 Allow for any other miscellaneous work in connection with site construction. N/A Item #VALUE!
3 CONCRETE WORKS
3.1 FINISHING OF EXPOSED SURFACES OF SECANT PILES
3.1.1 Supply 500 mm. min. thick gunite concrete having a min. compressive strength of 40N/mm2, sprayed at N/A m2 #VALUE!
pressure as specified, including ÄÄ.. welded steel mesh.

3.2 SUBSTRUCTURE
3.2.1 Concrete work in accordance with specification
3.2.1.1 Plain Concrete
3.2.1.1.1 Plain sulphate resisting cement concrete grade 20.. N
3.2.1.1.1.1 50 mm thick, blinding concrete 8 m3 -
3.2.1.1.1.2 100... mm thick, blinding concrete 75 m3 -
3.2.1.2 Reinforced Concrete
3.2.1.2.1 Reinforced insitu ordinary Portland cement concrete grade 40. N, including Reinforcement and shuttering,
3.2.1.2.1.1 Raft ÄÄÄÄÄ. mm. thick. N/A m3 #VALUE!
3.2.1.2.1.2 Pile caps 62 m3 -
3.2.1.2.1.3 Tie beams for pile caps / Ground beams 85 m3 -
3.2.1.2.1.4 Water tank base slab, 100. mm thick using waterproof additives in concrete mix. 2 m3 -
3.2.1.2.1.5 Basement walls, ÄÄÄÄ...mm thick. N/A m3 #VALUE!
3.2.1.2.1.6 Ramp, ÄÄÄÄ. mm thick N/A m3 #VALUE!
3.2.1.2.1.7 Slab on grade, AAA.. mm thick N/A m3 #VALUE!
3.2.1.2.1.8 Ditto, ÄÄÄÄÄÄ.. mm thick N/A m3 #VALUE!
3.2.1.2.1.9 Thickening of grade slab N/A m3 #VALUE!
3.2.1.2.1.10 Walls of water tank, ÄÄ.. mm. thick using waterproof additives in concrete mix. N/A m3 #VALUE!
3.2.1.2.1.11 Walls, ÄÄÄÄÄÄ.. mm thick N/A m3 #VALUE!
3.2.1.2.1.12 Ditto, ÄÄÄÄÄÄ.. mm thick N/A m3 #VALUE!
3.2.1.2.1.13 Ditto, ÄÄÄÄÄÄ.. mm thick N/A m3 #VALUE!
3.2.1.2.1.14 Columns 5 m3 -
3.2.1.2.1.15 Staircases. N/A m3 #VALUE!
3.2.1.2.1.16 Beams. N/A m3 #VALUE!
3.2.1.2.1.17 Upstands. N/A m3 #VALUE!
3.2.1.2.1.18 Suspended slabs, 200.mm thick. 140 m3 -
3.2.1.2.1.19 Suspended slabs, AAA.mm thick. N/A m3 #VALUE!
3.2.1.2.1.20 Injection System ( IF NEEDED )
3.2.1.2.1.20.1 Allow for re-injectionable system for basement walls and all underground construction joints in contact with N/A item #VALUE!
soil. The Contractor should carry out the injection process when and wherever instructed.

3.2.1.3 Substructure Waterproofing


3.2.1.3.1 Supply and lay polyethylene sheet, 1000.. Gauge. 1100 m2 -
3.2.1.3.2 Pile head treatment as specified
3.2.1.3.2.1 To pile, 600.. mm dia. 84 No -
3.2.1.3.2.2 To pile, 600.. mm dia. 23 No -
3.2.1.3.3 Supply and apply 3 layers of Rubberizeed prime system, all in accordance with drawings and specification
3.2.1.3.3.1 To horizontal concrete surfaces 165 m2 -
3.2.1.3.3.2 To vertical concrete surfaces 890 m2 -
3.2.1.3.4 Supply and apply one layer of waterproofing membrane ÄÄÄ. mm. thick, including primer, all in accordance
with drawings and the specification

3.2.1.3.4.1 To horizontal concrete surfaces 180 m2 -


3.2.1.3.4.2 To vertical concrete surfaces 220 m2 -
3.2.1.4 Protection screed as specified
3.2.1.4.1 50. mm thick to horizontal surfaces 68 m2 -
3.2.1.5 Protection Board as specified
3.2.1.5.1 Fixed vertically against exposed waterproofing membrane N/A m #VALUE!
3.2.1.5.2 Heavy duty PVC water stops for all construction joints. N/A m #VALUE!
Allow for periodical site visit attendance of QA / QC Waterproofing manufacturer specialist for the
3.2.1.5.3 supervision of the Certified Applicators for the Waterproofing Works in substructure, Roofing & swimming pools. 1 item -

Allow for the review of the Engineering submittals (Materials, Method statements & Shop Drawings) by the QA / QC
Waterproofing manufacturer for the Waterproofing Works in substructure, Roofing & swimming pools.
3.2.1.5.4 1 Item -

3.2.1.6 Water Tank Lining


Supply and fix in place ÄÄ.. Lining for all inner surfaces of water tank including the water tank ceiling and neck as specified. The
3.2.1.6.1 Contractor should furnish certificate supporting that the materials used are suitable N/A m2 #VALUE!
for potable water usage.
3.2.1.6.2 ÄÄÄÄ. ladder for water tank. N/A No. #VALUE!
3.3 SUPERSTRUCTURE
3.3.1 Concrete work in accordance with specification
3.3.1.1 Reinforced insitu ordinary Portland cement concrete grade 40. N, including Reinforcement and shuttering,
3.3.1.1.1 Columns 97 m3 -
3.3.1.1.2 Walls, ÄÄÄ. mm thick N/A m3 #VALUE!
3.3.1.1.3 Ditto, ÄÄÄÄ. mm thick N/A m3 #VALUE!
3.3.1.1.4 Ditto, ÄÄÄÄ.. mm thick N/A m3 #VALUE!
3.3.1.1.5 Ditto, but curved. N/A m3 #VALUE!
3.3.1.1.6 Beams. 60 m3 -
3.3.1.1.7 Ditto, but curved. N/A m3 #VALUE!
3.3.1.1.8 Parapets. 26 m3 -
3.3.1.1.9 Ditto, but curved. N/A m3 #VALUE!
3.3.1.1.10 Upstands. N/A m3 #VALUE!
3.3.1.1.11 Ditto, but curved. N/A m3 #VALUE!
3.3.1.1.12 Suspended slab, 280. mm thick 86 m3 -
3.3.1.1.13 Ditto, 260... mm thick 339 m3 -
Ditto, 240... mm thick 48
3.3.1.1.14 Ditto, 200... mm thick 14 m3 -
3.3.1.1.15 Staircases m3 #VALUE!
3.3.2 Concrete work in accordance with specification
3.3.2.1 Reinforced insitu ordinary Portland cement concrete grade ÄÄ. N, including Reinforcement and shuttering,
3.3.2.1.1 Columns N/A m3 #VALUE!
3.3.2.1.2 Walls of swimming pool, using waterproof additives in concrete mix. N/A m3 #VALUE!
3.3.2.1.3 Walls, ÄÄÄ... mm thick N/A m3 #VALUE!
3.3.2.1.4 Ditto, ÄÄÄÄ. mm thick N/A m3 #VALUE!
3.3.2.1.5 Ditto, but curved. N/A m3 #VALUE!
3.3.2.1.6 Beams. N/A m3 #VALUE!
3.3.2.1.7 Ditto, but curved. N/A m3 #VALUE!
3.3.2.1.8 Parapets. N/A m3 #VALUE!
3.3.2.1.9 Ditto, but curved. N/A m3 #VALUE!
3.3.2.1.10 Upstands. N/A m3 #VALUE!
3.3.2.1.11 Ditto, but curved. N/A m3 #VALUE!
3.3.2.1.12 Staircases
3.3.2.1.13 Slabs of swimming pool, using waterproof additives in concrete mix. N/A m3 #VALUE!
3.3.2.1.14 Suspended slabs,ÄÄÄ...mm thick. N/A m3 #VALUE!
3.3.2.1.15 Ditto, ÄÄÄ... mm thick N/A m3 #VALUE!
3.3.2.1.16 Sundries
3.3.2.1.16.1 Foundations for A/C machines, pumps, water tanks, etc. N/A item #VALUE!
3.3.2.1.16.2 Supply and fix ÄÄ.. cm high heavy duty water stop for swimming pool. N/A item #VALUE!
4 MASONRY
4.1 Precast Solid concrete blocks, as specified. The contrcator shall abide with Estidama requiremnst and
specifications

4.1.1 200. mm thick, solid blockwork 537 m2 -


4.1.2 ÄÄÄÄÄÄ. mm thick, ditto N/A m2 #VALUE!
4.2 Precast Hollow concrete blocks as specified.The contrcator shall abide with Estidama requiremnst and
specifications

4.2.1 250.. mm thick, block walls 120 m2 -


4.2.2 200.. mm thick, ditto 630 m2 -
4.2.3 100.. mm thick, ditto 1200 m2 -
4.2.4 Ditto, curved m2 -
4.3 Autoclaved aerated light weight thermal concrete blocks as specified.The contrcator shall abide with
Estidama requiremnst and specifications

4.3.1 ÄÄÄÄ.. mm thick, block walls N/A m2 #VALUE!


4.3.2 ÄÄÄÄ.. mm thick, ditto N/A m2 #VALUE!
4.3.3 ÄÄÄÄ.. mm thick, ditto N/A m2 #VALUE!
4.3.4 Ditto, curved N/A m2 #VALUE!
4.4 Insulated thermo blocks.
4.4.1 300.. mm thick, block walls 155 m2 -
4.4.2 250.. mm thick, ditto 110 m2 -
4.4.3 200.. mm thick, ditto 1040 m2 -
4.4.4 Glass blocks having size of ÄÄ X Ä.. X Ä.. mm, including powder coated aluminium frame. N/A m2 #VALUE!
4.5 Reinforced concrete lintels, including shuttering and reinforcement
4.5.1 lintel, 100 x 200 mm 2 m -
4.5.2 Ditto, 150 x 200 mm N/A m #VALUE!
4.5.3 Ditto, 200 x 200 mm 4 m -
5 METALWORKS
5.1 Non-Structural Metalwork
5.1.1 Stainless steel cladding for columns
5.1.1.1 1.5 mm thick stainless steel cladding mirror finish, including S.S.U. channel, aluminium tube and aluminium N/A m2 #VALUE!
angle.

5.1.2 Balustrades and Handrails


5.1.2.1 Ä... mm high balustrade comprising Ä... mm diameter galvanised pipe epoxy painted handrail. N/A m #VALUE!
5.1.2.2 Powder coated Aluminum handrail for staircases, fixed to steps complete as per drawings. 138 m -
5.1.2.3 Powder coated Aluminum handrail for staircases, wall mounted complete as per drawings. N/A m #VALUE!
5.1.2.4 Powder coated Aluminum handrail behind windows. N/A m #VALUE!
5.1.2.5 Stainless steel handrail at elevations, N/A m #VALUE!
5.1.3 Ladders
5.1.3.1 5000. mm high, 65 mm wide powder coated aluminium cat ladder 6 No -
5.1.3.2 ÄÄ. mm high, ÄÄ. mm wide, ditto N/A No #VALUE!
5.1.3.3 Stainless steel ladder complete as per drawings. N/A No #VALUE!
5.1.3.4 Design, fabricate and fix in place galvanized steel stair located in pump room, with ÄÄÄ.cm dia., epoxy N/A item #VALUE!
coated galvanized iron pipes as handrail.

5.2 Structural Metalwork


5.2.1 Galvanized, epoxy painted steel frame with columns, for supporting the windows cradle system, Columns N/A item #VALUE!
shall be bolted, using grade 316 S.S bolts, to reinforced concrete pedestals projectded from roof slab

5.2.2 Design, fabricate and fix in place steel canopy at ROOF Floor. 1 item -
5.2.3 Design, fabricate and erect powder coated aluminium Pergola N/A item #VALUE!
5.2.4 Sundries N/A
5.2.4.1 Fabricate and fix in place, aluminium decorative mast at elevation. N/A item #VALUE!
5.2.4.2 Supply and fix in place powder coated aluminium air foil blades located at Ground floor. N/A item #VALUE!
5.2.4.3 Fabricate and install in position 200cm high, fence for Gaz Tank at roof, complete with access controlled N/A m #VALUE!
door as per details.

5.2.4.4 Supply and fix in position, epoxy coated, galvanized iron platforms inside the shafts, as per drawings and N/A item #VALUE!
specifications.

5.2.4.5 Provide and fix in the main entrance lobby, a 60x40x.02 cm stainless steel signage plate to declare the N/A No #VALUE!
Building Name, Building No. and ADCP the property manager.

6 WOOD AND PLASTICS


6.1 KITCHEN CABINETS
6.1.1 Fabricate, supply and install approved ready made wall and base kitchen cabinets, complete with ÄÄÄÄ...
worktop with backsplash, stainless steel sinks, mixers, ironmongery and drawers, as specified.

6.1.2 Wall cabinets. 54 m -


6.1.3 Base cabinets. 54 m -
6.2 BUILT-IN WARDROBES
6.2.1 Supply and fix in place factory made wardrobes including ironmongeries, as specified.
6.2.2 Type ( W 1 ). 21 m -
6.2.3 Type ( W 2 ). 4.95 m -
6.2.4 Type ( W 3 ). 10.2 m -
6.2.5 Type ( W 4 ). 14.6 m -
6.2.6 Type ( W 5 ). 7.2 m -
6.2.7 Type ( W 6 ). 17.6 m -
6.2.8 Type ( W 7 ). 8.7 m -
6.3 COUNTERS
6.3.1 Fabricate and fix counter at main entrance as per drawings. N/A item #VALUE!
7 THERMAL AND MOISTURE PROTECTION
7.1 ROOFING SYSTEM
7.1.1 Combo roof system ( Roof care) According to drawings ) 760 m2 -
7.1.2 ÄÄ.. mm thick min. ÄÄÄÄÄ. screed laid to falls. N/A m2 #VALUE!
7.1.3 ÄÄÄ... mm thick waterproofing membrane on and including 2 coats of primer N/A m2 #VALUE!
7.1.4 Separation layer, ÄÄ.. g/sq.m minimum density N/A m2 #VALUE!
7.1.5 Ä... mm thick insulation board, ÄÄ. Kg/m3 minimum density N/A m2 #VALUE!
7.1.6 Separation layer, ÄÄ.. g/sq.m minimum density N/A m2 #VALUE!
7.1.7 ÄÄÄ... gauge polyethylene sheet. N/A m2 #VALUE!
7.1.7 600. x 600.. mm, Porcelin. floor tiles on Roof 330 m2 -
7.1.8 Skirting
7.1.8.1 Combo roof system ( Roof care) According to drawings ) 452 m -
7.1.8.2 50 x 50 mm cement sand screed angle fillet, to base of parapets and upstands N/A m #VALUE!
7.1.8.3 Two coats of bitumen primer. N/A m #VALUE!
7.1.8.4 ÄÄÄ. mm wide corner reinforcing strip overlapping the horizontal laid membrane. N/A m #VALUE!
7.1.8.5 600x100.cm porcelin. Tiles 180 m -
7.2 WET AREAS
7.2.1 100. mm thick . applied waterproofing membrane on and including bitumen primer. 121 m2 -
7.2.2 50 mm thick sand cement protection screed 121 m2 -
7.2.3 THERMAL & MOISTURE INSULATION OF SURFACES BEHIND EXTERNAL CLADDING
7.2.3.1 Supply and fix on concrete and/or block work behind external cladding, ÄÄ.Ä mm thick rockwool having N/A m2 #VALUE!
aluminum foil on its surface facing outer face.

7.2.3.2 Supply and fix on concrete and/or block work behind external cladding, vapor barrier paint. 2400 m2 -
7.2.3.3 SUNDRIES:
7.2.3.3.1 waterproofing system for swimming pool, as detailed N/A item #VALUE!
8 DOORS AND WINDOWS
8.1 WOODEN DOORS
8.1.1 Doors shall be made as per drawings and specifications, provided with all necessary approved accessories
and ironmongery.

8.1.2 Subframes: 18mm thick marine plywood.


8.1.3 Frame and subframe shall suit the walls thicknesses.
8.1.4 I - SOLID DECORATIVE DOORS
8.1.4.1 Door Leaf : Solid Africa teak wood with decoration
8.1.4.2 Frames and architrave fabricated using meranti Wood.
8.1.4.3 Doors finish:As per Specification..
8.1.4.4 Type-D1, size 1500X3000 mm 6 No -
8.1.4.5 Type-D2, size 1000*2200 - mm 6 No -
8.1.4.6 Type-D3, size ------- X mm N/A No #VALUE!
8.1.5 II - FLUSH DOORS
8.1.5.1 Door Leaf : Flush Door Meranti Door.
8.1.5.2 Frames and architrave fabricated using meranti Wood.
8.1.5.3 Doors finish: As per Specification..
8.1.5.4 Type-D3, size 600*2200 mm 6 No -
8.1.5.5 Type-D4, size 5000*2200 mm 24 No -
8.1.5.6 Type-D5, size 900*2200 mm 6 No -
8.1.5.7 Type-D6, size 800*2200 mm 42 No -
8.1.6 III - FLUSH DECORATIVE DOORS
8.1.6.1 Door Leaf : 6mm MR MDF ÄÄ.. veneered on both sides and 4 edges.
8.1.6.2 Frames and architrave fabricated using ÄÄ. Wood.
8.1.6.3 Doors finish: ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ..
8.1.6.4 Type-D8, size ------- X ------- mm using core or equal N/A No #VALUE!
8.1.6.5 Type-D9, size ------- X ------- mm using core or equal N/A No #VALUE!
8.1.6.6 Type-D10, size ------- X mm using fire rated board core N/A No #VALUE!
8.1.6.7 Type-D11, size ------- X mm using fire rated board core N/A No #VALUE!
8.1.7 IV - Arches:
8.1.7.1 Frames and architrave fabricated using ÄÄ. Wood.
8.1.7.2 Subframes: 18mm thick marine plywood.
8.1.7.3 Frame and subframe shall suit the walls thicknesses.
8.1.7.4 Finish : ÄÄÄÄÄÄÄÄÄÄÄÄ
8.1.7.5 Type ( Ar 1 ). N/A Nos. #VALUE!
8.1.7.6 Type ( Ar 2 ). N/A Nos. #VALUE!
8.1.7.7 Type ( Ar 3). N/A Nos. #VALUE!
8.1.8 CUBICLES
8.1.8.1 Ä... mm high toilet cubicles doors comprising ÄÄ. mm thick solid laminate panels and other necessary N/A m #VALUE!
accessories

8.2 ALUMINUM DOORS


8.2.1 I - Aluminium framed doors with powder coated aluminium sandwich panel including ironmongery as
specified.

8.2.1.1 Type-AL1, size 1000*2200 mm 1 No -


8.2.1.2 Type-AL2, size 1000*2200 mm 6 No -
8.2.1.3 Type-AL3, size AAA mm N/A No #VALUE!
8.2.1.4 Type-AL4, size AAA mm N/A No #VALUE!
8.2.2 II - Aluminium framed doors with powder coated aluminium louver including ironmongery as specified.
8.2.2.1 Type-AL5, size AAA mm N/A No #VALUE!
8.2.2.2 Type-AL6, size AAA mm N/A No #VALUE!
8.2.2.3 Type-AL7, size AAA mm N/A No #VALUE!
8.2.2.4 Type-AL8, size AAA mm N/A No #VALUE!
8.2.3 III - Powder coated aluminum hinged doors with double glass including ironmongery as specified.
8.2.3.1 Type-AL5, size ----- X mm, with ÄÄmm th. Fully tempered clear glass. N/A No #VALUE!
8.2.3.2 Type-AL6, size ----- X mm, with ÄÄmm th. Fully tempered clear glass. N/A No #VALUE!
8.3 STEEL DOORS:
8.3.1 Galvanized steel doors as per drawings and specifications, provided with all necessary approved
accessories and ironmongery.

8.3.2 Finish: Epoxy painted as specified.


8.3.3 Steel flush door, type ( ST 1 ) size of ------ X ----- cm. seamless, ÄÄ... hours fire rated. N/A Nos. #VALUE!
8.3.4 Steel flush door, type ( ST 1 ) size of ------ X ----- cm. seamless, ÄÄ... hours fire rated. N/A Nos. #VALUE!
8.4 ALUMINUM WINDOWS
8.4.1 Double glazed powder coated Aluminum windows including ironmongery as specified.
8.4.1.1 Type 1, size 3000*3400 mm 6 No -
8.4.1.2 Type 2, size 600*800 mm 6 No -
8.4.1.3 Type 3, size 800*2500. mm 6 No -
8.4.1.4 Type 4, size 600*18000. mm 1 No -
8.4.1.5 Type 5, size 2000*1800 . mm 23 No -
8.4.1.6 Type 6, size 5000*3100 mm 6 No -
8.4.1.7 Type 7, size 3000*3000. mm 6 No -
8.4.1.8 Type 8, size 1800*2900. mm 6 No -
8.4.2 Frameless Glass
8.4.2.1 Frameless clear tempered glass ÄÄ. mm thick including operating devices for sliding doors complete with all
accessories and ironmongery as specified.

8.4.2.1.1 Type FL1, size ÄÄ X ÄÄ. mm N/A No #VALUE!


8.4.2.1.2 Type FL2, size ÄÄ X ÄÄ. mm N/A No #VALUE!
8.4.2.1.3 Type FL3, size ÄÄ X ÄÄ. mm N/A No #VALUE!
8.4.2.1.4 Type FL4, overall size Ä.. X Ä.mm including 2 No. Ä. X Ä..mm sliding glass doors N/A No #VALUE!
8.4.2.1.5 Type FL5, overall size Ä.. X Ä.mm including 2 No. Ä. X Ä..mm sliding glass doors N/A No #VALUE!
8.4.3 Glazed Curtain Wall
8.4.3.1 Structural double glazed powder coated aluminum curtain wall including ironmongery as specified.
8.4.3.1.1 Type ( CU1 ), size of 2000*3000..mm. 6 Nos. -
8.4.3.1.2 Type ( CU2 ), size of 10300*2900..mm. 2 No. -
8.4.3.1.3 Type ( CU3 ), size of ÄÄ X ÄÄ..cm. N/A No. #VALUE!
8.4.3.1.4 Sundries
8.4.3.1.4.1 Supply and fix in position access doors for maintenance, complete. N/A m2 #VALUE!
8.4.3.1.4.2 Ä.. X Ä. Cm. aluminum access door for water tank fabricated using 18mm th. marine plywood plus Ä. mm N/A No. #VALUE!
thick aluminum sheets both sides, complete.
9 FINISHES
9.1 I- INTERNAL FINISHES
9.1.1 Flooring
9.1.1.1 Granite / Marble Floor Tiles fixing and grouting including background as specified.
9.1.1.1.1 Granite / Marble tiles. 30 m2 -
9.1.1.1.2 Ditto, . 38 m2 -
9.1.1.1.3 Granite / Marble treads for staircase,non-slip strips as specified. 48 m -
9.1.1.1.4 Granite / Marble risers for staircase. 317 m -
9.1.1.2 Ceramic Floor Tiles fixing and grouting including background as specified.
9.1.1.2.1 600x600. mm ceramic tiles 1200 m2 -
9.1.1.2.2 600*600 mm heavy duty ceramic tiles N/A m2 #VALUE!
9.1.1.2.3 600*600 mm non slip, ditto 360 m2 -
9.1.1.3 Graniti ceramic Floor Tiles fixing and grouting including background as specified.
9.1.1.3.1 ÄÄ.. x ÄÄÄ x ÄÄ.. mm graniti tiles N/A m2 #VALUE!
9.1.1.4 Mosaic Floor Tiles fixing and grouting including background as specified.
9.1.1.4.1 ÄÄ.. x ÄÄÄ x ÄÄ... mm mosaic tiles N/A m2 #VALUE!
9.1.1.4.2 ÄÄ mm thick polished precast mosaic for stairs tread and riser in one piece. N/A m #VALUE!
9.1.1.5 Screed Flooring painted as specified.
9.1.1.5.1 Epoxy screed plus Vehicular Traffic bearing deck coating system for parking areas including floor marking N/A m2 #VALUE!
and floor traffic signs.

9.1.1.5.2 ÄÄ mm thick screed painted with ÄÄ. coats of epoxy resin based floor coating. N/A m2 #VALUE!
9.1.1.6 DOOR MAT
9.1.1.6.1 Ä.. X ÄÄmm door mat, including aluminum gate ribs supporting channel, complete. N/A No. #VALUE!
9.1.1.7 SKIRTING
9.1.1.7.1 600*100 mm ceramic skirting. 900 m -
9.1.1.7.2 ÄÄ mm high, ÄÄmm thick ÄÄ. Granite / marble with curved edge for staircase. N/A m #VALUE!
9.1.1.7.3 2 coats of epoxy resin based coating, ÄÄ mm high. N/A m #VALUE!
9.1.1.8 THRESHOLD
9.1.1.8.1 . Marble threshold, rounded edges, at door frames, 65 m -
9.1.1.8.2 ÄÄÄ.. Marble sills, ÄÄ. mm thick ÄÄÄmm width rounded edge. N/A m #VALUE!
9.1.2 WALL FINISHES
9.1.2.1 Cement/sand plaster finish to internal surfaces as specified
9.1.2.1.1 Walls paint finish 4500 m2 -
9.1.2.1.2 Ditto, ceramic finish 1500 m2 -
9.1.2.2 Wall tiling, fixing and grouting on and including background as specificied
9.1.2.2.1 Ä.. x ÄÄ x ÄÄ.. mm Granite / Marble tiles N/A m2 #VALUE!
9.1.2.2.2 Ditto, Ä... x ÄÄ.. x ÄÄÄ.. mm N/A m2 #VALUE!
9.1.2.2.3 300x600. mm. Ceramic tiles 1350 m2 -
9.1.2.2.4 Ditto, Ä... x ÄÄ.. x ÄÄ.. mm N/A m2 #VALUE!
9.1.2.2.5 Ä.. x Ä.. x ÄÄ. mm. Graniti ceramic tiles N/A m2 #VALUE!
9.1.2.2.6 Ditto, Ä... x ÄÄ..x ÄÄ. mm N/A m2 #VALUE!
9.1.2.2.7 Painting and Decoration
9.1.2.2.7.1 Washable emulsion paint. 4200 m2 -
9.1.2.2.7.2 Ditto, but curved N/A m2 #VALUE!
9.1.2.2.7.3 Oil paint system. N/A m2 #VALUE!
9.1.2.2.7.4 Ditto, but curved N/A m2 #VALUE!
9.1.2.2.7.5 ÄÄ... Epoxy, ÄÄÄÄ... finish paint. N/A m2 #VALUE!
9.1.2.2.7.6 Ditto, but curved N/A m2 #VALUE!
9.1.2.2.7.7 Decorative paint ÄÄÄÄÄÄ.Ä. N/A m2 #VALUE!
9.1.2.2.7.8 Ditto, but curved N/A m2 #VALUE!
9.1.3 Ceiling Finishes
9.1.3.1 Cement/sand plaster finish to ceiling
9.1.3.1.1 Concrete soffit 1200 m2 -
9.1.3.1.2 Ditto, but for sloping soffits N/A m2 #VALUE!
9.1.3.2 Painting and Decoration
9.1.3.2.1 Washable emulsion paint. N/A m2 #VALUE!
9.1.3.2.2 Ditto, slopping soffit N/A m2 #VALUE!
9.1.3.2.3 Oil paint system. N/A m2 #VALUE!
9.1.3.2.4 Ditto, slopping soffit N/A m2 #VALUE!
9.1.3.2.5 ÄÄ... Epoxy, ÄÄÄÄ... finish paint. N/A m2 #VALUE!
9.1.3.2.6 Ditto, slopping soffit N/A m2 #VALUE!
9.1.3.2.7 Decorative paint ÄÄÄÄÄÄ.Ä. N/A m2 #VALUE!
9.1.4 False ceilings
9.1.4.1 C1(plaster+ paint) 402 m2 -
9.1.4.2 C2 (Gypsum board+ paint) 780 m2 -
9.1.4.3 C3 ( Moisture resistant gypsum + paint ) 150 m2 -
9.1.4.4 C4(Aluminum Ceiling) 150 m2 -
9.1.4.5 Bulk head gypsum board. 369 m -
9.1.4.6 Bulk head gypsum moisture resistant. 168 m -
9.2 II- EXTERNAL FINISHES
9.2.1 Floors
9.2.1.1 Granite tiles. 32 m -
9.2.1.2 30 mm thick curved edge Granite for tread. N/A m #VALUE!
9.2.1.3 20 mm thick Granite for riser. N/A m #VALUE!
9.2.2 Walls
9.2.2.1 Cement and sand plaster as specified For Parapet
9.2.2.1.1 Walls 610 m2 -
9.2.2.1.2 Ä. X Ä. X Ä. mm ÄÄÄ. granite / marble tiles, for ÄÄÄÄÄ.. fixed using dry fix method, N/A m2 #VALUE!
9.2.2.1.3 Like stone paint ÄÄ. mm minimum thick, N/A m2 #VALUE!
9.2.2.1.4 Acrylic system paint. 610 m2 -
9.2.2.1.5 ARTIFICIAL STONE 1 1860 m2 -
9.2.2.1.6 ARTIFICIAL STONE 2 400 m2 -
9.2.2.1.7 TRAVANTINE STONE 140 m2 -
9.3 III- SUNDRIES
9.3.1 CAR PARKING
9.3.1.1 Columns protection. N/A m #VALUE!
9.3.1.2 Walls protection. N/A m #VALUE!
9.3.1.3 Ready made rubber speed humps. N/A m #VALUE!
9.3.1.4 ÄÄÄÄÄÄÄÄÄÄÄ.. wheel stoppersÄ. mm. N/A m #VALUE!
9.3.1.5 Concaved traffic mirrors ÄÄ. X ÄÄ. mm N/A Nos. #VALUE!
10 PLUMBING AND DRAINAGE
10.1 WATER SUPPLY SYSTEM
10.1.1 Supply, install, testing and commissioning of all cold water piping complete with support and all necessary
fittings, valves and accessories; all in accordance with drawings and specification

Complete internal concealed piping in Poly Propylene Random pipes for cold water supply with all necessary fittings, supports
10.1.1.1 and accessories. Rates shall include all flushing, cleaning, testing and
commissioning. For Internal Diameter:
10.1.1.1.1 25Ø 1 L.S -
10.1.1.1.2 32Ø 1 L.S -
10.1.1.1.3 40Ø 1 L.S -
10.1.1.1.4 50Ø 1 L.S -
10.1.1.1.5 65Ø 1 L.S -
10.1.1.1.6 75Ø 1 L.S -
10.1.1.1.7 100Ø 1 L.S -
10.1.1.1.8 125Ø 1 L.S -
10.1.1.1.9 150Ø 1 L.S -
Complete water supply filling lines, transfer pipes, overflow pipes, boosted water riser and gravity riser piping with UPVC
pressure pipes, suitable for system working pressure, with all necessary fittings, supports and accessories as specified and
10.1.1.2
shown on drawings. Rates shall include all flushing, cleaning, testing and
commissioning. For Internal Diameter:
10.1.1.2.1 25Ø 1 L.S -
10.1.1.2.2 32Ø 1 L.S -
10.1.1.2.3 40Ø 1 L.S -
10.1.1.2.4 50Ø 1 L.S -
10.1.1.2.5 65Ø 1 L.S -
10.1.1.2.6 75Ø 1 L.S -
10.1.1.2.7 100Ø 1 L.S -
10.1.1.2.8 125Ø 1 L.S -
10.1.1.2.9 150Ø 1 L.S -
10.1.1.2.10 All exposed Pipes on roof, plant rooms and basement shall be insulated and protected with cladding as 1 L.S -
specified

10.1.1.3 PEX pipes complete with sleeves for all cold water droppers from above false ceiling to the fixtures 1 L.S -
Supply, install, testing and commissioning of all hot water piping Stabilized PPR, PN-20 complete with insulation, supports and
all necessary fittings, valves and accessories; all in accordance with drawings and specification. Rates shall include all flushing,
10.1.2
cleaning, testing and commissioning. For Internal Diameter:

10.1.2.1 25Ø 1 L.S -


10.1.2.2 32Ø 1 L.S -
10.1.2.3 40Ø 1 L.S -
10.1.2.4 50Ø 1 L.S -
10.1.2.5 65Ø 1 L.S -
10.1.2.6 75Ø 1 L.S -
10.1.2.7 100Ø 1 L.S -
10.1.2.8 125Ø 1 L.S -
10.1.2.9 150Ø 1 L.S -
10.1.2.10 PEX pipes complete with sleeves for all hot water droppers from above false ceiling to the fixtures 1 L.S -
Complete external piping connections, from ADDC Main to underground water tank, including all Meters,
10.1.3 cabinets, accessories and valves, as specified, and required by ADDC and to the approval of the Engineer. Rates shall include 1 item -
all flushing, cleaning, testing and commissioning as specified.
10.1.4 Each bathroom, toilet and kitchen shall have Chromium plated, Concealed main isolating valve for ease of 1 item -
maintenance.

10.1.5 Each Sanitary ware shall have Chromium plated, isolating valve for ease of maintenance. Valves shall be 1 item -
same as fitting's mixers type.

10.1.6 Water Tanks:


Supply, installation, testing and commissioning of water tanks, sizes and locations as shown on drawings complete with a
partition , valves, fittings, ladders, inspection covers, float valves, vent lines with all necessary supports and pads as per project
10.1.6.1
specifications and manufacture recommendations. Water tanks
shall be interconnected with pipes and necessary valves, fittings and specials, etc. complete.
10.1.6.2 GRP water tank {SIZE 2(L)X1(W)X2(H) } 12 Nos. -
10.1.7 Pumps:
Supply, install test and commission electrical water transfer pump set as specified, automatically operated, as shown and
10.1.7.1 indicated on the approved drawings, complete with its related valves, accessories, wiring and 6 Set -
control panel.
10.1.7.2 Supply, install test and commission Booster pump set ;complete with all related valves, accessories, fittings 6 Set -
wiring and control panel

10.1.8 Filtration System:


Supply, install test and commission of central filtration system including sand filters/ multimedia filter complete with filtration
10.1.8.1 pump set and all associated valves, accessories, fittings, wiring and control panel as shown on the drawings and as per
specifications.
10.1.8.2 Ultra Violet sterilizer with valves and aluminum protection cover.
10.1.8.3 Copper-Silver Ionizer with valves and aluminum protection cover.
10.1.9 Water Meters:
10.1.9.1 Supply and install the following water meters with plus reader, electric wires, all necessary pipes, fitting, 6 Nos. -
valves, etc. as specified and required by ADDC.

10.1.9.2 Consumers' water meter aluminum cabinet 6 Nos. -


10.1.9.3 Allow for installation of main incomer water meter and all associated valves,chamber,cover, cabinet, N/A L.S #VALUE!
accessories, controls and as required by ADDC

Allow for installation of water meters and all associated cabinet, accessories, controls and for swimming pools, external water
10.1.9.4 features, irrigation..etc. as required by by Estidama with interface to Energy monitoring N/A L.S #VALUE!
system
10.1.9.5 Allow for installation of water meter for fire water tank and all associated cabinet, accessories, controls and N/A L.S #VALUE!
as required by ADDC

10.1.9.6 Allow for emergency water tanks filling line with associated cabinet, inlets, valves, fittings and accessories N/A L.S #VALUE!
and as required by ADDC

10.1.11 Ablution tap for roof, garbage room, plant rooms and basement complete with isolating valves, back flow 18 No -
preventer, support and accessories

10.1.12 Valves
10.1.12.1 Gate Valves
10.1.12.1.1 25Ø 1 L.S -
10.1.12.1.2 32Ø 1 L.S -
10.1.12.1.3 40Ø 1 L.S -
10.1.12.1.4 50Ø 1 L.S -
10.1.12.1.5 65Ø 1 L.S -
10.1.12.1.6 75Ø 1 L.S -
10.1.12.1.7 100Ø 1 L.S -
10.1.12.1.8 125Ø 1 L.S -
10.1.12.1.9 150Ø 1 L.S -
10.1.12.2 Check valves
10.1.12.2.1 25Ø 1 L.S -
10.1.12.2.2 32Ø 1 L.S -
10.1.12.2.3 40Ø 1 L.S -
10.1.12.2.4 50Ø 1 L.S -
10.1.12.2.5 65Ø 1 L.S -
10.1.12.2.6 75Ø 1 L.S -
10.1.12.2.7 100Ø 1 L.S -
10.1.12.2.8 125Ø 1 L.S -
10.1.12.2.9 150Ø 1 L.S -
10.1.12.3 Allow for Water hammer arrestor in every wet area 1 L.S -
10.1.12.4 Allow for Automatic air vents as shown on drawings, specification and where required for proper system 1 L.S -
operation

10.1.12.5 Allow for flexible connectors 1 L.S -


10.1.12.6 Allow for pressure gauges as shown on drawings and as specified 1 L.S -
10.1.13 Electric Water heaters
supply, install test and commission ceiling mounted, horizontal type, electric water heater, sizes and locations as shown on
drawings , complete with connections for fresh water supply and delivery lines to
various sanitary fixtures. With all associated isolation, check, safety and drain valves as specified
10.1.13.4 80 L Capacity 42 No -
10.1.14 Allow for ADDC fees Item -
10.1.15 Allow for all builders work in connection with the installation 1 Item -
10.1.16 Allow for providing all keys, tools, spares, parts and schematic 1 Item -
10.1.17 Allow for all necessary identifications 1 Item -
10.1.18 Allow for the preparation of all necessary installation drawings 1 Item -
10.1.19 Allow for the preparation of all necessary operations and maintenance manuals 1 Item -
10.1.20 Allow for testing and commissioning of all works 1 Item -
10.1.21 Allow for service relocation fees 1 Item -
10.2 Drainage System:
10.2.1 Above ground Drainage pipework:
Supply, installation, testing and commissioning of Soil, waste and vent UPVC pipe work for above ground drainage with all
10.2.1.1 associated fittings, supports and accessories as shown on drawings, required by authorities
and as specified
10.2.1.1.1 40Ø 1 L.S -
10.2.1.1.2 50Ø 1 L.S -
10.2.1.1.3 65Ø 1 L.S -
10.2.1.1.4 80Ø 1 L.S -
10.2.1.1.5 110Ø 1 L.S -
10.2.1.1.6 160Ø 1 L.S -
10.2.1.2 Below ground drainage pipework:
10.2.1.2.1 Supply and install buried internal and external drainage pipework in uP.V.C pipes class 16 as specified and
shown on the approved drainage drawings.

10.2.1.2.1.1 40Ø 1 L.S -


10.2.1.2.1.2 50Ø 1 L.S -
10.2.1.2.1.3 65Ø 1 L.S -
10.2.1.2.1.4 80Ø 1 L.S -
10.2.1.2.1.5 110Ø 1 L.S -
10.2.1.2.1.6 160Ø 1 L.S -
10.2.4 Storm water Drainage pipework:
10.2.4.1 Supply, installation, testing and commissioning of Rain water UPVC pipe work with all associated fittings,
supports and accessories as shown on drawings, required by authorities and as specified

10.2.4.1.4 80Ø 1 L.S -


10.2.4.1.5 110Ø 1 L.S -
10.2.5 Condensate drain pipework:
Supply, installation, testing and commissioning of UPVC pipe work for condensate drainage with all
10.2.5.1 associated insulation, fittings, supports and accessories as shown on drawings, required by authorities and as specified 1 L.S -
10.2.5.1.1 25Ø 1 L.S -
Construct manholes with covers in specified sizes and depths including all excavations, Backfilling, disposal of surplus, bedding,
10.2.6 benching, branching, water proofing, 200mm solid block as per drawing, reinforced 1 L.S -
concrete at the top level around the frame.
10.2.6.1 Cover and frame of the manholes shall be light duty, and with double seal for manholes subject to 1 L.S -
pedestrian traffic and heavy duty with GRP seal for manholes subject to vehicular traffic.

10.2.7 Supply and install Rain water outlets as specified, shown on drawings and to engineer/ architect approval 1 L.S -
10.2.8 Supply and install Floor drain with covers as specified and to engineer/ architect approval 1 L.S -
10.2.10 Supply and install manholes with heavy duty grating and sediment bucket as specified and to engineer/ 1 L.S -
architect approval

10.2.11 Supply and install Gulley trap with covers as specified, shown on drawings and required by authorities 1 L.S -
10.2.13 Supply and install balcony drain with cover as specified and to engineer/ architect approval 1 L.S -
10.2.19 Supply and install Clean outs on every change of direction and as required 1 L.S -
10.2.20 Supply and install Catch basins with covers as specified, shown on drawings 1 L.S -
10.4 Toilet & Bathroom
10.4.4.2 Baths shall have the following :
10.4.4.2.1 W.C. 36 Nos. -
10.4.4.2.2 European W.C., floor mounted, syphonic, double trap, with low level cistern, ball valve, Chrome Plated 36 Nos. -
fittings, seat and cover, hose and spray nozzle with hook.

10.4.4.2.3 Wash Basin 36 Nos. -


10.4.4.2.4 Pedestal type wash basin, with hot\cold water mixer, complete. 36 Nos. -
10.4.4.2.5 Shower tray : 36 Nos. -
10.4.4.2.6 Showers enclusers with powder coated white aluminum frame as shown on drawings. 36 Nos. -
10.4.4.2.7 Exposed Showers mixer with hose, hand shower, Ä etc. with all accessories, complete. 36 Nos. -
10.4.4.2.8 Soap dish for wash basin. 36 Nos. -
10.4.4.2.9 Soap dish for shower 36 Nos. -
10.4.4.2.10 Toilet roll holder. 36 Nos. -
10.4.4.2.11 Toilet brush & holder. 36 Nos. -
10.4.4.2.12 Towel rail. 36 Nos. -
10.4.4.2.13 Robe hook 36 Nos. -
10.4.4.2.14 Mirror. 36 Nos. -
10.4.4.2.15 Shelf 36 Nos. -
11 Fire fighting works
11.2 Supply and install Dry powder type portable Fire Extinguishers and fire blanket including hangers, hose, and 6 No -
accessories , all as specified in compliance with NFPA and UAE fire and life safety code.

12 AIR CONDITIONING AND VENTILATION SYSTEMS


12.1 Supply, install, test and commission the following A/C equipment and materials as specified and shown on
the drawings:

12.2 DX SPLIT UNITS:


Supply, Installation, Testing and Commissioning of DX Units along with all supports, base stands, valves, flexible connections,
12.2.1 accessories, refrigerant gas, drain pump, drain pipe, dampers and consumables as
described in the Technical Specifications & Drawings.
12.2.2 Wall Mounted DX units
12.2.3 Total load: 1.7 Kw, Sensible load: 1.6 Kw 1 No. -
12.3 VRF SYSTEM:
Supply, Installation, Testing and Commissioning of VRF System along with all supports, base stands, valves, flexible
12.3.1 connections, accessories, refrigerant gas, drain pump, drain pipe, dampers and consumables
as described in the Technical Specifications & Drawings.
12.3.2 Outdoor units:
12.3.2.1.1 01-VRF-ODU-01 23.18 KW 1 No. -
12.3.2.1.2 01-FCU-1 2.8 KW WALL MOUNTED UNIT 1 No. -
12.3.2.1.3 01-FCU-2 4.3 KW DUCTED UNIT TYPE 1 No. -
12.3.2.1.4 01-FCU-3 11.8KW DUCTED UNIT TYPE 1 No. -
12.3.2.1.5 01-VRF-ODU-02 26.28 KW 1 No. -
12.3.2.1.6 01-FCU-4 4.9 KW DUCTED UNIT TYPE 1 No. -
12.3.2.1.7 01-FCU-5 5.7KW DUCTED UNIT TYPE 1 No. -
12.3.2.1.8 01-FCU-6 5.4KW DUCTED UNIT TYPE 1 No. -
12.3.2.1.9 01-FCU-7 3.1KW DUCTED UNIT TYPE 1 No. -
12.3.2.1.10 01-FCU-8 2.5KW WALL MOUNTED UNIT 1 No. -
12.3.2.2.1 02-VRF-ODU-01 23.18 KW 1 No. -
12.3.2.2.2 02-FCU-1 2.4 KW WALL MOUNTED UNIT 1 No. -
12.3.2.2.3 02-FCU-2 4.3 KW DUCTED UNIT TYPE 1 No. -
12.3.2.2.4 02-FCU-3 10.4 KW DUCTED UNIT TYPE 1 No. -
12.3.2.2.5 02-VRF-ODU-02 26.28 KW 1 No. -
12.3.2.2.6 02-FCU-4 3.5 KW DUCTED UNIT TYPE 1 No. -
12.3.2.2.7 02-FCU-5 5.1KW DUCTED UNIT TYPE 1 No. -
12.3.2.2.8 02-FCU-6 5.4KW DUCTED UNIT TYPE 1 No. -
12.3.2.2.9 02-FCU-7 3.1KW DUCTED UNIT TYPE 1 No. -
12.3.2.2.10 02-FCU-8 2.3KW WALL MOUNTED UNIT 1 No. -
12.3.2.3.1 03-VRF-ODU-01 23.18 KW 1 No. -
12.3.2.3.2 03-FCU-1 2.3 KW WALL MOUNTED UNIT 1 No. -
12.3.2.3.3 03-FCU-2 4.5 KW DUCTED UNIT TYPE 1 No. -
12.3.2.3.4 03-FCU-3 10.4 KW DUCTED UNIT TYPE 1 No. -
12.3.2.3.5 03-VRF-ODU-02 26.28 KW 1 No. -
12.3.2.3.6 03-FCU-4 3.5 KW DUCTED UNIT TYPE 1 No. -
12.3.2.3.7 03-FCU-5 5.3 KW DUCTED UNIT TYPE 1 No. -
12.3.2.3.8 03-FCU-6 5.7 KW DUCTED UNIT TYPE 1 No. -
12.3.2.3.9 03-FCU-7 3.4 KW DUCTED UNIT TYPE 1 No. -
12.3.2.3.10 03-FCU-8 2.7 KW WALL MOUNTED UNIT 1 No. -
12.3.2.4.1 04-VRF-ODU-01 23.18 KW 1 No. -
12.3.2.4.2 04-FCU-1 2.3 KW WALL MOUNTED UNIT 1 No. -
12.3.2.4.3 04-FCU-2 4.5 KW DUCTED UNIT TYPE 1 No. -
12.3.2.4.4 04-FCU-3 10.5 KW DUCTED UNIT TYPE 1 No. -
12.3.2.4.5 04-VRF-ODU-02 26.28 KW 1 No. -
12.3.2.4.6 04-FCU-4 3.5 KW DUCTED UNIT TYPE 1 No. -
12.3.2.4.7 04-FCU-5 5.3 KW DUCTED UNIT TYPE 1 No. -
12.3.2.4.8 04-FCU-6 5.0 KW DUCTED UNIT TYPE 1 No. -
12.3.2.4.9 04-FCU-7 3.4 KW DUCTED UNIT TYPE 1 No. -
12.3.2.4.10 04-FCU-8 2.7 KW WALL MOUNTED UNIT 1 No. -
12.3.2.5.1 05-VRF-ODU-01 23.18 KW 1 No. -
12.3.2.5.2 05-FCU-1 2.4 KW WALL MOUNTED UNIT 1 No. -
12.3.2.5.3 05-FCU-2 4.4 KW DUCTED UNIT TYPE 1 No. -
12.3.2.5.4 05-FCU-3 10.4 KW DUCTED UNIT TYPE 1 No. -
12.3.2.5.5 05-VRF-ODU-02 26.28 KW 1 No. -
12.3.2.5.6 05-FCU-4 3.5 KW DUCTED UNIT TYPE 1 No. -
12.3.2.5.7 05-FCU-5 5.3 KW DUCTED UNIT TYPE 1 No. -
12.3.2.5.8 05-FCU-6 4.9 KW DUCTED UNIT TYPE 1 No. -
12.3.2.5.9 05-FCU-7 3.2 KW DUCTED UNIT TYPE 1 No. -
12.3.2.5.10 05-FCU-8 2.3 KW WALL MOUNTED UNIT 1 No. -
12.3.2.6.1 06-VRF-ODU-01 23.18 KW 1 No. -
12.3.2.6.2 06-FCU-1 2.8 KW WALL MOUNTED UNIT 1 No. -
12.3.2.6.3 06-FCU-2 4.4 KW DUCTED UNIT TYPE 1 No. -
12.3.2.6.4 06-FCU-3 11.6 KW DUCTED UNIT TYPE 1 No. -
12.3.2.6.5 06-VRF-ODU-02 26.28 KW 1 No. -
12.3.2.6.6 06-FCU-4 4.9 KW DUCTED UNIT TYPE 1 No. -
12.3.2.6.7 06-FCU-5 6.0 KW DUCTED UNIT TYPE 1 No. -
12.3.2.6.8 06-FCU-6 4.9 KW DUCTED UNIT TYPE 1 No. -
12.3.2.6.9 06-FCU-7 3.1 KW DUCTED UNIT TYPE 1 No. -
12.3.2.6.10 06-FCU-8 2.5 KW WALL MOUNTED UNIT 1 No. -
12.6 Fans
Supply, Installation, Testing and Commissioning of Exhaust fans along with all supports, base stands, valves, flexible
12.6.4 connections, accessories, dampers and consumables as described in the Technical
Specifications & Drawings.
12.6.4.1 TEF-01 (25 LPS) GLASS/WALL MOUNTED 18 No. -
12.6.4.2 TEF-02 (50 LPS) GLASS/WALL MOUNTED 6 No. -
12.6.4.3 TEF-03 (75 LPS) INLINE DUCTED 6 No. -
12.6.4.4 TEF-03 (50 LPS) INLINE DUCTED 6 No. -
12.7 Ductwork and Accessories
12.7.1 Sheet metal ductworks; complete with thermal insulation, canvas and coating, supports, anti-vibration 1 L.S -
mounts and all necessary accessories; all in accordance with drawings and specification
12.7.1.1 Insulated Supply and return air ductwork 1 L.S -
12.7.1.3 Insulated extract air ductwork 1 L.S -
12.7.1.4 non-insulated ductwork 1 L.S -
12.7.2 Volume control dampers 1 L.S -
12.7.12 Acoustic Liner 1 L.S -
12.7.13 Flexible ducts 1 L.S -
12.8 Grilles, Diffusers and registers
12.8.1 Air distribution outlets including plenum boxes, thermal insulations, acoustic insulation dampers, fittings, 1 L.S -
fixings in positions all complete as specified and as shown on drawings.

12.8.2 Supply 4-Ways diffusers with associated plenums, flexible ducts, supports and accessories 1 L.S -
12.8.3 Return 4-Ways diffusers complete as shown on drawings and as specified 1 L.S -
12.8.4 Supply Register complete as shown on drawings and as specified 1 L.S -
12.8.5 Return Grilles complete as shown on drawings and as specified 1 L.S -
12.8.6 Extract air grilles complete as shown on drawings and as specified 1 L.S -
12.8.7 Toilet round disc type extract diffuser. 1 L.S -
12.8.8 Supply linear slot diffusers with associated plenums, flexible ducts, supports and accessories
12.8.8.1 SLD-01 1 L.S -
12.8.8.2 SLD-02 1 L.S -
12.8.8.3 SLD-03 1 L.S -
12.8.8.4 SLD-04 1 L.S -
12.8.9 Return Linear slot diffusers
12.8.9.1 RLD-01 1 L.S -
12.8.9.2 RLD-02 1 L.S -
12.8.9.3 RLD-03 1 L.S -
12.8.9.4 RLD-04 1 L.S -
12.8.10 Supply linear bar grilles with associated plenums, flexible ducts, supports and accessories
12.8.10.1 SLBG-01 1 L.S -
12.8.10.2 SLBG-02 1 L.S -
12.8.10.3 SLBG-03 1 L.S -
12.8.10.4 SLBG-04 1 L.S -
12.8.11 Return Linear bar grilles
12.8.11.1 RLBG-01 1 L.S -
12.8.11.2 RLBG-02 1 L.S -
12.8.11.3 RLBG-03 1 L.S -
12.8.11.4 RLBG-04 1 L.S -
12.8.12 Intake and Extract louvers 1 L.S -
13 ELEVATORS AND CRADLE
13.1 ELEVATORS
13.1.1 Passenger Lift
Design, supply and install passenger lifts complete as specified including all motors guide rails, counter weights, elevator car,
13.1.1.1 doors and frames, finishings,buffers, furnishings, accessories, fixings, signals, safety
gear, controls etc. all as per Specification and Drawings
13.1.1.1.1 Elevator No 1 - ÄÄ.. Kg , Ä.. persons capacity ÄÄ.meter / min , Ä..stop, Ä..openings, Ä... wide x ÄÄ.mm No. -
depth clear cabin size, hydroelectric computerised control (indirect side acting) as Specified

13.1.1.1.2 Elevator No 2- ÄÄ.. Kg , Ä.. persons capacity ÄÄ.meter / min , Ä..stop, Ä..openings, Ä... wide x ÄÄ.mm No. -
depth clear cabin size, hydroelectric computerised control (indirect side acting) as Specified

13.1.2 Car Lift


13.1.2.1 Design, supply and install Car lifts complete as per Specification and Drawings No. -
13.1.3 Dumb Waiter
13.1.3.1 Single opening, .. kg. capacity, No. -
Case size : . .. x . . .. x . . .., stops,
Entrance dimension : . . .. x . . . .
as per specifications and drawings.

13.1.4 SUNDRIES
13.1.4.1 Allow for production of all working drawings, calculations,specification, operation and maintenance manuals Item -

13.1.4.2 Allow for all general builder's work in connection with the lift installation Item -
13.1.4.3 Allow for testing and commissioning lift installation Item -
13.2 CRADLE
13.2.1 Window Cleaning Cradle System
13.2.1.1 Supply, install, test, commission and maintain window cleaning cradle equipment/system complete in Item -
accordance with specification and drawings.

13.2.1.2 SUNDRIES
13.2.1.2.1 Allow for production of all working drawings, calculations,specification, operation and maintenance manuals Item -

13.2.1.2.2 Allow for all general builder's work Item -


13.2.1.2.3 Allow for testing and commissioning Item -
16 ELECTRICAL WORKS
Supply, install, testing and commissioning of all electrical installation strictly in accordance with the specifications and as
16.1 indicated on the drawings and authorities requirements but not limited to the following 1 L.S -
items:
16.2 Incoming Mains Installation 1 L.S -
16.2.1 Allow for all works required by the specifications and shown on the drawings for providing incoming mains 1 L.S -
installation through ADDC including liaison, and all builder's work listed below:

16.2.2 Existing network is to be located by hand excavation.(if any ) 1 L.S -


16.2.3 Proper protection is to be provided by contractor for all existing netowrks. 1 L.S -
16.2.4 All effected networks shown or if discovered during execution are to be relocated by contractor to a proper 1 L.S -
route reservation.

16.2.5 Cost of protection, relocation and other related work are to be beard by Contractor. 1 L.S -
16.2.6 New route reservation is to be considered for future LV network expansion 1 L.S -
16.2.7 Allow for all works required by the specifications and shown on the drawings for providing incoming mains 1 L.S -
installation through ADDC including liaison, and all builder's work.

16.2.8 Paying statutory ADDC charges, connection fees for acquiring main supply including but not limited to the 1 L.S -
following (LV Panels, Energy Meters, etc...) Rates and Insurance.

16.3 Main & Distribution Low Volt main board (MDB):


16.3.1 Supply, install, testing , equipments, accessories and materials as specified and shown on the drawings 1 L.S -

Supply, install and testing of Main Distribution Board (MDB) (FORM 2B) switch board comprising of all
16.3.2 switch gear, bus bar, meters, indicator lights complete as specified, shown on the drawings and As per authorities requirements 1 L.S -

16.3.3 Sub - main distribution boards as specified and shown on the drawings. 6 No -
16.3.4 Supply, install and testing of Final distribution boards as specified and shown on the 20 No -
drawings.

16.3.5 Supply, install and testing of Capacitor Bankas AS required by the local authority and 1 No -
as specified and shown on the drawings.(100KVAR )

16.3.6 Ducts, earthing, manholes and manhole cover grade A as required by Authorities & 1 L.S -
ADDC

Supply and install, Test, Commission and maintain main and sub feeder copper cables as shown on drawings including
16.3.7 termination, cable ties, and all necessary accessories 1 L.S -
and related ancillaries works specified as a required by the drawings and as per ADDC requirments.
16.4 Low Voltage cables
Supply and install, Test, Commission and maintain main and sub feeder copper cables as shown on drawings including
16.4.1 termination, cable ties, and all necessary accessories and related ancillaries works 1 L.S -
specified as a required by the drawings
16.4.2 Armored cables, cable cleats, cable terminals etc. 1 L.S -
16.4.3 Fire rated cables FP400 1 L.S -
16.4.4 2 core cables including terminations, supports etc.. 1 L.S -
16.4.5 Single core cables and wires drawn into conduits/ducts including terminations, supports etc. 1 L.S -
16.5 Cable Trays, Ducts, and Accessories
16.6.1 Supply and installation of the cCable Trays, Ducts, and Accessories including required supports as per site 1 L.S -
requirement, hardwares, etc... As shown in the drawings

16.6.2 GI cable trays, with covers for external area with supports 1 L.S -
16.6.3 GI cable trays for internal area with supports 1 L.S -
16.6.4 Cable ducts and accessories. 1 L.S -
16.7 Wiring Accessories
Socket outlets Supply, install, test, commission and maintain socket outlets including boxes, conduits, conduits fittings, wiring,
16.7.1 plugs and accessories connecting from the branch circuit and back to the panel 1 L.S -
board as specified and as required by the drawings
16.7.2 Double pole + earth 13A Single switch socket outlets 60 No -

16.7.3 Ditto Double pole + earth 13A Duplex /twin switch socket outlets 160 No -

16.7.4 Ditto Double pole + earth 13A Single switch socket, W.P. 36 No -
16.7.5 Ditto but 20 A DP FUSED FLEXIBLE switch outlet and neon indicator . 21 No -
16.7.6 Ditto but 20 A DP FUSED FLEXIBLE switch and outlet neon indicator (FCU). 60 No -
16.7.7 Ditto but 20 A DP FUSED FLEXIBLE switch and outlet neon indicator for water heater. 60 No -
16.7.8 Ditto but shaver socket. 18 No -
16.7.9 Ditto but 13A fused spur outlet. 18 No -
16.7.10 Ditto but single phase isolator. 30 No -
16.7.11 Ditto but 3 phase isolators. 30 No -
16.7.12 Ditto but for Double pole 45 Amp Cooker control unit with flexible outlet . 6 No -
16.7.13 kitchen hood power outlet 6 No -
16.7.14 Bell and Bell push. 6 No -
16.7.15 exhaust fan outlet 23 No -
Lighting switches Supply, install, test, commission and maintain lighting switches including boxes, conduits fitting, switches,
16.7.16 termination conduits and wiring from switches to branch circuits as specified and as 1 L.S -
required by the drawings
16.7.17 push switch with timer for stair case 18 No -
16.7.18 Ditto but-- One way switch, -- One gang switch 72 No -
16.7.19 Ditto but-- One way switch, -- One gang switch --- WP 24 No -
16.7.20 Ditto but-- One way switch, -- Two gang switch 28 No -
16.7.21 Ditto but-- One way switch, -- Three gang switch 42 No -
16.7.22 Ditto but-- Two way switch, -- One gang switch 18 No -
16.7.23 Ditto but-- Two way switch, -- Two gang switch 60 No -
16.7.24 Ditto but-- Two way switch, -- Two gang switch -- intermediate 18 No -
16.7.25 Ditto but-- Three way switch, -- Three gang switch 6 No -
16.7.26 switch with timer 1 No -
16.8 Busbar Trunking
Supply, install, test, commission and maintain low voltage busway system complete with all special fittings, hanging and
16.8.1 mounting components, materials and ancillary works required for the complete operative 1 L.S -
system in accordance with the specification and drawings
16.9 Light Fixtures:
16.9.1 Supply, install, testing and commissioning of Lighting system in accordance with technical specification & 1 L.S -
drawings complete with necessary accessories ceiling rose,supports and anxillaries works

16.9.2 Light fitting , Type F1 135 No -


16.9.3 Light fitting , Type F2 69 No -
16.9.4 Light fitting , Type F3 112 No -
16.9.5 Light fitting , Type F4 126 No -
16.9.6 Light fitting , Type F5 with shaver socket as per drawings 30 No -
16.9.7 Light fitting , Type F6 36 No - Final selction of light fittings is subject to final approved
16.9.8 Light fitting , Type F7 78 No - light fittings and approved lux levels standards
16.9.9 Light fitting , Type F8 15 No -
16.9.10 Light fitting , Type F9 45 No -
16.9.11 Light fitting , Type F10 15 No -
16.9.12 Light fitting , Type F11 39 No -
16.9.13 Light fitting , Type F12 275 m -
Lighting point,Supply, install, test, commission including boxes, conduits fitting, termination, conduits and
16.9.14 wiring fro a of lighting point as specified and as required by the drawings, exhaust fan point, bell point emergency and exit point. 1 L.S -

16.1 Electrical services to mechanical works.


16.10.1 Empty conduits and draw wires to thermostats as necessary for A/C installation. 1 L.S -
16.10.2 All cables, cable trays etc, from SMDBS-FDBS panel to motors isolators heat batteries etc, including all 1 L.S -
connection.

16.11 Analogue Addressable Fire Alarm System: 1 L.S -

Supply, installation, testing and commissioning of a complete fire-alarm system, detector but not limited to hardware and
software , keyboard, relays,fire telephone , fire pump monitoring and alarm emergency generators monitoring, elevator recall
control and relays, interface unit with: lifts HVAC, access control system, lighting control system, central battery and emrgency
16.11.1 light system, auto dial to local authority, mimic panel, battery and battery charger, all interfaces with other trades, Graphic 1 L.S -
command centre with PC., printer etc. and all necessary complete ancillary works and accessories required for the complete
installation as specified & shown on the drawings and as required by UAE fire and life safety code of practice

16.11.2 Addressable heat detector 20 No - Final is subject to ADCD Approval


16.11.3 Addressable smoke detector 45 No -
16.11.4 Analog addressable photo electric smoke detector with sounder base 60 No -
16.11.5 Wall mounted fire alarm bell 24 No -
16.11.6 Break glass 24 No -
Final is subject to ADCD Approval

16.11.7 Emergency light No -


16.11.8 Exit light 8 No -
16.11.9 Fire alarm control panel 6 No -
16.11.10 Hassantuk System as required by UAE fire and life safety code of practice Supply, installation, testing and 1 L.S -
commissioning of a complete Of Hassantuk System system.

16.14 Emergency Lights And Exit light System


Supply,install,test,commission & maintain central battery system including, but not limited to, central battery panels, emergency
lights, changeover modules, control modules, local controllers, batteries, battery charger, conduits, cable trunk, fire rated cable,
conduit, conduit fitting, trunking ,interface unit with fire alarm system
16.14.1 ,lighting control and BMS systems, etc, and all necessary complete ancillary works & accessories required for the complete 1 L.S -
installation as required by UAE fire code, as specified and as required by the drawings.
ADCD Approval

16.14.2 Emergeny ight fixtures Type SELF CONTAINED TYPE (3HRS) AS PER INDICATED ON DRAWINGS IP 40 40 No -

16.14.3 EXIT LIGHT ight fixtures Type -- AS PER INDICATED ON DRAWINGS IP 44 8 No -


16.15 Telephone system:
16.15.1 Supply, installation, testing and commissioning of the system with all necessary accessories as 1 L.S -
specified,Allow for all works required by Authorities & Etisalat regarding the affected telephone plant

16.15.2 Ducts, earthing and manholes as required by Authorities & ETISALAT 1 L.S -
16.15.3 Conduits, conduit accessories, draw boxes, wires, GI accessory boxes, fiber optic cables, fixing, etc.., 1 L.S -
complete for telephone socket outlet as "Authorities & ETISALAT " approval.

16.15.4 ODF (OPTICAL DISTRIBUTION FRAME ) 1 No -


16.15.5 ONU (60X60X15 cm ) 6 No -
16.15.6 JUNCTION BOXES 12 No -
16.15.7 Telephone DUAL outlet (RJ45) with cover plate same finish of the wiring accessories 48 No -
16.15.8 Telephone outlet (RJ45) with cover plate same finish of the wiring accessories 76 No -
16.16 Satellite Receiving Television Systems:
Supply , install, test, commission and maintain SMATV system as specified and as shown on the drawing including ,but not
limited to dishes,switches,cables, amplifiers, PVC junction boxes, conduits, sockets
16.16.1 ,distribution boxes, Tap-off boxes, amplifiers, coaxial cables and cable fitting all the necessary accessories and ancillary 1 Item -
materials required for the complete installation as specified and as required by the drawings

16.16.2 SMATV socket triple outlet 55 No -


16.16.3 Passive Multi switch 12 No -
16.16.4 Launch amplifier 12 No -
16.16.5 Headend equipment 6 No -
16.16.6 1200 mm dia solid dish 18 No -
16.17 Keypad Video Intercom System:
Supply, installation & commissioning of video Keypad intercom system for the building, including but not limited to main
16.17.1 entrance panels, handsets / wall sets, video shunt unit, power supply and all the required 1 L.S -
accessories, supports as specified and as required by the enclosed specifications and related drawings
16.17.2 Video intercom outlet 36 No -
16.17.3 Video intercom control panel 6 No -
16.22 Earthing system
Supply, install, test, commission and maintain complete protective earthing (PE) system including earthing pits, earthing
electrodes, equalizer bars, earth continuity conductor and earthing conductor, fixing, test links, suspensions, drilling and cutting
16.22.1 1 L.S -
for complete installation as specified and as required by the drawings earth
pits complete with electrode, clamps, couplers, cables, earth pit chamber with cover
16.23 Lightning Protection
Supply, install, test, commission and maintain complete lightning protection system including all accessories required for the
complete installation, Earth pits, clamps, and earthpit chamber with cover,complete with earth electrode, cable, Air Terminal
16.23.1 lightning protection,Copper strip lightning conductor with all accessories like square tape clamps ,fixing tape clips/ copper 1 L.S -
connector equipment clap, test link, test clap etc.. as
specified and as required by the drawings
16 ELECTRICAL WORKS
16.25.1 Allow for painting of the installation if required. 1 Item -
16.25.2 Allow for maintenance of the installation for two calendar years. 1 Item -
16.25.3 Allow for guarantee and warranties. 1 Item -
16.25.4 Allow for testing and commissioning. 1 Item -
16.25.5 Allow for statutory change for e-routing of all existing telephone/GSM services within the plot and which may 1 Item -
be affected due to the construction of the new building

16.25.6 Allow for all electrical items not included above but needed to complete the installation as detailed & 1 Item -
specified

16.26 Builders work


16.26.1 Allow for marking the position of holes, mortises, chases and the like in the structure 1 Item -
16.26.4 Allow for providing any g pipe sleeves in accordance with the drawings 1 Item -
16.26.5 Allow for any other builders work for the electrical work not specifically covered by above items 1 Item
16.27 Documentation:
16.27.1 Allow for all submittals, samples, shop drawings, As-built Drawings, warranty certificates, testing & 1 Item
commissioning.

16.28 Sundries
16.28.1 Allow for producing all working drawings for the approval of the Engineer 1 Item
16.28.2 Allow for testing and commissioning the installations on completion to the satisfaction of the Engineer 1 Item
16.28.3 Provision of sign boards as per ADCE design and requirement 1 Item
16.28.4 Allow for providing all spares and handing to the Engineer all as specified 1 Item
16.28.5 Allow for providing all painting plates, disks, labels etc. for the identification of plant, equipment cables, 1 Item
switches and the like as specified

16.28.6 Allow for providing drawings showing the installations –as fitted” 1 Item
16.28.7 Allow for provision of operating and maintenance manuals to the satisfaction of the Engineer as specified 1 Item
16.28.8 Allow for any other necessary items required for the completion of the work as described in the relevant 1 Item
sections of the specifications and drawings and not mentioned herein.

16.29 Emergency, Operation & Maintenance contract (EOM) during the DLP, all as per preventive & reactive
maintenance in accordance with the manufacturers recommendation.

16.29.1 EOM for lifts 1 Item


16.29.2 EOM for Chillers / AC system / FAHU. 1 Item
16.29.3 EOM for Domestic pumps & FLS equipment as per ADCD. 1 Item
16.29.9 EOM for Automatic Waste Management system. 1 Item
17 Fixed Furniture & Equipment (FFE)
Allow for Provisional Sum (PS) of AED 150,000/- for Gymnasium Equipment intended for Commercial use. (Minimum:
Treadmill, Elliptical, Upright & Recumbent bikes, Multiposition and Abdominal benches, Cable cross over machine & Dumbbels
17.1 150,000.00
set with rack), to be approved by the Owner.

17.2 Allow for Provisional Sum (PS) of AED 12,000/- for Building Reception: 12,000.00
. Synthetic leather sofa set 3 +2 or 3+1+1 and Center Coffee Table.

Allow for Provisional Sum (PS) of AED 12,000/- for Swimming Pool Furniture:
. 8 Sunlounger made of glassfiber technopolymer frame with texteline / mesh fabric seat. Size min (190x70)cm.
. 4 side tables made of technopolymer.
17.3 . 4 Umbrellas made of aluminum single pole & ribs with polyester cover. Size (300cm Dia) with 50kgs Granite base with wheels. 12,000.00

17.4 Allow for Contractor Overhead and Profit (@7%) on the above 17.1, 17.2 & 17.3 including transportation, %
unloading, storage, fixtures, coordination and all other related services for the subcontractors / vendors.

18 CONTRACTOR'S ADJUSTMENT SHEET


18.1 Contractor's Adjustment Sheet (Missing Items in BOQ) Item
18.1.1 Item 1 Item
18.1.2 Item 2 Item
18.1.3 Item 3 Item
19 SCHEDULE OF RATES FOR DAYWORKS
19.1 Labour
19.1.1 Scaffolders 0 hr.
19.1.2 Steelfixers 0 hr.
19.1.3 Plumbers 0 hr.
19.1.4 Carpenters and Joiners 0 hr.
19.1.5 Plasterers 0 hr.
19.1.6 Masons 0 hr.
19.1.7 Painters 0 hr.
19.1.8 Plant and machinery operators and drivers (Light Duty) 0 hr.
19.1.9 Plant and machinery operators and drivers (Heavy Duty) 0 hr.
19.1.10 Electricians 0 hr.
19.1.11 A/C Mechanics 0 hr.
19.1.12 Welders 0 hr.
19.1.13 Helpers 0 hr.
19.1.14 Labourers 0 hr.
19.2 Materials
19.2.1 Contractor's percentage on the net cost of material 0 %
19.3 Equipment & Tools
19.3.1 Wheeled offset excavator with backhoe and shovel (JCB type) 0 hr
19.3.2 Pick up truck up to 3 T capacity 0 hr
19.3.3 Dumper 2 T 0 hr
19.3.4 Concrete vibrator 0 hr
19.3.5 Soil compactor 0 hr
19.3.6 Compressor 0 hr
19.3.7 Tower Crane (. capacity) 0 hr
19.3.8 Mobile crane (. capacity) 0 hr
19.3.9 Generator 0 hr
19.3.10 Scaffolding 0 m2/day
19.3.11 Gas cutting set with all accessories 0 hr
19.3.12 Dewatering pump with all required accessories 0 day
19.4 Work Outside Normal Work Hours
19.4.1 Percentage uplift to labour costs for working outside normal site hours ON ENGINEER'S INSTRUCTION. 0 %
20 Consultant Fees
20.1 Consultant Fees 0.04 L.S.
-

-
-
-
-
-

-
-
-

-
-
-
-

-
-
-
-

-
-
-
-
-
-
-
-
-
-
-
-
-
-

-
-
-
-
-
-
-
-
-
-
-
-