Datasheet for ROTAMASS Prime + Ultimate

FlowConfigurator-Version: 2.29.1.5418 Date of creation: 9/26/2023


Page: 1/2
Model: RCUP25S-15BD60-0C70-GF21-2-G11
Sensor options: /QR2/VE
Fluid type: Newtonian Liquid
Fluid: water
Temperature: 20 °C
Pressure: 5 bar absolute
Viscosity: 1.001 mPas
Density: 0.9984 kg/l
Kind of flow: Mass flow
Mass flow flat spec.: 0.10 %
Accuracy density: 0.004 g/cm³ (C7)

Flow rate Pressure loss Accuracy * Velocity **


Pulse/Frequency output

kg/h mbar in % of flow rate m/s


Mass flow
Minimum flow rate 60 4.223 0.11 0.339
entered as process value

Operating flow rate 150 17.46 0.10 0.847


entered as process value

Maximum flow rate 400 88.89 0.10 2.26


entered as process value

Maximum flow rate 2300 1970 0.10 13


for the current sensor under process
conditions

ROTA YOKOGAWA - FLOW CENTER OF EXCELLENCE


Datasheet for ROTAMASS Prime + Ultimate
FlowConfigurator-Version: 2.29.1.5418 Date of creation: 9/26/2023
Page: 2/2
Calculation results for different flow rates
Flow rate Pressure loss Accuracy * Velocity ** Reynolds number
Pulse/Frequency output
% kg/h mbar in % of flow rate m/s
Mass flow
100 400 88.89 0.10 2.26 12610
90 360 74.29 0.10 2.03 11350
80 320 60.86 0.10 1.81 10090
70 280 48.62 0.10 1.58 8829
60 240 37.61 0.10 1.36 7568
50 200 27.84 0.10 1.13 6307
40 160 19.37 0.10 0.904 5045
30 120 12.24 0.10 0.678 3784
20 80 6.519 0.10 0.452 2523
10 40 2.333 0.14 0.226 1261
* Accuracy specification based on calibration reference conditions (please refer to current General Specifications for more details).
** The flow velocity is valid inside the measuring tubes.

Pressure loss in Mass flow accuracy


in % of flow rate, pulse/frequency

0.14
80

Pressure loss in mbar


0.12
0.10 60
0.08
0.06 40
0.04
20
0.02
0.00 0
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Flow rate (100% = 400 kg/h)

ROTA YOKOGAWA - FLOW CENTER OF EXCELLENCE