2/16/23, 3:14 PM Niik Group - BHP Jansen Vertical Brace Connection Brace-1

Gusset to Column Shear Tab Connection Code=AISC 360-16 LRFD

Result Summary geometries & weld limitations = PASS limit states max ratio = 0.66 PASS

Geometry Restriction Checks - Shear Tab to Gusset Plate PASS

Weld Limitation Check - Shear Tab Weld PASS

Brace Force Load Case 1 Gusset plate t=15.9 P =700.0 kN (C) ratio = 0.66 PASS

Gusset Plate - Shear Yielding ratio = 386.2 / 2294.3 = 0.17 PASS

Gusset Plate - Shear Rupture ratio = 386.2 / 1992.2 = 0.19 PASS

Shear Tab - Shear Yielding ratio = 386.2 / 2184.6 = 0.18 PASS

Shear Tab - Shear Rupture ratio = 386.2 / 1867.1 = 0.21 PASS

Shear Tab - Plate Flexural Yielding ratio = 40.6 / 614.4 = 0.07 PASS

Shear Tab - Plate Flexural Rupture ratio = 40.6 / 576.6 = 0.07 PASS

Shear Tab - Flexural Yield Interact ratio = = 0.03 PASS

Shear Tab - Flexural Rupture Interact ratio = = 0.04 PASS

Shear Tab - Bolt Bearing on Shear Tab ratio = 474.7 / 1697.9 = 0.28 PASS

Shear Tab - Block Shear - Center Strip ratio = 386.2 / 3196.7 = 0.12 PASS

Shear Tab - Block Shear - 1-Side Strip ratio = 386.2 / 1763.6 = 0.22 PASS

Shear Tab - Plate Flexural Buckling ratio = 386.2 / 2961.3 = 0.13 PASS

Shear Tab - Plate Shear/Axial Compression Interact ratio = = 0.02 PASS

Shear Tab - Compression Buckling ratio = 276.1 / 3276.8 = 0.08 PASS

Bolt Group Eccentricity

Shear Tab / Gusset - Bolt Shear ratio = 474.7 / 1697.9 = 0.28 PASS

Shear Tab to Column Stiffener Hor Weld Line Strength ratio = 195.4 / 294.5 = 0.66 PASS

Shear Tab to Column Web Ver Weld Line Strength ratio = 386.2 / 1367.0 = 0.28 PASS

Brace Force Load Case 2 Gusset plate t=15.9 P =-700.0 kN (T) ratio = 0.66 PASS

Gusset Plate - Shear Yielding ratio = 386.2 / 2294.3 = 0.17 PASS

Gusset Plate - Shear Rupture ratio = 386.2 / 1992.2 = 0.19 PASS