Heat loss & Efficiency
Heat loss & Efficiency E2
 Heat dissipation
Heat dissipation
Ambient T
E2 0.10 C 0.20 C 0.30 C 0.50 C
[℃]
9.4 A 18.8 A 28.2 A 47.0 A
15 0.10 W 0.41 W 0.91 W 2.53 W
Unit Cell 25 0.07 W 0.26 W 0.59 W 1.63 W
45 0.04 W 0.16 W 0.37 W 1.02 W
15 2.32 W 9.28 W 20.87 W 57.98 W
Module
25 1.53 W 6.10 W 13.73 W 38.13 W
(22S)
45 0.98 W 3.93 W 8.85 W 24.59 W
264S 0.02 KW 0.07 KW 0.16 KW 0.46 KW
Rack 242S 25 0.02 KW 0.07 KW 0.15 KW 0.42 KW
198S 0.01 KW 0.05 KW 0.12 KW 0.34 KW

 Efficiency
Chargeable Dischargeable RTE
E2 CP-rate(C)
BOL EOL BOL EOL BOL D/C Factor
0.1 1.00% 1.20% 1.00% 1.10% 97.50% 0.50%
0.2 2.00% 2.40% 2.00% 2.10% 96.50% 0.50%
0.3 3.00% 3.60% 2.90% 3.00% 95.50% 0.50%
0.5 5.00% 6.00% 3.80% 4.00% 94.50% 0.50%
Copyright : Unless explicitly agreed to, it is not permitted to disclose or copy this document, or to exploit or disclose its contents. Violation is
|
1 /3 liable for damages. All rights in the event of patent and utility model registration reserved. Samsung SDI. ESS Development Group